GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2022-32514 (GCVE-0-2022-32514)

Vulnerability from cvelistv5 – Published: 2023-01-30 00:00 – Updated: 2025-02-05 20:18
VLAI
Summary
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-05 19:57 UTC
CWE
  • CWE-287 - Improper Authentication
Date Public
2022-06-14 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:46:43.528Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-32514",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-05T19:57:05.377109Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:18:27.254Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "C-Bus Network Automation Controller, LSS5500NAC",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "V1.10.0",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Wiser for C-Bus Automation Controller, LSS5500SHAC",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "V1.10.0",
              "status": "affected",
              "version": "All ",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Clipsal C-Bus Network Automation Controller, 5500NAC",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "V1.10.0",
              "status": "affected",
              "version": "All ",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Clipsal Wiser for C-Bus Automation Controller, 5500SHAC",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "V1.10.0",
              "status": "affected",
              "version": "All ",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "SpaceLogic C-Bus Network Automation Controller, 5500NAC2",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "V1.10.0",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "SpaceLogic C-Bus Application Controller, 5500AC2",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "V1.10.0",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-06-14T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-30T00:00:00.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2022-32514",
    "datePublished": "2023-01-30T00:00:00.000Z",
    "dateReserved": "2022-06-07T00:00:00.000Z",
    "dateUpdated": "2025-02-05T20:18:27.254Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-32514",
      "date": "2026-09-19",
      "epss": "0.00788",
      "percentile": "0.54651"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:5500ac2_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7628A67-6DD8-47B7-9112-C130AF0DA9BD",
                  "versionEndExcluding": "1.11.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:5500ac2:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1E9DDB3B-9342-4729-9EE7-703426B9670C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:5500nac_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FD075DCC-90DA-45A1-ADC9-ADD7D984B2F9",
                  "versionEndExcluding": "1.11.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:5500nac:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CDCFD29E-C66E-41F4-B578-095C08799994",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:5500nac2_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7B729EF-ECCC-41E1-BF89-E2EAB013144F",
                  "versionEndExcluding": "1.11.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:5500nac2:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BF623989-1FC8-44D5-9B4B-42CDCF31B824",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:5500shac_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D414788B-B8B5-41A0-8946-433D7A308F4D",
                  "versionEndExcluding": "1.11.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:5500shac:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "91E6F8C8-BC42-4EA0-B36F-96CCE73B080F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:lss5500nac_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B1F807FA-B4A7-4917-80D9-1D9D3AA96516",
                  "versionEndExcluding": "1.11.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:lss5500nac:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0844B578-39C4-413F-9CE9-5DA12A02CE8A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:lss5500shac_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3B231797-8810-4C77-BD0B-0C8A6FBD8C2B",
                  "versionEndExcluding": "1.11.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:lss5500shac:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0B48CA89-FC26-45D4-91C3-F2BD74DC3FBC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)"
        },
        {
          "lang": "es",
          "value": "Existe una vulnerabilidad CWE-287: autenticaci\u00f3n incorrecta que podr\u00eda permitir a un atacante obtener control del dispositivo al iniciar sesi\u00f3n en una p\u00e1gina web. Productos afectados: Controlador de automatizaci\u00f3n de red C-Bus - LSS5500NAC (versiones anteriores a V1.10.0), Wiser para controlador de automatizaci\u00f3n de red C-Bus - LSS5500SHAC (versiones anteriores a V1.10.0), Controlador de automatizaci\u00f3n de red Clipsal C-Bus - 5500NAC (versiones anteriores a V1.10.0), Clipsal Wiser para controlador de automatizaci\u00f3n C-Bus - 5500SHAC (versiones anteriores a V1.10.0), controlador de automatizaci\u00f3n de red SpaceLogic C-Bus - 5500NAC2 (versiones anteriores a V1.10.0), controlador de aplicaciones SpaceLogic C-Bus - 5500AC2 (Versiones anteriores a V1.10.0)"
        }
      ],
      "id": "CVE-2022-32514",
      "lastModified": "2024-11-21T07:06:32.053",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "cybersecurity@se.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2023-01-30T23:15:10.007",
      "references": [
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
        }
      ],
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-287"
            }
          ],
          "source": "cybersecurity@se.com",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "C-Bus Network Automation Controller, LSS5500NAC",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "lessThan": "V1.10.0",
                    "status": "affected",
                    "version": "All",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "product": "Wiser for C-Bus Automation Controller, LSS5500SHAC",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "lessThan": "V1.10.0",
                    "status": "affected",
                    "version": "All ",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "product": "Clipsal C-Bus Network Automation Controller, 5500NAC",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "lessThan": "V1.10.0",
                    "status": "affected",
                    "version": "All ",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "product": "Clipsal Wiser for C-Bus Automation Controller, 5500SHAC",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "lessThan": "V1.10.0",
                    "status": "affected",
                    "version": "All ",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "product": "SpaceLogic C-Bus Network Automation Controller, 5500NAC2",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "lessThan": "V1.10.0",
