cve-2024-29177
Vulnerability from cvelistv5
Published
2024-06-26 02:46
Modified
2024-08-02 01:10
Severity ?
EPSS score ?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | PowerProtect DD |
Version: 7.0 ≤ 7.13 Version: N/A ≤ Version: N/A ≤ Version: 7.8 ≤ 7.13 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-29177", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-06-26T19:05:17.020326Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-26T19:05:23.225Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T01:10:54.086Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PowerProtect DD", "vendor": "Dell", "versions": [ { "lessThanOrEqual": "7.13", "status": "affected", "version": "7.0", "versionType": "semver" }, { "lessThan": "2.7.7", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThan": "5.16.0.0", "status": "affected", "version": "N/A", "versionType": "semver" }, { "lessThanOrEqual": "7.13", "status": "affected", "version": "7.8", "versionType": "semver" } ] } ], "datePublic": "2024-06-24T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report." } ], "value": "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-532", "description": "CWE-532: Insertion of Sensitive Information into Log File", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-26T02:46:55.073Z", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2024-29177", "datePublished": "2024-06-26T02:46:55.073Z", "dateReserved": "2024-03-18T08:44:18.924Z", "dateUpdated": "2024-08-02T01:10:54.086Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-29177\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2024-06-26T03:15:10.767\",\"lastModified\":\"2024-11-21T09:07:43.943\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report.\"},{\"lang\":\"es\",\"value\":\"Dell PowerProtect DD, versiones anteriores a 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contienen una divulgaci\u00f3n de vulnerabilidad de informaci\u00f3n confidencial temporal. Un atacante remoto con privilegios elevados podr\u00eda explotar esta vulnerabilidad, lo que llevar\u00eda a la reutilizaci\u00f3n de la informaci\u00f3n divulgada para obtener acceso no autorizado al informe de la aplicaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":2.7,\"baseSeverity\":\"LOW\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.2,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":2.7,\"baseSeverity\":\"LOW\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.2,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-532\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.7.5.40\",\"matchCriteriaId\":\"C6A0B6C8-491A-46F2-A330-15000DE501BA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.8.0.0\",\"versionEndExcluding\":\"7.10.1.30\",\"matchCriteriaId\":\"28F4339F-F4B0-479A-B300-ADB987171B31\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.11.0.0\",\"versionEndExcluding\":\"7.13.1.0\",\"matchCriteriaId\":\"8EF3066F-F378-4AA6-B50C-B33C22C57492\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T01:10:54.086Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-29177\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-06-26T19:05:17.020326Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-06-26T19:05:20.645Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 2.7, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"LOW\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"PowerProtect DD\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}, {\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"2.7.7\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"5.16.0.0\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"7.8\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2024-06-24T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a disclosure of temporary sensitive information vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the reuse of disclosed information to gain unauthorized access to the application report.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-532\", \"description\": \"CWE-532: Insertion of Sensitive Information into Log File\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2024-06-26T02:46:55.073Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2024-29177\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-02T01:10:54.086Z\", \"dateReserved\": \"2024-03-18T08:44:18.924Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2024-06-26T02:46:55.073Z\", \"assignerShortName\": \"dell\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.