CVE-2026-3807 (GCVE-0-2026-3807)

Vulnerability from cvelistv5 – Published: 2026-03-09 06:32 – Updated: 2026-03-10 15:44
VLAI
Title
Tenda FH1202 AdvSetWrlsafeset formWrlsafeset stack-based overflow
Summary
A security vulnerability has been detected in Tenda FH1202 1.2.0.14(408). Impacted is the function formWrlsafeset of the file /goform/AdvSetWrlsafeset. Such manipulation of the argument mit_ssid/mit_ssid_index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-03-10 15:44 UTC
CWE
References
URL Tags
https://vuldb.com/?id.349773 vdb-entrytechnical-description
https://vuldb.com/?ctiid.349773 signaturepermissions-required
https://vuldb.com/?submit.769019 third-party-advisory
https://vuldb.com/?submit.769020 third-party-advisory
https://github.com/Svigo-o/Tenda_vul/tree/main/te… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version CPE status
Tenda FH1202 Affected: 1.2.0.14(408)
    cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-3807",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T15:44:02.273541Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-10T15:44:51.033Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
          ],
          "product": "FH1202",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.0.14(408)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Fan95 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda FH1202 1.2.0.14(408). Impacted is the function formWrlsafeset of the file /goform/AdvSetWrlsafeset. Such manipulation of the argument mit_ssid/mit_ssid_index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-09T06:32:08.531Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-349773 | Tenda FH1202 AdvSetWrlsafeset formWrlsafeset stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.349773"
        },
        {
          "name": "VDB-349773 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.349773"
        },
        {
          "name": "Submit #769019 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.769019"
        },
        {
          "name": "Submit #769020 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.769020"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-advsetwrlsafeset-mit-ssid-buffer-overflow"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-03-08T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-03-08T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-03-08T17:28:02.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda FH1202 AdvSetWrlsafeset formWrlsafeset stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-3807",
    "datePublished": "2026-03-09T06:32:08.531Z",
    "dateReserved": "2026-03-08T16:22:36.756Z",
    "dateUpdated": "2026-03-10T15:44:51.033Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-3807",
      "date": "2026-09-30",
      "epss": "0.01013",
      "percentile": "0.6185"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
                ],
                "product": "FH1202",
                "vendor": "Tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.2.0.14(408)"
                  }
                ]
              }
            ],
            "source": "cna@vuldb.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*",
                    "matchCriteriaId": "B9FD9D0A-39F4-4AD8-AEE0-71C9E77D2799",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4A632A11-60A0-457C-A039-BED32F83BD52",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A security vulnerability has been detected in Tenda FH1202 1.2.0.14(408). Impacted is the function formWrlsafeset of the file /goform/AdvSetWrlsafeset. Such manipulation of the argument mit_ssid/mit_ssid_index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
          },
          {
            "lang": "es",
            "value": "Una vulnerabilidad de seguridad ha sido detectada en Tenda FH1202 1.2.0.14(408). Afectada es la funci\u00f3n formWrlsafeset del archivo /goform/AdvSetWrlsafeset. Tal manipulaci\u00f3n del argumento mit_ssid/mit_ssid_index conduce a un desbordamiento de b\u00fafer basado en pila. El ataque puede ser lanzado remotamente. El exploit ha sido divulgado p\u00fablicamente y puede ser utilizado."
          }
        ],
        "id": "CVE-2026-3807",
        "lastModified": "2026-06-17T10:44:16.097",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "PROOF_OF_CONCEPT",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-3807",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T15:44:02.273541Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-03-09T07:16:04.147",
        "references": [
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-advsetwrlsafeset-mit-ssid-buffer-overflow"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Permissions Required",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?ctiid.349773"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?id.349773"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?submit.769019"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?submit.769020"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Product"
            ],
            "url": "https://www.tenda.com.cn/"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              },
              {
                "lang": "en",
                "value": "CWE-121"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T07:35:05+00:00",
      "cve": "CVE-2026-3807",
      "id": "CVE-2026-3807",
      "initial_release_date": "2026-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Tenda FH1202 AdvSetWrlsafeset formWrlsafeset stack-based overflow",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-3807.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-3807",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-10T15:44:02.273541Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-10T15:44:46.767Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:fh1202_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "FH1202",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.0.14(408)"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Fan95 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in Tenda FH1202 1.2.0.14(408). Impacted is the function formWrlsafeset of the file /goform/AdvSetWrlsafeset. Such manipulation of the argument mit_ssid/mit_ssid_index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-09T06:32:08.531Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-349773 | Tenda FH1202 AdvSetWrlsafeset formWrlsafeset stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.349773"
            },
            {
              "name": "VDB-349773 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.349773"
            },
            {
              "name": "Submit #769019 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.769019"
            },
            {
              "name": "Submit #769020 | Tenda FH1202 V1.2.0.14(408) Buffer Overflow (Duplicate)",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.769020"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Svigo-o/Tenda_vul/tree/main/tenda-fh1202-advsetwrlsafeset-mit-ssid-buffer-overflow"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-03-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-03-08T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-03-08T17:28:02.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda FH1202 AdvSetWrlsafeset formWrlsafeset stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-3807",
        "datePublished": "2026-03-09T06:32:08.531Z",
        "dateReserved": "2026-03-08T16:22:36.756Z",
        "dateUpdated": "2026-03-10T15:44:51.033Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…