Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2024-38879
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-857368.html | Mitigation, Vendor Advisory |
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Omnivise T3000 Application Server R9.2 |
Version: 0 < * |
|||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:omnivise_t3000_application_server:r9.2:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "omnivise_t3000_application_server", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "r9.2", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:omnivise_t3000:r8.2_sp3:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "omnivise_t3000", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "r8.2_sp3", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:omnivise_t3000:r8.2_sp4:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "omnivise_t3000", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "r8.2_sp4", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-38879", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-02T13:22:29.346191Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-14T20:47:43.341Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Omnivise T3000 Application Server R9.2", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Omnivise T3000 R8.2 SP3", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Omnivise T3000 R8.2 SP4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-13T07:54:16.146Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-857368.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-38879", "datePublished": "2024-08-02T10:36:20.639Z", "dateReserved": "2024-06-21T08:28:10.678Z", "dateUpdated": "2024-08-14T20:47:43.341Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-38879\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-08-02T11:16:42.510\",\"lastModified\":\"2024-09-20T23:26:28.767\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application.\"},{\"lang\":\"es\",\"value\":\" Se ha identificado una vulnerabilidad en Omnivise T3000 Application Server (todas las versiones). El sistema afectado expone el puerto de una aplicaci\u00f3n interna en la interfaz de la red p\u00fablica, lo que permite a un atacante omitir la autenticaci\u00f3n y acceder directamente a la aplicaci\u00f3n expuesta.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"HIGH\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"NONE\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:omnivise_t3000_application_server:8.2:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"DAF50AB8-06BA-4CB7-AA0F-9BA908079FCA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:omnivise_t3000_application_server:8.2:sp4:*:*:*:*:*:*\",\"matchCriteriaId\":\"0B9DE993-8A95-47B5-B192-8985A9C718D0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:omnivise_t3000_application_server:9.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EAE3C15D-4E9D-4A7F-930A-938F43D1AAD5\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-857368.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-38879\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-08-02T13:22:29.346191Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:siemens:omnivise_t3000_application_server:r9.2:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"omnivise_t3000_application_server\", \"versions\": [{\"status\": \"affected\", \"version\": \"r9.2\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"*\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:siemens:omnivise_t3000:r8.2_sp3:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"omnivise_t3000\", \"versions\": [{\"status\": \"affected\", \"version\": \"r8.2_sp3\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"*\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:siemens:omnivise_t3000:r8.2_sp4:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"omnivise_t3000\", \"versions\": [{\"status\": \"affected\", \"version\": \"r8.2_sp4\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"*\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-02T13:35:44.023Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"Omnivise T3000 Application Server R9.2\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Omnivise T3000 R8.2 SP3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Omnivise T3000 R8.2 SP4\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-857368.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20: Improper Input Validation\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2024-08-13T07:54:16.146Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2024-38879\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-14T20:47:43.341Z\", \"dateReserved\": \"2024-06-21T08:28:10.678Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2024-08-02T10:36:20.639Z\", \"assignerShortName\": \"siemens\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
ncsc-2024-0323
Vulnerability from csaf_ncscnl
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE" } }, "lang": "nl", "notes": [ { "category": "legal_disclaimer", "text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings." }, { "category": "description", "text": "Siemens Energy heeft kwetsbaarheden verholpen in Omnivise T3000.", "title": "Feiten" }, { "category": "description", "text": "Een kwaadwillende kan de kwetsbaarheden misbruiken om zich verhoogde rechten toe te kennen op het kwetsbare systeem en daarmee willekeurige code uit te voeren, mogelijk met systeemrechten. \n\nVoor succesvol misbruik moet de kwaadwillende lokaal geautoriseerd zijn. Echter, omdat de kwetsbaarheid met kenmerk CVE-2024-38879 een poort van een intern proces beschikbaar stelt op het netwerk, is het mogelijk dat de kwaadwillende op afstand de kwetsbaarheden in keten kan misbruiken.\nHiervoor dient te kwaadwillende wel toegang te hebben tot de productie-omgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.", "title": "Interpretaties" }, { "category": "description", "text": "Siemens heeft updates uitgebracht om de kwetsbaarheden te verhelpen. Zie bijgevoegde referenties voor meer informatie.", "title": "Oplossingen" }, { "category": "general", "text": "medium", "title": "Kans" }, { "category": "general", "text": "high", "title": "Schade" }, { "category": "general", "text": "Improper Input Validation", "title": "CWE-20" }, { "category": "general", "text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "title": "CWE-22" }, { "category": "general", "text": "Improper Authentication", "title": "CWE-287" }, { "category": "general", "text": "Cleartext Storage of Sensitive Information", "title": "CWE-312" }, { "category": "general", "text": "Files or Directories Accessible to External Parties", "title": "CWE-552" } ], "publisher": { "category": "coordinator", "contact_details": "cert@ncsc.nl", "name": "Nationaal Cyber Security Centrum", "namespace": "https://www.ncsc.nl/" }, "references": [ { "category": "external", "summary": "Reference - cveprojectv5; nvd", "url": "https://cert-portal.siemens.com/productcert/html/ssa-857368.html" } ], "title": "Kwetsbaarheden verholpen in Siemens Omnivise", "tracking": { "current_release_date": "2024-08-06T09:29:53.292433Z", "id": "NCSC-2024-0323", "initial_release_date": "2024-08-06T09:29:53.292433Z", "revision_history": [ { "date": "2024-08-06T09:29:53.292433Z", "number": "0", "summary": "Initiele versie" } ], "status": "final", "version": "1.0.0" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "omnivise_t3000_application_server", "product": { "name": "omnivise_t3000_application_server", "product_id": "CSAFPID-1532010", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_application_server:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_application_server", "product": { "name": "omnivise_t3000_application_server", "product_id": "CSAFPID-1533376", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_application_server:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_application_server", "product": { "name": "omnivise_t3000_application_server", "product_id": "CSAFPID-1531991", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_application_server:9.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_application_server", "product": { "name": "omnivise_t3000_application_server", "product_id": "CSAFPID-1531992", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_application_server:9.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_application_server", "product": { "name": "omnivise_t3000_application_server", "product_id": "CSAFPID-1531993", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_application_server:9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_application_server", "product": { "name": "omnivise_t3000_application_server", "product_id": "CSAFPID-1533070", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_application_server:r9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_domain_controller", "product": { "name": "omnivise_t3000_domain_controller", "product_id": "CSAFPID-1532011", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_domain_controller:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_domain_controller", "product": { "name": "omnivise_t3000_domain_controller", "product_id": "CSAFPID-1536176", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_domain_controller:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_domain_controller", "product": { "name": "omnivise_t3000_domain_controller", "product_id": "CSAFPID-1531994", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_domain_controller:9.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_domain_controller", "product": { "name": "omnivise_t3000_domain_controller", "product_id": "CSAFPID-1531995", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_domain_controller:9.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_domain_controller", "product": { "name": "omnivise_t3000_domain_controller", "product_id": "CSAFPID-1531996", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_domain_controller:9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_domain_controller", "product": { "name": "omnivise_t3000_domain_controller", "product_id": "CSAFPID-1533071", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_domain_controller:r9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_network_intrusion_detection_system__nids_", "product": { "name": "omnivise_t3000_network_intrusion_detection_system__nids_", "product_id": "CSAFPID-1536177", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_network_intrusion_detection_system__nids_:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_network_intrusion_detection_system_nids_", "product": { "name": "omnivise_t3000_network_intrusion_detection_system_nids_", "product_id": "CSAFPID-1532012", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_network_intrusion_detection_system_nids_:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_product_data_management__pdm_", "product": { "name": "omnivise_t3000_product_data_management__pdm_", "product_id": "CSAFPID-1536178", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_product_data_management__pdm_:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_product_data_management__pdm_", "product": { "name": "omnivise_t3000_product_data_management__pdm_", "product_id": "CSAFPID-1533072", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_product_data_management__pdm_:r9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_product_data_management_pdm_", "product": { "name": "omnivise_t3000_product_data_management_pdm_", "product_id": "CSAFPID-1532013", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_product_data_management_pdm_:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_product_data_management_pdm_", "product": { "name": "omnivise_t3000_product_data_management_pdm_", "product_id": "CSAFPID-1531997", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_product_data_management_pdm_:9.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_product_data_management_pdm_", "product": { "name": "omnivise_t3000_product_data_management_pdm_", "product_id": "CSAFPID-1531998", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_product_data_management_pdm_:9.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_product_data_management_pdm_", "product": { "name": "omnivise_t3000_product_data_management_pdm_", "product_id": "CSAFPID-1531999", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_product_data_management_pdm_:9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_security_server", "product": { "name": "omnivise_t3000_security_server", "product_id": "CSAFPID-1532014", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_security_server:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_security_server", "product": { "name": "omnivise_t3000_security_server", "product_id": "CSAFPID-1536179", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_security_server:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_terminal_server", "product": { "name": "omnivise_t3000_terminal_server", "product_id": "CSAFPID-1532015", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_terminal_server:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_terminal_server", "product": { "name": "omnivise_t3000_terminal_server", "product_id": "CSAFPID-1536180", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_terminal_server:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_terminal_server", "product": { "name": "omnivise_t3000_terminal_server", "product_id": "CSAFPID-1532000", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_terminal_server:9.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_terminal_server", "product": { "name": "omnivise_t3000_terminal_server", "product_id": "CSAFPID-1532001", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_terminal_server:9.