CVE-2020-6996 (GCVE-0-2020-6996)
Vulnerability from cvelistv5 – Published: 2020-04-15 18:46 – Updated: 2024-08-04 09:18- CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01 |
Affected:
Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:18:02.666Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "STACK-BASED BUFFER OVERFLOW CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-15T18:46:30",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-6996",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01",
"version": {
"version_data": [
{
"version_value": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "STACK-BASED BUFFER OVERFLOW CWE-121"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-6996",
"datePublished": "2020-04-15T18:46:30",
"dateReserved": "2020-01-14T00:00:00",
"dateUpdated": "2024-08-04T09:18:02.666Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:trianglemicroworks:dnp3_source_code_library:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"3.16.00\", \"versionEndIncluding\": \"3.25.01\", \"matchCriteriaId\": \"6F97C26A-1C2B-4616-9DB1-109946BB64FF\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.\"}, {\"lang\": \"es\", \"value\": \"Librer\\u00edas de Triangle MicroWorks DNP3 Outstation Los componentes del Protocolo .NET Outstation DNP3 y las bibliotecas de c\\u00f3digo fuente ANSI C de DNP3 Outstation se ven afectadas: 3.16.00 a 3.25.01. Un mensaje especialmente dise\\u00f1ado puede causar un desbordamiento del b\\u00fafer basado en la pila. No se requiere autenticaci\\u00f3n para explotar esta vulnerabilidad.\"}]",
"id": "CVE-2020-6996",
"lastModified": "2024-11-21T05:36:27.533",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-04-15T19:15:13.927",
"references": "[{\"url\": \"https://www.us-cert.gov/ics/advisories/icsa-20-105-02\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.us-cert.gov/ics/advisories/icsa-20-105-02\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-121\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-6996\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-04-15T19:15:13.927\",\"lastModified\":\"2024-11-21T05:36:27.533\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.\"},{\"lang\":\"es\",\"value\":\"Librer\u00edas de Triangle MicroWorks DNP3 Outstation Los componentes del Protocolo .NET Outstation DNP3 y las bibliotecas de c\u00f3digo fuente ANSI C de DNP3 Outstation se ven afectadas: 3.16.00 a 3.25.01. Un mensaje especialmente dise\u00f1ado puede causar un desbordamiento del b\u00fafer basado en la pila. No se requiere autenticaci\u00f3n para explotar esta vulnerabilidad.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trianglemicroworks:dnp3_source_code_library:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.16.00\",\"versionEndIncluding\":\"3.25.01\",\"matchCriteriaId\":\"6F97C26A-1C2B-4616-9DB1-109946BB64FF\"}]}]}],\"references\":[{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-105-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-105-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
CERTFR-2022-AVI-1093
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | Modicon M580 CPU Safety (BMEP58*S et BMEH58*S) toutes versions | ||
| N/A | N/A | APC Easy UPS Online Monitoring versions antérieures à 2.5-GA-01-22320 | ||
| N/A | N/A | EcoStruxure Power Commission versions antérieures à 2.26 | ||
| N/A | N/A | SAITEL DR RTU Baseline 11.06.x antérieures à 1.06.15 |
| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Modicon M580 CPU Safety (BMEP58*S et BMEH58*S) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "APC Easy UPS Online Monitoring versions ant\u00e9rieures \u00e0 2.5-GA-01-22320",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure Power Commission versions ant\u00e9rieures \u00e0 2.26",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "SAITEL DR RTU Baseline 11.06.x ant\u00e9rieures \u00e0 1.06.15",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2019-6846",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6846"
},
{
"name": "CVE-2022-42971",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42971"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2021-22791",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22791"
},
{
"name": "CVE-2022-42973",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42973"
},
{
"name": "CVE-2019-6841",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6841"
},
{
"name": "CVE-2021-22779",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22779"
},
{
"name": "CVE-2021-22790",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22790"
},
{
"name": "CVE-2022-37301",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37301"
},
{
"name": "CVE-2018-7241",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7241"
},
{
"name": "CVE-2021-22786",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22786"
},
{
"name": "CVE-2018-7242",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7242"
