cve-2024-29175
Vulnerability from cvelistv5
Published
2024-06-26 03:03
Modified
2024-08-02 01:10
Summary
Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information.
Impacted products
Vendor Product Version
Dell PowerProtect DD Version: 7.0    7.13
Version: N/A   
Version: N/A   
Version: 7.8    7.13
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:dell:powerprotect_dd:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "powerprotect_dd",
            "vendor": "dell",
            "versions": [
              {
                "lessThanOrEqual": "7.13",
                "status": "affected",
                "version": "7.0",
                "versionType": "semver"
              },
              {
                "lessThan": "2.7.7",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              },
              {
                "lessThan": "5.16.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              },
              {
                "lessThanOrEqual": "7.13",
                "status": "affected",
                "version": "7.8",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29175",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-11T15:11:41.076013Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-11T15:17:48.750Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:10:54.627Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerProtect DD",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.0",
              "versionType": "semver"
            },
            {
              "lessThan": "2.7.7",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "5.16.0.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.13",
              "status": "affected",
              "version": "7.8",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2024-06-24T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information."
            }
          ],
          "value": "Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-26T03:03:06.155Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2024-29175",
    "datePublished": "2024-06-26T03:03:06.155Z",
    "dateReserved": "2024-03-18T08:44:18.923Z",
    "dateUpdated": "2024-08-02T01:10:54.627Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-29175\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2024-06-26T03:15:10.303\",\"lastModified\":\"2024-11-21T09:07:43.653\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information.\"},{\"lang\":\"es\",\"value\":\"Dell PowerProtect Data Domain, versiones anteriores a 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contienen una vulnerabilidad de algoritmo criptogr\u00e1fico d\u00e9bil. Un atacante remoto no autenticado podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda un ataque de intermediario que exponga informaci\u00f3n confidencial de la sesi\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-327\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-327\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.7.5.40\",\"matchCriteriaId\":\"C6A0B6C8-491A-46F2-A330-15000DE501BA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.8.0.0\",\"versionEndExcluding\":\"7.10.1.30\",\"matchCriteriaId\":\"28F4339F-F4B0-479A-B300-ADB987171B31\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.11.0.0\",\"versionEndExcluding\":\"7.13.1.0\",\"matchCriteriaId\":\"8EF3066F-F378-4AA6-B50C-B33C22C57492\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T01:10:54.627Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-29175\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-11T15:11:41.076013Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:dell:powerprotect_dd:*:*:*:*:*:*:*:*\"], \"vendor\": \"dell\", \"product\": \"powerprotect_dd\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}, {\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.7.7\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"5.16.0.0\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"7.8\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}], \"defaultStatus\": \"unaffected\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-11T15:15:13.896Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.9, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"PowerProtect DD\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}, {\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"2.7.7\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"5.16.0.0\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"7.8\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2024-06-24T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell PowerProtect Data Domain, versions prior to 7.13.0.0, LTS 7.7.5.40, LTS 7.10.1.30 contain an weak cryptographic algorithm vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to man-in-the-middle attack that exposes sensitive session information.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-327\", \"description\": \"CWE-327: Use of a Broken or Risky Cryptographic Algorithm\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2024-06-26T03:03:06.155Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-29175\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-02T01:10:54.627Z\", \"dateReserved\": \"2024-03-18T08:44:18.923Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2024-06-26T03:03:06.155Z\", \"assignerShortName\": \"dell\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.