CVE-2024-41910 (GCVE-0-2024-41910)
Vulnerability from cvelistv5 – Published: 2024-08-06 14:05 – Updated: 2025-03-14 16:06
VLAI
Summary
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware contained multiple XSS vulnerabilities in the version of JavaScript used.
Severity
6.1 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | Poly Clariti Manager |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-41910",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T14:36:11.018010Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-14T16:06:19.571Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Poly Clariti Manager",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware contained multiple XSS vulnerabilities in the version of JavaScript used."
}
],
"providerMetadata": {
"dateUpdated": "2024-08-08T17:27:55.381Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_11006981-11007005-16/hpsbpy03960"
}
],
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2024-41910",
"datePublished": "2024-08-06T14:05:28.473Z",
"dateReserved": "2024-07-23T15:33:15.305Z",
"dateUpdated": "2025-03-14T16:06:19.571Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-41910",
"date": "2026-05-29",
"epss": "0.00807",
"percentile": "0.7448"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hp:poly_clariti_manager_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"10.10.2.2\", \"matchCriteriaId\": \"1ECAA137-00B5-48AA-9D9B-F5ACD13D4CF4\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hp:poly_clariti_manager:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A4A692C6-384C-4802-A6A2-4881B4B73A7B\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware contained multiple XSS vulnerabilities in the version of JavaScript used.\"}, {\"lang\": \"es\", \"value\": \"Se descubri\\u00f3 una vulnerabilidad en las versiones de firmware hasta 10.10.2.2 en dispositivos Poly Clariti Manager. El firmware conten\\u00eda m\\u00faltiples vulnerabilidades XXS en la versi\\u00f3n de JavaScript utilizada.\"}]",
"id": "CVE-2024-41910",
"lastModified": "2024-08-13T13:06:13.467",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 2.7}]}",
"published": "2024-08-06T14:16:04.350",
"references": "[{\"url\": \"https://support.hp.com/us-en/document/ish_11006981-11007005-16/hpsbpy03960\", \"source\": \"hp-security-alert@hp.com\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "hp-security-alert@hp.com",
"vulnStatus": "Analyzed",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-41910\",\"sourceIdentifier\":\"hp-security-alert@hp.com\",\"published\":\"2024-08-06T14:16:04.350\",\"lastModified\":\"2025-10-02T17:36:28.400\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware contained multiple XSS vulnerabilities in the version of JavaScript used.\"},{\"lang\":\"es\",\"value\":\"Se descubri\u00f3 una vulnerabilidad en las versiones de firmware hasta 10.10.2.2 en dispositivos Poly Clariti Manager. El firmware conten\u00eda m\u00faltiples vulnerabilidades XXS en la versi\u00f3n de JavaScript utilizada.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:poly_clariti_manager:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"10.12.0.2_100\",\"matchCriteriaId\":\"01297D80-BD62-405F-B5AC-934060D6696F\"}]}]}],\"references\":[{\"url\":\"https://support.hp.com/us-en/document/ish_11006981-11007005-16/hpsbpy03960\",\"source\":\"hp-security-alert@hp.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 6.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-41910\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-03T14:36:11.018010Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-08T18:02:27.931Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"HP Inc.\", \"product\": \"Poly Clariti Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"See HP Security Bulletin reference for affected versions.\"}]}], \"references\": [{\"url\": \"https://support.hp.com/us-en/document/ish_11006981-11007005-16/hpsbpy03960\"}], \"x_generator\": {\"engine\": \"cveClient/1.0.15\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware contained multiple XSS vulnerabilities in the version of JavaScript used.\"}], \"providerMetadata\": {\"orgId\": \"74586083-13ce-40fd-b46a-8e5d23cfbcb2\", \"shortName\": \"hp\", \"dateUpdated\": \"2024-08-08T17:27:55.381Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-41910\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-14T16:06:19.571Z\", \"dateReserved\": \"2024-07-23T15:33:15.305Z\", \"assignerOrgId\": \"74586083-13ce-40fd-b46a-8e5d23cfbcb2\", \"datePublished\": \"2024-08-06T14:05:28.473Z\", \"assignerShortName\": \"hp\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…