The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2018-25048", "id": "GSD-2018-25048" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2018-25048" ], "details": "The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device.", "id": "GSD-2018-25048", "modified": "2023-12-13T01:22:36.726477Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "ID": "CVE-2018-25048", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Control for BeagleBone", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": " Control for emPC-A/iMX6", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "Control for IOT2000", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "Control for PFC100", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "Control for PFC200", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "Control for Raspberry Pi", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "Control RTE V3 (all variants)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "Control Win V3 (all variants)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "V3 Simulation Runtime (part of the CODESYS Development System)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "HMI V3 (all variants)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "V3 Remote Target Visu (all variants)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "Control V3 Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "V3 Embedded Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "V3 Remote Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "3.0.0.0", "version_value": "3.5.12.30" } ] } }, { "product_name": "Runtime Toolkit 32 bit embedded", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "2.0.0.0", "version_value": "2.3.2.10" } ] } }, { "product_name": "Runtime Toolkit 32 bit full", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "2.0.0.0", "version_value": "2.4.7.52" } ] } }, { "product_name": "Runtime PLCWinNT", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "2.0.0.0", "version_value": "2.4.7.52" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "credits": [ { "lang": "en", "value": " Prosoft-Systems Ltd." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-22", "lang": "eng", "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf", "refsource": "MISC", "url": "https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf" } ] }, "source": { "defect": [ "CERT@VDE#64324" ], "discovery": "EXTERNAL" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:codesys:runtime_plcwinnt:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.4.7.52", "versionStartIncluding": "2.0.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:runtime_system_toolkit:*:*:*:*:*:*:x86:*", "cpe_name": [], "versionEndExcluding": "2.4.7.52", "versionStartIncluding": "2.0.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:runtime_system_toolkit:3.5.15.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_v3_runtime_system_toolkit:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:simulation_runtime:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.5.12.30", "versionStartIncluding": "3.0.0.0", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "ID": "CVE-2018-25048" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-22" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf", "refsource": "MISC", "tags": [ "Not Applicable" ], "url": "https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-03-30T17:50Z", "publishedDate": "2023-03-23T11:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.