cve-2018-5459
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01 | Third Party Advisory, US Government Resource |
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | WAGO PFC200 Series |
Version: WAGO PFC200 Series |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:33:44.375Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "WAGO PFC200 Series", "vendor": "n/a", "versions": [ { "status": "affected", "version": "WAGO PFC200 Series" } ] } ], "datePublic": "2018-02-13T00:00:00", "descriptions": [ { "lang": "en", "value": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-02-13T20:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2018-5459", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "WAGO PFC200 Series", "version": { "version_data": [ { "version_value": "WAGO PFC200 Series" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-287" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-5459", "datePublished": "2018-02-13T21:00:00", "dateReserved": "2018-01-12T00:00:00", "dateUpdated": "2024-08-05T05:33:44.375Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-5459\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2018-02-13T21:29:00.207\",\"lastModified\":\"2024-11-21T04:08:50.547\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.\"},{\"lang\":\"es\",\"value\":\"Se ha descubierto un problema de autenticaci\u00f3n indebida en WAGO PFC200 Series 3S CoDeSys Runtime, versiones 2.3.X y 2.4.X. Un atacante puede ejecutar diferentes operaciones remotas sin autenticaci\u00f3n gracias a la aplicaci\u00f3n CoDeSys Runtime, que est\u00e1 disponible en red por defecto en el puerto 2455. Un atacante podr\u00eda ejecutar algunos comandos sin autenticaci\u00f3n, como la lectura, escritura o eliminaci\u00f3n de archivos arbitrarios, as\u00ed como manipular la aplicaci\u00f3n PLC durante el tiempo de ejecuci\u00f3n mediante el env\u00edo de paquetes TCP especialmente manipulados al puerto 2455.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:pfc200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"02.07.07\\\\(10\\\\)\",\"matchCriteriaId\":\"047F293C-809E-4931-A018-54BCEBD4BD10\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8202:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"23B02096-81A5-4823-94F3-D87F389397DE\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8202\\\\/025-000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1FC647C3-A602-412F-A4DA-5ED092E2779C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8202\\\\/025-001:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F5B99800-C5E6-4001-BCBA-2DB5E3CF7D8D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8202\\\\/025-002:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DEF4C2B9-4C44-4F83-B0D5-220A1525D254\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8202\\\\/040-001:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4E35ACF-6C0A-4C9F-83A8-6CBAF927BE43\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8203:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EC428EC8-532A-4825-BCE3-C42A4BC01C68\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8203\\\\/025-000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2E35209-C3F2-4251-9CB5-094FA9B0D076\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8204:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7AF14BE1-1EB5-423B-9FE7-E401AEF92553\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8204\\\\/025-000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"40B3E682-F1FD-4ADD-B1B8-89D7BA93B3FD\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8206:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2E17ECC4-D7AE-485C-A2EF-4148817F9DB8\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8206\\\\/025-000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6196935C-97E0-40A2-AF06-03CB72E40B0E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8206\\\\/025-001:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1E2892D5-A691-48A9-ACC9-236A50E6A40E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8207:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DA98A0D9-B050-430B-96C5-15932438FD3A\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8207\\\\/025-000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F56DA20-D82B-48C7-B4AD-8534367E8D83\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8207\\\\/025-001:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5C5C4BAD-7268-4367-A112-60E1A2EF6AF3\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8208:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C86098FC-E63E-4676-8BA1-ADCA30795558\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:750-8208\\\\/025-000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8FFE4FF4-4EE4-493F-A8CF-968215142EF4\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"688A3248-7EAA-499D-A47C-A4D4900CDBD1\"}]}]}],\"references\":[{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
gsd-2018-5459
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2018-5459", "description": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.", "id": "GSD-2018-5459" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2018-5459" ], "details": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.", "id": "GSD-2018-5459", "modified": "2023-12-13T01:22:40.128086Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2018-5459", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "WAGO PFC200 Series", "version": { "version_data": [ { "version_value": "WAGO PFC200 