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_terminal_server", "product": { "name": "omnivise_t3000_terminal_server", "product_id": "CSAFPID-1532002", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_terminal_server:9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_terminal_server", "product": { "name": "omnivise_t3000_terminal_server", "product_id": "CSAFPID-1533073", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_terminal_server:r9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_thin_client", "product": { "name": "omnivise_t3000_thin_client", "product_id": "CSAFPID-1532016", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_thin_client:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_thin_client", "product": { "name": "omnivise_t3000_thin_client", "product_id": "CSAFPID-1536181", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_thin_client:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_thin_client", "product": { "name": "omnivise_t3000_thin_client", "product_id": "CSAFPID-1532003", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_thin_client:9.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_thin_client", "product": { "name": "omnivise_t3000_thin_client", "product_id": "CSAFPID-1532004", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_thin_client:9.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_thin_client", "product": { "name": "omnivise_t3000_thin_client", "product_id": "CSAFPID-1532005", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_thin_client:9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_thin_client", "product": { "name": "omnivise_t3000_thin_client", "product_id": "CSAFPID-1533074", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_thin_client:r9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_whitelisting_server", "product": { "name": "omnivise_t3000_whitelisting_server", "product_id": "CSAFPID-1532017", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_whitelisting_server:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_whitelisting_server", "product": { "name": "omnivise_t3000_whitelisting_server", "product_id": "CSAFPID-1536182", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_whitelisting_server:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_whitelisting_server", "product": { "name": "omnivise_t3000_whitelisting_server", "product_id": "CSAFPID-1532006", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_whitelisting_server:9.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_whitelisting_server", "product": { "name": "omnivise_t3000_whitelisting_server", "product_id": "CSAFPID-1532007", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_whitelisting_server:9.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_whitelisting_server", "product": { "name": "omnivise_t3000_whitelisting_server", "product_id": "CSAFPID-1532008", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_whitelisting_server:9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_whitelisting_server", "product": { "name": "omnivise_t3000_whitelisting_server", "product_id": "CSAFPID-1533075", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_whitelisting_server:r9.2:*:*:*:*:*:*:*" } } } ], "category": "vendor", "name": "siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-38876", "cwe": { "id": "CWE-552", "name": "Files or Directories Accessible to External Parties" }, "notes": [ { "category": "other", "text": "Files or Directories Accessible to External Parties", "title": "CWE-552" } ], "product_status": { "known_affected": [ "CSAFPID-1533070", "CSAFPID-1533071", "CSAFPID-1533072", "CSAFPID-1533073", "CSAFPID-1533074", "CSAFPID-1533075" ] }, "references": [ { "category": "self", "summary": "CVE-2024-38876", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38876.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1533070", "CSAFPID-1533071", "CSAFPID-1533072", "CSAFPID-1533073", "CSAFPID-1533074", "CSAFPID-1533075" ] } ], "title": "CVE-2024-38876" }, { "cve": "CVE-2024-38877", "cwe": { "id": "CWE-312", "name": "Cleartext Storage of Sensitive Information" }, "notes": [ { "category": "other", "text": "Cleartext Storage of Sensitive Information", "title": "CWE-312" } ], "product_status": { "known_affected": [ "CSAFPID-1533376", "CSAFPID-1536176", "CSAFPID-1536177", "CSAFPID-1536178", "CSAFPID-1536179", "CSAFPID-1536180", "CSAFPID-1536181", "CSAFPID-1536182" ] }, "references": [ { "category": "self", "summary": "CVE-2024-38877", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38877.json" } ], "scores": [ { "cvss_v3": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1533376", "CSAFPID-1536176", "CSAFPID-1536177", "CSAFPID-1536178", "CSAFPID-1536179", "CSAFPID-1536180", "CSAFPID-1536181", "CSAFPID-1536182" ] } ], "title": "CVE-2024-38877" }, { "cve": "CVE-2024-38878", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "other", "text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "title": "CWE-22" } ], "product_status": { "known_affected": [ "CSAFPID-1533376" ] }, "references": [ { "category": "self", "summary": "CVE-2024-38878", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38878.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1533376" ] } ], "title": "CVE-2024-38878" }, { "cve": "CVE-2024-38879", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "other", "text": "Improper Authentication", "title": "CWE-287" }, { "category": "other", "text": "Improper Input Validation", "title": "CWE-20" } ], "product_status": { "known_affected": [ "CSAFPID-1533376" ] }, "references": [ { "category": "self", "summary": "CVE-2024-38879", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38879.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "products": [ "CSAFPID-1533376" ] } ], "title": "CVE-2024-38879" } ] }
NCSC-2024-0323
Vulnerability from csaf_ncscnl
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE" } }, "lang": "nl", "notes": [ { "category": "legal_disclaimer", "text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings." }, { "category": "description", "text": "Siemens Energy heeft kwetsbaarheden verholpen in Omnivise T3000.", "title": "Feiten" }, { "category": "description", "text": "Een kwaadwillende kan de kwetsbaarheden misbruiken om zich verhoogde rechten toe te kennen op het kwetsbare systeem en daarmee willekeurige code uit te voeren, mogelijk met systeemrechten. \n\nVoor succesvol misbruik moet de kwaadwillende lokaal geautoriseerd zijn. Echter, omdat de kwetsbaarheid met kenmerk CVE-2024-38879 een poort van een intern proces beschikbaar stelt op het netwerk, is het mogelijk dat de kwaadwillende op afstand de kwetsbaarheden in keten kan misbruiken.