Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2016-20009
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/ | Exploit, Third Party Advisory | |
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/ | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf | Third Party Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T03:47:34.869Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-10T11:06:46", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf" } ], "tags": [ "unsupported-when-assigned" ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2016-20009", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "** UNSUPPORTED WHEN ASSIGNED ** A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/", "refsource": "MISC", "url": "https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2016-20009", "datePublished": "2021-03-11T21:39:25", "dateReserved": "2021-03-11T00:00:00", "dateUpdated": "2024-08-06T03:47:34.869Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2016-20009\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-03-11T22:15:12.120\",\"lastModified\":\"2024-11-21T02:47:32.740\",\"vulnStatus\":\"Modified\",\"cveTags\":[{\"sourceIdentifier\":\"cve@mitre.org\",\"tags\":[\"unsupported-when-assigned\"]}],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer\"},{\"lang\":\"es\",\"value\":\"** NO COMPATIBLE CUANDO SE ASIGN\u00d3 ** Un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria del cliente DNS en la funci\u00f3n ipdnsc_decode_name() afecta a Wind River VxWorks versiones 6.5 hasta 7. NOTA: Esta vulnerabilidad solo afecta a los productos que ya no son compatibles con el mantenedor\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.5\",\"versionEndIncluding\":\"7.0\",\"matchCriteriaId\":\"B41CC977-326E-4BEE-BC9A-93A64C8628D4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sgt-100_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"988EC5E4-0049-4072-A4BD-BD528C033805\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sgt-100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E678D371-C274-4E49-8485-AB3D1835B822\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sgt-200_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4F25DE38-9193-4350-9B1F-B6441AC7047B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sgt-200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CB1B10D2-C5E7-4C0D-9BED-606FB1C01276\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sgt-300_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FB59465A-3F1C-4035-B6BE-B4F8FAAAB4DC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sgt-300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"15B3EAEB-E209-4A6A-AA04-9497A8D47703\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sgt-400_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8B39AD60-6DCB-4466-A5AD-98ACCF1E08B2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sgt-400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8D3FA43D-2BDA-4CBC-B6CB-E674CECAC086\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sgt-a20_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"58C64347-8FB3-403D-A4BA-ABA5FE89AE4A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sgt-a20:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"23F32AEA-E2E9-417C-8C86-A08004F377C2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sgt-a35_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"32671BC6-DBED-41FB-B61F-553A70819FA0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sgt-a35:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1D3F0086-DF1D-4EFF-BA2A-8F9ED2A8FCAE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sgt-a65_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"15B1A88C-7FC3-456F-A0E5-157EADBF8012\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sgt-a65:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8F46F8C7-A7DD-4CD4-9DF8-04C7B9ABC89B\"}]}]}],\"references\":[{\"url\":\"https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
gsd-2016-20009
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2016-20009", "description": "** UNSUPPORTED WHEN ASSIGNED ** A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.", "id": "GSD-2016-20009" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2016-20009" ], "details": "** UNSUPPORTED WHEN ASSIGNED ** A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.", "id": "GSD-2016-20009", "modified": "2023-12-13T01:21:19.257803Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2016-20009", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "** UNSUPPORTED WHEN ASSIGNED ** A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/", "refsource": "MISC", "url": "https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf" } ] } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*", "matchCriteriaId": "B41CC977-326E-4BEE-BC9A-93A64C8628D4", "versionEndIncluding": "7.0", "versionStartIncluding": "6.5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "988EC5E4-0049-4072-A4BD-BD528C033805", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-100:-:*:*:*:*:*:*:*", "matchCriteriaId": "E678D371-C274-4E49-8485-AB3D1835B822", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4F25DE38-9193-4350-9B1F-B6441AC7047B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "CB1B10D2-C5E7-4C0D-9BED-606FB1C01276", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FB59465A-3F1C-4035-B6BE-B4F8FAAAB4DC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-300:-:*:*:*:*:*:*:*", "matchCriteriaId": "15B3EAEB-E209-4A6A-AA04-9497A8D47703", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B39AD60-6DCB-4466-A5AD-98ACCF1E08B2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-400:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D3FA43D-2BDA-4CBC-B6CB-E674CECAC086", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-a20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58C64347-8FB3-403D-A4BA-ABA5FE89AE4A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-a20:-:*:*:*:*:*:*:*", "matchCriteriaId": "23F32AEA-E2E9-417C-8C86-A08004F377C2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-a35_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32671BC6-DBED-41FB-B61F-553A70819FA0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-a35:-:*:*:*:*:*:*:*", "matchCriteriaId": "1D3F0086-DF1D-4EFF-BA2A-8F9ED2A8FCAE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-a65_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "15B1A88C-7FC3-456F-A0E5-157EADBF8012", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-a65:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F46F8C7-A7DD-4CD4-9DF8-04C7B9ABC89B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "descriptions": [ { "lang": "en", "value": "A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer" }, { "lang": "es", "value": "** NO COMPATIBLE CUANDO SE ASIGN\u00d3 ** Un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria del cliente DNS en la funci\u00f3n ipdnsc_decode_name() afecta a Wind River VxWorks versiones 6.5 hasta 7. NOTA: Esta vulnerabilidad solo afecta a los productos que ya no son compatibles con el mantenedor" } ], "id": "CVE-2016-20009", "lastModified": "2024-04-11T00:55:23.230", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-11T22:15:12.120", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] } } } }
icsa-21-222-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting to CISA that these products are affected by this vulnerability when using some third-party components" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could lead to remote code execution.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-553445: DNS \"Name:Wreck\" Vulnerabilities in Multiple Siemens Energy AGT and SGT solutions - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-553445.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-222-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-222-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-222-06 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-222-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ncas/tips/ST04-014" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-553445: DNS \"Name:Wreck\" Vulnerabilities in Multiple Siemens Energy AGT and SGT solutions - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf" }, { "category": "external", "summary": "SSA-553445: DNS \"Name:Wreck\" Vulnerabilities in Multiple Siemens Energy AGT and SGT solutions - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-553445.txt" } ], "title": "Siemens Energy AGT and SGT Solutions", "tracking": { "current_release_date": "2021-08-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-222-06", "initial_release_date": "2021-08-10T00:00:00.000000Z", "revision_history": [ { "date": "2021-08-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-222-06 Siemens Energy AGT and SGT Solutions" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-100", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SGT-100" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-200", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SGT-200" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-300", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SGT-300" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-400", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "SGT-400" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-A20", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "SGT-A20" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-A35", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "SGT-A35" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-A65", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "SGT-A65" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-20009", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "** UNSUPPORTED WHEN ASSIGNED ** A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, "references": [ { "summary": "CVE-2016-20009 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2016-20009.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-20009" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "As only Rockwell Automation / Allen Bradley components are affected, please see Rockwell Security Advisory PN1564 for affected parts and software/firmware updates. Some updates may not be compatible with other components in the system. Contact Siemens Energy for further support.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, { "category": "mitigation", "details": "While firmware updates are suggested in the original advisory as solutions, the updates may not be compatible with the software or other components in the system. Please contact your local Siemens Energy representative for an assessment.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, { "category": "mitigation", "details": "For more details on how to mitigate this vulnerability, see Rockwell Security Advisory PN1564 (https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1131196, Login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, { "category": "mitigation", "details": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design.\n\nSiemens Energy strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens Energy strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment.\n\nAs a general security measure Siemens Energy strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] } ], "title": "CVE-2016-20009" } ] }