},
{
"name": "CVE-2019-6844",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6844"
},
{
"name": "CVE-2019-6842",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6842"
},
{
"name": "CVE-2020-6996",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-6996"
},
{
"name": "CVE-2022-37300",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37300"
},
{
"name": "CVE-2021-22789",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22789"
},
{
"name": "CVE-2019-6847",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6847"
},
{
"name": "CVE-2021-22792",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22792"
},
{
"name": "CVE-2022-42970",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42970"
},
{
"name": "CVE-2019-6843",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6843"
},
{
"name": "CVE-2018-7240",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7240"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2022-4062",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4062"
},
{
"name": "CVE-2022-42972",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42972"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-1093",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-12-13T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider du 13 d\u00e9cembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01-APC_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
]
}
CERTFR-2022-AVI-436
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
- PowerLogic ION Setup versions antérieures à 3.2.22096.01
- Saitel DP RTU microgiciel versions Baseline_09.00.00 à Baseline_11.06.23 antérieures à BaseLine_11.06.24
- APC Smart-UPS SRC Series ID=1004: UPS versions 14.9 et antérieures
- APC Smart-UPS SRC Series ID=1006: UPS versions 14.9 et antérieures
- APC Smart-UPS SRC Series ID=1011: UPS versions 14.9 et antérieures
- APC Smart-UPS SRC Series ID=1033: UPS versions 00.3 et antérieures
- APC Smart-UPS XU Series SRC Series ID=1017: UPS versions 02.6 et antérieures
- SmartConnect séries SMTL, SCL, et SMX version du microgiciel antérieure à 15.0
- HMISCU Vijeo Designer versions antérieures à 6.2 SP12
- Easergy MiCOM P30 range modèles C434, P132, P139, P433, P435, P437, P532, P631, P632, P633, P634 et Px36/8 versions 660 à 674
- APC Rack Power Distribution Units (PDU) utilisant NMC2 AOS versions antérieures à 7.0.6
- APC Rack Power Distribution Units (PDU) utilisant NMC3 AOS versions antérieures à 1.2.0.2
- APC 3-Phase Power Distribution Products utilisant NMC2 AOS versions antérieures à 7.0.4
- Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P) versions antérieures à 7.0.4
- Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) versions antérieures à 7.0.4
- Network Management Card 2 for Modular 150/175kVA PDU (XRDP) versions antérieures à 7.0.4
- Network Management Card 2 for 400 and 500 kVA (PMM) versions antérieures à 7.0.4
- Network Management Card 2 for Modular PDU (XRDP2G) versions antérieures à 7.0.4
- Rack Automatic Transfer Switches (ATS) utilisant NMC2 AOS versions antérieures à 7.0.4
- Network Management Card 2 (NMC2) Cooling Products utilisant NMC2 AOS versions antérieures à 7.0.4
- Environmental Monitoring Unit with embedded NMC2 (NB250) utilisant NMC2 AOS versions antérieures à 7.0.4
- Network Management Card 2 (NMC2) versions antérieures à 7.0.4
- EcoStruxure Micro Data Center utilisant NMC2 AOS versions antérieures à 7.0.4
Les produits suivants ne sont plus supportés par l'éditeur :
- Wiser Smart EER21000 et EER21001 versions antérieures à 4.5
Les produits suivants ne bénéficient pas encore de correctif pour les vulnérabilités CVE-2022-22805, CVE-2022-22806 et CVE-2022-0715 :
- Smart-UPS séries SMT, SMC, SCL, SMX, SRT, SRC, XU, et SRTL
| Vendor | Product | Description |
|---|
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [],
"affected_systems_content": "\u003cul\u003e \u003cli\u003ePowerLogic ION Setup versions ant\u00e9rieures \u00e0 3.2.22096.01\u003c/li\u003e \u003cli\u003eSaitel DP RTU microgiciel versions Baseline_09.00.00 \u00e0 Baseline_11.06.23 ant\u00e9rieures \u00e0 BaseLine_11.06.24\u003c/li\u003e \u003cli\u003eAPC Smart-UPS SRC Series ID=1004: UPS versions 14.9 et ant\u00e9rieures\u003c/li\u003e \u003cli\u003eAPC Smart-UPS SRC Series ID=1006: UPS versions 14.9 et ant\u00e9rieures\u003c/li\u003e \u003cli\u003eAPC Smart-UPS SRC Series ID=1011: UPS versions 14.9 et ant\u00e9rieures\u003c/li\u003e \u003cli\u003eAPC Smart-UPS SRC Series ID=1033: UPS versions 00.3 et ant\u00e9rieures\u003c/li\u003e \u003cli\u003eAPC Smart-UPS XU Series SRC Series ID=1017: UPS versions 02.6 et ant\u00e9rieures\u003c/li\u003e \u003cli\u003eSmartConnect s\u00e9ries SMTL, SCL, et SMX version du microgiciel ant\u00e9rieure \u00e0 15.0\u003c/li\u003e \u003cli\u003eHMISCU Vijeo Designer versions ant\u00e9rieures \u00e0 6.2 SP12\u003c/li\u003e \u003cli\u003eEasergy MiCOM P30 range mod\u00e8les C434, P132, P139, P433, P435, P437, P532, P631, P632, P633, P634 