CVE-2025-41768 (GCVE-0-2025-41768)

Vulnerability from cvelistv5 – Published: 2026-01-20 08:02 – Updated: 2026-02-12 09:00
VLAI?
Title
Beckhoff: XSS Vulnerability in TwinCAT 3 HMI Server
Summary
An high privileged remote attacker can inject arbitrary content into the custom CSS field on the affected devices due to improper neutralization of input during web page generation ('Cross-site Scripting').
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Beckhoff Automation TwinCAT.HMI.Server Affected: 0.0.0 , < 14.4.267 (semver)
Create a notification for this product.
Credits
Roby Firnando Yusuf from Jeonbuk National University
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41768",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-20T19:30:51.378202Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-20T19:32:34.439Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "TwinCAT.HMI.Server",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "14.4.267",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TF2000-HMI-Server",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "14.4.267",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "tf2000-hmi-server",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "14.4.267",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Roby Firnando Yusuf from Jeonbuk National University"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An high privileged remote attacker can inject arbitrary content into the custom CSS field on the affected devices due to improper neutralization of input during web page generation (\u0027Cross-site Scripting\u0027)."
            }
          ],
          "value": "An high privileged remote attacker can inject arbitrary content into the custom CSS field on the affected devices due to improper neutralization of input during web page generation (\u0027Cross-site Scripting\u0027)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-12T09:00:27.685Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-106"
        }
      ],
      "source": {
        "advisory": "VDE-2025-106",
        "defect": [
          "CERT@VDE#641900"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Beckhoff: XSS Vulnerability in TwinCAT 3 HMI Server",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41768",
    "datePublished": "2026-01-20T08:02:53.356Z",
    "dateReserved": "2025-04-16T11:18:45.761Z",
    "dateUpdated": "2026-02-12T09:00:27.685Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-41768\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2026-01-20T09:15:59.123\",\"lastModified\":\"2026-02-12T09:16:07.780\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An high privileged remote attacker can inject arbitrary content into the custom CSS field on the affected devices due to improper neutralization of input during web page generation (\u0027Cross-site Scripting\u0027).\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"references\":[{\"url\":\"https://certvde.com/de/advisories/VDE-2025-106\",\"source\":\"info@cert.vde.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-41768\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-01-20T19:30:51.378202Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-01-20T19:32:31.150Z\"}}], \"cna\": {\"title\": \"Beckhoff: XSS Vulnerability in TwinCAT 3 HMI Server\", \"source\": {\"defect\": [\"CERT@VDE#641900\"], \"advisory\": \"VDE-2025-106\", \"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Roby Firnando Yusuf from Jeonbuk National University\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 5.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Beckhoff Automation\", \"product\": \"TwinCAT.HMI.Server\", \"versions\": [{\"status\": \"affected\", \"version\": \"0.0.0\", \"lessThan\": \"14.4.267\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Beckhoff Automation\", \"product\": \"TF2000-HMI-Server\", \"versions\": [{\"status\": \"affected\", \"version\": \"0.0.0\", \"lessThan\": \"14.4.267\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Beckhoff Automation\", \"product\": \"tf2000-hmi-server\", \"versions\": [{\"status\": \"affected\", \"version\": \"0.0.0\", \"lessThan\": \"14.4.267\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://certvde.com/de/advisories/VDE-2025-106\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An high privileged remote attacker can inject arbitrary content into the custom CSS field on the affected devices due to improper neutralization of input during web page generation (\u0027Cross-site Scripting\u0027).\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"An high privileged remote attacker can inject arbitrary content into the custom CSS field on the affected devices due to improper neutralization of input during web page generation (\u0027Cross-site Scripting\u0027).\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"shortName\": \"CERTVDE\", \"dateUpdated\": \"2026-02-12T09:00:27.685Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-41768\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-02-12T09:00:27.685Z\", \"dateReserved\": \"2025-04-16T11:18:45.761Z\", \"assignerOrgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"datePublished\": \"2026-01-20T08:02:53.356Z\", \"assignerShortName\": \"CERTVDE\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…