cve-2025-22880
Vulnerability from cvelistv5
Published
2025-02-07 07:26
Modified
2025-02-07 15:54
Summary
Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
Impacted products
Vendor Product Version
Delta Electronics CNCSoft-G2 Version: 0   < 2.1.0.20
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22880",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-07T15:49:27.000208Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-07T15:54:27.041Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "CNCSoft-G2",
          "vendor": "Delta Electronics",
          "versions": [
            {
              "lessThan": "2.1.0.20",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2025-02-07T07:20:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-44",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-44 Overflow Binary Resource File"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122 Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-07T07:26:04.691Z",
        "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "shortName": "Deltaww"
      },
      "references": [
        {
          "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00002_CNCSoft-G2%20-%20Heap-based%20Buffer%20Overflow_v1.pdf"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\"\u003eCNCSoft-G2 V2.1.0.20\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.20 https://downloadcenter.deltaww.com/en-US/DownloadCenter \u00a0or later."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "timeline": [
        {
          "lang": "en",
          "time": "2024-09-28T06:24:00.000Z",
          "value": "Reported"
        },
        {
          "lang": "en",
          "time": "2024-12-04T06:26:00.000Z",
          "value": "New patch (CNCSoft-G2 v2.1.0.20) released"
        }
      ],
      "title": "Heap-based Buffer Overflow in CNCSoft-G2",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
    "assignerShortName": "Deltaww",
    "cveId": "CVE-2025-22880",
    "datePublished": "2025-02-07T07:26:04.691Z",
    "dateReserved": "2025-01-09T03:48:26.774Z",
    "dateUpdated": "2025-02-07T15:54:27.041Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-22880\",\"sourceIdentifier\":\"759f5e80-c8e1-4224-bead-956d7b33c98b\",\"published\":\"2025-02-07T08:15:28.737\",\"lastModified\":\"2025-02-07T08:15:28.737\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"759f5e80-c8e1-4224-bead-956d7b33c98b\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"759f5e80-c8e1-4224-bead-956d7b33c98b\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-122\"}]}],\"references\":[{\"url\":\"https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00002_CNCSoft-G2%20-%20Heap-based%20Buffer%20Overflow_v1.pdf\",\"source\":\"759f5e80-c8e1-4224-bead-956d7b33c98b\"}]}}",
    "vulnrichment": {
      "containers": "{\"cna\": {\"affected\": [{\"defaultStatus\": \"unaffected\", \"platforms\": [\"Windows\"], \"product\": \"CNCSoft-G2\", \"vendor\": \"Delta Electronics\", \"versions\": [{\"lessThan\": \"2.1.0.20\", \"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\"}]}], \"datePublic\": \"2025-02-07T07:20:00.000Z\", \"descriptions\": [{\"lang\": \"en\", \"supportingMedia\": [{\"base64\": false, \"type\": \"text/html\", \"value\": \"Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\"}], \"value\": \"Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.\"}], \"impacts\": [{\"capecId\": \"CAPEC-44\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-44 Overflow Binary Resource File\"}]}], \"metrics\": [{\"cvssV3_1\": {\"attackComplexity\": \"LOW\", \"attackVector\": \"LOCAL\", \"availabilityImpact\": \"HIGH\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"scope\": \"UNCHANGED\", \"userInteraction\": \"REQUIRED\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"version\": \"3.1\"}, \"format\": \"CVSS\", \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"problemTypes\": [{\"descriptions\": [{\"cweId\": \"CWE-122\", \"description\": \"CWE-122 Heap-based Buffer Overflow\", \"lang\": \"en\", \"type\": \"CWE\"}]}], \"providerMetadata\": {\"orgId\": \"759f5e80-c8e1-4224-bead-956d7b33c98b\", \"shortName\": \"Deltaww\", \"dateUpdated\": \"2025-02-07T07:26:04.691Z\"}, \"references\": [{\"url\": \"https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00002_CNCSoft-G2%20-%20Heap-based%20Buffer%20Overflow_v1.pdf\"}], \"solutions\": [{\"lang\": \"en\", \"supportingMedia\": [{\"base64\": false, \"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eDelta Electronics recommends users update to \u003c/span\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1\u0026amp;q=cncsoft\u0026amp;sort_expr=cdate\u0026amp;sort_dir=DESC\\\"\u003eCNCSoft-G2 V2.1.0.20\u003c/a\u003e\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\u0026nbsp;or later.\u003c/span\u003e\\n\\n\u003cbr\u003e\"}], \"value\": \"Delta Electronics recommends users update to  CNCSoft-G2 V2.1.0.20 https://downloadcenter.deltaww.com/en-US/DownloadCenter \\u00a0or later.\"}], \"source\": {\"discovery\": \"EXTERNAL\"}, \"timeline\": [{\"lang\": \"en\", \"time\": \"2024-09-28T06:24:00.000Z\", \"value\": \"Reported\"}, {\"lang\": \"en\", \"time\": \"2024-12-04T06:26:00.000Z\", \"value\": \"New patch (CNCSoft-G2 v2.1.0.20) released\"}], \"title\": \"Heap-based Buffer Overflow in CNCSoft-G2\", \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}}, \"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-22880\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-07T15:49:27.000208Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-07T15:49:28.454Z\"}}]}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-22880\", \"assignerOrgId\": \"759f5e80-c8e1-4224-bead-956d7b33c98b\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"Deltaww\", \"dateReserved\": \"2025-01-09T03:48:26.774Z\", \"datePublished\": \"2025-02-07T07:26:04.691Z\", \"dateUpdated\": \"2025-02-07T15:54:27.041Z\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.