                    "status": "affected",
                    "version": "All",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "product": "SpaceLogic C-Bus Application Controller, 5500AC2",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "lessThan": "V1.10.0",
                    "status": "affected",
                    "version": "All",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "cybersecurity@se.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:schneider-electric:5500ac2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E7628A67-6DD8-47B7-9112-C130AF0DA9BD",
                    "versionEndExcluding": "1.11.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:schneider-electric:5500ac2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1E9DDB3B-9342-4729-9EE7-703426B9670C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:schneider-electric:5500nac_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FD075DCC-90DA-45A1-ADC9-ADD7D984B2F9",
                    "versionEndExcluding": "1.11.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:schneider-electric:5500nac:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CDCFD29E-C66E-41F4-B578-095C08799994",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:schneider-electric:5500nac2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E7B729EF-ECCC-41E1-BF89-E2EAB013144F",
                    "versionEndExcluding": "1.11.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:schneider-electric:5500nac2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BF623989-1FC8-44D5-9B4B-42CDCF31B824",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:schneider-electric:5500shac_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D414788B-B8B5-41A0-8946-433D7A308F4D",
                    "versionEndExcluding": "1.11.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:schneider-electric:5500shac:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "91E6F8C8-BC42-4EA0-B36F-96CCE73B080F",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:schneider-electric:lss5500nac_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B1F807FA-B4A7-4917-80D9-1D9D3AA96516",
                    "versionEndExcluding": "1.11.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:schneider-electric:lss5500nac:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0844B578-39C4-413F-9CE9-5DA12A02CE8A",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:schneider-electric:lss5500shac_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3B231797-8810-4C77-BD0B-0C8A6FBD8C2B",
                    "versionEndExcluding": "1.11.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:schneider-electric:lss5500shac:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0B48CA89-FC26-45D4-91C3-F2BD74DC3FBC",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)"
          },
          {
            "lang": "es",
            "value": "Existe una vulnerabilidad CWE-287: autenticaci\u00f3n incorrecta que podr\u00eda permitir a un atacante obtener control del dispositivo al iniciar sesi\u00f3n en una p\u00e1gina web. Productos afectados: Controlador de automatizaci\u00f3n de red C-Bus - LSS5500NAC (versiones anteriores a V1.10.0), Wiser para controlador de automatizaci\u00f3n de red C-Bus - LSS5500SHAC (versiones anteriores a V1.10.0), Controlador de automatizaci\u00f3n de red Clipsal C-Bus - 5500NAC (versiones anteriores a V1.10.0), Clipsal Wiser para controlador de automatizaci\u00f3n C-Bus - 5500SHAC (versiones anteriores a V1.10.0), controlador de automatizaci\u00f3n de red SpaceLogic C-Bus - 5500NAC2 (versiones anteriores a V1.10.0), controlador de aplicaciones SpaceLogic C-Bus - 5500AC2 (Versiones anteriores a V1.10.0)"
          }
        ],
        "id": "CVE-2022-32514",
        "lastModified": "2026-06-17T04:47:27.260",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "cybersecurity@se.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2022-32514",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-05T19:57:05.377109Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2023-01-30T23:15:10.007",
        "references": [
          {
            "source": "cybersecurity@se.com",
            "tags": [
              "Patch",
              "Vendor Advisory"
            ],
            "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Patch",
              "Vendor Advisory"
            ],
            "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
          }
        ],
        "sourceIdentifier": "cybersecurity@se.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-287"
              }
            ],
            "source": "cybersecurity@se.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-29T03:09:41+00:00",
      "cve": "CVE-2022-32514",
      "id": "CVE-2022-32514",
      "initial_release_date": "2022-06-14T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2022-32514",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-32514.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:46:43.528Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-32514",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:57:05.377109Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:15:52.678Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "C-Bus Network Automation Controller, LSS5500NAC",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V1.10.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Wiser for C-Bus Automation Controller, LSS5500SHAC",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V1.10.0",
                  "status": "affected",
                  "version": "All ",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Clipsal C-Bus Network Automation Controller, 5500NAC",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V1.10.0",
                  "status": "affected",
                  "version": "All ",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Clipsal Wiser for C-Bus Automation Controller, 5500SHAC",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V1.10.0",
                  "status": "affected",
                  "version": "All ",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "SpaceLogic C-Bus Network Automation Controller, 5500NAC2",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V1.10.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "SpaceLogic C-Bus Application Controller, 5500AC2",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "V1.10.0",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-06-14T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-01-30T00:00:00.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2022-32514",
        "datePublished": "2023-01-30T00:00:00.000Z",
        "dateReserved": "2022-06-07T00:00:00.000Z",
        "dateUpdated": "2025-02-05T20:18:27.254Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…