Series" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-287" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:wago:pfc200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "02.07.07\\(10\\)", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:wago:750-8206\\/025-001:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8207:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8207\\/025-000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8207\\/025-001:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8202:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8202\\/025-001:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8204:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8206:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8208\\/025-000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8202\\/025-002:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8202\\/040-001:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8203:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8203\\/025-000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8202\\/025-000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8204\\/025-000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8206\\/025-000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:wago:750-8208:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2018-5459" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-287" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01", "refsource": "MISC", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01" } ] } }, "impact": { "baseMetricV2": { "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } }, "lastModifiedDate": "2019-10-09T23:41Z", "publishedDate": "2018-02-13T21:29Z" } } }
fkie_cve-2018-5459
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01 | Third Party Advisory, US Government Resource |
Vendor | Product | Version | |
---|---|---|---|
wago | pfc200_firmware | * | |
wago | 750-8202 | - | |
wago | 750-8202\/025-000 | - | |
wago | 750-8202\/025-001 | - | |
wago | 750-8202\/025-002 | - | |
wago | 750-8202\/040-001 | - | |
wago | 750-8203 | - | |
wago | 750-8203\/025-000 | - | |
wago | 750-8204 | - | |
wago | 750-8204\/025-000 | - | |
wago | 750-8206 | - | |
wago | 750-8206\/025-000 | - | |
wago | 750-8206\/025-001 | - | |
wago | 750-8207 | - | |
wago | 750-8207\/025-000 | - | |
wago | 750-8207\/025-001 | - | |
wago | 750-8208 | - | |
wago | 750-8208\/025-000 | - | |
wago | pfc200 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:wago:pfc200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "047F293C-809E-4931-A018-54BCEBD4BD10", "versionEndExcluding": "02.07.07\\(10\\)", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:wago:750-8202:-:*:*:*:*:*:*:*", "matchCriteriaId": "23B02096-81A5-4823-94F3-D87F389397DE", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8202\\/025-000:-:*:*:*:*:*:*:*", "matchCriteriaId": "1FC647C3-A602-412F-A4DA-5ED092E2779C", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8202\\/025-001:-:*:*:*:*:*:*:*", "matchCriteriaId": "F5B99800-C5E6-4001-BCBA-2DB5E3CF7D8D", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8202\\/025-002:-:*:*:*:*:*:*:*", "matchCriteriaId": "DEF4C2B9-4C44-4F83-B0D5-220A1525D254", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8202\\/040-001:-:*:*:*:*:*:*:*", "matchCriteriaId": "D4E35ACF-6C0A-4C9F-83A8-6CBAF927BE43", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8203:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC428EC8-532A-4825-BCE3-C42A4BC01C68", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8203\\/025-000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D2E35209-C3F2-4251-9CB5-094FA9B0D076", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8204:-:*:*:*:*:*:*:*", "matchCriteriaId": "7AF14BE1-1EB5-423B-9FE7-E401AEF92553", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8204\\/025-000:-:*:*:*:*:*:*:*", "matchCriteriaId": "40B3E682-F1FD-4ADD-B1B8-89D7BA93B3FD", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8206:-:*:*:*:*:*:*:*", "matchCriteriaId": "2E17ECC4-D7AE-485C-A2EF-4148817F9DB8", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8206\\/025-000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6196935C-97E0-40A2-AF06-03CB72E40B0E", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8206\\/025-001:-:*:*:*:*:*:*:*", "matchCriteriaId": "1E2892D5-A691-48A9-ACC9-236A50E6A40E", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8207:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA98A0D9-B050-430B-96C5-15932438FD3A", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8207\\/025-000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F56DA20-D82B-48C7-B4AD-8534367E8D83", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8207\\/025-001:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C5C4BAD-7268-4367-A112-60E1A2EF6AF3", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8208:-:*:*:*:*:*:*:*", "matchCriteriaId": "C86098FC-E63E-4676-8BA1-ADCA30795558", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:750-8208\\/025-000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8FFE4FF4-4EE4-493F-A8CF-968215142EF4", "vulnerable": false }, { "criteria": "cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*", "matchCriteriaId": "688A3248-7EAA-499D-A47C-A4D4900CDBD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455." }, { "lang": "es", "value": "Se ha descubierto un problema de autenticaci\u00f3n indebida en WAGO PFC200 Series 3S CoDeSys Runtime, versiones 2.3.X y 2.4.X. Un atacante puede ejecutar diferentes operaciones remotas sin autenticaci\u00f3n gracias a la aplicaci\u00f3n CoDeSys Runtime, que est\u00e1 disponible en red por defecto en el puerto 2455. Un atacante podr\u00eda ejecutar algunos comandos sin autenticaci\u00f3n, como la lectura, escritura o eliminaci\u00f3n de archivos arbitrarios, as\u00ed como manipular la aplicaci\u00f3n PLC durante el tiempo de ejecuci\u00f3n mediante el env\u00edo de paquetes TCP especialmente manipulados al puerto 2455." } ], "id": "CVE-2018-5459", "lastModified": "2024-11-21T04:08:50.547", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-02-13T21:29:00.207", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
