CVE-2020-29032
Vulnerability from cvelistv5
Published
2021-03-05 16:58
Modified
2024-09-16 16:32
Severity ?
EPSS score ?
Summary
Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Secomea | GateManager |
Version: all < 9.4.621054022 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:48:01.434Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2021-06" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.secomea.com/support/cybersecurity-advisory/#3737" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "GateManager", "vendor": "Secomea", "versions": [ { "lessThan": "9.4.621054022", "status": "affected", "version": "all", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Tenable" } ], "datePublic": "2021-03-04T00:00:00", "descriptions": [ { "lang": "en", "value": "Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-494", "description": "CWE-494 Download of Code Without Integrity Check", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-09T06:06:27", "orgId": "f2815942-3388-4c08-ba09-6c15850fda90", "shortName": "Secomea" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2021-06" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.secomea.com/support/cybersecurity-advisory/#3737" } ], "source": { "defect": [ "RD-3737" ], "discovery": "EXTERNAL" }, "title": "Add integrity check of GateManager firmware", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "VulnerabilityReporting@secomea.com", "DATE_PUBLIC": "2021-03-04T22:00:00.000Z", "ID": "CVE-2020-29032", "STATE": "PUBLIC", "TITLE": "Add integrity check of GateManager firmware" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "GateManager", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "all", "version_value": "9.4.621054022" } ] } } ] }, "vendor_name": "Secomea" } ] } }, "credit": [ { "lang": "eng", "value": "Tenable" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-494 Download of Code Without Integrity Check" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2021-06", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2021-06" }, { "name": "https://www.secomea.com/support/cybersecurity-advisory/#3737", "refsource": "MISC", "url": "https://www.secomea.com/support/cybersecurity-advisory/#3737" } ] }, "source": { "defect": [ "RD-3737" ], "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90", "assignerShortName": "Secomea", "cveId": "CVE-2020-29032", "datePublished": "2021-03-05T16:58:27.148457Z", "dateReserved": "2020-11-24T00:00:00", "dateUpdated": "2024-09-16T16:32:33.185Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-29032\",\"sourceIdentifier\":\"VulnerabilityReporting@secomea.com\",\"published\":\"2021-03-05T17:15:13.937\",\"lastModified\":\"2024-11-21T05:23:34.187\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de Carga de C\u00f3digo Sin Comprobaci\u00f3n de integridad en el archivo de firmware de Secomea GateManager, permite a un atacante autenticado ejecutar c\u00f3digo malicioso en el servidor. Este problema afecta a: Secomea GateManager todas las versiones anteriores a 9.4.621054022\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"VulnerabilityReporting@secomea.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H\",\"baseScore\":8.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.7,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"VulnerabilityReporting@secomea.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-494\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-434\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:gatemanager_8250_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.4.621054022\",\"matchCriteriaId\":\"FCB5D947-8F29-47C8-9FCB-DF38087C39BC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:gatemanager_8250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5089C475-2013-4DF6-AD1E-12F576ACAE8E\"}]}]}],\"references\":[{\"url\":\"https://www.secomea.com/support/cybersecurity-advisory/#3737\",\"source\":\"VulnerabilityReporting@secomea.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2021-06\",\"source\":\"VulnerabilityReporting@secomea.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.secomea.com/support/cybersecurity-advisory/#3737\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2021-06\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.