et Px36/8 versions 660 \u00e0 674\u003c/li\u003e \u003cli\u003eAPC Rack Power Distribution Units (PDU) utilisant NMC2 AOS versions ant\u00e9rieures \u00e0 7.0.6\u003c/li\u003e \u003cli\u003eAPC Rack Power Distribution Units (PDU) utilisant NMC3 AOS versions ant\u00e9rieures \u00e0 1.2.0.2\u003c/li\u003e \u003cli\u003eAPC 3-Phase Power Distribution Products utilisant NMC2 AOS versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P) versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 for Modular 150/175kVA PDU (XRDP) versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 for 400 and 500 kVA (PMM) versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 for Modular PDU (XRDP2G) versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eRack Automatic Transfer Switches (ATS) utilisant NMC2 AOS versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 (NMC2) Cooling Products utilisant NMC2 AOS versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eEnvironmental Monitoring Unit with embedded NMC2 (NB250) utilisant NMC2 AOS versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 (NMC2) versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eEcoStruxure Micro Data Center utilisant NMC2 AOS versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eLes produits suivants ne sont plus support\u00e9s par l\u0027\u00e9diteur :\u003c/p\u003e \u003cul\u003e \u003cli\u003eWiser Smart EER21000 et EER21001 versions ant\u00e9rieures \u00e0 4.5\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eLes produits suivants ne b\u00e9n\u00e9ficient pas encore de correctif pour les vuln\u00e9rabilit\u00e9s CVE-2022-22805, CVE-2022-22806 et CVE-2022-0715 :\u003c/p\u003e \u003cul\u003e \u003cli\u003eSmart-UPS s\u00e9ries SMT, SMC, SCL, SMX, SRT, SRC, XU, et SRTL\u003c/li\u003e \u003c/ul\u003e ",
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-30236",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30236"
},
{
"name": "CVE-2021-22811",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22811"
},
{
"name": "CVE-2021-22813",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22813"
},
{
"name": "CVE-2022-30233",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30233"
},
{
"name": "CVE-2022-30238",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30238"
},
{
"name": "CVE-2022-6996",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-6996"
},
{
"name": "CVE-2021-22810",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22810"
},
{
"name": "CVE-2021-22815",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22815"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2022-30234",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30234"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2021-22812",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22812"
},
{
"name": "CVE-2022-30232",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30232"
},
{
"name": "CVE-2020-6996",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-6996"
},
{
"name": "CVE-2022-30235",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30235"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2021-22814",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22814"
},
{
"name": "CVE-2022-30237",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30237"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-436",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-05-10T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour des liens",
"revision_date": "2022-08-22T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Elles permettent \u00e0 un attaquant de provoquer une\nex\u00e9cution de code arbitraire \u00e0 distance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-130-01 du 10 mai 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-130-01_PowerLogic_ION_Setup_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-130-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-130-02 du 10 mai 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-130-02_Saitel_DP_RTU_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-130-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 10 mai 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_Badalloc_Vulnerabilities_Security_Notification_V7.0.pdf\u0026p_Doc_Ref=SEVD-2021-313-05"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-130-03 du 10 mai 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-130-03_WiserSmart_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-130-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-03 du 10 mai 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-03_APC_NMC_Security_Notification_V2.0.pdf\u0026p_Doc_Ref=SEVD-2021-313-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 10 mai 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-02_APC-Smart-UPS_Security_Notification_V6.0.pdf"
}
]
}
CERTFR-2022-AVI-1093
