CVE-2026-16437 (GCVE-0-2026-16437)

Vulnerability from cvelistv5 – Published: 2026-10-15 08:30 – Updated: 2026-10-16 05:41
VLAI
Title
An authentication bypass vulnerability in GENESIS, GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, MobileHMI, IoTWorX, MC Works64, GENESIS32 and BizViz
Summary
Weak Password Recovery Mechanism for Forgotten Password vulnerability in Mitsubishi Electric GENESIS versions 11.03 and prior, GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, IoTWorX 10.97.3 and prior, MC Works64 all versions, GENESIS32 all versions, BizViz all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.03 and prior, GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, IoTWorX 10.97.3 and prior, GENESIS32 all versions, and BizViz all versions allows an authenticated local user with administrative privileges to unlock the system by tampering with the management file that stores the challenge response. Administrators are able to read and write the management file. But the management file is protected by Windows. As a result, the attacker may disclose, tamper with, destroy, or delete internal information, or cause the affected system to enter a denial-of-service (DoS) condition.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-15 14:08 UTC
CWE
  • CWE-640 - Weak Password Recovery Mechanism for Forgotten Password
Assigner
Mitsubishi CNA under the jpcert root
CNA scorecard – unranked: 8 records in the last 180 days, 10 needed details
References
Impacted products
Vendor Product Version CPE status
Mitsubishi Electric Corporation GENESIS Affected: versions 11.03 and prior
guessed Create a notification for this product.
Mitsubishi Electric Iconics Digital Solutions GENESIS Affected: versions 11.03 and prior
guessed Create a notification for this product.
Mitsubishi Electric Corporation GENESIS64 Affected: versions 10.97.3 and prior
guessed Create a notification for this product.
Mitsubishi Electric Iconics Digital Solutions GENESIS64 Affected: versions 10.97.3 and prior
guessed Create a notification for this product.
Mitsubishi Electric Corporation ICONICS Suite Affected: versions 10.97.3 and prior
guessed Create a notification for this product.
Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Affected: versions 10.97.3 and prior
guessed Create a notification for this product.
Mitsubishi Electric Corporation Hyper Historian Affected: versions 10.97.3 and prior
guessed Create a notification for this product.
Mitsubishi Electric Iconics Digital Solutions Hyper Historian Affected: versions 10.97.3 and prior
guessed Create a notification for this product.
Mitsubishi Electric Corporation AnalytiX Affected: versions 10.97.3 and prior
guessed Create a notification for this product.
Mitsubishi Electric Iconics Digital Solutions AnalytiX Affected: versions 10.97.3 and prior
guessed Create a notification for this product.
Mitsubishi Electric Corporation MobileHMI Affected: versions 10.97.3 and prior
guessed Create a notification for this product.
Mitsubishi Electric Iconics Digital Solutions MobileHMI Affected: versions 10.97.3 and prior
guessed Create a notification for this product.
Mitsubishi Electric Corporation IoTWorX Affected: versions 10.97.3 and prior
guessed Create a notification for this product.
Mitsubishi Electric Iconics Digital Solutions IoTWorX Affected: versions 10.97.3 and prior
guessed Create a notification for this product.
Mitsubishi Electric Corporation MC Works64 Affected: all versions
guessed Create a notification for this product.
Mitsubishi Electric Corporation GENESIS32 Affected: all versions
guessed Create a notification for this product.
Mitsubishi Electric Iconics Digital Solutions GENESIS32 Affected: all versions
guessed Create a notification for this product.
Mitsubishi Electric Corporation BizViz Affected: all versions
guessed Create a notification for this product.