\nHiervoor dient te kwaadwillende wel toegang te hebben tot de productie-omgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.", "title": "Interpretaties" }, { "category": "description", "text": "Siemens heeft updates uitgebracht om de kwetsbaarheden te verhelpen. Zie bijgevoegde referenties voor meer informatie.", "title": "Oplossingen" }, { "category": "general", "text": "medium", "title": "Kans" }, { "category": "general", "text": "high", "title": "Schade" }, { "category": "general", "text": "Improper Input Validation", "title": "CWE-20" }, { "category": "general", "text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "title": "CWE-22" }, { "category": "general", "text": "Improper Authentication", "title": "CWE-287" }, { "category": "general", "text": "Cleartext Storage of Sensitive Information", "title": "CWE-312" }, { "category": "general", "text": "Files or Directories Accessible to External Parties", "title": "CWE-552" } ], "publisher": { "category": "coordinator", "contact_details": "cert@ncsc.nl", "name": "Nationaal Cyber Security Centrum", "namespace": "https://www.ncsc.nl/" }, "references": [ { "category": "external", "summary": "Reference - cveprojectv5; nvd", "url": "https://cert-portal.siemens.com/productcert/html/ssa-857368.html" } ], "title": "Kwetsbaarheden verholpen in Siemens Omnivise", "tracking": { "current_release_date": "2024-08-06T09:29:53.292433Z", "id": "NCSC-2024-0323", "initial_release_date": "2024-08-06T09:29:53.292433Z", "revision_history": [ { "date": "2024-08-06T09:29:53.292433Z", "number": "0", "summary": "Initiele versie" } ], "status": "final", "version": "1.0.0" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "omnivise_t3000_application_server", "product": { "name": "omnivise_t3000_application_server", "product_id": "CSAFPID-1532010", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_application_server:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_application_server", "product": { "name": "omnivise_t3000_application_server", "product_id": "CSAFPID-1533376", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_application_server:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_application_server", "product": { "name": "omnivise_t3000_application_server", "product_id": "CSAFPID-1531991", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_application_server:9.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_application_server", "product": { "name": "omnivise_t3000_application_server", "product_id": "CSAFPID-1531992", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_application_server:9.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_application_server", "product": { "name": "omnivise_t3000_application_server", "product_id": "CSAFPID-1531993", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_application_server:9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_application_server", "product": { "name": "omnivise_t3000_application_server", "product_id": "CSAFPID-1533070", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_application_server:r9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_domain_controller", "product": { "name": "omnivise_t3000_domain_controller", "product_id": "CSAFPID-1532011", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_domain_controller:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_domain_controller", "product": { "name": "omnivise_t3000_domain_controller", "product_id": "CSAFPID-1536176", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_domain_controller:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_domain_controller", "product": { "name": "omnivise_t3000_domain_controller", "product_id": "CSAFPID-1531994", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_domain_controller:9.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_domain_controller", "product": { "name": "omnivise_t3000_domain_controller", "product_id": "CSAFPID-1531995", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_domain_controller:9.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_domain_controller", "product": { "name": "omnivise_t3000_domain_controller", "product_id": "CSAFPID-1531996", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_domain_controller:9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_domain_controller", "product": { "name": "omnivise_t3000_domain_controller", "product_id": "CSAFPID-1533071", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_domain_controller:r9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_network_intrusion_detection_system__nids_", "product": { "name": "omnivise_t3000_network_intrusion_detection_system__nids_", "product_id": "CSAFPID-1536177", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_network_intrusion_detection_system__nids_:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_network_intrusion_detection_system_nids_", "product": { "name": "omnivise_t3000_network_intrusion_detection_system_nids_", "product_id": "CSAFPID-1532012", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_network_intrusion_detection_system_nids_:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_product_data_management__pdm_", "product": { "name": "omnivise_t3000_product_data_management__pdm_", "product_id": "CSAFPID-1536178", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_product_data_management__pdm_:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_product_data_management__pdm_", "product": { "name": "omnivise_t3000_product_data_management__pdm_", "product_id": "CSAFPID-1533072", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_product_data_management__pdm_:r9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_product_data_management_pdm_", "product": { "name": "omnivise_t3000_product_data_management_pdm_", "product_id": "CSAFPID-1532013", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_product_data_management_pdm_:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_product_data_management_pdm_", "product": { "name": "omnivise_t3000_product_data_management_pdm_", "product_id": "CSAFPID-1531997", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_product_data_management_pdm_:9.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_product_data_management_pdm_", "product": { "name": "omnivise_t3000_product_data_management_pdm_", "product_id": "CSAFPID-1531998", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_product_data_management_pdm_:9.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_product_data_management_pdm_", "product": { "name": "omnivise_t3000_product_data_management_pdm_", "product_id": "CSAFPID-1531999", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_product_data_management_pdm_:9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_security_server", "product": { "name": "omnivise_t3000_security_server", "product_id": "CSAFPID-1532014", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_security_server:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_security_server", "product": { "name": "omnivise_t3000_security_server", "product_id": "CSAFPID-1536179", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_security_server:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_terminal_server", "product": { "name": "omnivise_t3000_terminal_server", "product_id": "CSAFPID-1532015", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_terminal_server:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_terminal_server", "product": { "name": "omnivise_t3000_terminal_server", "product_id": "CSAFPID-1536180", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_terminal_server:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_terminal_server", "product": { "name": "omnivise_t3000_terminal_server", "product_id": "CSAFPID-1532000", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_terminal_server:9.