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | Modicon M580 CPU Safety (BMEP58*S et BMEH58*S) toutes versions | ||
| N/A | N/A | APC Easy UPS Online Monitoring versions antérieures à 2.5-GA-01-22320 | ||
| N/A | N/A | EcoStruxure Power Commission versions antérieures à 2.26 | ||
| N/A | N/A | SAITEL DR RTU Baseline 11.06.x antérieures à 1.06.15 |
| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Modicon M580 CPU Safety (BMEP58*S et BMEH58*S) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "APC Easy UPS Online Monitoring versions ant\u00e9rieures \u00e0 2.5-GA-01-22320",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure Power Commission versions ant\u00e9rieures \u00e0 2.26",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "SAITEL DR RTU Baseline 11.06.x ant\u00e9rieures \u00e0 1.06.15",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2019-6846",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6846"
},
{
"name": "CVE-2022-42971",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42971"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2021-22791",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22791"
},
{
"name": "CVE-2022-42973",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42973"
},
{
"name": "CVE-2019-6841",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6841"
},
{
"name": "CVE-2021-22779",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22779"
},
{
"name": "CVE-2021-22790",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22790"
},
{
"name": "CVE-2022-37301",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37301"
},
{
"name": "CVE-2018-7241",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7241"
},
{
"name": "CVE-2021-22786",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22786"
},
{
"name": "CVE-2018-7242",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7242"
},
{
"name": "CVE-2019-6844",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6844"
},
{
"name": "CVE-2019-6842",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6842"
},
{
"name": "CVE-2020-6996",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-6996"
},
{
"name": "CVE-2022-37300",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37300"
},
{
"name": "CVE-2021-22789",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22789"
},
{
"name": "CVE-2019-6847",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6847"
},
{
"name": "CVE-2021-22792",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22792"
},
{
"name": "CVE-2022-42970",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42970"
},
{
"name": "CVE-2019-6843",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6843"
},
{
"name": "CVE-2018-7240",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7240"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2022-4062",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4062"
},
{
"name": "CVE-2022-42972",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42972"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-1093",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-12-13T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider du 13 d\u00e9cembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01-APC_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
]
}
CERTFR-2022-AVI-436
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
- PowerLogic ION Setup versions antérieures à 3.2.22096.01
- Saitel DP RTU microgiciel versions Baseline_09.00.00 à Baseline_11.06.23 antérieures à BaseLine_11.06.24
- APC Smart-UPS SRC Series ID=1004: UPS versions 14.9 et antérieures
- APC Smart-UPS SRC Series ID=1006: UPS versions 14.9 et antérieures
- APC Smart-UPS SRC Series ID=1011: UPS versions 14.9 et antérieures
- APC Smart-UPS SRC Series ID=1033: UPS versions 00.3 et antérieures
- APC Smart-UPS XU Series SRC Series ID=1017: UPS versions 02.6 et antérieures
- SmartConnect séries SMTL, SCL, et SMX version du microgiciel antérieure à 15.0
- HMISCU Vijeo Designer versions antérieures à 6.2 SP12
- Easergy MiCOM P30 range modèles C434, P132, P139, P433, P435, P437, P532, P631, P632, P633, P634 et Px36/8 versions 660 à 674
- APC Rack Power Distribution Units (PDU) utilisant NMC2 AOS versions antérieures à 7.0.6
- APC Rack Power Distribution Units (PDU) utilisant NMC3 AOS versions antérieures à 1.2.0.2
- APC 3-Phase Power Distribution Products utilisant NMC2 AOS versions antérieures à 7.0.4
- Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P) versions antérieures à 7.0.4
- Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) versions antérieures à 7.0.4
- Network Management Card 2 for Modular 150/175kVA PDU (XRDP) versions antérieures à 7.0.4
- Network Management Card 2 for 400 and 500 kVA (PMM) versions antérieures à 7.0.4
- Network Management Card 2 for Modular PDU (XRDP2G) versions antérieures à 7.0.4
- Rack Automatic Transfer Switches (ATS) utilisant NMC2 AOS versions antérieures à 7.0.4
- Network Management Card 2 (NMC2) Cooling Products utilisant NMC2 AOS versions antérieures à 7.0.4
