CVE-2023-50585 (GCVE-0-2023-50585)

Vulnerability from cvelistv5 – Published: 2024-01-09 00:00 – Updated: 2025-06-03 14:34
VLAI
Summary
Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-08 16:00 UTC
CWE
  • n/a
  • CWE-787 - Out-of-bounds Write
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:16:47.203Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-50585",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-08T16:00:01.273922Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-03T14:34:10.536Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-09T08:13:03.708Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-50585",
    "datePublished": "2024-01-09T00:00:00.000Z",
    "dateReserved": "2023-12-11T00:00:00.000Z",
    "dateUpdated": "2025-06-03T14:34:10.536Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2023-50585",
      "date": "2026-09-29",
      "epss": "0.00701",
      "percentile": "0.51351"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:tenda:a18_firmware:15.13.07.09:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0916A698-E859-4DA2-899C-5A55B68E25F1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "20146A03-30B3-4BFF-83DA-DEDBF6850A6B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function."
        },
        {
          "lang": "es",
          "value": "Se descubri\u00f3 que Tenda A18 v15.13.07.09 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro devName en la funci\u00f3n formSetDeviceName."
        }
      ],
      "id": "CVE-2023-50585",
      "lastModified": "2024-11-21T08:37:06.090",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2024-01-09T09:15:42.430",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "n/a",
                "vendor": "n/a",
                "versions": [
                  {
                    "status": "affected",
                    "version": "n/a"
                  }
                ]
              }
            ],
            "source": "cve@mitre.org"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tenda:a18_firmware:15.13.07.09:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0916A698-E859-4DA2-899C-5A55B68E25F1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "20146A03-30B3-4BFF-83DA-DEDBF6850A6B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function."
          },
          {
            "lang": "es",
            "value": "Se descubri\u00f3 que Tenda A18 v15.13.07.09 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro devName en la funci\u00f3n formSetDeviceName."
          }
        ],
        "id": "CVE-2023-50585",
        "lastModified": "2026-06-17T06:39:45.650",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2023-50585",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-08T16:00:01.273922Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-01-09T09:15:42.430",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-787"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-787"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:16:47.203Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-50585",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-08T16:00:01.273922Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-08T16:00:03.552Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-09T08:13:03.708Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-50585",
        "datePublished": "2024-01-09T00:00:00.000Z",
        "dateReserved": "2023-12-11T00:00:00.000Z",
        "dateUpdated": "2025-06-03T14:34:10.536Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…