GSD-2020-12488

Vulnerability from gsd - Updated: 2023-12-13 01:21
Details
The attacker can access the sensitive information stored within the jovi Smart Scene module by entering carefully constructed commands without requesting permission.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2020-12488",
    "description": "The attacker can access the sensitive information stored within the jovi Smart Scene module by entering carefully constructed commands without requesting permission.",
    "id": "GSD-2020-12488"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2020-12488"
      ],
      "details": "The attacker can access the sensitive information stored within the jovi Smart Scene module by entering carefully constructed commands without requesting permission.",
      "id": "GSD-2020-12488",
      "modified": "2023-12-13T01:21:49.615534Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "security@vivo.com",
        "DATE_PUBLIC": "2021-03-23T16:00:00.000Z",
        "ID": "CVE-2020-12488",
        "STATE": "PUBLIC",
        "TITLE": "Broken Access Control Vulnerability in Jovi Smart Scene"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Jovi Smart Scene",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "6.2.2.52",
                          "version_value": "all"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "vivo"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "The attacker can access the sensitive information stored within the jovi Smart Scene module by entering carefully constructed commands without requesting permission."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-284 Improper Access Control"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.vivo.com/en/support/security-advisory-detail?id=5",
            "refsource": "CONFIRM",
            "url": "https://www.vivo.com/en/support/security-advisory-detail?id=5"
          }
        ]
      },
      "source": {
        "discovery": "UNKNOWN"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:vivo:jovi_smart_scene:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "6.2.2.52",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "security@vivo.com",
          "ID": "CVE-2020-12488"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "The attacker can access the sensitive information stored within the jovi Smart Scene module by entering carefully constructed commands without requesting permission."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-668"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.vivo.com/en/support/security-advisory-detail?id=5",
              "refsource": "CONFIRM",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://www.vivo.com/en/support/security-advisory-detail?id=5"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "availabilityImpact": "NONE",
            "baseScore": 2.1,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "NONE",
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 2.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "LOW",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 1.8,
          "impactScore": 3.6
        }
      },
      "lastModifiedDate": "2021-11-15T14:25Z",
      "publishedDate": "2021-11-10T16:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…