- Environmental Monitoring Unit with embedded NMC2 (NB250) utilisant NMC2 AOS versions antérieures à 7.0.4
- Network Management Card 2 (NMC2) versions antérieures à 7.0.4
- EcoStruxure Micro Data Center utilisant NMC2 AOS versions antérieures à 7.0.4
Les produits suivants ne sont plus supportés par l'éditeur :
- Wiser Smart EER21000 et EER21001 versions antérieures à 4.5
Les produits suivants ne bénéficient pas encore de correctif pour les vulnérabilités CVE-2022-22805, CVE-2022-22806 et CVE-2022-0715 :
- Smart-UPS séries SMT, SMC, SCL, SMX, SRT, SRC, XU, et SRTL
| Vendor | Product | Description |
|---|
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [],
"affected_systems_content": "\u003cul\u003e \u003cli\u003ePowerLogic ION Setup versions ant\u00e9rieures \u00e0 3.2.22096.01\u003c/li\u003e \u003cli\u003eSaitel DP RTU microgiciel versions Baseline_09.00.00 \u00e0 Baseline_11.06.23 ant\u00e9rieures \u00e0 BaseLine_11.06.24\u003c/li\u003e \u003cli\u003eAPC Smart-UPS SRC Series ID=1004: UPS versions 14.9 et ant\u00e9rieures\u003c/li\u003e \u003cli\u003eAPC Smart-UPS SRC Series ID=1006: UPS versions 14.9 et ant\u00e9rieures\u003c/li\u003e \u003cli\u003eAPC Smart-UPS SRC Series ID=1011: UPS versions 14.9 et ant\u00e9rieures\u003c/li\u003e \u003cli\u003eAPC Smart-UPS SRC Series ID=1033: UPS versions 00.3 et ant\u00e9rieures\u003c/li\u003e \u003cli\u003eAPC Smart-UPS XU Series SRC Series ID=1017: UPS versions 02.6 et ant\u00e9rieures\u003c/li\u003e \u003cli\u003eSmartConnect s\u00e9ries SMTL, SCL, et SMX version du microgiciel ant\u00e9rieure \u00e0 15.0\u003c/li\u003e \u003cli\u003eHMISCU Vijeo Designer versions ant\u00e9rieures \u00e0 6.2 SP12\u003c/li\u003e \u003cli\u003eEasergy MiCOM P30 range mod\u00e8les C434, P132, P139, P433, P435, P437, P532, P631, P632, P633, P634 et Px36/8 versions 660 \u00e0 674\u003c/li\u003e \u003cli\u003eAPC Rack Power Distribution Units (PDU) utilisant NMC2 AOS versions ant\u00e9rieures \u00e0 7.0.6\u003c/li\u003e \u003cli\u003eAPC Rack Power Distribution Units (PDU) utilisant NMC3 AOS versions ant\u00e9rieures \u00e0 1.2.0.2\u003c/li\u003e \u003cli\u003eAPC 3-Phase Power Distribution Products utilisant NMC2 AOS versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P) versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 for Modular 150/175kVA PDU (XRDP) versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 for 400 and 500 kVA (PMM) versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 for Modular PDU (XRDP2G) versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eRack Automatic Transfer Switches (ATS) utilisant NMC2 AOS versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 (NMC2) Cooling Products utilisant NMC2 AOS versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eEnvironmental Monitoring Unit with embedded NMC2 (NB250) utilisant NMC2 AOS versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eNetwork Management Card 2 (NMC2) versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003cli\u003eEcoStruxure Micro Data Center utilisant NMC2 AOS versions ant\u00e9rieures \u00e0 7.0.4\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eLes produits suivants ne sont plus support\u00e9s par l\u0027\u00e9diteur :\u003c/p\u003e \u003cul\u003e \u003cli\u003eWiser Smart EER21000 et EER21001 versions ant\u00e9rieures \u00e0 4.5\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eLes produits suivants ne b\u00e9n\u00e9ficient pas encore de correctif pour les vuln\u00e9rabilit\u00e9s CVE-2022-22805, CVE-2022-22806 et CVE-2022-0715 :\u003c/p\u003e \u003cul\u003e \u003cli\u003eSmart-UPS s\u00e9ries SMT, SMC, SCL, SMX, SRT, SRC, XU, et SRTL\u003c/li\u003e \u003c/ul\u003e ",
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-30236",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30236"
},
{
"name": "CVE-2021-22811",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22811"
},
{
"name": "CVE-2021-22813",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22813"
},
{
"name": "CVE-2022-30233",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30233"
},
{
"name": "CVE-2022-30238",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30238"
},
{
"name": "CVE-2022-6996",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-6996"
},
{
"name": "CVE-2021-22810",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22810"
},
{
"name": "CVE-2021-22815",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22815"
},
{
"name": "CVE-2022-22806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22806"
},
{
"name": "CVE-2022-30234",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30234"
},
{
"name": "CVE-2022-0715",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0715"
},
{
"name": "CVE-2021-22812",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22812"
},
{
"name": "CVE-2022-30232",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30232"
},
{