Mitsubishi Electric Iconics Digital Solutions BizViz Affected: all versions
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-16437",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-15T14:08:40.898900Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-15T14:08:54.750Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GENESIS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 11.03 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GENESIS",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 11.03 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GENESIS64",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GENESIS64",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICONICS Suite",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICONICS Suite",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Hyper Historian",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Hyper Historian",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AnalytiX",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AnalytiX",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MobileHMI",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MobileHMI",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "IoTWorX",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "IoTWorX",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MC Works64",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GENESIS32",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GENESIS32",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "BizViz",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "BizViz",
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Weak Password Recovery Mechanism for Forgotten Password vulnerability in Mitsubishi Electric GENESIS versions 11.03 and prior, GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, IoTWorX 10.97.3 and prior, MC Works64 all versions, GENESIS32 all versions, BizViz all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.03 and prior, GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, IoTWorX 10.97.3 and prior, GENESIS32 all versions, and BizViz all versions allows an authenticated local user with administrative privileges to unlock the system by tampering with the management file that stores the challenge response. Administrators are able to read and write the management file. But the management file is protected by Windows. As a result, the attacker may disclose, tamper with, destroy, or delete internal information, or cause the affected system to enter a denial-of-service (DoS) condition."
            }
          ],
          "value": "Weak Password Recovery Mechanism for Forgotten Password vulnerability in Mitsubishi Electric GENESIS versions 11.03 and prior, GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, IoTWorX 10.97.3 and prior, MC Works64 all versions, GENESIS32 all versions, BizViz all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.03 and prior, GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, IoTWorX 10.97.3 and prior, GENESIS32 all versions, and BizViz all versions allows an authenticated local user with administrative privileges to unlock the system by tampering with the management file that stores the challenge response. Administrators are able to read and write the management file. But the management file is protected by Windows. As a result, the attacker may disclose, tamper with, destroy, or delete internal information, or cause the affected system to enter a denial-of-service (DoS) condition."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Information disclosure, Information tampering, and Denial-of-Service(DoS)"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-640",
              "description": "CWE-640 Weak Password Recovery Mechanism for Forgotten Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-10-16T05:41:07.264Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-006_en.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "An authentication bypass vulnerability in GENESIS, GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, MobileHMI, IoTWorX, MC Works64, GENESIS32 and BizViz",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2026-16437",
    "datePublished": "2026-10-15T08:30:39.094Z",
    "dateReserved": "2026-07-21T04:30:29.800Z",
    "dateUpdated": "2026-10-16T05:41:07.264Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-16437",
      "date": "2026-10-15",
      "epss": "0.00093",
      "percentile": "0.00509"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "GENESIS",
                "vendor": "Mitsubishi Electric Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 11.03 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "GENESIS",
                "vendor": "Mitsubishi Electric Iconics Digital Solutions",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 11.03 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "GENESIS64",
                "vendor": "Mitsubishi Electric Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 10.97.3 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "GENESIS64",
                "vendor": "Mitsubishi Electric Iconics Digital Solutions",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 10.97.3 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "ICONICS Suite",
                "vendor": "Mitsubishi Electric Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 10.97.3 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "ICONICS Suite",
                "vendor": "Mitsubishi Electric Iconics Digital Solutions",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 10.97.3 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Hyper Historian",
                "vendor": "Mitsubishi Electric Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 10.97.3 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Hyper Historian",
                "vendor": "Mitsubishi Electric Iconics Digital Solutions",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 10.97.3 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "AnalytiX",
                "vendor": "Mitsubishi Electric Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 10.97.3 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "AnalytiX",
                "vendor": "Mitsubishi Electric Iconics Digital Solutions",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 10.97.3 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "MobileHMI",
                "vendor": "Mitsubishi Electric Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 10.97.3 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "MobileHMI",
                "vendor": "Mitsubishi Electric Iconics Digital Solutions",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 10.97.3 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "IoTWorX",
                "vendor": "Mitsubishi Electric Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 10.97.3 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "IoTWorX",
                "vendor": "Mitsubishi Electric Iconics Digital Solutions",
                "versions": [
                  {
                    "status": "affected",
                    "version": "versions 10.97.3 and prior"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "MC Works64",
                "vendor": "Mitsubishi Electric Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "all versions"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "GENESIS32",
                "vendor": "Mitsubishi Electric Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "all versions"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "GENESIS32",
                "vendor": "Mitsubishi Electric Iconics Digital Solutions",
                "versions": [
                  {
                    "status": "affected",
                    "version": "all versions"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "BizViz",
                "vendor": "Mitsubishi Electric Corporation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "all versions"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "BizViz",
                "vendor": "Mitsubishi Electric Iconics Digital Solutions",
                "versions": [
                  {
                    "status": "affected",
                    "version": "all versions"
                  }
                ]
              }
            ],
            "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Weak Password Recovery Mechanism for Forgotten Password vulnerability in Mitsubishi Electric GENESIS versions 11.03 and prior, GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, IoTWorX 10.97.3 and prior, MC Works64 all versions, GENESIS32 all versions, BizViz all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.03 and prior, GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, IoTWorX 10.97.3 and prior, GENESIS32 all versions, and BizViz all versions allows an authenticated local user with administrative privileges to unlock the system by tampering with the management file that stores the challenge response. Administrators are able to read and write the management file. But the management file is protected by Windows. As a result, the attacker may disclose, tamper with, destroy, or delete internal information, or cause the affected system to enter a denial-of-service (DoS) condition."
