fkie_cve-2023-46282
Vulnerability from fkie_nvd
Published
2023-12-12 12:15
Modified
2024-11-21 08:28
Severity ?
7.1 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Summary
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.
References
Impacted products
{ configurations: [ { nodes: [ { cpeMatch: [ { criteria: "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", matchCriteriaId: "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", matchCriteriaId: "96D49ACA-BF2E-4C89-8168-E4A95D5B22AA", versionEndExcluding: "4.1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", matchCriteriaId: "D882C3C8-EFE7-4DB6-B3E7-6152D7FEB74C", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", matchCriteriaId: "29E53F22-9086-40A2-85E0-20B58EC1E4BB", versionEndExcluding: "15", versionStartIncluding: "14.0", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", matchCriteriaId: "3F86DBB7-A5C7-43C4-8B64-0B67C90B79A8", versionEndExcluding: "16", versionStartIncluding: "15", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", matchCriteriaId: "B0BCF747-13ED-4AE7-9BE7-37858573AF27", versionEndExcluding: "17", versionStartIncluding: "16", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", matchCriteriaId: "C83587B9-53E2-4B2F-9FE4-5DDD232571F6", versionEndExcluding: "18", versionStartIncluding: "17", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", matchCriteriaId: "085B0B91-40DE-4328-A28C-1C920A6440D1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", matchCriteriaId: "68C7D9A3-9304-4A81-A970-717E5BA1ECF1", vulnerable: true, }, { criteria: "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", matchCriteriaId: "6A09C712-871D-4A81-A630-33BC5DF49FE5", vulnerable: true, }, ], negate: false, operator: "OR", }, ], }, ], cveTags: [], descriptions: [ { lang: "en", value: "A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.", }, { lang: "es", value: "Se ha identificado una vulnerabilidad en:\nOpcenter Quality (todas las versiones), \nSIMATIC PCS neo (todas las versiones < V4.1), \nSINUMERIK Integrate RunMyHMI /Automotive (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V14 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), \nTotally Integrated Automation Portal (TIA Portal) ) V18 (Todas las versiones ", }, ], id: "CVE-2023-46282", lastModified: "2024-11-21T08:28:13.473", metrics: { cvssMetricV31: [ { cvssData: { attackComplexity: "HIGH", attackVector: "NETWORK", availabilityImpact: "LOW", baseScore: 7.1, baseSeverity: "HIGH", confidentialityImpact: "HIGH", integrityImpact: "HIGH", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "REQUIRED", vectorString: "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L", version: "3.1", }, exploitabilityScore: 1.6, impactScore: 5.5, source: "productcert@siemens.com", type: "Secondary", }, { cvssData: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "NONE", baseScore: 6.1, baseSeverity: "MEDIUM", confidentialityImpact: "LOW", integrityImpact: "LOW", privilegesRequired: "NONE", scope: "CHANGED", userInteraction: "REQUIRED", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", version: "3.1", }, exploitabilityScore: 2.8, impactScore: 2.7, source: "nvd@nist.gov", type: "Primary", }, ], }, published: "2023-12-12T12:15:13.870", references: [ { source: "productcert@siemens.com", url: "https://cert-portal.siemens.com/productcert/html/ssa-999588.html", }, { source: "productcert@siemens.com", tags: [ "Patch", "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf", }, { source: "af854a3a-2127-422b-91ae-364da2661108", url: "https://cert-portal.siemens.com/productcert/html/ssa-999588.html", }, { source: "af854a3a-2127-422b-91ae-364da2661108", tags: [ "Patch", "Vendor Advisory", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf", }, ], sourceIdentifier: "productcert@siemens.com", vulnStatus: "Modified", weaknesses: [ { description: [ { lang: "en", value: "CWE-79", }, ], source: "productcert@siemens.com", type: "Secondary", }, { description: [ { lang: "en", value: "CWE-79", }, ], source: "nvd@nist.gov", type: "Primary", }, ], }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.