GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2014-2342 (GCVE-0-2014-2342)

Vulnerability from cvelistv5 – Published: 2014-05-30 23:00 – Updated: 2025-10-02 22:17
VLAI
Title
Triangle MicroWorks SCADA Data Gateway Resource Exhaustion
Summary
Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service (excessive data processing) via a crafted DNP3 packet.
Severity
No CVSS data available.
CWE
Impacted products
Vendor Product Version CPE status
Triangle MicroWorks SCADA Data Gateway Affected: 0 , < v3.00.0635 (custom)
guessed Create a notification for this product.
Date Public
2014-05-29 06:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T10:14:25.053Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SCADA Data Gateway",
          "vendor": "Triangle MicroWorks",
          "versions": [
            {
              "lessThan": "v3.00.0635",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Adam Crain of Automatak and Chris Sistrunk of Mandiant"
        }
      ],
      "datePublic": "2014-05-29T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eTriangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service (excessive data processing) via a crafted DNP3 packet.\u003c/p\u003e"
            }
          ],
          "value": "Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service (excessive data processing) via a crafted DNP3 packet."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-02T22:17:05.858Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-149-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eTriangle MicroWorks has produced an update and release notes describing the mitigation. Please contact Triangle MicroWorks Support for details on specific platform updates here:\u003c/p\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.trianglemicroworks.com/SupportPage.htm\"\u003ehttp://www.trianglemicroworks.com/SupportPage.htm\u003c/a\u003e\u003c/p\u003e\u003cp\u003eRelease notes are found here:\u003c/p\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new\"\u003ehttp://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new\u003c/a\u003e\u003c/p\u003e\u003cp\u003eTriangle MicroWorks recommends following the International Electrotechnical Commission (IEC) Technical Specification TS 62351 to reduce the risk from vulnerability. More information on recommended implementation practices for Triangle MicroWorks products is available by contacting your product representative.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Triangle MicroWorks has produced an update and release notes describing the mitigation. Please contact Triangle MicroWorks Support for details on specific platform updates here:\n\n http://www.trianglemicroworks.com/SupportPage.htm \n\nRelease notes are found here:\n\n http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new \n\nTriangle MicroWorks recommends following the International Electrotechnical Commission (IEC) Technical Specification TS 62351 to reduce the risk from vulnerability. More information on recommended implementation practices for Triangle MicroWorks products is available by contacting your product representative."
        }
      ],
      "source": {
        "advisory": "ICSA-14-149-01",
        "discovery": "EXTERNAL"
      },
      "title": "Triangle MicroWorks SCADA Data Gateway Resource Exhaustion",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-2342",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service (excessive data processing) via a crafted DNP3 packet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new",
              "refsource": "MISC",
              "url": "http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"
            },
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-2342",
    "datePublished": "2014-05-30T23:00:00.000Z",
    "dateReserved": "2014-03-13T00:00:00.000Z",
    "dateUpdated": "2025-10-02T22:17:05.858Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2014-2342",
      "date": "2026-09-19",
      "epss": "0.01791",
      "percentile": "0.77381"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A505671F-8C57-47A2-89D4-DC6186F5D7DA",
                  "versionEndIncluding": "3.00.0633",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D2626C47-B68A-4A21-B5A2-9D64A28A7120",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50.0309:*:*:*:*:*:*:*",
                  "matchCriteriaId": "69D2B52D-B324-4115-A3BB-51E3BF97758B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.51:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9406C4EC-5758-458D-8354-6736CA78A660",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.53:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EB915370-216E-40DC-AEF5-634230394E00",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0515:*:*:*:*:*:*:*",
                  "matchCriteriaId": "22E5498C-D5F0-43F7-A536-AB65B4DEB49F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0516:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2099DFC5-F241-4C47-9A17-FE40101A4570",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0517:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F1E898A9-7F0E-453C-8509-75E7E1290382",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0518:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E513983A-C6A2-4E07-874B-880F7A013D53",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0528:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D6861F70-5798-4B41-BE94-BECCF16752BB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0529:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1B5722CA-130A-46B3-9A30-9661069890AF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0536:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F5E625A4-30E4-4D5B-81B2-B0B0569948DB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0540:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5A6D03B5-2E8C-49E9-8A18-F367F72A4D50",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0544:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AF59F8E0-C4BA-4658-9B91-BACD59B9C482",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0545:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BD36BB8A-C840-494B-835C-98EB0075CA62",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0552:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8FDB5301-887B-4950-A918-113B75D2BDE5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0553:*:*:*:*:*:*:*",
