cve-2021-23285
Vulnerability from cvelistv5
Published
2022-04-18 16:20
Modified
2024-09-16 22:41
Severity ?
EPSS score ?
Summary
Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to reflected Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Eaton | Intelligent Power Manager Infrastructure (IPM Infrastructure) |
Version: all < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T19:05:55.463Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-%28IPM%29-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf." } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Intelligent Power Manager Infrastructure (IPM Infrastructure)", "vendor": "Eaton", "versions": [ { "lessThanOrEqual": "1.5.0plus205", "status": "affected", "version": "all", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Eaton thanks the ICS-Cert organization and individuals for their coordinated support on the security vulnerability: CVE-2021-23285 \u2013 Micheal Heinzl via ICS-Cert" } ], "datePublic": "2022-04-01T00:00:00", "descriptions": [ { "lang": "en", "value": "Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to reflected Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 3.1, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-18T16:20:31", "orgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759", "shortName": "Eaton" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-%28IPM%29-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf." } ], "solutions": [ { "lang": "en", "value": "The product has reached its End Of Life, the notification has been posted at: Lifecycle Notification: \nThe transition to IPM Monitor Edition is in progress. Refer the Product page for further details." } ], "source": { "discovery": "EXTERNAL" }, "title": "Security issues in Eaton Intelligent Power Manager Infrastructure", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "CybersecurityCOE@eaton.com", "DATE_PUBLIC": "2022-04-01T10:56:00.000Z", "ID": "CVE-2021-23285", "STATE": "PUBLIC", "TITLE": "Security issues in Eaton Intelligent Power Manager Infrastructure" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Intelligent Power Manager Infrastructure (IPM Infrastructure)", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "all", "version_value": "1.5.0plus205" } ] } } ] }, "vendor_name": "Eaton" } ] } }, "credit": [ { "lang": "eng", "value": "Eaton thanks the ICS-Cert organization and individuals for their coordinated support on the security vulnerability: CVE-2021-23285 \u2013 Micheal Heinzl via ICS-Cert" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to reflected Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 3.1, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-(IPM)-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf", "refsource": "MISC", "url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-(IPM)-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf" }, { "name": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf.", "refsource": "MISC", "url": "https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf." } ] }, "solution": [ { "lang": "en", "value": "The product has reached its End Of Life, the notification has been posted at: Lifecycle Notification: \nThe transition to IPM Monitor Edition is in progress. Refer the Product page for further details." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "63703b7d-23e2-41ef-94b3-a3c6333f7759", "assignerShortName": "Eaton", "cveId": "CVE-2021-23285", "datePublished": "2022-04-18T16:20:31.667003Z", "dateReserved": "2021-01-08T00:00:00", "dateUpdated": "2024-09-16T22:41:39.422Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-23285\",\"sourceIdentifier\":\"CybersecurityCOE@eaton.com\",\"published\":\"2022-04-18T17:15:14.467\",\"lastModified\":\"2024-11-21T05:51:30.023\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to reflected Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions.\"},{\"lang\":\"es\",\"value\":\"Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) versi\u00f3n 1.5.0plus205 y todas las versiones anteriores, son susceptibles a una vulnerabilidad de tipo Cross-Site Scripting Reflejado. Este problema afecta: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) todas las versiones 1.5.0plus205 y versiones anteriores\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"CybersecurityCOE@eaton.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:N\",\"baseScore\":3.1,\"baseSeverity\":\"LOW\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.5,\"impactScore\":2.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.7,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"CybersecurityCOE@eaton.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:eaton:intelligent_power_manager:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.5.0plus205\",\"matchCriteriaId\":\"DB64FBE0-11BE-4FA0-B916-4DBA051F952B\"}]}]}],\"references\":[{\"url\":\"https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-%28IPM%29-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf\",\"source\":\"CybersecurityCOE@eaton.com\"},{\"url\":\"https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf.\",\"source\":\"CybersecurityCOE@eaton.com\",\"tags\":[\"Broken Link\"]},{\"url\":\"https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/Eaton-Intelligent-Power-Manager-%28IPM%29-Infrastructure-Vulnerability-Advisory_1001c_V1.0.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-management-software-connectivity/eaton-intelligent-power-manager/software/ipm-understand-edition-emea/eaton-ipminfra-eolmemo-en-us.pdf.\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.