          }
        ],
        "id": "CVE-2026-16437",
        "lastModified": "2026-10-16T06:17:10.823",
        "metrics": {
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-16437",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-10-15T14:08:40.898900Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-10-15T09:17:16.910",
        "references": [
          {
            "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
            "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-006_en.pdf"
          }
        ],
        "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "vulnStatus": "Awaiting Analysis",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-640"
              }
            ],
            "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-16437",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T14:08:40.898900Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T14:08:48.544Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 11.03 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 11.03 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS64",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ICONICS Suite",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Hyper Historian",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AnalytiX",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AnalytiX",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MobileHMI",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MobileHMI",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "IoTWorX",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "IoTWorX",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions 10.97.3 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "MC Works64",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GENESIS32",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "BizViz",
              "vendor": "Mitsubishi Electric Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "BizViz",
              "vendor": "Mitsubishi Electric Iconics Digital Solutions",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Weak Password Recovery Mechanism for Forgotten Password vulnerability in Mitsubishi Electric GENESIS versions 11.03 and prior, GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, IoTWorX 10.97.3 and prior, MC Works64 all versions, GENESIS32 all versions, BizViz all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.03 and prior, GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, IoTWorX 10.97.3 and prior, GENESIS32 all versions, and BizViz all versions allows an authenticated local user with administrative privileges to unlock the system by tampering with the management file that stores the challenge response. Administrators are able to read and write the management file. But the management file is protected by Windows. As a result, the attacker may disclose, tamper with, destroy, or delete internal information, or cause the affected system to enter a denial-of-service (DoS) condition."
                }
              ],
              "value": "Weak Password Recovery Mechanism for Forgotten Password vulnerability in Mitsubishi Electric GENESIS versions 11.03 and prior, GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, IoTWorX 10.97.3 and prior, MC Works64 all versions, GENESIS32 all versions, BizViz all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.03 and prior, GENESIS64 versions 10.97.3 and prior, ICONICS Suite versions 10.97.3 and prior, Hyper Historian versions 10.97.3 and prior, AnalytiX versions 10.97.3 and prior, MobileHMI 10.97.3 and prior, IoTWorX 10.97.3 and prior, GENESIS32 all versions, and BizViz all versions allows an authenticated local user with administrative privileges to unlock the system by tampering with the management file that stores the challenge response. Administrators are able to read and write the management file. But the management file is protected by Windows. As a result, the attacker may disclose, tamper with, destroy, or delete internal information, or cause the affected system to enter a denial-of-service (DoS) condition."
            }
          ],
          "impacts": [
            {
              "descriptions": [
                {
                  "lang": "en",
                  "value": "Information disclosure, Information tampering, and Denial-of-Service(DoS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-640",
                  "description": "CWE-640 Weak Password Recovery Mechanism for Forgotten Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-16T05:41:07.264Z",
            "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
            "shortName": "Mitsubishi"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-006_en.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "An authentication bypass vulnerability in GENESIS, GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, MobileHMI, IoTWorX, MC Works64, GENESIS32 and BizViz",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "assignerShortName": "Mitsubishi",
        "cveId": "CVE-2026-16437",
        "datePublished": "2026-10-15T08:30:39.094Z",
        "dateReserved": "2026-07-21T04:30:29.800Z",
        "dateUpdated": "2026-10-16T05:41:07.264Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.