ICSA-21-222-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting to CISA that these products are affected by this vulnerability when using some third-party components" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could lead to remote code execution.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-553445: DNS \"Name:Wreck\" Vulnerabilities in Multiple Siemens Energy AGT and SGT solutions - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-553445.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-222-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-222-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-222-06 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-222-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ncas/tips/ST04-014" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-553445: DNS \"Name:Wreck\" Vulnerabilities in Multiple Siemens Energy AGT and SGT solutions - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf" }, { "category": "external", "summary": "SSA-553445: DNS \"Name:Wreck\" Vulnerabilities in Multiple Siemens Energy AGT and SGT solutions - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-553445.txt" } ], "title": "Siemens Energy AGT and SGT Solutions", "tracking": { "current_release_date": "2021-08-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-222-06", "initial_release_date": "2021-08-10T00:00:00.000000Z", "revision_history": [ { "date": "2021-08-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-222-06 Siemens Energy AGT and SGT Solutions" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-100", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SGT-100" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-200", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SGT-200" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-300", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SGT-300" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-400", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "SGT-400" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-A20", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "SGT-A20" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-A35", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "SGT-A35" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SGT-A65", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "SGT-A65" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-20009", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "** UNSUPPORTED WHEN ASSIGNED ** A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, "references": [ { "summary": "CVE-2016-20009 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2016-20009.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-20009" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "As only Rockwell Automation / Allen Bradley components are affected, please see Rockwell Security Advisory PN1564 for affected parts and software/firmware updates. Some updates may not be compatible with other components in the system. Contact Siemens Energy for further support.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, { "category": "mitigation", "details": "While firmware updates are suggested in the original advisory as solutions, the updates may not be compatible with the software or other components in the system. Please contact your local Siemens Energy representative for an assessment.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, { "category": "mitigation", "details": "For more details on how to mitigate this vulnerability, see Rockwell Security Advisory PN1564 (https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1131196, Login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, { "category": "mitigation", "details": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design.\n\nSiemens Energy strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens Energy strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment.\n\nAs a general security measure Siemens Energy strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] } ], "title": "CVE-2016-20009" } ] }
fkie_cve-2016-20009
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/ | Exploit, Third Party Advisory | |
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/ | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf | Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
windriver | vxworks | * | |
siemens | sgt-100_firmware | * | |
siemens | sgt-100 | - | |
siemens | sgt-200_firmware | * | |
siemens | sgt-200 | - | |
siemens | sgt-300_firmware | * | |
siemens | sgt-300 | - | |
