cve-2017-6867
Vulnerability from cvelistv5
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Siemens SIMATIC WinCC |
Version: Siemens SIMATIC WinCC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T15:41:17.675Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "98368", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/98368" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Siemens SIMATIC WinCC", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Siemens SIMATIC WinCC" } ] } ], "datePublic": "2017-05-10T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-06-13T09:57:01", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "98368", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/98368" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2017-6867", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Siemens SIMATIC WinCC", "version": { "version_data": [ { "version_value": "Siemens SIMATIC WinCC" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-787: Out-of-bounds Write" } ] } ] }, "references": { "reference_data": [ { "name": "98368", "refsource": "BID", "url": "http://www.securityfocus.com/bid/98368" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf" }, { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf", "refsource": "CONFIRM", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-6867", "datePublished": "2017-05-11T10:00:00", "dateReserved": "2017-03-13T00:00:00", "dateUpdated": "2024-08-05T15:41:17.675Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2017-6867\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2017-05-11T10:29:00.260\",\"lastModified\":\"2024-11-21T03:30:41.697\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \\\"administrators\\\" group to crash services by sending specially crafted messages to the DCOM interface.\"},{\"lang\":\"es\",\"value\":\"Se detect\u00f3 una vulnerabilidad en SIMATIC WinCC (versi\u00f3n V7.3 anterior a Upd 11 y versi\u00f3n V7.4 anterior a SP1), SIMATIC WinCC Runtime Professional (versi\u00f3n V13 anterior a SP2 y versi\u00f3n V14 anterior a SP1), SIMATIC WinCC (TIA Portal) Professional (versi\u00f3n V13 anterior a SP2 y versi\u00f3n V14 anterior a SP1) de Siemens, eso podr\u00eda permitir a un atacante remoto autenticado, quien es miembro del grupo de los \\\"administrators\\\" bloquear los servicios enviando mensajes especialmente dise\u00f1ados a la interfaz DCOM.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":4.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:N/I:N/A:P\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8D6229A2-9B8E-4F76-8425-589D2CE58B16\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F64B795A-7E66-49AE-BE40-E8EEAC12D280\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_\\\\(tia_portal\\\\):13:sp1:*:*:professional:*:*:*\",\"matchCriteriaId\":\"F8FA6B17-FA61-44FC-BAA7-AAC63ECBD996\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_\\\\(tia_portal\\\\):14:*:*:*:professional:*:*:*\",\"matchCriteriaId\":\"B0E21465-76ED-4803-A40A-539500B993F9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:*:*:professional:*:*:*\",\"matchCriteriaId\":\"57CE0216-AA81-416B-88D2-3321D2A2A16D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime:14:*:*:*:professional:*:*:*\",\"matchCriteriaId\":\"D8893E54-CF26-448A-9C32-90E5F8D8CC84\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/98368\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/98368\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
ICSA-17-129-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Sergey Temnikov", "Vladimir Dashchenko" ], "organization": "the Kaspersky Lab Critical Infrastructure Defense Team", "summary": "reporting this vulnerability directly to Siemens" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "ATTENTION: Remotely exploitable/low skill level to exploit.", "title": "Risk evaluation" }, { "category": "other", "text": "Food and Agriculture, Chemical, Energy, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the ICS -CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-129-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-129-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-129-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-129-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-129-03" } ], "title": "Siemens SIMATIC WinCC and SIMATIC WinCC Runtime Professional", "tracking": { "current_release_date": "2017-05-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-129-03", "initial_release_date": "2017-05-09T00:00:00.000000Z", "revision_history": [ { "date": "2017-05-09T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-129-03 Siemens SIMATIC WinCC" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 14 SP1", "product": { "name": "V14: All versions prior to V14 SP1", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional / SIMATIC WinCC (TIA Portal) Professional" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 13 SP2", "product": { "name": "V13: All versions prior to V13 SP2", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional / SIMATIC WinCC (TIA Portal) Professional" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 7.4 SP1", "product": { "name": "V7.4: All versions prior to V7.4 SP1", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SIMATIC WinCC" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 7.3 Update 11", "product": { "name": "V7.3: All versions prior to V7.3 Update 11", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "SIMATIC WinCC" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2017-6867", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An authenticated, remote attacker who is a member of the administrators group could crash services by sending specially crafted messages to the DCOM interface.CVE-2017-6867 has been assigned to this vulnerability. A CVSS v3 base score of 4.