CVE-2025-3705 (GCVE-0-2025-3705)
Vulnerability from cvelistv5
Published
2025-07-07 09:20
Modified
2025-07-07 17:34
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command ('OS Command Injection') when loading a config file from a USB drive.
References
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3705",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-07T17:33:44.109898Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-07T17:34:15.583Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FDS102",
"vendor": "Frauscher",
"versions": [
{
"lessThan": "v2.13.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FDS101",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "v1.4.25",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FDS-SNMP101",
"vendor": "Frauscher",
"versions": [
{
"lessThanOrEqual": "v.2.3.9",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive."
}
],
"value": "A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-07T09:20:03.263Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-030"
}
],
"source": {
"advisory": "VDE-2025-030",
"defect": [
"CERT@VDE#641766"
],
"discovery": "UNKNOWN"
},
"title": "OS Command Injection via USB Config Load",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-3705",
"datePublished": "2025-07-07T09:20:03.263Z",
"dateReserved": "2025-04-16T06:43:57.178Z",
"dateUpdated": "2025-07-07T17:34:15.583Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-3705\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2025-07-07T10:15:28.133\",\"lastModified\":\"2025-07-08T16:18:34.923\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive.\"},{\"lang\":\"es\",\"value\":\"Un atacante f\u00edsico sin privilegios puede obtener control total del dispositivo afectado debido a la neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando del sistema operativo (\u0027Inyecci\u00f3n de comando del sistema operativo\u0027) al cargar un archivo de configuraci\u00f3n desde una unidad USB.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://certvde.com/en/advisories/VDE-2025-030\",\"source\":\"info@cert.vde.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-3705\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-07-07T17:33:44.109898Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-07-07T17:34:02.220Z\"}}], \"cna\": {\"title\": \"OS Command Injection via USB Config Load\", \"source\": {\"defect\": [\"CERT@VDE#641766\"], \"advisory\": \"VDE-2025-030\", \"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.8, \"attackVector\": \"PHYSICAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Frauscher\", \"product\": \"FDS102\", \"versions\": [{\"status\": \"affected\", \"version\": \"0.0.0\", \"lessThan\": \"v2.13.3\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Frauscher\", \"product\": \"FDS101\", \"versions\": [{\"status\": \"affected\", \"version\": \"0.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"v1.4.25\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Frauscher\", \"product\": \"FDS-SNMP101\", \"versions\": [{\"status\": \"affected\", \"version\": \"0.0.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"v.2.3.9\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://certvde.com/en/advisories/VDE-2025-030\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"shortName\": \"CERTVDE\", \"dateUpdated\": \"2025-07-07T09:20:03.263Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-3705\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-07-07T17:34:15.583Z\", \"dateReserved\": \"2025-04-16T06:43:57.178Z\", \"assignerOrgId\": \"270ccfa6-a436-4e77-922e-914ec3a9685c\", \"datePublished\": \"2025-07-07T09:20:03.263Z\", \"assignerShortName\": \"CERTVDE\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…