CVE-2017-7574
Vulnerability from cvelistv5
Published
2017-04-06 21:00
Modified
2024-08-05 16:04
Severity ?
EPSS score ?
Summary
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.
References
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-01 | Vendor Advisory | |
cve@mitre.org | http://www.securityfocus.com/bid/97518 | Third Party Advisory, VDB Entry | |
cve@mitre.org | https://os-s.net/advisories/OSS-2017-02.pdf | Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-01 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/97518 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://os-s.net/advisories/OSS-2017-02.pdf | Broken Link |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T16:04:11.981Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-01" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://os-s.net/advisories/OSS-2017-02.pdf" }, { "name": "97518", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/97518" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2017-04-06T00:00:00", "descriptions": [ { "lang": "en", "value": "Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-04-14T04:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-01" }, { "tags": [ "x_refsource_MISC" ], "url": "https://os-s.net/advisories/OSS-2017-02.pdf" }, { "name": "97518", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/97518" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2017-7574", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-01", "refsource": "CONFIRM", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-01" }, { "name": "https://os-s.net/advisories/OSS-2017-02.pdf", "refsource": "MISC", "url": "https://os-s.net/advisories/OSS-2017-02.pdf" }, { "name": "97518", "refsource": "BID", "url": "http://www.securityfocus.com/bid/97518" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2017-7574", "datePublished": "2017-04-06T21:00:00", "dateReserved": "2017-04-06T00:00:00", "dateUpdated": "2024-08-05T16:04:11.981Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2017-7574\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2017-04-06T21:59:00.307\",\"lastModified\":\"2024-11-21T03:32:11.727\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.\"},{\"lang\":\"es\",\"value\":\"Los dispositivos Schneider Electric SoMachine Basic 1.4 SP1 y Schneider Electric Modicon TM221CE16R 1.3.3.3 tienen una vulnerabilidad de clave codificada. La funci\u00f3n Protecci\u00f3n de proyectos se utiliza para evitar que usuarios no autorizados abran un archivo de proyecto protegido XML, solicitando al usuario una contrase\u00f1a. Este archivo XML es AES-CBC cifrado; Sin embargo, no se puede cambiar la clave utilizada para el cifrado (SoMachineBasicSoMachineBasicSoMa). Despu\u00e9s de descifrar el archivo XML con esta clave, la contrase\u00f1a de usuario se puede encontrar en los datos descifrados. Despu\u00e9s de leer la contrase\u00f1a de usuario, el proyecto se puede abrir y modificar con el producto Schneider.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_tm221ce16r_firmware:1.3.3.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"26C40BAF-2C91-4069-A62E-1B1E60BA1619\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_tm221ce16r:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"00715571-AC4B-4B1F-8E65-385B56F2004C\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:somachine:1.4:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"85698ADE-078B-4461-BA24-C88BB16C6E50\"}]}]}],\"references\":[{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-01\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/97518\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://os-s.net/advisories/OSS-2017-02.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Broken Link\"]},{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/97518\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://os-s.net/advisories/OSS-2017-02.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.