ICSA-18-044-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Reid Wightman" ], "organization": "Dragos", "summary": "discovering the vulnerability in the CoDeSys Runtime application" }, { "names": [ "T. Weber" ], "organization": "SEC Consult", "summary": "reporting this vulnerability to WAGO" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "ATTENTION: Remotely exploitable/low skill level to exploit. Public exploits are available.", "title": "Risk evaluation" }, { "category": "other", "text": "Commercial Facilities, Critical Manufacturing, Energy, and Transportation Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "United States, Germany, Switzerland, Poland, China, and India", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: Restrict access to Port 2455; Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet; Locate control system networks and remote devices behind firewalls, and isolate them from the business network; When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the NCCIC Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT website.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-18-044-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-044-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-18-044-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-044-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/" } ], "title": "WAGO PFC200 Series", "tracking": { "current_release_date": "2018-02-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-18-044-01", "initial_release_date": "2018-02-13T00:00:00.000000Z", "revision_history": [ { "date": "2018-02-13T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-18-044-01 WAGO PFC200 Series" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8207/025-001: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "750-8207/025-001" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8207: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "750-8207" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8202/040-001: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "750-8202/040-001" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8206/025-000: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "750-8206/025-000" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8206/025-001: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "750-8206/025-001" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8202/025-002: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "750-8202/025-002" }, { "branches": [ { "category": "product_version", "name": "2.4.X", "product": { "name": "CoDeSys: Version 2.4.X", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "CoDeSys" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8208: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "750-8208" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8204: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "750-8204" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8203/025-000: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "750-8203/025-000" }, { "branches": [ { "category": "product_version", "name": "2.3.X", "product": { "name": "CoDeSys: Version 2.3.X", "product_id": "CSAFPID-00011" } } ], "category": "product_name", "name": "CoDeSys" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8203: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00012" } } ], "category": "product_name", "name": "750-8203" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8206: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00013" } } ], "category": "product_name", "name": "750-8206" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8208/025-000: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00014" } } ], "category": "product_name", "name": "750-8208/025-000" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8202/025-001: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00015" } } ], "category": "product_name", "name": "750-8202/025-001" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8202/025-000: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00016" } } ], "category": "product_name", "name": "750-8202/025-000" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8204/025-000: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00017" } } ], "category": "product_name", "name": "750-8204/025-000" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8207/025-000: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00018" } } ], "category": "product_name", "name": "750-8207/025-000" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8202: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00019" } } ], "category": "product_name", "name": "750-8202" } ], "category": "vendor", "name": "WAGO" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-5459", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455. CVE-2018-5459 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-5459" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "WAGO released a security patch with FW11 available at:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019" ], "url": "http://global.wago.com/media/2_products/security/Sec-Advisory_CoDeSys.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019" ] } ] } ] }
icsa-18-044-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Reid Wightman" ], "organization": "Dragos", "summary": "discovering the vulnerability in the CoDeSys Runtime application" }, { "names": [ "T. Weber" ], "organization": "SEC Consult", "summary": "reporting this vulnerability to WAGO" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "ATTENTION: Remotely exploitable/low skill level to exploit. Public exploits are available.", "title": "Risk evaluation" }, { "category": "other", "text": "Commercial Facilities, Critical Manufacturing, Energy, and Transportation Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "United States, Germany, Switzerland, Poland, China, and India", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should: Restrict access to Port 2455; Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet; Locate control system networks and remote devices behind firewalls, and isolate them from the business network; When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the NCCIC Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT website.