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_terminal_server", "product": { "name": "omnivise_t3000_terminal_server", "product_id": "CSAFPID-1532001", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_terminal_server:9.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_terminal_server", "product": { "name": "omnivise_t3000_terminal_server", "product_id": "CSAFPID-1532002", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_terminal_server:9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_terminal_server", "product": { "name": "omnivise_t3000_terminal_server", "product_id": "CSAFPID-1533073", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_terminal_server:r9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_thin_client", "product": { "name": "omnivise_t3000_thin_client", "product_id": "CSAFPID-1532016", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_thin_client:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_thin_client", "product": { "name": "omnivise_t3000_thin_client", "product_id": "CSAFPID-1536181", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_thin_client:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_thin_client", "product": { "name": "omnivise_t3000_thin_client", "product_id": "CSAFPID-1532003", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_thin_client:9.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_thin_client", "product": { "name": "omnivise_t3000_thin_client", "product_id": "CSAFPID-1532004", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_thin_client:9.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_thin_client", "product": { "name": "omnivise_t3000_thin_client", "product_id": "CSAFPID-1532005", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_thin_client:9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_thin_client", "product": { "name": "omnivise_t3000_thin_client", "product_id": "CSAFPID-1533074", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_thin_client:r9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_whitelisting_server", "product": { "name": "omnivise_t3000_whitelisting_server", "product_id": "CSAFPID-1532017", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_whitelisting_server:*:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_whitelisting_server", "product": { "name": "omnivise_t3000_whitelisting_server", "product_id": "CSAFPID-1536182", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_whitelisting_server:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_whitelisting_server", "product": { "name": "omnivise_t3000_whitelisting_server", "product_id": "CSAFPID-1532006", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_whitelisting_server:9.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_whitelisting_server", "product": { "name": "omnivise_t3000_whitelisting_server", "product_id": "CSAFPID-1532007", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_whitelisting_server:9.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_whitelisting_server", "product": { "name": "omnivise_t3000_whitelisting_server", "product_id": "CSAFPID-1532008", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_whitelisting_server:9.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "omnivise_t3000_whitelisting_server", "product": { "name": "omnivise_t3000_whitelisting_server", "product_id": "CSAFPID-1533075", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:omnivise_t3000_whitelisting_server:r9.2:*:*:*:*:*:*:*" } } } ], "category": "vendor", "name": "siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-38876", "cwe": { "id": "CWE-552", "name": "Files or Directories Accessible to External Parties" }, "notes": [ { "category": "other", "text": "Files or Directories Accessible to External Parties", "title": "CWE-552" } ], "product_status": { "known_affected": [ "CSAFPID-1533070", "CSAFPID-1533071", "CSAFPID-1533072", "CSAFPID-1533073", "CSAFPID-1533074", "CSAFPID-1533075" ] }, "references": [ { "category": "self", "summary": "CVE-2024-38876", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38876.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1533070", "CSAFPID-1533071", "CSAFPID-1533072", "CSAFPID-1533073", "CSAFPID-1533074", "CSAFPID-1533075" ] } ], "title": "CVE-2024-38876" }, { "cve": "CVE-2024-38877", "cwe": { "id": "CWE-312", "name": "Cleartext Storage of Sensitive Information" }, "notes": [ { "category": "other", "text": "Cleartext Storage of Sensitive Information", "title": "CWE-312" } ], "product_status": { "known_affected": [ "CSAFPID-1533376", "CSAFPID-1536176", "CSAFPID-1536177", "CSAFPID-1536178", "CSAFPID-1536179", "CSAFPID-1536180", "CSAFPID-1536181", "CSAFPID-1536182" ] }, "references": [ { "category": "self", "summary": "CVE-2024-38877", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38877.json" } ], "scores": [ { "cvss_v3": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1533376", "CSAFPID-1536176", "CSAFPID-1536177", "CSAFPID-1536178", "CSAFPID-1536179", "CSAFPID-1536180", "CSAFPID-1536181", "CSAFPID-1536182" ] } ], "title": "CVE-2024-38877" }, { "cve": "CVE-2024-38878", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "other", "text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "title": "CWE-22" } ], "product_status": { "known_affected": [ "CSAFPID-1533376" ] }, "references": [ { "category": "self", "summary": "CVE-2024-38878", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38878.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1533376" ] } ], "title": "CVE-2024-38878" }, { "cve": "CVE-2024-38879", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "other", "text": "Improper Authentication", "title": "CWE-287" }, { "category": "other", "text": "Improper Input Validation", "title": "CWE-20" } ], "product_status": { "known_affected": [ "CSAFPID-1533376" ] }, "references": [ { "category": "self", "summary": "CVE-2024-38879", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38879.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "products": [ "CSAFPID-1533376" ] } ], "title": "CVE-2024-38879" } ] }
ghsa-4h47-46m8-cx7g
Vulnerability from github
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
A vulnerability has been identified in Omnivise T3000 Application Server (All versions). The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application.
