Action not permitted
Modal body text goes here.
Modal Title
Modal Body
ghsa-wm2q-rjqh-v4ff
Vulnerability from github
Published
2022-05-24 17:35
Modified
2022-10-09 00:00
Severity ?
Details
Older firmware versions (FW1 up to FW10) of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack.
{ "affected": [], "aliases": [ "CVE-2020-12516" ], "database_specific": { "cwe_ids": [], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2020-12-10T03:15:00Z", "severity": "HIGH" }, "details": "Older firmware versions (FW1 up to FW10) of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack.", "id": "GHSA-wm2q-rjqh-v4ff", "modified": "2022-10-09T00:00:19Z", "published": "2022-05-24T17:35:50Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-12516" }, { "type": "WEB", "url": "https://cert.vde.com/en-us/advisories/vde-2020-042" }, { "type": "WEB", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-308-01" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "type": "CVSS_V3" } ] }
cve-2020-12516
Vulnerability from cvelistv5
Published
2020-12-10 03:04
Modified
2024-09-16 22:14
Severity ?
EPSS score ?
Summary
Older firmware versions (FW1 up to FW10) of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack.
References
▼ | URL | Tags |
---|---|---|
https://us-cert.cisa.gov/ics/advisories/icsa-20-308-01 | x_refsource_MISC | |
https://cert.vde.com/en-us/advisories/vde-2020-042 | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | WAGO | 750-331/xxx-xxx |
Version: FW1<=FW10 |
||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:56:52.085Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-308-01" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-042" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "750-331/xxx-xxx", "vendor": "WAGO", "versions": [ { "status": "affected", "version": "FW1\u003c=FW10" } ] }, { "product": "750-352", "vendor": "WAGO", "versions": [ { "status": "affected", "version": "FW1\u003c=FW10" } ] }, { "product": "750-829", "vendor": "WAGO", "versions": [ { "status": "affected", "version": "FW1\u003c=FW10" } ] }, { "product": "750-831/xxx-xxx", "vendor": "WAGO", "versions": [ { "status": "affected", "version": "FW1\u003c=FW10" } ] }, { "product": "750-852", "vendor": "WAGO", "versions": [ { "status": "affected", "version": "FW1\u003c=FW10" } ] }, { "product": "750-880/xxx-xxx", "vendor": "WAGO", "versions": [ { "status": "affected", "version": "FW1\u003c=FW10" } ] }, { "product": "750-881", "vendor": "WAGO", "versions": [ { "status": "affected", "version": "FW1\u003c=FW10" } ] }, { "product": "750-882", "vendor": "WAGO", "versions": [ { "status": "affected", "version": "FW1\u003c=FW10" } ] }, { "product": "750-885", "vendor": "WAGO", "versions": [ { "status": "affected", "version": "FW1\u003c=FW10" } ] }, { "product": "750-889", "vendor": "WAGO", "versions": [ { "status": "affected", "version": "FW1\u003c=FW10" } ] } ], "credits": [ { "lang": "en", "value": "These vulnerabilities were reported to WAGO by: William Knowles, Applied Risk. Coordination done by CERT@VDE." } ], "datePublic": "2020-12-09T00:00:00", "descriptions": [ { "lang": "en", "value": "Older firmware versions (FW1 up to FW10) of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400 Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-22T21:14:49", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-308-01" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert.vde.com/en-us/advisories/vde-2020-042" } ], "solutions": [ { "lang": "en", "value": "Update the device to the latest FW version." } ], "source": { "advisory": "VDE-2020-042", "defect": [ "VDE-2020-042" ], "discovery": "UNKNOWN" }, "title": "WAGO: PLC families 750-88x and 750-352 prone to DoS attack", "workarounds": [ { "lang": "en", "value": "Restrict network access to the device.\nDo not directly connect the device to the internet\nDisable unused TCP/UDP-ports" } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "AKA": "", "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2020-12-09T09:00:00.000Z", "ID": "CVE-2020-12516", "STATE": "PUBLIC", "TITLE": "WAGO: PLC families 750-88x and 750-352 prone to DoS attack" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "750-331/xxx-xxx", "version": { "version_data": [ { "version_value": "FW1\u003c=FW10" } ] } }, { "product_name": "750-352", "version": { "version_data": [ { "version_value": "FW1\u003c=FW10" } ] } }, { "product_name": "750-829", "version": { "version_data": [ { "version_value": "FW1\u003c=FW10" } ] } }, { "product_name": "750-831/xxx-xxx", "version": { "version_data": [ { "version_value": "FW1\u003c=FW10" } ] } }, { "product_name": "750-852", "version": { "version_data": [ { "version_value": "FW1\u003c=FW10" } ] } }, { "product_name": "750-880/xxx-xxx", "version": { "version_data": [ { "version_value": "FW1\u003c=FW10" } ] } }, { "product_name": "750-881", "version": { "version_data": [ { "version_value": "FW1\u003c=FW10" } ] } }, { "product_name": "750-882", "version": { "version_data": [ { "version_value": "FW1\u003c=FW10" } ] } }, { "product_name": "750-885", "version": { "version_data": [ { "version_value": "FW1\u003c=FW10" } ] } }, { "product_name": "750-889", "version": { "version_data": [ { "version_value": "FW1\u003c=FW10" } ] } } ] }, "vendor_name": "WAGO" } ] } }, "configuration": [], "credit": [ { "lang": "eng", "value": "These vulnerabilities were reported to WAGO by: William Knowles, Applied Risk. Coordination done by CERT@VDE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Older firmware versions (FW1 up to FW10) of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack." } ] }, "exploit": [], "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400 Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-308-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-308-01" }, { "name": "https://cert.vde.com/en-us/advisories/vde-2020-042", "refsource": "CONFIRM", "url": "https://cert.vde.com/en-us/advisories/vde-2020-042" } ] }, "solution": [ { "lang": "en", "value": "Update the device to the latest FW version." } ], "source": { "advisory": "VDE-2020-042", "defect": [ "VDE-2020-042" ], "discovery": "UNKNOWN" }, "work_around": [ { "lang": "en", "value": "Restrict network access to the device.\nDo not directly connect the device to the internet\nDisable unused TCP/UDP-ports" } ] } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2020-12516", "datePublished": "2020-12-10T03:04:17.186342Z", "dateReserved": "2020-04-30T00:00:00", "dateUpdated": "2024-09-16T22:14:10.360Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.