GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2017-11161 (GCVE-0-2017-11161)

Vulnerability from cvelistv5 – Published: 2017-09-08 14:00 – Updated: 2024-09-16 16:49
VLAI
Summary
Multiple SQL injection vulnerabilities in Synology Photo Station before 6.7.4-3433 and 6.3-2968 allow remote attackers to execute arbitrary SQL commands via the (1) article_id parameter to label.php; or (2) type parameter to synotheme.php.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command (CWE-89)
References
Impacted products
Vendor Product Version CPE status
Synology Synology Photo Station Affected: before 6.7.4-3433 and 6.3-2968
guessed Create a notification for this product.
Date Public
2017-09-08 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:57:57.989Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.synology.com/en-global/support/security/Synology_SA_17_35_PhotoStation"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Synology Photo Station",
          "vendor": "Synology",
          "versions": [
            {
              "status": "affected",
              "version": "before 6.7.4-3433 and 6.3-2968"
            }
          ]
        }
      ],
      "datePublic": "2017-09-08T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple SQL injection vulnerabilities in Synology Photo Station before 6.7.4-3433 and 6.3-2968 allow remote attackers to execute arbitrary SQL commands via the (1) article_id parameter to label.php; or (2) type parameter to synotheme.php."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "Improper Neutralization of Special Elements used in an SQL Command (CWE-89)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-09-08T13:57:01.000Z",
        "orgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
        "shortName": "synology"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.synology.com/en-global/support/security/Synology_SA_17_35_PhotoStation"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@synology.com",
          "DATE_PUBLIC": "2017-09-08T00:00:00",
          "ID": "CVE-2017-11161",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Synology Photo Station",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "before 6.7.4-3433 and 6.3-2968"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Synology"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple SQL injection vulnerabilities in Synology Photo Station before 6.7.4-3433 and 6.3-2968 allow remote attackers to execute arbitrary SQL commands via the (1) article_id parameter to label.php; or (2) type parameter to synotheme.php."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Neutralization of Special Elements used in an SQL Command (CWE-89)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.synology.com/en-global/support/security/Synology_SA_17_35_PhotoStation",
              "refsource": "CONFIRM",
              "url": "https://www.synology.com/en-global/support/security/Synology_SA_17_35_PhotoStation"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
    "assignerShortName": "synology",
    "cveId": "CVE-2017-11161",
    "datePublished": "2017-09-08T14:00:00.000Z",
    "dateReserved": "2017-07-10T00:00:00.000Z",
    "dateUpdated": "2024-09-16T16:49:11.244Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2017-11161",
      "date": "2026-09-20",
      "epss": "0.0124",
      "percentile": "0.67804"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:synology:photo_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "23EC868E-F493-4A58-B3D5-0D05F33725FD",
                  "versionEndIncluding": "6.3-2967",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:synology:photo_station:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9EDAA6AE-EA8A-4B2E-A36D-9EBC48BFC485",
                  "versionEndIncluding": "6.7.3-3432",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple SQL injection vulnerabilities in Synology Photo Station before 6.7.4-3433 and 6.3-2968 allow remote attackers to execute arbitrary SQL commands via the (1) article_id parameter to label.php; or (2) type parameter to synotheme.php."
        },
        {
          "lang": "es",
          "value": "Existen m\u00faltiples vulnerabilidades de inyecci\u00f3n SQL en Synology Photo Station en versiones anteriores a la 6.7.4-3433 y 6.3-2968 que permiten que los atacantes remotos ejecuten comandos SQL arbitrarios mediante (1) el par\u00e1metro article_id en label.php; o (2) el par\u00e1metro type en synotheme.php."
        }
      ],
      "id": "CVE-2017-11161",
      "lastModified": "2024-11-21T03:07:13.980",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2017-09-08T14:29:00.213",
      "references": [
        {
          "source": "security@synology.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.synology.com/en-global/support/security/Synology_SA_17_35_PhotoStation"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.synology.com/en-global/support/security/Synology_SA_17_35_PhotoStation"
        }
      ],
      "sourceIdentifier": "security@synology.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-89"
            }
          ],
          "source": "security@synology.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-89"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:synology:photo_station:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "23EC868E-F493-4A58-B3D5-0D05F33725FD",
                    "versionEndIncluding": "6.3-2967",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:synology:photo_station:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9EDAA6AE-EA8A-4B2E-A36D-9EBC48BFC485",
                    "versionEndIncluding": "6.7.3-3432",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Multiple SQL injection vulnerabilities in Synology Photo Station before 6.7.4-3433 and 6.3-2968 allow remote attackers to execute arbitrary SQL commands via the (1) article_id parameter to label.php; or (2) type parameter to synotheme.php."
          },
          {
            "lang": "es",
            "value": "Existen m\u00faltiples vulnerabilidades de inyecci\u00f3n SQL en Synology Photo Station en versiones anteriores a la 6.7.4-3433 y 6.3-2968 que permiten que los atacantes remotos ejecuten comandos SQL arbitrarios mediante (1) el par\u00e1metro article_id en label.php; o (2) el par\u00e1metro type en synotheme.php."
          }
        ],
        "id": "CVE-2017-11161",
        "lastModified": "2026-05-13T00:24:29.033",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2017-09-08T14:29:00.213",
        "references": [
          {
            "source": "security@synology.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.synology.com/en-global/support/security/Synology_SA_17_35_PhotoStation"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.synology.com/en-global/support/security/Synology_SA_17_35_PhotoStation"
          }
        ],
        "sourceIdentifier": "security@synology.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-89"
              }
            ],
            "source": "security@synology.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-89"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…