{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.224Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.0 and earlier",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V8.1",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
}
]
},
{
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
}
]
},
{
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V13",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V14",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Upd 9"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V15",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd 3"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V13",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V14",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1 Upd 8"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V15",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd 3"
}
]
},
{
"product": "SIMATIC WinCC V7.2 and earlier",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC V7.3",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.3 Upd 19"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Upd 11"
}
]
},
{
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 Upd 3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-23T19:28:02",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10917",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.0 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V8.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V8.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal) V13",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal) V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1 Upd 9"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Upd 3"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional V13",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14.1 Upd 8"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Upd 3"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.2 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.3 Upd 19"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.4 SP1 Upd 11"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.5 Upd 3"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10917",
"datePublished": "2019-05-14T19:54:48",
"dateReserved": "2019-04-08T00:00:00",
"dateUpdated": "2024-08-04T22:40:15.224Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}