CVE-2023-34392 (GCVE-0-2023-34392)

Vulnerability from cvelistv5 – Published: 2023-08-31 15:31 – Updated: 2024-10-01 16:59
VLAI
Title
Missing Authentication for Critical Function
Summary
A Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-01 16:59 UTC
CWE
  • CWE-306 - Missing Authentication for Critical Function
Impacted products
Vendor Product Version CPE status
Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator Affected: 0 , < 4.5.0.20 (custom)
guessed Create a notification for this product.
Date Public
2023-08-31 16:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T16:10:06.984Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-34392",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T16:59:13.785566Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T16:59:22.498Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "SEL-5037 SEL Grid Configurator",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "4.5.0.20",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "datePublic": "2023-08-31T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nA Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\u003c/p\u003e"
            }
          ],
          "value": "\nA Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-180",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-31T15:31:57.140Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Missing Authentication for Critical Function",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-34392",
    "datePublished": "2023-08-31T15:31:57.140Z",
    "dateReserved": "2023-06-02T17:18:29.697Z",
    "dateUpdated": "2024-10-01T16:59:22.498Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2023-34392",
      "date": "2026-09-22",
      "epss": "0.00453",
      "percentile": "0.38682"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:selinc:sel-5037_sel_grid_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8DE1284E-619F-49AC-AE96-0A4ECD76292B",
                  "versionEndExcluding": "4.5.0.20",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "\nA Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
        }
      ],
      "id": "CVE-2023-34392",
      "lastModified": "2024-11-21T08:07:09.853",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 8.2,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.5,
            "impactScore": 6.0,
            "source": "security@selinc.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2023-08-31T16:15:10.123",
      "references": [
        {
          "source": "security@selinc.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "source": "security@selinc.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.nozominetworks.com/blog/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "sourceIdentifier": "security@selinc.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-306"
            }
          ],
          "source": "security@selinc.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-306"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Windows"
                ],
                "product": "SEL-5037 SEL Grid Configurator",
                "vendor": "Schweitzer Engineering Laboratories",
                "versions": [
                  {
                    "lessThan": "4.5.0.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "security@selinc.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:selinc:sel-5037_sel_grid_configurator:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8DE1284E-619F-49AC-AE96-0A4ECD76292B",
                    "versionEndExcluding": "4.5.0.20",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "\nA Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
          },
          {
            "lang": "es",
            "value": "Una vulnerabilidad de ausencia de autenticaci\u00f3n para funci\u00f3n cr\u00edtica en el Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator podr\u00eda permitir a un atacante ejecutar comandos arbitrarios en dispositivos gestionados por un operador de dispositivo autorizado.\n\nConsulte el Manual de Instrucciones Ap\u00e9ndice A y Ap\u00e9ndice E con fecha 20230615 para m\u00e1s detalles.\n\nEste problema afecta a SEL-5037 SEL Grid Configurator: antes de 4.5.0.20."
          }
        ],
        "id": "CVE-2023-34392",
        "lastModified": "2026-06-17T06:03:32.590",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.5,
              "impactScore": 6.0,
              "source": "security@selinc.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2023-34392",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T16:59:13.785566Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2023-08-31T16:15:10.123",
        "references": [
          {
            "source": "security@selinc.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "source": "security@selinc.com",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "sourceIdentifier": "security@selinc.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-306"
              }
            ],
            "source": "security@selinc.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-306"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T23:28:56+00:00",
      "cve": "CVE-2023-34392",
      "id": "CVE-2023-34392",
      "initial_release_date": "2023-08-31T16:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Missing Authentication for Critical Function",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2023/cve-2023-34392.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:10:06.984Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-34392",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-01T16:59:13.785566Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-01T16:59:19.060Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5037 SEL Grid Configurator",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "4.5.0.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nA Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\u003c/p\u003e"
                }
              ],
              "value": "\nA Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-180",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:31:57.140Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Missing Authentication for Critical Function",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-34392",
        "datePublished": "2023-08-31T15:31:57.140Z",
        "dateReserved": "2023-06-02T17:18:29.697Z",
        "dateUpdated": "2024-10-01T16:59:22.498Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…