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-6867" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has released updates for the following products and strongly encourages users to upgrade to the new versions as soon as possible:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "https://support.industry.siemens.com/cs/ww/en/view/109746452", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746452" }, { "category": "vendor_fix", "details": "https://support.industry.siemens.com/cs/ww/en/view/109746038", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746038" }, { "category": "vendor_fix", "details": "https://support.industry.siemens.com/cs/ww/en/view/109746268", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746268" }, { "category": "vendor_fix", "details": "https://support.industry.siemens.com/cs/ww/en/view/109746276", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746276" }, { "category": "vendor_fix", "details": "https://support.industry.siemens.com/cs/ww/en/view/109746075", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746075" }, { "category": "vendor_fix", "details": "https://support.industry.siemens.com/cs/ww/en/view/109746074", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746074" }, { "category": "vendor_fix", "details": "For more information on this vulnerability and more detailed mitigation instructions, please see Siemens Security Advisory SSA-156872 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/en/cert-security-advisories.htm", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "http://www.siemens.com/cert/en/cert-security-advisories.htm" }, { "category": "vendor_fix", "details": "As a general security measure Siemens strongly recommends protecting network access to SIMATIC WinCC, SIMATIC WinCC Runtime, and SIMATIC WinCC (TIA Portal) Professional stations with appropriate mechanisms. Siemens advises configuring the environment according to Siemens operational guidelines in order to run the devices in a protected IT environment.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "https://www.siemens.com/cert/operational-guidelines-industrial-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ] } ] }
icsa-17-306-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Sergey Temnikov", "Vladimir Dashchenko" ], "organization": "Kaspersky Labs", "summary": "reporting the vulnerability to Siemens" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow a remote authenticated attacker to crash services on the devices.", "title": "Risk evaluation" }, { "category": "other", "text": "Chemical, Energy, Food and Agriculture, and Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and \nsolutions, please contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-306-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-306-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-306-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-306-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-496604: SSA-523365: Vulnerability in SIMATIC PCS 7 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/SSA-523365.txt" } ], "title": "Siemens SIMATIC PCS 7 (Update A)", "tracking": { "current_release_date": "2018-06-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-306-01", "initial_release_date": "2017-11-02T00:00:00.000000Z", "revision_history": [ { "date": "2017-11-02T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-306-01 Siemens SIMATIC PCS 7" }, { "date": "2018-06-12T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-17-306-01 Siemens SIMATIC PCS 7 (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V8.1 SP1 with WinCC V7.3 Upd 13", "product": { "name": "SIMATIC PCS 7 V8.1: All versions \u003c V8.1 SP1 with WinCC V7.3 Upd 13", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SIMATIC PCS 7 V8.1" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V8.2 SP1", "product": { "name": "SIMATIC PCS 7 V8.2: All versions \u003c V8.2 SP1", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SIMATIC PCS 7 V8.2" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2017-6867", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An authenticated, remote attacker who is member of the \"administrators\" group couldcrash services by sending specially crafted messages to the DCOM interface.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "remediations": [ { "category": "vendor_fix", "details": "Apply cell protection concept", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Use VPN for protecting network communication between cells", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Apply Defense-in-Depth", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update WinCC to V7.3 Upd 13 - Download: https://support.industry.siemens.com/cs/ww/en/view/109746452 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746452" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] } ] }
ICSA-17-306-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Sergey Temnikov", "Vladimir Dashchenko" ], "organization": "Kaspersky Labs", "summary": "reporting the vulnerability to Siemens" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow a remote authenticated attacker to crash services on the devices.", "title": "Risk evaluation" }, { "category": "other", "text": "Chemical, Energy, Food and Agriculture, and Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and \nsolutions, please contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-306-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-306-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-306-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-306-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-496604: SSA-523365: Vulnerability in SIMATIC PCS 7 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/SSA-523365.txt" } ], "title": "Siemens SIMATIC PCS 7 (Update A)", "tracking": { "current_release_date": "2018-06-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-306-01", "initial_release_date": "2017-11-02T00:00:00.000000Z", "revision_history": [ { "date": "2017-11-02T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-306-01 Siemens SIMATIC PCS 7" }, { "date": "2018-06-12T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-17-306-01 Siemens SIMATIC PCS 7 (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V8.1 SP1 with WinCC V7.3 Upd 13", "product": { "name": "SIMATIC PCS 7 V8.1: All versions \u003c V8.1 SP1 with WinCC V7.3 Upd 13", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SIMATIC PCS 7 V8.1" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V8.2 SP1", "product": { "name": "SIMATIC PCS 7 V8.2: All versions \u003c V8.2 SP1", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SIMATIC PCS 7 V8.2" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2017-6867", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An authenticated, remote attacker who is member of the \"administrators\" group couldcrash services by sending specially crafted messages to the DCOM interface.