"name": "CVE-2020-6996",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-6996"
},
{
"name": "CVE-2022-30235",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30235"
},
{
"name": "CVE-2022-22805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22805"
},
{
"name": "CVE-2021-22814",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22814"
},
{
"name": "CVE-2022-30237",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30237"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-436",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-05-10T00:00:00.000000"
},
{
"description": "Mise \u00e0 jour des liens",
"revision_date": "2022-08-22T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Elles permettent \u00e0 un attaquant de provoquer une\nex\u00e9cution de code arbitraire \u00e0 distance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-130-01 du 10 mai 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-130-01_PowerLogic_ION_Setup_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-130-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-130-02 du 10 mai 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-130-02_Saitel_DP_RTU_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-130-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 10 mai 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_Badalloc_Vulnerabilities_Security_Notification_V7.0.pdf\u0026p_Doc_Ref=SEVD-2021-313-05"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-130-03 du 10 mai 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-130-03_WiserSmart_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-130-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-03 du 10 mai 2022",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-03_APC_NMC_Security_Notification_V2.0.pdf\u0026p_Doc_Ref=SEVD-2021-313-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-067-02 du 10 mai 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-067-02_APC-Smart-UPS_Security_Notification_V6.0.pdf"
}
]
}
FKIE_CVE-2020-6996
Vulnerability from fkie_nvd - Published: 2020-04-15 19:15 - Updated: 2024-11-21 05:36| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.us-cert.gov/ics/advisories/icsa-20-105-02 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-20-105-02 | Third Party Advisory, US Government Resource |
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | dnp3_source_code_library | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:dnp3_source_code_library:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6F97C26A-1C2B-4616-9DB1-109946BB64FF",
"versionEndIncluding": "3.25.01",
"versionStartIncluding": "3.16.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability."
},
{
"lang": "es",
"value": "Librer\u00edas de Triangle MicroWorks DNP3 Outstation Los componentes del Protocolo .NET Outstation DNP3 y las bibliotecas de c\u00f3digo fuente ANSI C de DNP3 Outstation se ven afectadas: 3.16.00 a 3.25.01. Un mensaje especialmente dise\u00f1ado puede causar un desbordamiento del b\u00fafer basado en la pila. No se requiere autenticaci\u00f3n para explotar esta vulnerabilidad."
}
],
"id": "CVE-2020-6996",
"lastModified": "2024-11-21T05:36:27.533",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-15T19:15:13.927",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CNVD-2020-28053
Vulnerability from cnvd - Published: 2020-05-13厂商已发布了漏洞修复程序,请及时关注更新: http://www.trianglemicroworks.com/
| Name | Triangle MicroWorks DNP3 Outstation Libraries >=3.16.00,<=3.25.01 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2020-6996"
}
},
"description": "Triangle MicroWorks DNP3 Outstation Libraries\u662f\u7f8e\u56fdTriangle MicroWorks\u516c\u53f8\u7684\u4e00\u6b3e\u80fd\u591f\u5728\u8bbe\u5907\u4e2d\u6dfb\u52a0\u5bf9\u884c\u4e1a\u6807\u51c6\u901a\u4fe1\u534f\u8bae\u7684\u652f\u6301\u7684\u8f6f\u4ef6\u5e93\u3002\n\nTriangle MicroWorks DNP3 Outstation Libraries 3.16.00\u7248\u672c\u81f33.25.01\u7248\u672c\u4e2d\u5b58\u5728\u7f13\u51b2\u533a\u5df2\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u7a0b\u5e8f\u672a\u80fd\u6b63\u786e\u8fdb\u884c\u8fb9\u754c\u68c0\u67e5\u3002\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u501f\u52a9\u7279\u5236\u6d88\u606f\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u7cfb\u7edf\u4e0a\u6267\u884c\u4efb\u610f\u4ee3\u7801\u6216\u5bfc\u81f4\u5e94\u7528\u7a0b\u5e8f\u5d29\u6e83\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttp://www.trianglemicroworks.com/",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2020-28053",
"openTime": "2020-05-13",
