cve-2015-7937
Vulnerability from cvelistv5
Published
2015-12-21 11:00
Modified
2024-08-06 08:06
Severity ?
EPSS score ?
Summary
Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01 | Vendor Advisory | |
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/79622 | ||
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/79622 | ||
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01 | Third Party Advisory, US Government Resource |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T08:06:30.903Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01" }, { "name": "79622", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/79622" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2015-12-17T00:00:00", "descriptions": [ { "lang": "en", "value": "Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2016-11-25T19:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01" }, { "name": "79622", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/79622" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2015-7937", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01" }, { "name": "79622", "refsource": "BID", "url": "http://www.securityfocus.com/bid/79622" }, { "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01", "refsource": "CONFIRM", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2015-7937", "datePublished": "2015-12-21T11:00:00", "dateReserved": "2015-10-22T00:00:00", "dateUpdated": "2024-08-06T08:06:30.903Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2015-7937\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2015-12-21T11:59:12.097\",\"lastModified\":\"2024-11-21T02:37:41.870\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de buffer basado en pila en GoAhead Web Server en dispositivos Schneider Electric Modicon M340 PLC BMXNOx y BMXPx permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de una contrase\u00f1a larga en los datos de HTTP Basic Authentication.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:bmxnoc0401:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF08654A-FFCB-47D3-AC82-DF7284548962\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:bmxnoe0100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"80FC6FF2-D662-4A57-AAA6-BC04351DC779\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:bmxnoe0100h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C37C1E3E-CA86-4AB5-82A8-BA758F02475D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:bmxnoe0110:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"98F3B055-8919-4E09-9827-288F0A03DAFF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:bmxnoe0110h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1E47DB14-EF4B-4E4E-9DA2-B3F6EFA72BF4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:bmxnor0200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ABF43229-1E2E-493A-B44F-DD2870559A93\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"60D9A366-3394-4275-B884-AE6E7227156E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:bmxpra0100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"87FE8964-ECA5-4F5C-933D-F527BDDA1316\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"99F2F851-C18F-4CB8-B47C-516F2AC7955D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"56BAED8B-EEFA-45D7-A5A3-9B62067CE24C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m340_bmxp342030:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E472ABB0-5556-4B96-9CEF-2180E24FA7FD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"354968F7-C41B-4C21-8E47-81DC07DF0EA5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m340_bmxp3420302h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"075A16D1-F4DF-4DCB-8DF9-152E282CE01F\"}]}]}],\"references\":[{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/79622\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-344-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/79622\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-15-351-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.