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "remediations": [ { "category": "vendor_fix", "details": "Apply cell protection concept", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Use VPN for protecting network communication between cells", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Apply Defense-in-Depth", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update WinCC to V7.3 Upd 13 - Download: https://support.industry.siemens.com/cs/ww/en/view/109746452 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746452" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] } ] }
icsa-17-129-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Sergey Temnikov", "Vladimir Dashchenko" ], "organization": "the Kaspersky Lab Critical Infrastructure Defense Team", "summary": "reporting this vulnerability directly to Siemens" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "ATTENTION: Remotely exploitable/low skill level to exploit.", "title": "Risk evaluation" }, { "category": "other", "text": "Food and Agriculture, Chemical, Energy, Water and Wastewater Systems", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the ICS -CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-129-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-129-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-129-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-129-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-129-03" } ], "title": "Siemens SIMATIC WinCC and SIMATIC WinCC Runtime Professional", "tracking": { "current_release_date": "2017-05-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-129-03", "initial_release_date": "2017-05-09T00:00:00.000000Z", "revision_history": [ { "date": "2017-05-09T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-129-03 Siemens SIMATIC WinCC" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 14 SP1", "product": { "name": "V14: All versions prior to V14 SP1", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional / SIMATIC WinCC (TIA Portal) Professional" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 13 SP2", "product": { "name": "V13: All versions prior to V13 SP2", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Professional / SIMATIC WinCC (TIA Portal) Professional" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 7.4 SP1", "product": { "name": "V7.4: All versions prior to V7.4 SP1", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SIMATIC WinCC" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 7.3 Update 11", "product": { "name": "V7.3: All versions prior to V7.3 Update 11", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "SIMATIC WinCC" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2017-6867", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An authenticated, remote attacker who is a member of the administrators group could crash services by sending specially crafted messages to the DCOM interface.CVE-2017-6867 has been assigned to this vulnerability. A CVSS v3 base score of 4.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2017-6867" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has released updates for the following products and strongly encourages users to upgrade to the new versions as soon as possible:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "https://support.industry.siemens.com/cs/ww/en/view/109746452", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746452" }, { "category": "vendor_fix", "details": "https://support.industry.siemens.com/cs/ww/en/view/109746038", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746038" }, { "category": "vendor_fix", "details": "https://support.industry.siemens.com/cs/ww/en/view/109746268", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746268" }, { "category": "vendor_fix", "details": "https://support.industry.siemens.com/cs/ww/en/view/109746276", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746276" }, { "category": "vendor_fix", "details": "https://support.industry.siemens.com/cs/ww/en/view/109746075", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746075" }, { "category": "vendor_fix", "details": "https://support.industry.siemens.com/cs/ww/en/view/109746074", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109746074" }, { "category": "vendor_fix", "details": "For more information on this vulnerability and more detailed mitigation instructions, please see Siemens Security Advisory SSA-156872 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/en/cert-security-advisories.htm", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "http://www.siemens.com/cert/en/cert-security-advisories.htm" }, { "category": "vendor_fix", "details": "As a general security measure Siemens strongly recommends protecting network access to SIMATIC WinCC, SIMATIC WinCC Runtime, and SIMATIC WinCC (TIA Portal) Professional stations with appropriate mechanisms. Siemens advises configuring the environment according to Siemens operational guidelines in order to run the devices in a protected IT environment.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "https://www.siemens.com/cert/operational-guidelines-industrial-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ] } ] }
ghsa-f7g5-6g5q-8c2q
Vulnerability from github
A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface.