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-18-044-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2018/icsa-18-044-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-18-044-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-18-044-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/" } ], "title": "WAGO PFC200 Series", "tracking": { "current_release_date": "2018-02-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-18-044-01", "initial_release_date": "2018-02-13T00:00:00.000000Z", "revision_history": [ { "date": "2018-02-13T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-18-044-01 WAGO PFC200 Series" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8207/025-001: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "750-8207/025-001" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8207: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "750-8207" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8202/040-001: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "750-8202/040-001" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8206/025-000: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "750-8206/025-000" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8206/025-001: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "750-8206/025-001" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8202/025-002: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "750-8202/025-002" }, { "branches": [ { "category": "product_version", "name": "2.4.X", "product": { "name": "CoDeSys: Version 2.4.X", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "CoDeSys" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8208: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "750-8208" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8204: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "750-8204" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8203/025-000: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "750-8203/025-000" }, { "branches": [ { "category": "product_version", "name": "2.3.X", "product": { "name": "CoDeSys: Version 2.3.X", "product_id": "CSAFPID-00011" } } ], "category": "product_name", "name": "CoDeSys" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8203: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00012" } } ], "category": "product_name", "name": "750-8203" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8206: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00013" } } ], "category": "product_name", "name": "750-8206" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8208/025-000: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00014" } } ], "category": "product_name", "name": "750-8208/025-000" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8202/025-001: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00015" } } ], "category": "product_name", "name": "750-8202/025-001" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8202/025-000: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00016" } } ], "category": "product_name", "name": "750-8202/025-000" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8204/025-000: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00017" } } ], "category": "product_name", "name": "750-8204/025-000" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8207/025-000: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00018" } } ], "category": "product_name", "name": "750-8207/025-000" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 02.07.07(10)", "product": { "name": "750-8202: Firmware prior to 02.07.07(10)", "product_id": "CSAFPID-00019" } } ], "category": "product_name", "name": "750-8202" } ], "category": "vendor", "name": "WAGO" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-5459", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455. CVE-2018-5459 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-5459" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "WAGO released a security patch with FW11 available at:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019" ], "url": "http://global.wago.com/media/2_products/security/Sec-Advisory_CoDeSys.pdf" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013", "CSAFPID-00014", "CSAFPID-00015", "CSAFPID-00016", "CSAFPID-00017", "CSAFPID-00018", "CSAFPID-00019" ] } ] } ] }
ghsa-qff4-8m6q-cpvp
Vulnerability from github
An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.
{ "affected": [], "aliases": [ "CVE-2018-5459" ], "database_specific": { "cwe_ids": [ "CWE-287" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2018-02-13T21:29:00Z", "severity": "CRITICAL" }, "details": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.", "id": "GHSA-qff4-8m6q-cpvp", "modified": "2022-05-13T01:32:07Z", "published": "2022-05-13T01:32:07Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2018-5459" }, { "type": "WEB", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-044-01" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
var-201802-1047
Vulnerability from variot
An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455. WAGO PFC200 series 3S CoDeSys Runtime Contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. WAGO PFC200 is a bus editable logic controller module from WAGO, Germany