                  "matchCriteriaId": "76BF9332-5F3E-4230-A742-2019B2DCEB22",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0558:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1610F5AE-3BB1-4BDB-8C88-A2B83DBE39C1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0561:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1E2A4B7A-D8DA-4A1E-8506-A2D377E7568D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0562:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90EA0A71-B4C7-4F54-A439-4B0FA9637410",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0564:*:*:*:*:*:*:*",
                  "matchCriteriaId": "71B02213-096E-4CA2-8528-64E83EA06D27",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0565:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EA1B917-A27E-4043-BD74-534B13916F3B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0566:*:*:*:*:*:*:*",
                  "matchCriteriaId": "378C61EE-9420-42D3-9DA2-71F2D459ACE9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0567:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CA21BE3B-6C2E-4479-A9A0-E3966741B832",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0569:*:*:*:*:*:*:*",
                  "matchCriteriaId": "49C97936-8AF3-41D8-8D6B-F6C9C5F4B002",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0570:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D3175298-E0A4-4571-BDCC-FDA81675BC67",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0571:*:*:*:*:*:*:*",
                  "matchCriteriaId": "18BF8DF0-93D1-4ACA-BA78-B6DE0080AD52",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0572:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E1D5F9B2-38C5-45AC-9A33-80E61BAF0E17",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0573:*:*:*:*:*:*:*",
                  "matchCriteriaId": "00666362-AD62-4942-96E8-C08BF087E34F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0574:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5BC82C89-7D15-452D-8610-23F3952487E9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0575:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3D15DD91-4F01-4B95-8F9A-C4848800BDBB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0576:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9DF57506-CC34-473C-8165-CB26194E80BB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0577:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CC480C77-1950-4C3A-B77E-D2C2AC59FE20",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0578:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2044B8C6-D0C6-4A1E-9798-19912FFAE097",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0579:*:*:*:*:*:*:*",
                  "matchCriteriaId": "40D4B1C5-CE06-4082-9534-513BB99D7D7B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0580:*:*:*:*:*:*:*",
                  "matchCriteriaId": "15E62697-E6BD-4796-9470-F6E125CD3F4C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0581:*:*:*:*:*:*:*",
                  "matchCriteriaId": "299D658E-143A-4556-A6FF-37EDA07828CF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0582:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7619010A-954E-4F5D-8DDB-0ED652E2A306",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0583:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C042A0EB-AB96-4FD2-A19E-4E9101C2C63C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0584:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B8B7B997-4D7F-4A34-822A-3AF52A4FA715",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0586:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3E073D1B-4FBF-4DE2-AA5A-1EE8774D20FD",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0587:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2285B98B-3E80-4C5B-9D7D-DA7C250FBAD0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0588:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0EC58901-067E-485B-9723-9F344F306C39",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0589:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E4583789-CC14-48BB-83B5-AF1B6896B10B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0590:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7CEC3409-0CED-41A8-8718-B0EFCA85DA49",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0591:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4AEB67C-7DAF-44D2-BB32-FD9E86D8EA0A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0592:*:*:*:*:*:*:*",
                  "matchCriteriaId": "383DA8F4-1DDD-43A9-8A53-721F5F449CA2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0594:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1AD95D30-4502-44EB-9C0C-D9A45CD24E5C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0595:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B9F60297-9FA4-47F6-98AF-B9662568D76F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0596:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4E593FD2-7158-40D0-9F44-01C06BF96F06",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0597:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0D8A435F-8C6D-4584-8DB9-4A0C515F6D3B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0598:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5F210B77-F989-4931-AFBF-CEC2A175FC27",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0599:*:*:*:*:*:*:*",
                  "matchCriteriaId": "36BBE6AE-BEE1-441B-A5A4-30BD7FCFBF3B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F74C4546-500F-405C-B585-6F6C07065808",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0612:*:*:*:*:*:*:*",
                  "matchCriteriaId": "948521F4-CA30-4269-8A98-96F9AD004150",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0615:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9D9853CB-38CC-419D-A9F8-EDDA2F6CE4F8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0616:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7C679459-44C7-454C-9894-87ABE1F710F2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0630:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CD169173-9189-42BE-A741-955889E44FC9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service (excessive data processing) via a crafted DNP3 packet."