"patchDescription": "Triangle MicroWorks DNP3 Outstation Libraries\u662f\u7f8e\u56fdTriangle MicroWorks\u516c\u53f8\u7684\u4e00\u6b3e\u80fd\u591f\u5728\u8bbe\u5907\u4e2d\u6dfb\u52a0\u5bf9\u884c\u4e1a\u6807\u51c6\u901a\u4fe1\u534f\u8bae\u7684\u652f\u6301\u7684\u8f6f\u4ef6\u5e93\u3002\r\n\r\nTriangle MicroWorks DNP3 Outstation Libraries 3.16.00\u7248\u672c\u81f33.25.01\u7248\u672c\u4e2d\u5b58\u5728\u7f13\u51b2\u533a\u5df2\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u7a0b\u5e8f\u672a\u80fd\u6b63\u786e\u8fdb\u884c\u8fb9\u754c\u68c0\u67e5\u3002\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u501f\u52a9\u7279\u5236\u6d88\u606f\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u7cfb\u7edf\u4e0a\u6267\u884c\u4efb\u610f\u4ee3\u7801\u6216\u5bfc\u81f4\u5e94\u7528\u7a0b\u5e8f\u5d29\u6e83\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Triangle MicroWorks DNP3 Outstation Libraries\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Triangle MicroWorks DNP3 Outstation Libraries \u003e=3.16.00\uff0c\u003c=3.25.01"
},
"referenceLink": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02",
"serverity": "\u9ad8",
"submitTime": "2020-04-15",
"title": "Triangle MicroWorks DNP3 Outstation Libraries\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e"
}
GSD-2020-6996
Vulnerability from gsd - Updated: 2023-12-13 01:21{
"GSD": {
"alias": "CVE-2020-6996",
"description": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.",
"id": "GSD-2020-6996"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-6996"
],
"details": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.",
"id": "GSD-2020-6996",
"modified": "2023-12-13T01:21:54.708172Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-6996",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01",
"version": {
"version_data": [
{
"version_value": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "STACK-BASED BUFFER OVERFLOW CWE-121"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:trianglemicroworks:dnp3_source_code_library:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.25.01",
"versionStartIncluding": "3.16.00",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-6996"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2020-04-22T17:13Z",
"publishedDate": "2020-04-15T19:15Z"
}
}
}
CVE-2020-6996
Vulnerability from csaf_se - Published: 2022-05-10 00:00 - Updated: 2022-05-10 00:00Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in the Triangle MicroWorks DNP3 Outstation Libraries used in the Saitel DP RTU (Remote Terminal Unit).\r\nThe Saitel DP RTU (Remote Terminal Unit) is a modular platform for medium voltage and low voltage public distribution and transmission network management.\r\nFailure to apply the mitigations provided below may lead to a denial of service of the DNP3 communication resulting in a loss of remote access or a reboot of the device.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Saitel DP RTU - SEVD-2022-130-02 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-130-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2022-130-02.json"
},
{
"category": "self",
"summary": "Saitel DP RTU - SEVD-2022-130-02 PDF Version",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-130-02_Saitel_DP_RTU_Security_Notification.pdf"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Saitel DP RTU",
"tracking": {
"current_release_date": "2022-05-10T00:00:00.00Z",
"generator": {
"date": "2022-05-10T00:00:00.00Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.1"
}
},
"id": "SEVD-2022-130-02",
"initial_release_date": "2022-05-10T00:00:00.00Z",
"revision_history": [
{
"date": "2022-05-10T00:00:00.00Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": " \u003e=11.06.23|\u003c=09.00.00",
"product": {
"name": "Schneider Electric Saitel DP BaseLine\u003e=11.06.23|\u003c=09.00.00",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Saitel DP RTU"
},
{
"branches": [
{
"category": "product_version",
"name": "11.06.24",
"product": {
"name": "Schneider Electric Saitel DP RTU BaseLine 11.06.24",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Saitel DP RTU"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-6996",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "In the context of the Saitel DP RTU the vulnerability may lead to denial of service when an attacker gains access to the RTU communication network. CVSS score, provided above, is evaluated as Medium in the product context.\r\nFurther information on this CVE can be found at https://nvd.nist.gov/vuln/detail/CVE-2020-6996.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Saitel DP RTU BaseLine_11.06.24 includes a fix for this vulnerability and is available from your Schneider Electric Saitel sales contact.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2020-6996"
}
]
}
CVE-2020-6996
Vulnerability from csaf_se - Published: 2022-12-13 04:12 - Updated: 2022-12-13 04:12Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in the Triangle MicroWorks DNP3 Outstation\r\nLibraries used in the Saitel DR RTU (Remote Terminal Unit).\r\nThe SAITEL DR RTU is a field device, offering a solid and powerful platform for data acquisition,\r\ncommunication, automation and IED integration for distribution and transmission networks,\r\ngeneration sector and railway.\r\nFailure to apply the remediation provided below may lead to a denial of service of the DNP3\r\ncommunication and will result in a loss of remote access to the device.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Saitel DR RTU - SEVD-2022-347-02 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-347-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-02_SAITEL_DR_RTU_Security_Notification.pdf"
