GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2020-10630 (GCVE-0-2020-10630)

Vulnerability from cvelistv5 – Published: 2020-05-05 20:08 – Updated: 2024-08-04 11:06
VLAI
Summary
SAE IT-systems FW-50 Remote Telemetry Unit (RTU). The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output used as a webpage that is served to other users.
CWE
  • CWE-79 - IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION ('CROSS-SITE SCRIPTING') CWE-79
References
Impacted products
Vendor Product Version CPE status
n/a SAE IT-systems FW-50 Remote Telemetry Unit (RTU) Affected: FW-50 RTU, Series: 5 Series
Affected: CPU-type: CPU-5B
Affected: Hardware Revision: 2
Affected: CPLD Revision: 6
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:06:10.157Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/ICSA2012602"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SAE IT-systems FW-50 Remote Telemetry Unit (RTU)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "FW-50 RTU, Series: 5 Series"
            },
            {
              "status": "affected",
              "version": "CPU-type: CPU-5B"
            },
            {
              "status": "affected",
              "version": "Hardware Revision: 2"
            },
            {
              "status": "affected",
              "version": "CPLD Revision: 6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "SAE IT-systems FW-50 Remote Telemetry Unit (RTU). The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output used as a webpage that is served to other users."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION (\u0027CROSS-SITE SCRIPTING\u0027) CWE-79",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-05T20:08:18.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/ICSA2012602"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-10630",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SAE IT-systems FW-50 Remote Telemetry Unit (RTU)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "FW-50 RTU, Series: 5 Series"
                          },
                          {
                            "version_value": "CPU-type: CPU-5B"
                          },
                          {
                            "version_value": "Hardware Revision: 2"
                          },
                          {
                            "version_value": "CPLD Revision: 6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "SAE IT-systems FW-50 Remote Telemetry Unit (RTU). The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output used as a webpage that is served to other users."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION (\u0027CROSS-SITE SCRIPTING\u0027) CWE-79"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/ICSA2012602",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/ICSA2012602"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-10630",
    "datePublished": "2020-05-05T20:08:18.000Z",
    "dateReserved": "2020-03-16T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:06:10.157Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-10630",
      "date": "2026-09-16",
      "epss": "0.00687",
      "percentile": "0.50992"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:sae-it:net-line_fw-50_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"39B379C9-8EA5-4600-90F2-FC9F195707D6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:sae-it:net-line_fw-50:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D49F753C-463E-456F-B683-7E0B0322C745\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"SAE IT-systems FW-50 Remote Telemetry Unit (RTU). The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output used as a webpage that is served to other users.\"}, {\"lang\": \"es\", \"value\": \"SAE IT-systems FW-50 Remote Telemetry Unit (RTU). El software no neutraliza o neutraliza incorrectamente una entrada controlable por el usuario antes de que sea colocada en la salida usada como una p\\u00e1gina web que es servida a otros usuarios.\"}]",
      "id": "CVE-2020-10630",
      "lastModified": "2024-11-21T04:55:44.017",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:P/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2020-05-05T21:15:11.393",
      "references": "[{\"url\": \"https://www.us-cert.gov/ics/advisories/ICSA2012602\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Mitigation\", \"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.us-cert.gov/ics/advisories/ICSA2012602\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Third Party Advisory\", \"US Government Resource\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-10630\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-05-05T21:15:11.393\",\"lastModified\":\"2024-11-21T04:55:44.017\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"SAE IT-systems FW-50 Remote Telemetry Unit (RTU). The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output used as a webpage that is served to other users.\"},{\"lang\":\"es\",\"value\":\"SAE IT-systems FW-50 Remote Telemetry Unit (RTU). El software no neutraliza o neutraliza incorrectamente una entrada controlable por el usuario antes de que sea colocada en la salida usada como una p\u00e1gina web que es servida a otros usuarios.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sae-it:net-line_fw-50_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"39B379C9-8EA5-4600-90F2-FC9F195707D6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:sae-it:net-line_fw-50:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D49F753C-463E-456F-B683-7E0B0322C745\"}]}]}],\"references\":[{\"url\":\"https://www.us-cert.gov/ics/advisories/ICSA2012602\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/ICSA2012602\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…