siemens | sgt-400_firmware | * | |
siemens | sgt-400 | - | |
siemens | sgt-a20_firmware | * | |
siemens | sgt-a20 | - | |
siemens | sgt-a35_firmware | * | |
siemens | sgt-a35 | - | |
siemens | sgt-a65_firmware | * | |
siemens | sgt-a65 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*", "matchCriteriaId": "B41CC977-326E-4BEE-BC9A-93A64C8628D4", "versionEndIncluding": "7.0", "versionStartIncluding": "6.5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "988EC5E4-0049-4072-A4BD-BD528C033805", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-100:-:*:*:*:*:*:*:*", "matchCriteriaId": "E678D371-C274-4E49-8485-AB3D1835B822", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4F25DE38-9193-4350-9B1F-B6441AC7047B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "CB1B10D2-C5E7-4C0D-9BED-606FB1C01276", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FB59465A-3F1C-4035-B6BE-B4F8FAAAB4DC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-300:-:*:*:*:*:*:*:*", "matchCriteriaId": "15B3EAEB-E209-4A6A-AA04-9497A8D47703", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B39AD60-6DCB-4466-A5AD-98ACCF1E08B2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-400:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D3FA43D-2BDA-4CBC-B6CB-E674CECAC086", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-a20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58C64347-8FB3-403D-A4BA-ABA5FE89AE4A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-a20:-:*:*:*:*:*:*:*", "matchCriteriaId": "23F32AEA-E2E9-417C-8C86-A08004F377C2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-a35_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32671BC6-DBED-41FB-B61F-553A70819FA0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-a35:-:*:*:*:*:*:*:*", "matchCriteriaId": "1D3F0086-DF1D-4EFF-BA2A-8F9ED2A8FCAE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sgt-a65_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "15B1A88C-7FC3-456F-A0E5-157EADBF8012", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sgt-a65:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F46F8C7-A7DD-4CD4-9DF8-04C7B9ABC89B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [ { "sourceIdentifier": "cve@mitre.org", "tags": [ "unsupported-when-assigned" ] } ], "descriptions": [ { "lang": "en", "value": "A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer" }, { "lang": "es", "value": "** NO COMPATIBLE CUANDO SE ASIGN\u00d3 ** Un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria del cliente DNS en la funci\u00f3n ipdnsc_decode_name() afecta a Wind River VxWorks versiones 6.5 hasta 7. NOTA: Esta vulnerabilidad solo afecta a los productos que ya no son compatibles con el mantenedor" } ], "id": "CVE-2016-20009", "lastModified": "2024-11-21T02:47:32.740", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-11T22:15:12.120", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
ghsa-347g-p4qh-9qw2
Vulnerability from github
** UNSUPPORTED WHEN ASSIGNED ** A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
{ "affected": [], "aliases": [ "CVE-2016-20009" ], "database_specific": { "cwe_ids": [ "CWE-787" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-03-11T22:15:00Z", "severity": "CRITICAL" }, "details": "** UNSUPPORTED WHEN ASSIGNED ** A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.", "id": "GHSA-347g-p4qh-9qw2", "modified": "2024-03-21T03:34:03Z", "published": "2022-05-24T17:44:14Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2016-20009" }, { "type": "WEB", "url": "https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
wid-sec-w-2023-1986
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "hoch" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "Nucleus Net ist der Netzwerk-Stack f\u00fcr das Nucleus RTOS Echtzeitbetriebssystem.\r\nNucleus RTOS ist ein Echtzeitbetriebssystem f\u00fcr Embedded Devices.\r\nAzure RTOS NetX ist ein TCP/IP IPv4 Embedded Network Stack, der f\u00fcr Embedded-, Echtzeit- und IoT-Anwendungen entwickelt wurde. \r\nVxWorks ist ein propriet\u00e4res Echtzeitbetriebssystem, das von Wind River Systems entwickelt wird.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Siemens Nucleus Net, Siemens Nucleus RTOS, Microsoft Azure RTOS NetX und Wind River VxWorks ausnutzen, um beliebigen Programmcode mit Administratorrechten auszuf\u00fchren oder einen Denial of Service zu verursachen.", "title": "Angriff" }, { "category": "general", "text": "- Sonstiges", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-1986 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2021/wid-sec-w-2023-1986.json" }, { "category": "self", "summary": "WID-SEC-2023-1986 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-1986" }, { "category": "external", "summary": "Forescout Report vom 2021-04-15", "url": "https://www.forescout.com/company/resources/namewreck-breaking-and-fixing-dns-implementations/" }, { "category": "external", "summary": "Siemens Security Advisory by Siemens ProductCERT", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf" }, { "category": "external", "summary": "Siemens Security Advisory by Siemens ProductCERT", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf" }, { "category": "external", "summary": "Siemens Security Advisory SSA-180579 vom 2023-08-08", "url": "https://cert-portal.siemens.com/productcert/html/ssa-180579.html" }, { "category": "external", "summary": "Siemens