{ "affected": [], "aliases": [ "CVE-2024-38879" ], "database_specific": { "cwe_ids": [ "CWE-20" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2024-08-02T11:16:42Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in Omnivise\u00a0T3000 Application Server (All versions). The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application.", "id": "GHSA-4h47-46m8-cx7g", "modified": "2024-09-21T00:34:48Z", "published": "2024-08-02T12:31:43Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-38879" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-857368.html" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "type": "CVSS_V3" }, { "score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "type": "CVSS_V4" } ] }
ssa-857368
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Omnivise T3000 contains multiple vulnerabilities that could allow an attacker to escalate privileges.\n\nSiemens Energy has released patches for several affected products and recommends to apply the patches. Siemens Energy is preparing further fixes for versions still under maintenance and recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure Siemens Energy strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-857368: Multiple Vulnerabilities in Omnivise T3000 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-857368.html" }, { "category": "self", "summary": "SSA-857368: Multiple Vulnerabilities in Omnivise T3000 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-857368.json" } ], "title": "SSA-857368: Multiple Vulnerabilities in Omnivise T3000", "tracking": { "current_release_date": "2024-08-13T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-857368", "initial_release_date": "2024-08-02T00:00:00Z", "revision_history": [ { "date": "2024-08-02T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-08-13T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added additional affected Omnivise T3000 Releases R8.2 SP3 and SP4, corrected inconsistent information, added reference to SE Controls Security Announcement 2024-01" } ], "status": "interim", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Application Server R9.2", "product_id": "1" } } ], "category": "product_name", "name": "Omnivise T3000 Application Server R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Domain Controller R9.2", "product_id": "2" } } ], "category": "product_name", "name": "Omnivise T3000 Domain Controller R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Network Intrusion Detection System (NIDS) R9.2", "product_id": "3" } } ], "category": "product_name", "name": "Omnivise T3000 Network Intrusion Detection System (NIDS) R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Product Data Management (PDM) R9.2", "product_id": "4" } } ], "category": "product_name", "name": "Omnivise T3000 Product Data Management (PDM) R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 R8.2 SP3", "product_id": "5" } } ], "category": "product_name", "name": "Omnivise T3000 R8.2 SP3" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 R8.2 SP4", "product_id": "6" } } ], "category": "product_name", "name": "Omnivise T3000 R8.2 SP4" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Security Server R9.2", "product_id": "7" } } ], "category": "product_name", "name": "Omnivise T3000 Security Server R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Terminal Server R9.2", "product_id": "8" } } ], "category": "product_name", "name": "Omnivise T3000 Terminal Server R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Thin Client R9.2", "product_id": "9" } } ], "category": "product_name", "name": "Omnivise T3000 Thin Client R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Whitelisting Server R9.2", "product_id": "10" } } ], "category": "product_name", "name": "Omnivise T3000 Whitelisting Server R9.2" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-38876", "cwe": { "id": "CWE-552", "name": "Files or Directories Accessible to External Parties" }, "notes": [ { "category": "summary", "text": "The affected application regularly executes user modifiable code as a privileged user. This could allow a local authenticated attacker to execute arbitrary code with elevated privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "4", "5", "6", "8", "9", "10" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.20 and System Software Patch 22.173.52; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "2", "4", "8", "9", "10" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.20 and System Software Patch 22.173.52 as well as Application Software Patch 09.0.19.06; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "1", "2", "4", "5", "6", "8", "9", "10" ] } ], "title": "CVE-2024-38876" }, { "cve": "CVE-2024-38877", "cwe": { "id": "CWE-312", "name": "Cleartext Storage of Sensitive Information" }, "notes": [ { "category": "summary", "text": "The affected devices stores initial system credentials without sufficient protection. An attacker with remote shell access or physical access could retrieve the credentials leading to confidentiality loss allowing the attacker to laterally move within the affected network.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10" ] }, "remediations": [ { "category": "mitigation", "details": "If the passwords are suspected to be compromised, change the Passwords for all computers and service accounts. In addition follow the instructions from Omnivise T3000 Technical News 2024-089 which is available through T3000 customer service and applies to releases (8.2 SP3/SP4 and 9.2).", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.20 and System Software Patch 22.173.52; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "2", "4", "8", "9", "10" ] }, { "category": "vendor_fix", "details": "Apply mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "3" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.52; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "7" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.20 and System Software Patch 22.173.52 as well as Application Software Patch 09.0.19.06; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10" ] } ], "title": "CVE-2024-38877" }, { "cve": "CVE-2024-38878", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices allow authenticated users to export diagnostics data. The corresponding API endpoint is susceptible to path traversal and could allow an authenticated attacker to download arbitrary files from the file system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "5", "6" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.20 and System Software Patch 22.173.52 as well as Application Software Patch 09.0.19.06; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "5", "6" ] } ], "title": "CVE-2024-38878" }, { "cve": "CVE-2024-38879", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "5", "6" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.20 and System Software Patch 22.173.52 as well as Application Software Patch 09.0.19.06; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "5", "6" ] } ], "title": "CVE-2024-38879" } ] }
SSA-857368