{ "affected": [], "aliases": [ "CVE-2017-6867" ], "database_specific": { "cwe_ids": [ "CWE-20" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2017-05-11T10:29:00Z", "severity": "MODERATE" }, "details": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface.", "id": "GHSA-f7g5-6g5q-8c2q", "modified": "2022-05-14T03:18:09Z", "published": "2022-05-14T03:18:09Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2017-6867" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf" }, { "type": "WEB", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/98368" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "type": "CVSS_V3" } ] }
gsd-2017-6867
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2017-6867", "description": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface.", "id": "GSD-2017-6867" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2017-6867" ], "details": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface.", "id": "GSD-2017-6867", "modified": "2023-12-13T01:21:09.862279Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2017-6867", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Siemens SIMATIC WinCC", "version": { "version_data": [ { "version_value": "Siemens SIMATIC WinCC" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-787: Out-of-bounds Write" } ] } ] }, "references": { "reference_data": [ { "name": "98368", "refsource": "BID", "url": "http://www.securityfocus.com/bid/98368" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf" }, { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf", "refsource": "CONFIRM", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14:*:*:*:professional:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13:sp1:*:*:professional:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:14:*:*:*:professional:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:*:*:professional:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2017-6867" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-20" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf" }, { "name": "98368", "refsource": "BID", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/98368" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf", "refsource": "CONFIRM", "tags": [], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf" } ] } }, "impact": { "baseMetricV2": { "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 4.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 1.2, "impactScore": 3.6 } }, "lastModifiedDate": "2018-06-14T01:29Z", "publishedDate": "2017-05-11T10:29Z" } } }
fkie_cve-2017-6867
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_wincc | 7.3 | |
siemens | simatic_wincc | 7.4 | |
siemens | simatic_wincc_\(tia_portal\) | 13 | |
siemens | simatic_wincc_\(tia_portal\) | 14 | |
siemens | simatic_wincc_runtime | 13 | |
siemens | simatic_wincc_runtime | 14 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*", "matchCriteriaId": "8D6229A2-9B8E-4F76-8425-589D2CE58B16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*", "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13:sp1:*:*:professional:*:*:*", "matchCriteriaId": "F8FA6B17-FA61-44FC-BAA7-AAC63ECBD996", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14:*:*:*:professional:*:*:*", "matchCriteriaId": "B0E21465-76ED-4803-A40A-539500B993F9", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:*:*:professional:*:*:*", "matchCriteriaId": "57CE0216-AA81-416B-88D2-3321D2A2A16D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:14:*:*:*:professional:*:*:*", "matchCriteriaId": "D8893E54-CF26-448A-9C32-90E5F8D8CC84", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface." }, { "lang": "es", "value": "Se detect\u00f3 una vulnerabilidad en SIMATIC WinCC (versi\u00f3n V7.3 anterior a Upd 11 y versi\u00f3n V7.4 anterior a SP1), SIMATIC WinCC Runtime Professional (versi\u00f3n V13 anterior a SP2 y versi\u00f3n V14 anterior a SP1), SIMATIC WinCC (TIA Portal) Professional (versi\u00f3n V13 anterior a SP2 y versi\u00f3n V14 anterior a SP1) de Siemens, eso podr\u00eda permitir a un atacante remoto autenticado, quien es miembro del grupo de los \"administrators\" bloquear los servicios enviando mensajes especialmente dise\u00f1ados a la interfaz DCOM." } ], "id": "CVE-2017-6867", "lastModified": "2024-11-21T03:30:41.697", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 4.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 1.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2017-05-11T10:29:00.260", "references": [ { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/98368" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/98368" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
var-201705-3974
Vulnerability from variot
A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface. Siemens SIMATIC WinCC and SIMATIC WinCC Runtime Professional are industrial automation products from Siemens AG. SIMATIC WinCC is a monitoring and data acquisition (SCADA) system. SIMATIC WinCC Runtime Professional is the control and monitoring of the operator's visual runtime platform machines and equipment. Multiple SIMATIC WinCC Products are prone to a denial-of-service vulnerability. The following products are vulnerable: SIMATIC WinCC 7.3 versions prior to 7.3 Update 11 SIMATIC WinCC 7.4 versions prior to 7.4 SP1 SIMATIC WinCC Runtime Professional 13 versions prior to 13 SP2 SIMATIC WinCC Runtime Professional 14 versions prior to 14 SP1 SIMATIC WinCC (TIA Portal) Professional 13 versions prior to 13 SP2 SIMATIC WinCC (TIA Portal) Professional 14 versions prior to 14 SP1. Siemens SIMATIC WinCC, etc. Siemens SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system; SIMATIC PCS 7 is a distributed process control system using WinCC. Security vulnerabilities exist in several Siemens products