Security Advisory SSA-248289 vom 2024-02-13", "url": "https://cert-portal.siemens.com/productcert/html/ssa-248289.html" } ], "source_lang": "en-US", "title": "NAME:WRECK: Mehrere Schwachstellen in TCP/IP Stacks", "tracking": { "current_release_date": "2024-02-12T23:00:00.000+00:00", "generator": { "date": "2024-08-15T17:56:40.873+00:00", "engine": { "name": "BSI-WID", "version": "1.3.5" } }, "id": "WID-SEC-W-2023-1986", "initial_release_date": "2021-04-15T22:00:00.000+00:00", "revision_history": [ { "date": "2021-04-15T22:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" }, { "date": "2021-05-02T22:00:00.000+00:00", "number": "2", "summary": "CVE\u0027s erg\u00e4nzt" }, { "date": "2021-11-08T23:00:00.000+00:00", "number": "3", "summary": "Neue Updates von Siemens aufgenommen" }, { "date": "2023-08-07T22:00:00.000+00:00", "number": "4", "summary": "Neue Updates von Siemens aufgenommen" }, { "date": "2024-02-12T23:00:00.000+00:00", "number": "5", "summary": "Neue Updates von Siemens aufgenommen" } ], "status": "final", "version": "5" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "Microsoft Azure RTOS NetX", "product": { "name": "Microsoft Azure RTOS NetX", "product_id": "T018910", "product_identification_helper": { "cpe": "cpe:/o:microsoft:azure_rtos_netx:-" } } } ], "category": "vendor", "name": "Microsoft" }, { "branches": [ { "category": "product_name", "name": "Siemens Nucleus Net", "product": { "name": "Siemens Nucleus Net", "product_id": "683157", "product_identification_helper": { "cpe": "cpe:/a:siemens:nucleus_net:-" } } }, { "category": "product_name", "name": "Siemens Nucleus RTOS", "product": { "name": "Siemens Nucleus RTOS", "product_id": "683163", "product_identification_helper": { "cpe": "cpe:/o:siemens:nucleus_rtos:-" } } } ], "category": "vendor", "name": "Siemens" }, { "branches": [ { "category": "product_name", "name": "Wind River VxWorks", "product": { "name": "Wind River VxWorks", "product_id": "T018911", "product_identification_helper": { "cpe": "cpe:/o:windriver:vxworks:-" } } } ], "category": "vendor", "name": "Wind River" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-20009", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2016-20009" }, { "cve": "CVE-2020-15795", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2020-15795" }, { "cve": "CVE-2020-27009", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2020-27009" }, { "cve": "CVE-2020-27736", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2020-27736" }, { "cve": "CVE-2020-27737", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2020-27737" }, { "cve": "CVE-2020-27738", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2020-27738" }, { "cve": "CVE-2021-25663", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2021-25663" }, { "cve": "CVE-2021-25664", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2021-25664" }, { "cve": "CVE-2021-25677", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2021-25677" }, { "cve": "CVE-2021-27393", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2021-27393" } ] }
WID-SEC-W-2023-1986
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "hoch" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "Nucleus Net ist der Netzwerk-Stack f\u00fcr das Nucleus RTOS Echtzeitbetriebssystem.\r\nNucleus RTOS ist ein Echtzeitbetriebssystem f\u00fcr Embedded Devices.\r\nAzure RTOS NetX ist ein TCP/IP IPv4 Embedded Network Stack, der f\u00fcr Embedded-, Echtzeit- und IoT-Anwendungen entwickelt wurde. \r\nVxWorks ist ein propriet\u00e4res Echtzeitbetriebssystem, das von Wind River Systems entwickelt wird.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Siemens Nucleus Net, Siemens Nucleus RTOS, Microsoft Azure RTOS NetX und Wind River VxWorks ausnutzen, um beliebigen Programmcode mit Administratorrechten auszuf\u00fchren oder einen Denial of Service zu verursachen.", "title": "Angriff" }, { "category": "general", "text": "- Sonstiges", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-1986 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2021/wid-sec-w-2023-1986.json" }, { "category": "self", "summary": "WID-SEC-2023-1986 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-1986" }, { "category": "external", "summary": "Forescout Report vom 2021-04-15", "url": "https://www.forescout.com/company/resources/namewreck-breaking-and-fixing-dns-implementations/" }, { "category": "external", "summary": "Siemens Security Advisory by Siemens ProductCERT", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf" }, { "category": "external", "summary": "Siemens Security Advisory by Siemens ProductCERT", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf" }, { "category": "external", "summary": "Siemens Security Advisory SSA-180579 vom 2023-08-08", "url": "https://cert-portal.siemens.com/productcert/html/ssa-180579.html" }, { "category": "external", "summary": "Siemens Security Advisory SSA-248289 vom 2024-02-13", "url": "https://cert-portal.siemens.com/productcert/html/ssa-248289.html" } ], "source_lang": "en-US", "title": "NAME:WRECK: Mehrere Schwachstellen in TCP/IP Stacks", "tracking": { "current_release_date": "2024-02-12T23:00:00.000+00:00", "generator": { "date": "2024-08-15T17:56:40.873+00:00", "engine": { "name": "BSI-WID", "version": "1.3.5" } }, "id": "WID-SEC-W-2023-1986", "initial_release_date": "2021-04-15T22:00:00.000+00:00", "revision_history": [ { "date": "2021-04-15T22:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" }, { "date": "2021-05-02T22:00:00.000+00:00", "number": "2", "summary": "CVE\u0027s erg\u00e4nzt" }, { "date": "2021-11-08T23:00:00.000+00:00", "number": "3", "summary": "Neue Updates von Siemens aufgenommen" }, { "date": "2023-08-07T22:00:00.000+00:00", "number": "4", "summary": "Neue Updates von Siemens aufgenommen" }, { "date": "2024-02-12T23:00:00.000+00:00", "number": "5", "summary": "Neue Updates von Siemens aufgenommen" } ], "status": "final", "version": "5" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "Microsoft Azure RTOS NetX", "product": { "name": "Microsoft Azure RTOS NetX", "product_id": "T018910", "product_identification_helper": { "cpe": "cpe:/o:microsoft:azure_rtos_netx:-" } } } ], "category": "vendor", "name": "Microsoft" }, { "branches": [ { "category": "product_name", "name": "Siemens Nucleus Net", "product": { "name": "Siemens Nucleus Net", "product_id": "683157", "product_identification_helper": { "cpe": "cpe:/a:siemens:nucleus_net:-" } } }, { "category": "product_name", "name": "Siemens Nucleus RTOS", "product": { "name": "Siemens Nucleus RTOS", "product_id": "683163", "product_identification_helper": { "cpe": "cpe:/o:siemens:nucleus_rtos:-" } } } ], "category": "vendor", "name": "Siemens" }, { "branches": [ { "category": "product_name", "name": "Wind River VxWorks", "product": { "name": "Wind River VxWorks", "product_id": "T018911", "product_identification_helper": { "cpe": "cpe:/o:windriver:vxworks:-" } } } ], "category": "vendor", "name": "Wind River" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-20009", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2016-20009" }, { "cve": "CVE-2020-15795", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2020-15795" }, { "cve": "CVE-2020-27009", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2020-27009" }, { "cve": "CVE-2020-27736", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2020-27736" }, { "cve": "CVE-2020-27737", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2020-27737" }, { "cve": "CVE-2020-27738", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2020-27738" }, { "cve": "CVE-2021-25663", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2021-25663" }, { "cve": "CVE-2021-25664", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2021-25664" }, { "cve": "CVE-2021-25677", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2021-25677" }, { "cve": "CVE-2021-27393", "notes": [ { "category": "description", "text": "In der DNS-Implementierung in weitgenutzten TCP/IP Stacks bestehen mehrere Schwachstellen, die sich in Server-Anwendungen, aber auch IoT und OT-Devices befinden. Sie basieren gr\u00f6\u00dftenteils auf Fehlern in der Kompressionsfunktion der DNS-Implementierung. Ein entfernter anonymer Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code mit Administratorrechten zur Ausf\u00fchrung zu bringen oder einen Denial of Service zu verursachen." } ], "product_status": { "known_affected": [ "683157", "T018910", "T018911", "683163" ] }, "release_date": "2021-04-15T22:00:00.000+00:00", "title": "CVE-2021-27393" } ] }
var-202103-0365
Vulnerability from variot
A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. Wind River VxWorks Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Wind River VxWorks is an operating system of Wind River Company in the United States. The industry-leading real-time operating system for building embedded devices and systems. Remote attackers can use this vulnerability to submit special requests, causing the application to crash or execute arbitrary code in the application context
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-0365", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sgt-400", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "vxworks", "scope": "lte", "trust": 1.0, "vendor": "windriver", "version": "7.0" }, { "model": "sgt-100", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sgt-300", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sgt-a65", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sgt-a35", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sgt-a20", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sgt-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "vxworks", "scope": "gte", "trust": 1.0, "vendor": "windriver", "version": "6.5" }, { "model": "vxworks", "scope": "eq", "trust": 0.8, "vendor": "\u30a6\u30a4\u30f3\u30c9\u30ea\u30d0\u30fc\u682a\u5f0f\u4f1a\u793e", "version": "6.5 to 7" }, { "model": "vxworks", "scope": "eq", "trust": 0.8, "vendor": "\u30a6\u30a4\u30f3\u30c9\u30ea\u30d0\u30fc\u682a\u5f0f\u4f1a\u793e", "version": null }, { "model": "river vxworks", "scope": "gte", "trust": 0.6, "vendor": "wind", "version": "6.5,\u003c=7" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-29083" }, { "db": "JVNDB", "id": "JVNDB-2016-009699" }, { "db": "NVD", "id": "CVE-2016-20009" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported to CISA that these products are affected by this vulnerability when using some third-party components.