FKIE_CVE-2019-25720
Vulnerability from fkie_nvd - Published: 2026-06-03 18:16 - Updated: 2026-07-22 19:10
Severity
Summary
Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SC 6002XL",
"vendor": "Dr\u00e4ger",
"versions": [
{
"status": "affected",
"version": "SC 6002XL",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SC6802XL",
"vendor": "Dr\u00e4ger",
"versions": [
{
"status": "affected",
"version": "SC6802XL",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SC 7000",
"vendor": "Dr\u00e4ger",
"versions": [
{
"status": "affected",
"version": "SC 7000",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SC8000",
"vendor": "Dr\u00e4ger",
"versions": [
{
"status": "affected",
"version": "SC8000",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SC90000 XL",
"vendor": "Dr\u00e4ger",
"versions": [
{
"status": "affected",
"version": "SC90000 XL",
"versionType": "custom"
}
]
}
],
"source": "disclosure@vulncheck.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dr\u00e4ger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity."
},
{
"lang": "es",
"value": "Los dispositivos de monitorizaci\u00f3n Dr\u00e4ger SC (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contienen una vulnerabilidad de denegaci\u00f3n de servicio en todas las versiones de software que permite a atacantes no autenticados reiniciar el monitor enviando un paquete de red malformado. Los atacantes pueden enviar repetidamente dichos paquetes malformados para interrumpir la monitorizaci\u00f3n del paciente hasta que el dispositivo vuelve a la configuraci\u00f3n predeterminada y pierde la conectividad de red."
}
],
"id": "CVE-2019-25720",
"lastModified": "2026-07-22T19:10:00.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2019-25720",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-03T17:44:08.218138Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-06-03T18:16:15.910",
"references": [
{
"source": "disclosure@vulncheck.com",
"url": "https://static.draeger.com/security/download/2019-11-27-Draeger-SC7000-SC9000-security-advisory-update-v1-5.pdf"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.vulncheck.com/advisories/dr-ger-sc-monitoring-devices-dos-via-malformed-network-packet"
}
],
"sourceIdentifier": "disclosure@vulncheck.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-1286"
}
],
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Loading…
Loading…