CNVD-2026-27436
Vulnerability from cnvd - Published: 2026-07-14
VLAI
Title
Delta Electronics DVP12SE授权问题漏洞
Description
Delta Electronics DVP12SE是一个可编程逻辑控制器模块。
Delta Electronics DVP12SE存在授权问题漏洞,该漏洞源于通过指定端口暴露Modbus TCP服务且未设置身份验证或访问控制,攻击者可利用该漏洞与安全敏感的PLC功能进行交互。
Severity
高
Formal description
厂商尚未提供漏洞修复方案,请关注厂商主页更新: https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00011_DVP12SE%20Multiple%20Vulnerabilities%20(CVE-2026-12818,%20CVE-2026-12819)_v1.0.pdf
Reference
https://nvd.nist.gov/vuln/detail/CVE-2026-12819
Impacted products
| Name | Delta Electronics DVP-12SE |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2026-12819",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2026-12819"
}
},
"description": "Delta Electronics DVP12SE\u662f\u4e00\u4e2a\u53ef\u7f16\u7a0b\u903b\u8f91\u63a7\u5236\u5668\u6a21\u5757\u3002\n\nDelta Electronics DVP12SE\u5b58\u5728\u6388\u6743\u95ee\u9898\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u901a\u8fc7\u6307\u5b9a\u7aef\u53e3\u66b4\u9732Modbus TCP\u670d\u52a1\u4e14\u672a\u8bbe\u7f6e\u8eab\u4efd\u9a8c\u8bc1\u6216\u8bbf\u95ee\u63a7\u5236\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u4e0e\u5b89\u5168\u654f\u611f\u7684PLC\u529f\u80fd\u8fdb\u884c\u4ea4\u4e92\u3002",
"formalWay": "\u5382\u5546\u5c1a\u672a\u63d0\u4f9b\u6f0f\u6d1e\u4fee\u590d\u65b9\u6848\uff0c\u8bf7\u5173\u6ce8\u5382\u5546\u4e3b\u9875\u66f4\u65b0\uff1a\r\nhttps://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00011_DVP12SE%20Multiple%20Vulnerabilities%20(CVE-2026-12818,%20CVE-2026-12819)_v1.0.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2026-27436",
"openTime": "2026-07-14",
"products": {
"product": "Delta Electronics DVP-12SE"
},
"referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2026-12819",
"serverity": "\u9ad8",
"submitTime": "2026-07-08",
"title": "Delta Electronics DVP12SE\u6388\u6743\u95ee\u9898\u6f0f\u6d1e"
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
Loading…
Loading…