CVE-2026-42806 (GCVE-0-2026-42806)
Vulnerability from cvelistv5 – Published: 2026-09-10 09:04 – Updated: 2026-09-10 15:00
VLAI
EPSS
VEX
Summary
An out-of-bounds read vulnerability was discovered in the Bosch BME690 SensorAPI (C-driver) in version v1.0.3 and prior, specifically within the field data parsing logic in read_all_field_data (bme69x.c).
The driver prefetches heater configuration registers into a contiguous 30-byte stack buffer (set_val) mapping IDAC, RES_HEAT, and GAS_WAIT tables.
When parsing sensor field data, the gas_index is extracted using a 4-bit mask (0..15) but lacks boundary verification against the valid range (0..9).
An attacker or a compromised peripheral mimicking a sensor on the I2C/SPI bus could return a payload with a gas index value of 10 or higher.
This causes the driver to perform an out-of-bounds array access (set_val[20 + gas_index]), reading up to 6 bytes past the stack buffer.
The leaked out-of-bounds byte is then written into the public gas_wait field, which may lead to measurement corruption or leak adjacent stack memory when telemetered or logged.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 15:00 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Bosch Sensortec | BME690 SensorAPI (C) |
Affected:
1.0.1 , ≤ 1.0.3
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-42806",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T15:00:33.822497Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T15:00:50.874Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BME690 SensorAPI (C)",
"vendor": "Bosch Sensortec",
"versions": [
{
"lessThanOrEqual": "1.0.3",
"status": "affected",
"version": "1.0.1",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An out-of-bounds read vulnerability was discovered in the Bosch BME690 SensorAPI (C-driver) in version v1.0.3 and prior, specifically within the field data parsing logic in read_all_field_data (bme69x.c).\r\n\r\nThe driver prefetches heater configuration registers into a contiguous 30-byte stack buffer (set_val) mapping IDAC, RES_HEAT, and GAS_WAIT tables.\r\n\r\nWhen parsing sensor field data, the gas_index is extracted using a 4-bit mask (0..15) but lacks boundary verification against the valid range (0..9).\r\n\r\nAn attacker or a compromised peripheral mimicking a sensor on the I2C/SPI bus could return a payload with a gas index value of 10 or higher.\r\n\r\nThis causes the driver to perform an out-of-bounds array access (set_val[20 + gas_index]), reading up to 6 bytes past the stack buffer.\r\n\r\nThe leaked out-of-bounds byte is then written into the public gas_wait field, which may lead to measurement corruption or leak adjacent stack memory when telemetered or logged."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "LOW",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T09:04:44.607Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2026-42806",
"datePublished": "2026-09-10T09:04:44.607Z",
"dateReserved": "2026-04-30T08:03:11.875Z",
"dateUpdated": "2026-09-10T15:00:50.874Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-42806",
"date": "2026-09-10",
"epss": "0.00154",
"percentile": "0.04801"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2026-42806\",\"sourceIdentifier\":\"psirt@bosch.com\",\"published\":\"2026-09-10T09:17:02.127\",\"lastModified\":\"2026-09-10T09:17:02.127\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An out-of-bounds read vulnerability was discovered in the Bosch BME690 SensorAPI (C-driver) in version v1.0.3 and prior, specifically within the field data parsing logic in read_all_field_data (bme69x.c).\\r\\n\\r\\nThe driver prefetches heater configuration registers into a contiguous 30-byte stack buffer (set_val) mapping IDAC, RES_HEAT, and GAS_WAIT tables.\\r\\n\\r\\nWhen parsing sensor field data, the gas_index is extracted using a 4-bit mask (0..15) but lacks boundary verification against the valid range (0..9).\\r\\n\\r\\nAn attacker or a compromised peripheral mimicking a sensor on the I2C/SPI bus could return a payload with a gas index value of 10 or higher.\\r\\n\\r\\nThis causes the driver to perform an out-of-bounds array access (set_val[20 + gas_index]), reading up to 6 bytes past the stack buffer.\\r\\n\\r\\nThe leaked out-of-bounds byte is then written into the public gas_wait field, which may lead to measurement corruption or leak adjacent stack memory when telemetered or logged.\"}],\"affected\":[{\"source\":\"psirt@bosch.com\",\"affectedData\":[{\"vendor\":\"Bosch Sensortec\",\"product\":\"BME690 SensorAPI (C)\",\"versions\":[{\"version\":\"1.0.1\",\"lessThanOrEqual\":\"1.0.3\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":0.9,\"impactScore\":3.4}]},\"weaknesses\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"references\":[{\"url\":\"https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html\",\"source\":\"psirt@bosch.com\"}]}}",
"vulnrichment": {
"containers": "{\"cna\": {\"providerMetadata\": {\"orgId\": \"c95f66b2-7e7c-41c5-8f09-6f86ec68659c\", \"shortName\": \"bosch\", \"dateUpdated\": \"2026-09-10T09:04:44.607Z\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An out-of-bounds read vulnerability was discovered in the Bosch BME690 SensorAPI (C-driver) in version v1.0.3 and prior, specifically within the field data parsing logic in read_all_field_data (bme69x.c).\\r\\n\\r\\nThe driver prefetches heater configuration registers into a contiguous 30-byte stack buffer (set_val) mapping IDAC, RES_HEAT, and GAS_WAIT tables.\\r\\n\\r\\nWhen parsing sensor field data, the gas_index is extracted using a 4-bit mask (0..15) but lacks boundary verification against the valid range (0..9).\\r\\n\\r\\nAn attacker or a compromised peripheral mimicking a sensor on the I2C/SPI bus could return a payload with a gas index value of 10 or higher.\\r\\n\\r\\nThis causes the driver to perform an out-of-bounds array access (set_val[20 + gas_index]), reading up to 6 bytes past the stack buffer.\\r\\n\\r\\nThe leaked out-of-bounds byte is then written into the public gas_wait field, which may lead to measurement corruption or leak adjacent stack memory when telemetered or logged.\"}], \"affected\": [{\"vendor\": \"Bosch Sensortec\", \"product\": \"BME690 SensorAPI (C)\", \"versions\": [{\"version\": \"1.0.1\", \"status\": \"affected\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.0.3\"}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en-US\", \"description\": \"CWE-125 Out-of-bounds Read\", \"cweId\": \"CWE-125\"}]}], \"references\": [{\"url\": \"https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html\", \"name\": \"https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html\", \"tags\": [\"vendor-advisory\"]}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\", \"attackVector\": \"PHYSICAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"LOW\", \"baseScore\": 4.3, \"baseSeverity\": \"MEDIUM\"}}]}, \"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-42806\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-09-10T15:00:33.822497Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-09-10T15:00:43.115Z\"}}]}",
"cveMetadata": "{\"cveId\": \"CVE-2026-42806\", \"assignerOrgId\": \"c95f66b2-7e7c-41c5-8f09-6f86ec68659c\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"bosch\", \"dateReserved\": \"2026-04-30T08:03:11.875Z\", \"datePublished\": \"2026-09-10T09:04:44.607Z\", \"dateUpdated\": \"2026-09-10T15:00:50.874Z\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Loading…
Loading…