Summary
A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been declared as critical. Affected by this vulnerability is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/theRaz0r/iot-mycve/blob/main/Dlink_DI8003_stackoverflow/Dlink_DI8003_stackoverflow.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.283633 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.283633 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?submit.434931 | Third Party Advisory | |
cna@vuldb.com | https://www.dlink.com/ | Product |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:d-link:di-8003_firmware:16.07.16a1:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "di-8003_firmware", "vendor": "d-link", "versions": [ { "status": "affected", "version": "16.07.16a1" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-11047", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-12T15:44:21.435500Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-12T15:46:48.981Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "DI-8003", "vendor": "D-Link", "versions": [ { "status": "affected", "version": "16.07.16A1" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "theRaz0r (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been declared as critical. Affected by this vulnerability is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "In D-Link DI-8003 16.07.16A1 wurde eine kritische Schwachstelle ausgemacht. Dabei geht es um die Funktion upgrade_filter_asp der Datei /upgrade_filter.asp. Durch das Beeinflussen des Arguments path mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-10T03:31:04.900Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-283633 | D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.283633" }, { "name": "VDB-283633 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.283633" }, { "name": "Submit #434931 | Dlink DI8003 16.07.16A1 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.434931" }, { "tags": [ "exploit" ], "url": "https://github.com/theRaz0r/iot-mycve/blob/main/Dlink_DI8003_stackoverflow/Dlink_DI8003_stackoverflow.md" }, { "tags": [ "product" ], "url": "https://www.dlink.com/" } ], "timeline": [ { "lang": "en", "time": "2024-11-09T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-11-09T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-11-09T09:13:43.000Z", "value": "VulDB entry last update" } ], "title": "D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-11047", "datePublished": "2024-11-10T03:31:04.900Z", "dateReserved": "2024-11-09T08:08:34.041Z", "dateUpdated": "2024-11-12T15:46:48.981Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-11047\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2024-11-10T04:15:15.950\",\"lastModified\":\"2024-11-13T20:56:10.463\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been declared as critical. Affected by this vulnerability is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.\"},{\"lang\":\"es\",\"value\":\"Se ha encontrado una vulnerabilidad en D-Link DI-8003 16.07.16A1. Se ha declarado como cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n upgrade_filter_asp del archivo /upgrade_filter.asp. La manipulaci\u00f3n de la ruta de argumentos provoca un desbordamiento del b\u00fafer basado en la pila. El ataque se puede ejecutar de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"HIGH\",\"vulnerableSystemIntegrity\":\"HIGH\",\"vulnerableSystemAvailability\":\"HIGH\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"},{\"lang\":\"en\",\"value\":\"CWE-121\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dlink:di-8003_firmware:16.07.16a1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"09B22DC9-F8B2-462A-A64C-5881DC1E3FCD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dlink:di-8003:a1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"840B4964-A435-4220-BBCC-08DC344FD7D1\"}]}]}],\"references\":[{\"url\":\"https://github.com/theRaz0r/iot-mycve/blob/main/Dlink_DI8003_stackoverflow/Dlink_DI8003_stackoverflow.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.283633\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\"]},{\"url\":\"https://vuldb.com/?id.283633\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\"]},{\"url\":\"https://vuldb.com/?submit.434931\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.dlink.com/\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Product\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-11047\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-12T15:44:21.435500Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:d-link:di-8003_firmware:16.07.16a1:*:*:*:*:*:*:*\"], \"vendor\": \"d-link\", \"product\": \"di-8003_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"16.07.16a1\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-12T15:46:42.034Z\"}}], \"cna\": {\"title\": \"D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp stack-based overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"theRaz0r (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\"}}], \"affected\": [{\"vendor\": \"D-Link\", \"product\": \"DI-8003\", \"versions\": [{\"status\": \"affected\", \"version\": \"16.07.16A1\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2024-11-09T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2024-11-09T01:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2024-11-09T09:13:43.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.283633\", \"name\": \"VDB-283633 | D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.283633\", \"name\": \"VDB-283633 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.434931\", \"name\": \"Submit #434931 | Dlink DI8003 16.07.16A1 Buffer Overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/theRaz0r/iot-mycve/blob/main/Dlink_DI8003_stackoverflow/Dlink_DI8003_stackoverflow.md\", \"tags\": [\"exploit\"]}, {\"url\": \"https://www.dlink.com/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been declared as critical. Affected by this vulnerability is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.\"}, {\"lang\": \"de\", \"value\": \"In D-Link DI-8003 16.07.16A1 wurde eine kritische Schwachstelle ausgemacht. Dabei geht es um die Funktion upgrade_filter_asp der Datei /upgrade_filter.asp. Durch das Beeinflussen des Arguments path mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \\u00fcber das Netzwerk erfolgen. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"Stack-based Buffer Overflow\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-119\", \"description\": \"Memory Corruption\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2024-11-10T03:31:04.900Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2024-11047\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-12T15:46:48.981Z\", \"dateReserved\": \"2024-11-09T08:08:34.041Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2024-11-10T03:31:04.900Z\", \"assignerShortName\": \"VulDB\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.