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201705-3974", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc", "scope": "eq", "trust": 1.9, "vendor": "siemens", "version": "7.4" }, { "model": "simatic wincc", "scope": "eq", "trust": 1.9, "vendor": "siemens", "version": "7.3" }, { "model": "simatic wincc \\", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc runtime", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc \\", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc runtime", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "14 sp1" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "7.3 update 11" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "7.4 sp1" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "7.3" }, { "model": "simatic wincc runtime professional", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "14 sp1" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "13 sp2" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "7.4" }, { "model": "simatic wincc", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "13 sp2" }, { "model": "simatic wincc runtime professional", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc upd", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v7.311" }, { "model": "simatic wincc sp1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v7.4" }, { "model": "simatic wincc runtime professional sp2", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v13" }, { "model": "simatic wincc runtime professional sp1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v14" }, { "model": "simatic wincc professional sp2", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v13" }, { "model": "simatic wincc professional sp1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v14" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc professional", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc update", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7.32" }, { "model": "simatic wincc update", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7.310" }, { "model": "simatic wincc update", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7.31" }, { "model": "simatic wincc runtime professional sp1", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc runtime professional sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc professional sp1", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "14" }, { "model": "simatic wincc professional sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "13" }, { "model": "simatic wincc sp1", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "7.4" }, { "model": "simatic wincc update", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "7.311" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc", "version": "7.3" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc", "version": "7.4" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc tia portal", "version": "13" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc tia portal", "version": "14" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc runtime", "version": "13" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc runtime", "version": "14" } ], "sources": [ { "db": "IVD", "id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39" }, { "db": "CNVD", "id": "CNVD-2017-06154" }, { "db": "BID", "id": "98368" }, { "db": "JVNDB", "id": "JVNDB-2017-004058" }, { "db": "CNNVD", "id": "CNNVD-201703-630" }, { "db": "NVD", "id": "CVE-2017-6867" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/a:siemens:simatic_wincc", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-004058" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Sergey Temnikov and Vladimir Dashchenko of the Kaspersky Lab Critical Infrastructure Defense Team", "sources": [ { "db": "BID", "id": "98368" } ], "trust": 0.3 }, "cve": "CVE-2017-6867", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 4.0, "confidentialityImpact": "NONE", "exploitabilityScore": 8.0, "id": "CVE-2017-6867", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2017-06154", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 4.0, "confidentialityImpact": "NONE", "exploitabilityScore": 8.0, "id": "VHN-115070", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:S/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 1.2, "id": "CVE-2017-6867", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2017-6867", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2017-6867", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2017-06154", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201703-630", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-115070", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39" }, { "db": "CNVD", "id": "CNVD-2017-06154" }, { "db": "VULHUB", "id": "VHN-115070" }, { "db": "JVNDB", "id": "JVNDB-2017-004058" }, { "db": "CNNVD", "id": "CNNVD-201703-630" }, { "db": "NVD", "id": "CVE-2017-6867" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface. Siemens SIMATIC WinCC and SIMATIC WinCC Runtime Professional are industrial automation products from Siemens AG. SIMATIC WinCC is a monitoring and data acquisition (SCADA) system. SIMATIC WinCC Runtime Professional is the control and monitoring of the operator\u0027s visual runtime platform machines and equipment. Multiple SIMATIC WinCC Products