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Omnivise T3000 contains multiple vulnerabilities that could allow an attacker to escalate privileges.\n\nSiemens Energy has released patches for several affected products and recommends to apply the patches. Siemens Energy is preparing further fixes for versions still under maintenance and recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure Siemens Energy strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-857368: Multiple Vulnerabilities in Omnivise T3000 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-857368.html" }, { "category": "self", "summary": "SSA-857368: Multiple Vulnerabilities in Omnivise T3000 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-857368.json" } ], "title": "SSA-857368: Multiple Vulnerabilities in Omnivise T3000", "tracking": { "current_release_date": "2024-08-13T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-857368", "initial_release_date": "2024-08-02T00:00:00Z", "revision_history": [ { "date": "2024-08-02T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-08-13T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added additional affected Omnivise T3000 Releases R8.2 SP3 and SP4, corrected inconsistent information, added reference to SE Controls Security Announcement 2024-01" } ], "status": "interim", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Application Server R9.2", "product_id": "1" } } ], "category": "product_name", "name": "Omnivise T3000 Application Server R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Domain Controller R9.2", "product_id": "2" } } ], "category": "product_name", "name": "Omnivise T3000 Domain Controller R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Network Intrusion Detection System (NIDS) R9.2", "product_id": "3" } } ], "category": "product_name", "name": "Omnivise T3000 Network Intrusion Detection System (NIDS) R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Product Data Management (PDM) R9.2", "product_id": "4" } } ], "category": "product_name", "name": "Omnivise T3000 Product Data Management (PDM) R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 R8.2 SP3", "product_id": "5" } } ], "category": "product_name", "name": "Omnivise T3000 R8.2 SP3" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 R8.2 SP4", "product_id": "6" } } ], "category": "product_name", "name": "Omnivise T3000 R8.2 SP4" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Security Server R9.2", "product_id": "7" } } ], "category": "product_name", "name": "Omnivise T3000 Security Server R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Terminal Server R9.2", "product_id": "8" } } ], "category": "product_name", "name": "Omnivise T3000 Terminal Server R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Thin Client R9.2", "product_id": "9" } } ], "category": "product_name", "name": "Omnivise T3000 Thin Client R9.2" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Omnivise T3000 Whitelisting Server R9.2", "product_id": "10" } } ], "category": "product_name", "name": "Omnivise T3000 Whitelisting Server R9.2" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-38876", "cwe": { "id": "CWE-552", "name": "Files or Directories Accessible to External Parties" }, "notes": [ { "category": "summary", "text": "The affected application regularly executes user modifiable code as a privileged user. This could allow a local authenticated attacker to execute arbitrary code with elevated privileges.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "4", "5", "6", "8", "9", "10" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.20 and System Software Patch 22.173.52; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "2", "4", "8", "9", "10" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.20 and System Software Patch 22.173.52 as well as Application Software Patch 09.0.19.06; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "1", "2", "4", "5", "6", "8", "9", "10" ] } ], "title": "CVE-2024-38876" }, { "cve": "CVE-2024-38877", "cwe": { "id": "CWE-312", "name": "Cleartext Storage of Sensitive Information" }, "notes": [ { "category": "summary", "text": "The affected devices stores initial system credentials without sufficient protection. An attacker with remote shell access or physical access could retrieve the credentials leading to confidentiality loss allowing the attacker to laterally move within the affected network.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10" ] }, "remediations": [ { "category": "mitigation", "details": "If the passwords are suspected to be compromised, change the Passwords for all computers and service accounts. In addition follow the instructions from Omnivise T3000 Technical News 2024-089 which is available through T3000 customer service and applies to releases (8.2 SP3/SP4 and 9.2).", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.20 and System Software Patch 22.173.52; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "2", "4", "8", "9", "10" ] }, { "category": "vendor_fix", "details": "Apply mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "3" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.52; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "7" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.20 and System Software Patch 22.173.52 as well as Application Software Patch 09.0.19.06; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10" ] } ], "title": "CVE-2024-38877" }, { "cve": "CVE-2024-38878", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "summary", "text": "Affected devices allow authenticated users to export diagnostics data. The corresponding API endpoint is susceptible to path traversal and could allow an authenticated attacker to download arbitrary files from the file system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "5", "6" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.20 and System Software Patch 22.173.52 as well as Application Software Patch 09.0.19.06; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "5", "6" ] } ], "title": "CVE-2024-38878" }, { "cve": "CVE-2024-38879", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "5", "6" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "5" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "6" ] }, { "category": "vendor_fix", "details": "Install System Software Patch 22.173.20 and System Software Patch 22.173.52 as well as Application Software Patch 09.0.19.06; apply additional mitigations from Omnivise T3000 Technical News 2024-089", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "5", "6" ] } ], "title": "CVE-2024-38879" } ] }
fkie_cve-2024-38879
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-857368.html | Mitigation, Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
siemens | omnivise_t3000_application_server | 8.2 | |
siemens | omnivise_t3000_application_server | 8.2 | |
siemens | omnivise_t3000_application_server | 9.2 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:omnivise_t3000_application_server:8.2:sp3:*:*:*:*:*:*", "matchCriteriaId": "DAF50AB8-06BA-4CB7-AA0F-9BA908079FCA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:omnivise_t3000_application_server:8.2:sp4:*:*:*:*:*:*", "matchCriteriaId": "0B9DE993-8A95-47B5-B192-8985A9C718D0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:omnivise_t3000_application_server:9.2:*:*:*:*:*:*:*", "matchCriteriaId": "EAE3C15D-4E9D-4A7F-930A-938F43D1AAD5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application." }, { "lang": "es", "value": " Se ha identificado una vulnerabilidad en Omnivise T3000 Application Server (todas las versiones). El sistema afectado expone el puerto de una aplicaci\u00f3n interna en la interfaz de la red p\u00fablica, lo que permite a un atacante omitir la autenticaci\u00f3n y acceder directamente a la aplicaci\u00f3n expuesta." } ], "id": "CVE-2024-38879", "lastModified": "2024-09-20T23:26:28.767", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "NONE", "vulnerableSystemConfidentiality": "HIGH", "vulnerableSystemIntegrity": "NONE" }, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2024-08-02T11:16:42.510", "references": [ { "source": "productcert@siemens.com", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-857368.html" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
var-202408-0013
Vulnerability from variot
A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application. Siemens' omnivise t3000 application server Exists in unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Omnivise T3000 is a distributed control system mainly used in fossil fuel and large renewable energy power plants.