},
{
"category": "self",
"summary": "Saitel DR RTU - SEVD-2022-347-02 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-347-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2022-347-02.json"
},
{
"category": "self",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Saitel DR RTU",
"tracking": {
"current_release_date": "2022-12-13T04:12:25.000Z",
"generator": {
"date": "2022-12-13T04:22:05.155Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2022-347-02",
"initial_release_date": "2022-12-13T04:12:25.000Z",
"revision_history": [
{
"date": "2022-12-13T04:12:25.000Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c11.06.14",
"product": {
"name": "Schneider Electric SAITEL DR RTU version prior to 11.06.14",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SAITEL DR RTU"
},
{
"branches": [
{
"category": "product_version",
"name": "11.06.15",
"product": {
"name": "Schneider Electric SAITEL DR RTU version 11.06.15",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SAITEL DR RTU"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-6996",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "description",
"text": "A CWE-787: Out-of-bounds write vulnerability exists that could cause a denial of service when an attacker gains access to the RTU communication network.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version BaseLine_11.06.15 of Saitel DR RTU includes a fix for this vulnerability and is available from your Schneider Electric Saitel sales contact",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2020-6996"
}
]
}
ICSA-20-105-02
Vulnerability from csaf_cisa - Published: 2020-04-14 00:00 - Updated: 2020-04-14 00:00Notes
{
"document": {
"acknowledgments": [
{
"names": [
"Steven Seeley",
"Chris Anastasio"
],
"organization": "Incite",
"summary": "reporting this vulnerability to Triangle MicroWorks"
},
{
"organization": "Trend Micro \u0027s Zero Day Initiative",
"summary": "reporting this vulnerability to Triangle MicroWorks"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could possibly allow remote attackers to stop the execution of code on affected equipment.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Energy, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "United States",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-105-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-105-02.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-105-02 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-105-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Triangle MicroWorks DNP3 Outstation Libraries",
"tracking": {
"current_release_date": "2020-04-14T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-105-02",
"initial_release_date": "2020-04-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-04-14T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-105-02 Triangle MicroWorks DNP3 Outstation Libraries"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= 3.16.00 | \u003c= 3.25.01",
"product": {
"name": "DNP3 Outstation Libraries: 3.16.00 through 3.25.01",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "DNP3 Outstation Libraries"
}
],
"category": "vendor",
"name": "Triangle MicroWorks"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-6996",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.CVE-2020-6996 has been assigned to this vulnerability. A CVSS v3 base score of 7.5has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-6996"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Triangle Microworks recommends users update to Version 3.26.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Please contact Triangle MicroWorks support for additional details.",
"product_ids": [
"CSAFPID-0001"
],
"url": "mailto:support@trianglemicroworks.com"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
GHSA-MX68-P78J-FV2C
Vulnerability from github – Published: 2022-05-24 17:15 – Updated: 2022-05-24 17:15Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.
{
"affected": [],
"aliases": [
"CVE-2020-6996"
],
"database_specific": {
"cwe_ids": [],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-04-15T19:15:00Z",
"severity": "HIGH"
},
"details": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.",
"id": "GHSA-mx68-p78j-fv2c",
"modified": "2022-05-24T17:15:17Z",
"published": "2022-05-24T17:15:17Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-6996"
},
{
"type": "WEB",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02"
}
],
"schema_version": "1.4.0",
"severity": []
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.