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-841" } ], "trust": 0.6 }, "cve": "CVE-2016-20009", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2016-20009", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2021-29083", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2016-20009", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2016-20009", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2016-20009", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2016-20009", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2021-29083", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202103-841", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2016-20009", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-29083" }, { "db": "VULMON", "id": "CVE-2016-20009" }, { "db": "JVNDB", "id": "JVNDB-2016-009699" }, { "db": "CNNVD", "id": "CNNVD-202103-841" }, { "db": "NVD", "id": "CVE-2016-20009" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A DNS client stack-based buffer overflow in ipdnsc_decode_name() affects Wind River VxWorks 6.5 through 7. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. Wind River VxWorks Is vulnerable to an out-of-bounds write.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Wind River VxWorks is an operating system of Wind River Company in the United States. The industry-leading real-time operating system for building embedded devices and systems. Remote attackers can use this vulnerability to submit special requests, causing the application to crash or execute arbitrary code in the application context", "sources": [ { "db": "NVD", "id": "CVE-2016-20009" }, { "db": "JVNDB", "id": "JVNDB-2016-009699" }, { "db": "CNVD", "id": "CNVD-2021-29083" }, { "db": "VULMON", "id": "CVE-2016-20009" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2016-20009", "trust": 3.1 }, { "db": "SIEMENS", "id": "SSA-553445", "trust": 1.7 }, { "db": "JVN", "id": "JVNVU99791395", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2016-009699", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-29083", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-222-06", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.2712", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202103-841", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2016-20009", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-29083" }, { "db": "VULMON", "id": "CVE-2016-20009" }, { "db": "JVNDB", "id": "JVNDB-2016-009699" }, { "db": "CNNVD", "id": "CNNVD-202103-841" }, { "db": "NVD", "id": "CVE-2016-20009" } ] }, "id": "VAR-202103-0365", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-29083" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-29083" } ] }, "last_update_date": "2024-11-23T20:22:24.873000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://www.windriver.com/" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=3f7c93868d7099e31ef639cbd5d52b75" }, { "title": "BleepingComputer", "trust": 0.1, "url": "https://www.bleepingcomputer.com/news/security/name-wreck-dns-vulnerabilities-affect-over-100-million-devices/" } ], "sources": [ { "db": "VULMON", "id": "CVE-2016-20009" }, { "db": "JVNDB", "id": "JVNDB-2016-009699" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2016-009699" }, { "db": "NVD", "id": "CVE-2016-20009" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://blog.exodusintel.com/2016/08/09/vxworks-execute-my-packets/" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu99791395/index.html" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2016-20009" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.2712" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-222-06" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.bleepingcomputer.com/news/security/name-wreck-dns-vulnerabilities-affect-over-100-million-devices/" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-553445.txt" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-29083" }, { "db": "VULMON", "id": "CVE-2016-20009" }, { "db": "JVNDB", "id": "JVNDB-2016-009699" }, { "db": "CNNVD", "id": "CNNVD-202103-841" }, { "db": "NVD", "id": "CVE-2016-20009" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-29083" }, { "db": "VULMON", "id": "CVE-2016-20009" }, { "db": "JVNDB", "id": "JVNDB-2016-009699" }, { "db": "CNNVD", "id": "CNNVD-202103-841" }, { "db": "NVD", "id": "CVE-2016-20009" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-18T00:00:00", "db": "CNVD", "id": "CNVD-2021-29083" }, { "date": "2021-03-11T00:00:00", "db": "VULMON", "id": "CVE-2016-20009" }, { "date": "2021-11-24T00:00:00", "db": "JVNDB", "id": "JVNDB-2016-009699" }, { "date": "2021-03-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-841" }, { "date": "2021-03-11T22:15:12.120000", "db": "NVD", "id": "CVE-2016-20009" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-18T00:00:00", "db": "CNVD", "id": "CNVD-2021-29083" }, { "date": "2021-08-10T00:00:00", "db": "VULMON", "id": "CVE-2016-20009" }, { "date": "2021-11-24T06:53:00", "db": "JVNDB", "id": "JVNDB-2016-009699" }, { "date": "2022-04-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-841" }, { "date": "2024-11-21T02:47:32.740000", "db": "NVD", "id": "CVE-2016-20009" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-841" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Wind\u00a0River\u00a0VxWorks\u00a0 Out-of-bounds Vulnerability in Microsoft", "sources": [ { "db": "JVNDB", "id": "JVNDB-2016-009699" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-841" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.