Siemens Omnivise T3000 Application Server has an improper input validation vulnerability
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202408-0013", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "omnivise t3000 application server", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "9.2" }, { "model": "omnivise t3000 application server", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "8.2" }, { "model": "omnivise t3000 application server", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "omnivise t3000 application server", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "8.2" }, { "model": "omnivise t3000 application server", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "9.2" }, { "model": "omnivise t3000 application server", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "omnivise t3000 application server", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "omnivise t3000 domain controller", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "omnivise t3000 product data management", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "omnivise t3000 terminal server", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "omnivise t3000 thin client", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "omnivise t3000 whitelisting server", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-35109" }, { "db": "JVNDB", "id": "JVNDB-2024-008693" }, { "db": "NVD", "id": "CVE-2024-38879" } ] }, "cve": "CVE-2024-38879", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2024-35109", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2024-38879", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2024-38879", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2024-38879", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2024-38879", "trust": 1.0, "value": "CRITICAL" }, { "author": "productcert@siemens.com", "id": "CVE-2024-38879", "trust": 1.0, "value": "High" }, { "author": "NVD", "id": "CVE-2024-38879", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2024-35109", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-35109" }, { "db": "JVNDB", "id": "JVNDB-2024-008693" }, { "db": "NVD", "id": "CVE-2024-38879" }, { "db": "NVD", "id": "CVE-2024-38879" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). The affected system exposes the port of an internal application on the public network interface allowing an attacker to circumvent authentication and directly access the exposed application. Siemens\u0027 omnivise t3000 application server Exists in unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Omnivise T3000 is a distributed control system mainly used in fossil fuel and large renewable energy power plants. \n\nSiemens Omnivise T3000 Application Server has an improper input validation vulnerability", "sources": [ { "db": "NVD", "id": "CVE-2024-38879" }, { "db": "JVNDB", "id": "JVNDB-2024-008693" }, { "db": "CNVD", "id": "CNVD-2024-35109" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-38879", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-857368", "trust": 2.4 }, { "db": "JVN", "id": "JVNVU99298639", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2024-008693", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2024-35109", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-35109" }, { "db": "JVNDB", "id": "JVNDB-2024-008693" }, { "db": "NVD", "id": "CVE-2024-38879" } ] }, "id": "VAR-202408-0013", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-35109" } ], "trust": 1.41111108 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-35109" } ] }, "last_update_date": "2024-09-25T20:10:26.412000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens Omnivise T3000 Application Server Improper Input Validation Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/576731" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-35109" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-20", "trust": 1.0 }, { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Inappropriate input confirmation (CWE-20) [ others ]", "trust": 0.8 }, { "problemtype": " Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-008693" }, { "db": "NVD", "id": "CVE-2024-38879" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://cert-portal.siemens.com/productcert/html/ssa-857368.html" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu99298639/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-38879" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-35109" }, { "db": "JVNDB", "id": "JVNDB-2024-008693" }, { "db": "NVD", "id": "CVE-2024-38879" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-35109" }, { "db": "JVNDB", "id": "JVNDB-2024-008693" }, { "db": "NVD", "id": "CVE-2024-38879" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-08-12T00:00:00", "db": "CNVD", "id": "CNVD-2024-35109" }, { "date": "2024-09-24T00:00:00", "db": "JVNDB", "id": "JVNDB-2024-008693" }, { "date": "2024-08-02T11:16:42.510000", "db": "NVD", "id": "CVE-2024-38879" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-08-12T00:00:00", "db": "CNVD", "id": "CNVD-2024-35109" }, { "date": "2024-09-24T02:10:00", "db": "JVNDB", "id": "JVNDB-2024-008693" }, { "date": "2024-09-20T23:26:28.767000", "db": "NVD", "id": "CVE-2024-38879" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens\u0027 \u00a0omnivise\u00a0t3000\u00a0application\u00a0server\u00a0 Vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-008693" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.