        },
        {
          "lang": "es",
          "value": "Triangle MicroWorks SCADA Data Gateway anterior a 3.00.0635 permite a atacantes remotos causar una denegaci\u00f3n de servicio (procesamiento de datos excesivo) a trav\u00e9s de una paquete DNP3 manipulado."
        }
      ],
      "id": "CVE-2014-2342",
      "lastModified": "2024-11-21T02:06:07.160",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ]
      },
      "published": "2014-05-30T23:55:02.707",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "US Government Resource"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "url": "http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "US Government Resource"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A505671F-8C57-47A2-89D4-DC6186F5D7DA",
                    "versionEndIncluding": "3.00.0633",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D2626C47-B68A-4A21-B5A2-9D64A28A7120",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50.0309:*:*:*:*:*:*:*",
                    "matchCriteriaId": "69D2B52D-B324-4115-A3BB-51E3BF97758B",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.51:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9406C4EC-5758-458D-8354-6736CA78A660",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.53:*:*:*:*:*:*:*",
                    "matchCriteriaId": "EB915370-216E-40DC-AEF5-634230394E00",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0515:*:*:*:*:*:*:*",
                    "matchCriteriaId": "22E5498C-D5F0-43F7-A536-AB65B4DEB49F",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0516:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2099DFC5-F241-4C47-9A17-FE40101A4570",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0517:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F1E898A9-7F0E-453C-8509-75E7E1290382",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0518:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E513983A-C6A2-4E07-874B-880F7A013D53",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0528:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D6861F70-5798-4B41-BE94-BECCF16752BB",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0529:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1B5722CA-130A-46B3-9A30-9661069890AF",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0536:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F5E625A4-30E4-4D5B-81B2-B0B0569948DB",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0540:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5A6D03B5-2E8C-49E9-8A18-F367F72A4D50",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0544:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AF59F8E0-C4BA-4658-9B91-BACD59B9C482",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0545:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BD36BB8A-C840-494B-835C-98EB0075CA62",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0552:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8FDB5301-887B-4950-A918-113B75D2BDE5",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0553:*:*:*:*:*:*:*",
                    "matchCriteriaId": "76BF9332-5F3E-4230-A742-2019B2DCEB22",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0558:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1610F5AE-3BB1-4BDB-8C88-A2B83DBE39C1",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0561:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1E2A4B7A-D8DA-4A1E-8506-A2D377E7568D",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0562:*:*:*:*:*:*:*",
                    "matchCriteriaId": "90EA0A71-B4C7-4F54-A439-4B0FA9637410",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0564:*:*:*:*:*:*:*",
                    "matchCriteriaId": "71B02213-096E-4CA2-8528-64E83EA06D27",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0565:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8EA1B917-A27E-4043-BD74-534B13916F3B",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0566:*:*:*:*:*:*:*",
                    "matchCriteriaId": "378C61EE-9420-42D3-9DA2-71F2D459ACE9",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0567:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CA21BE3B-6C2E-4479-A9A0-E3966741B832",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0569:*:*:*:*:*:*:*",
                    "matchCriteriaId": "49C97936-8AF3-41D8-8D6B-F6C9C5F4B002",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0570:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D3175298-E0A4-4571-BDCC-FDA81675BC67",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0571:*:*:*:*:*:*:*",
                    "matchCriteriaId": "18BF8DF0-93D1-4ACA-BA78-B6DE0080AD52",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0572:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E1D5F9B2-38C5-45AC-9A33-80E61BAF0E17",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0573:*:*:*:*:*:*:*",
