cve-2020-29032
Vulnerability from cvelistv5
Published
2021-03-05 16:58
Modified
2024-09-16 16:32
Summary
Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022
Impacted products
Vendor Product Version
Secomea GateManager Version: all   < 9.4.621054022
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:48:01.434Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2021-06"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/#3737"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "GateManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.4.621054022",
              "status": "affected",
              "version": "all",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Tenable"
        }
      ],
      "datePublic": "2021-03-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-494",
              "description": "CWE-494 Download of Code Without Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-03-09T06:06:27",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2021-06"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/#3737"
        }
      ],
      "source": {
        "defect": [
          "RD-3737"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Add integrity check of GateManager firmware",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "DATE_PUBLIC": "2021-03-04T22:00:00.000Z",
          "ID": "CVE-2020-29032",
          "STATE": "PUBLIC",
          "TITLE": "Add integrity check of GateManager firmware"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "GateManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "all",
                            "version_value": "9.4.621054022"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Tenable"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-494 Download of Code Without Integrity Check"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tenable.com/security/research/tra-2021-06",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2021-06"
            },
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/#3737",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/#3737"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-3737"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2020-29032",
    "datePublished": "2021-03-05T16:58:27.148457Z",
    "dateReserved": "2020-11-24T00:00:00",
    "dateUpdated": "2024-09-16T16:32:33.185Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-29032\",\"sourceIdentifier\":\"VulnerabilityReporting@secomea.com\",\"published\":\"2021-03-05T17:15:13.937\",\"lastModified\":\"2024-11-21T05:23:34.187\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de Carga de C\u00f3digo Sin Comprobaci\u00f3n de integridad en el archivo de firmware de Secomea GateManager, permite a un atacante autenticado ejecutar c\u00f3digo malicioso en el servidor. Este problema afecta a: Secomea GateManager todas las versiones anteriores a 9.4.621054022\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"VulnerabilityReporting@secomea.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H\",\"baseScore\":8.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.7,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"VulnerabilityReporting@secomea.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-494\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-434\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:gatemanager_8250_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.4.621054022\",\"matchCriteriaId\":\"FCB5D947-8F29-47C8-9FCB-DF38087C39BC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:gatemanager_8250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5089C475-2013-4DF6-AD1E-12F576ACAE8E\"}]}]}],\"references\":[{\"url\":\"https://www.secomea.com/support/cybersecurity-advisory/#3737\",\"source\":\"VulnerabilityReporting@secomea.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2021-06\",\"source\":\"VulnerabilityReporting@secomea.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.secomea.com/support/cybersecurity-advisory/#3737\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2021-06\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.