are prone to a denial-of-service vulnerability. \nThe following products are vulnerable:\nSIMATIC WinCC 7.3 versions prior to 7.3 Update 11\nSIMATIC WinCC 7.4 versions prior to 7.4 SP1\nSIMATIC WinCC Runtime Professional 13 versions prior to 13 SP2\nSIMATIC WinCC Runtime Professional 14 versions prior to 14 SP1\nSIMATIC WinCC (TIA Portal) Professional 13 versions prior to 13 SP2\nSIMATIC WinCC (TIA Portal) Professional 14 versions prior to 14 SP1. Siemens SIMATIC WinCC, etc. Siemens SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system; SIMATIC PCS 7 is a distributed process control system using WinCC. Security vulnerabilities exist in several Siemens products", "sources": [ { "db": "NVD", "id": "CVE-2017-6867" }, { "db": "JVNDB", "id": "JVNDB-2017-004058" }, { "db": "CNVD", "id": "CNVD-2017-06154" }, { "db": "BID", "id": "98368" }, { "db": "IVD", "id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39" }, { "db": "VULHUB", "id": "VHN-115070" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2017-6867", "trust": 3.6 }, { "db": "SIEMENS", "id": "SSA-156872", "trust": 2.3 }, { "db": "BID", "id": "98368", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-523365", "trust": 1.1 }, { "db": "CNNVD", "id": "CNNVD-201703-630", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2017-06154", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-17-306-01", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2017-004058", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-17-129-03", "trust": 0.3 }, { "db": "IVD", "id": "81C5D14F-8537-4B60-AA16-B99AEC0C6E39", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-115070", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39" }, { "db": "CNVD", "id": "CNVD-2017-06154" }, { "db": "VULHUB", "id": "VHN-115070" }, { "db": "BID", "id": "98368" }, { "db": "JVNDB", "id": "JVNDB-2017-004058" }, { "db": "CNNVD", "id": "CNNVD-201703-630" }, { "db": "NVD", "id": "CVE-2017-6867" } ] }, "id": "VAR-201705-3974", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39" }, { "db": "CNVD", "id": "CNVD-2017-06154" }, { "db": "VULHUB", "id": "VHN-115070" } ], "trust": 1.576931954 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39" }, { "db": "CNVD", "id": "CNVD-2017-06154" } ] }, "last_update_date": "2024-11-23T22:07:25.708000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-156872", "trust": 0.8, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf" }, { "title": "Patch for Siemens SIMATIC WinCC and SIMATIC WinCC Runtime Professional Denial of Service Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/176383" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-06154" }, { "db": "JVNDB", "id": "JVNDB-2017-004058" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-20", "trust": 1.9 }, { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "VULHUB", "id": "VHN-115070" }, { "db": "JVNDB", "id": "JVNDB-2017-004058" }, { "db": "NVD", "id": "CVE-2017-6867" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/98368" }, { "trust": 1.1, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-6867" }, { "trust": 0.8, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-306-01" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-6867" }, { "trust": 0.6, "url": "http://www.siemens.com/cert/en/cert-security-advisories.htm" }, { "trust": 0.3, "url": "http://www.siemens.com/" }, { "trust": 0.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-129-03" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-06154" }, { "db": "VULHUB", "id": "VHN-115070" }, { "db": "BID", "id": "98368" }, { "db": "JVNDB", "id": "JVNDB-2017-004058" }, { "db": "CNNVD", "id": "CNNVD-201703-630" }, { "db": "NVD", "id": "CVE-2017-6867" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39" }, { "db": "CNVD", "id": "CNVD-2017-06154" }, { "db": "VULHUB", "id": "VHN-115070" }, { "db": "BID", "id": "98368" }, { "db": "JVNDB", "id": "JVNDB-2017-004058" }, { "db": "CNNVD", "id": "CNNVD-201703-630" }, { "db": "NVD", "id": "CVE-2017-6867" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-05-09T00:00:00", "db": "IVD", "id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39" }, { "date": "2017-05-09T00:00:00", "db": "CNVD", "id": "CNVD-2017-06154" }, { "date": "2017-05-11T00:00:00", "db": "VULHUB", "id": "VHN-115070" }, { "date": "2017-05-09T00:00:00", "db": "BID", "id": "98368" }, { "date": "2017-06-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-004058" }, { "date": "2017-03-16T00:00:00", "db": "CNNVD", "id": "CNNVD-201703-630" }, { "date": "2017-05-11T10:29:00.260000", "db": "NVD", "id": "CVE-2017-6867" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-08-22T00:00:00", "db": "CNVD", "id": "CNVD-2017-06154" }, { "date": "2018-06-14T00:00:00", "db": "VULHUB", "id": "VHN-115070" }, { "date": "2017-05-23T16:23:00", "db": "BID", "id": "98368" }, { "date": "2018-06-13T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-004058" }, { "date": "2017-05-31T00:00:00", "db": "CNNVD", "id": "CNNVD-201703-630" }, { "date": "2024-11-21T03:30:41.697000", "db": "NVD", "id": "CVE-2017-6867" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201703-630" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens SIMATIC Vulnerability that can crash services in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-004058" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Input validation", "sources": [ { "db": "IVD", "id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39" }, { "db": "CNNVD", "id": "CNNVD-201703-630" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.