cve-2022-29091
Vulnerability from cvelistv5
Published
2022-05-26 15:20
Modified
2024-09-16 22:40
Severity ?
EPSS score ?
Summary
Dell Unity, Dell UnityVSA, and Dell UnityXT versions prior to 5.2.0.0.5.173 contain a Reflected Cross-Site Scripting Vulnerability in Unisphere GUI. An Unauthenticated Remote Attacker could potentially exploit this vulnerability, leading to the execution of malicious HTML or JavaScript code in a victim user's web browser in the context of the vulnerable web application. Exploitation may lead to information disclosure, session theft, or client-side request forgery.
References
▼ | URL | Tags | |
---|---|---|---|
security_alert@emc.com | https://www.dell.com/support/kbdoc/000199446 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dell.com/support/kbdoc/000199446 | Vendor Advisory |
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T06:10:59.051Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://www.dell.com/support/kbdoc/000199446", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "Unity", vendor: "Dell", versions: [ { lessThan: "5.2.0.0.5.173", status: "affected", version: "unspecified", versionType: "custom", }, ], }, ], datePublic: "2022-05-11T00:00:00", descriptions: [ { lang: "en", value: "Dell Unity, Dell UnityVSA, and Dell UnityXT versions prior to 5.2.0.0.5.173 contain a Reflected Cross-Site Scripting Vulnerability in Unisphere GUI. An Unauthenticated Remote Attacker could potentially exploit this vulnerability, leading to the execution of malicious HTML or JavaScript code in a victim user's web browser in the context of the vulnerable web application. Exploitation may lead to information disclosure, session theft, or client-side request forgery.", }, ], metrics: [ { cvssV3_1: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "LOW", baseScore: 5.3, baseSeverity: "MEDIUM", confidentialityImpact: "NONE", integrityImpact: "NONE", privilegesRequired: "NONE", scope: "UNCHANGED", userInteraction: "NONE", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", version: "3.1", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-79", description: "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2022-05-26T15:20:27", orgId: "c550e75a-17ff-4988-97f0-544cde3820fe", shortName: "dell", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://www.dell.com/support/kbdoc/000199446", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "secure@dell.com", DATE_PUBLIC: "2022-05-11", ID: "CVE-2022-29091", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "Unity", version: { version_data: [ { version_affected: "<", version_value: "5.2.0.0.5.173", }, ], }, }, ], }, vendor_name: "Dell", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "Dell Unity, Dell UnityVSA, and Dell UnityXT versions prior to 5.2.0.0.5.173 contain a Reflected Cross-Site Scripting Vulnerability in Unisphere GUI. An Unauthenticated Remote Attacker could potentially exploit this vulnerability, leading to the execution of malicious HTML or JavaScript code in a victim user's web browser in the context of the vulnerable web application. Exploitation may lead to information disclosure, session theft, or client-side request forgery.", }, ], }, impact: { cvss: { baseScore: 5.3, baseSeverity: "Medium", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", version: "3.1", }, }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')", }, ], }, ], }, references: { reference_data: [ { name: "https://www.dell.com/support/kbdoc/000199446", refsource: "MISC", url: "https://www.dell.com/support/kbdoc/000199446", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "c550e75a-17ff-4988-97f0-544cde3820fe", assignerShortName: "dell", cveId: "CVE-2022-29091", datePublished: "2022-05-26T15:20:27.703351Z", dateReserved: "2022-04-12T00:00:00", dateUpdated: "2024-09-16T22:40:13.543Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { nvd: "{\"cve\":{\"id\":\"CVE-2022-29091\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2022-05-26T16:15:08.383\",\"lastModified\":\"2024-11-21T06:58:27.990\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell Unity, Dell UnityVSA, and Dell UnityXT versions prior to 5.2.0.0.5.173 contain a Reflected Cross-Site Scripting Vulnerability in Unisphere GUI. An Unauthenticated Remote Attacker could potentially exploit this vulnerability, leading to the execution of malicious HTML or JavaScript code in a victim user's web browser in the context of the vulnerable web application. Exploitation may lead to information disclosure, session theft, or client-side request forgery.\"},{\"lang\":\"es\",\"value\":\"Dell Unity, Dell UnityVSA y Dell UnityXT versiones anteriores a 5.2.0.0.5.173, contienen una vulnerabilidad de tipo Cross-Site Scripting reflejado en la GUI de Unisphere. Un atacante remoto no autenticado podría explotar esta vulnerabilidad, conllevando a una ejecución de código HTML o JavaScript malicioso en el navegador web de un usuario víctima en el contexto de la aplicación web vulnerable. La explotación puede conllevar a una divulgación de información, el robo de sesiones o la falsificación de peticiones del lado del cliente\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:unity_operating_environment:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.0.0.5.173\",\"matchCriteriaId\":\"4855E724-3CDB-403C-990A-BC40D11F164C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:unity_xt_operating_environment:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.0.0.5.173\",\"matchCriteriaId\":\"0F60B8C6-8F5B-4E0C-BAFD-764F24200CDA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:unityvsa_operating_environment:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.0.0.5.173\",\"matchCriteriaId\":\"FA1CEA94-0334-4783-BB4B-8863BFEFB7B6\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/000199446\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/000199446\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.