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201802-1047", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "pfc200", "scope": "lt", "trust": 1.0, "vendor": "wago", "version": "02.07.07\\(10\\)" }, { "model": "pfc200", "scope": null, "trust": 0.8, "vendor": "wago", "version": null }, { "model": "pfc200 series 3s codesys runtime", "scope": "eq", "trust": 0.6, "vendor": "wago", "version": "2.3.x" }, { "model": "pfc200 series 3s codesys runtime", "scope": "eq", "trust": 0.6, "vendor": "wago", "version": "2.4.x" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "pfc200", "version": "*" } ], "sources": [ { "db": "IVD", "id": "e2e3edcf-39ab-11e9-a1cc-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-03481" }, { "db": "JVNDB", "id": "JVNDB-2018-002446" }, { "db": "NVD", "id": "CVE-2018-5459" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:wago:pfc200_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-002446" } ] }, "cve": "CVE-2018-5459", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2018-5459", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2018-03481", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "e2e3edcf-39ab-11e9-a1cc-000c29342cb1", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2018-5459", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-5459", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2018-5459", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2018-03481", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201802-950", "trust": 0.6, "value": "CRITICAL" }, { "author": "IVD", "id": "e2e3edcf-39ab-11e9-a1cc-000c29342cb1", "trust": 0.2, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2018-5459", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "e2e3edcf-39ab-11e9-a1cc-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-03481" }, { "db": "VULMON", "id": "CVE-2018-5459" }, { "db": "JVNDB", "id": "JVNDB-2018-002446" }, { "db": "CNNVD", "id": "CNNVD-201802-950" }, { "db": "NVD", "id": "CVE-2018-5459" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455. WAGO PFC200 series 3S CoDeSys Runtime Contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. WAGO PFC200 is a bus editable logic controller module from WAGO, Germany", "sources": [ { "db": "NVD", "id": "CVE-2018-5459" }, { "db": "JVNDB", "id": "JVNDB-2018-002446" }, { "db": "CNVD", "id": "CNVD-2018-03481" }, { "db": "IVD", "id": "e2e3edcf-39ab-11e9-a1cc-000c29342cb1" }, { "db": "VULMON", "id": "CVE-2018-5459" } ], "trust": 2.43 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-5459", "trust": 3.3 }, { "db": "ICS CERT", "id": "ICSA-18-044-01", "trust": 3.1 }, { "db": "CNVD", "id": "CNVD-2018-03481", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201802-950", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2018-002446", "trust": 0.8 }, { "db": "IVD", "id": "E2E3EDCF-39AB-11E9-A1CC-000C29342CB1", "trust": 0.2 }, { "db": "VULMON", "id": "CVE-2018-5459", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "e2e3edcf-39ab-11e9-a1cc-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-03481" }, { "db": "VULMON", "id": "CVE-2018-5459" }, { "db": "JVNDB", "id": "JVNDB-2018-002446" }, { "db": "CNNVD", "id": "CNNVD-201802-950" }, { "db": "NVD", "id": "CVE-2018-5459" } ] }, "id": "VAR-201802-1047", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "e2e3edcf-39ab-11e9-a1cc-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-03481" } ], "trust": 1.57459148 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "e2e3edcf-39ab-11e9-a1cc-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-03481" } ] }, "last_update_date": "2024-11-23T22:34:20.209000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "http://global.wago.com/jp/" }, { "title": "WAGO PFC200 Series Patch for Incorrect Authentication Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/117903" }, { "title": "WAGO PFC200 Series 3S CoDeSys Runtime Remediation measures for authorization problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=100278" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-03481" }, { "db": "JVNDB", "id": "JVNDB-2018-002446" }, { "db": "CNNVD", "id": "CNNVD-201802-950" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-287", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-002446" }, { "db": "NVD", "id": "CVE-2018-5459" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.2, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-044-01" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-5459" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-5459" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://tools.cisco.com/security/center/viewalert.x?alertid=56812" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-03481" }, { "db": "VULMON", "id": "CVE-2018-5459" }, { "db": "JVNDB", "id": "JVNDB-2018-002446" }, { "db": "CNNVD", "id": "CNNVD-201802-950" }, { "db": "NVD", "id": "CVE-2018-5459" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "e2e3edcf-39ab-11e9-a1cc-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-03481" }, { "db": "VULMON", "id": "CVE-2018-5459" }, { "db": "JVNDB", "id": "JVNDB-2018-002446" }, { "db": "CNNVD", "id": "CNNVD-201802-950" }, { "db": "NVD", "id": "CVE-2018-5459" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-02-26T00:00:00", "db": "IVD", "id": "e2e3edcf-39ab-11e9-a1cc-000c29342cb1" }, { "date": "2018-02-26T00:00:00", "db": "CNVD", "id": "CNVD-2018-03481" }, { "date": "2018-02-13T00:00:00", "db": "VULMON", "id": "CVE-2018-5459" }, { "date": "2018-04-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-002446" }, { "date": "2018-02-13T00:00:00", "db": "CNNVD", "id": "CNNVD-201802-950" }, { "date": "2018-02-13T21:29:00.207000", "db": "NVD", "id": "CVE-2018-5459" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-02-26T00:00:00", "db": "CNVD", "id": "CNVD-2018-03481" }, { "date": "2019-10-09T00:00:00", "db": "VULMON", "id": "CVE-2018-5459" }, { "date": "2018-04-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-002446" }, { "date": "2019-10-17T00:00:00", "db": "CNNVD", "id": "CNNVD-201802-950" }, { "date": "2024-11-21T04:08:50.547000", "db": "NVD", "id": "CVE-2018-5459" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201802-950" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "WAGO PFC200 series 3S CoDeSys Runtime Authentication vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-002446" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-201802-950" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.