                    "matchCriteriaId": "00666362-AD62-4942-96E8-C08BF087E34F",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0574:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5BC82C89-7D15-452D-8610-23F3952487E9",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0575:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3D15DD91-4F01-4B95-8F9A-C4848800BDBB",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0576:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9DF57506-CC34-473C-8165-CB26194E80BB",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0577:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CC480C77-1950-4C3A-B77E-D2C2AC59FE20",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0578:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2044B8C6-D0C6-4A1E-9798-19912FFAE097",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0579:*:*:*:*:*:*:*",
                    "matchCriteriaId": "40D4B1C5-CE06-4082-9534-513BB99D7D7B",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0580:*:*:*:*:*:*:*",
                    "matchCriteriaId": "15E62697-E6BD-4796-9470-F6E125CD3F4C",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0581:*:*:*:*:*:*:*",
                    "matchCriteriaId": "299D658E-143A-4556-A6FF-37EDA07828CF",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0582:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7619010A-954E-4F5D-8DDB-0ED652E2A306",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0583:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C042A0EB-AB96-4FD2-A19E-4E9101C2C63C",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0584:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B8B7B997-4D7F-4A34-822A-3AF52A4FA715",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0586:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3E073D1B-4FBF-4DE2-AA5A-1EE8774D20FD",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0587:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2285B98B-3E80-4C5B-9D7D-DA7C250FBAD0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0588:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0EC58901-067E-485B-9723-9F344F306C39",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0589:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E4583789-CC14-48BB-83B5-AF1B6896B10B",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0590:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7CEC3409-0CED-41A8-8718-B0EFCA85DA49",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0591:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B4AEB67C-7DAF-44D2-BB32-FD9E86D8EA0A",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0592:*:*:*:*:*:*:*",
                    "matchCriteriaId": "383DA8F4-1DDD-43A9-8A53-721F5F449CA2",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0594:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1AD95D30-4502-44EB-9C0C-D9A45CD24E5C",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0595:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B9F60297-9FA4-47F6-98AF-B9662568D76F",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0596:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4E593FD2-7158-40D0-9F44-01C06BF96F06",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0597:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0D8A435F-8C6D-4584-8DB9-4A0C515F6D3B",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0598:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5F210B77-F989-4931-AFBF-CEC2A175FC27",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0599:*:*:*:*:*:*:*",
                    "matchCriteriaId": "36BBE6AE-BEE1-441B-A5A4-30BD7FCFBF3B",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F74C4546-500F-405C-B585-6F6C07065808",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0612:*:*:*:*:*:*:*",
                    "matchCriteriaId": "948521F4-CA30-4269-8A98-96F9AD004150",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0615:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9D9853CB-38CC-419D-A9F8-EDDA2F6CE4F8",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0616:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7C679459-44C7-454C-9894-87ABE1F710F2",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0630:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CD169173-9189-42BE-A741-955889E44FC9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service (excessive data processing) via a crafted DNP3 packet."
          },
          {
            "lang": "es",
            "value": "Triangle MicroWorks SCADA Data Gateway anterior a 3.00.0635 permite a atacantes remotos causar una denegaci\u00f3n de servicio (procesamiento de datos excesivo) a trav\u00e9s de una paquete DNP3 manipulado."
          }
        ],
        "id": "CVE-2014-2342",
        "lastModified": "2026-05-06T22:30:45.220",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.3,
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 8.6,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary",
              "userInteractionRequired": false
            },
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ]
        },
        "published": "2014-05-30T23:55:02.707",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "url": "http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-149-01"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "US Government Resource"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-400"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-20"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…