    CVE-2024-3699 (GCVE-0-2024-3699)

    Vulnerability from nvd – Published: 2024-06-10 11:18 – Updated: 2025-10-03 09:02
    VLAI
    Title
    Hardcoded password in drEryk Gabinet
    Summary
    Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all drEryk Gabinet installations.This issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-259 - Use of Hard-coded Password
    Assigner
    References
    Impacted products
    Vendor Product Version
    drEryk sp. z o.o. drEryk Gabinet Affected: 7.0.0.0 , ≤ 9.17.0.0. (custom)
    Create a notification for this product.
    dreryk gabinet Affected: 7.0.0.0 , ≤ 9.17.0.0 (custom)
        cpe:2.3:a:dreryk:gabinet:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-06-10 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:dreryk:gabinet:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gabinet",
                "vendor": "dreryk",
                "versions": [
                  {
                    "lessThanOrEqual": "9.17.0.0",
                    "status": "affected",
                    "version": "7.0.0.0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-3699",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-10T17:04:15.430477Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-30T14:29:17.807Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:20:01.110Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/"
              },
              {
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/"
              },
              {
                "tags": [
                  "product",
                  "x_transferred"
                ],
                "url": "https://dreryk.pl/produkty/gabinet/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "drEryk Gabinet",
              "vendor": "drEryk sp. z o.o.",
              "versions": [
                {
                  "lessThanOrEqual": "9.17.0.0.",
                  "status": "affected",
                  "version": "7.0.0.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2024-06-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of hard-coded password to the patients\u0027 database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all\u0026nbsp;drEryk Gabinet installations.\u003cp\u003eThis issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0.\u003c/p\u003e"
                }
              ],
              "value": "Use of hard-coded password to the patients\u0027 database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all\u00a0drEryk Gabinet installations.This issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-37",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "RED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "CONCENTRATED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:H/SA:H/AU:Y/R:U/V:C/RE:M/U:Red",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "MODERATE"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-259",
                  "description": "CWE-259 Use of Hard-coded Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-03T09:02:57.709Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://dreryk.pl/produkty/gabinet/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Hardcoded password in drEryk Gabinet",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2024-3699",
        "datePublished": "2024-06-10T11:18:16.709Z",
        "dateReserved": "2024-04-12T08:51:41.949Z",
        "dateUpdated": "2025-10-03T09:02:57.709Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-3699 (GCVE-0-2024-3699)

    Vulnerability from cvelistv5 – Published: 2024-06-10 11:18 – Updated: 2025-10-03 09:02
    VLAI
    Title
    Hardcoded password in drEryk Gabinet
    Summary
    Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all drEryk Gabinet installations.This issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-259 - Use of Hard-coded Password
    Assigner
    References
    Impacted products
    Vendor Product Version
    drEryk sp. z o.o. drEryk Gabinet Affected: 7.0.0.0 , ≤ 9.17.0.0. (custom)
    Create a notification for this product.
    dreryk gabinet Affected: 7.0.0.0 , ≤ 9.17.0.0 (custom)
        cpe:2.3:a:dreryk:gabinet:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-06-10 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:dreryk:gabinet:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "gabinet",
                "vendor": "dreryk",
                "versions": [
                  {
                    "lessThanOrEqual": "9.17.0.0",
                    "status": "affected",
                    "version": "7.0.0.0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-3699",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-10T17:04:15.430477Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-30T14:29:17.807Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:20:01.110Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/"
              },
              {
                "tags": [
                  "third-party-advisory",
                  "x_transferred"
                ],
                "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/"
              },
              {
                "tags": [
                  "product",
                  "x_transferred"
                ],
                "url": "https://dreryk.pl/produkty/gabinet/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "drEryk Gabinet",
              "vendor": "drEryk sp. z o.o.",
              "versions": [
                {
                  "lessThanOrEqual": "9.17.0.0.",
                  "status": "affected",
                  "version": "7.0.0.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2024-06-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of hard-coded password to the patients\u0027 database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all\u0026nbsp;drEryk Gabinet installations.\u003cp\u003eThis issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0.\u003c/p\u003e"
                }
              ],
              "value": "Use of hard-coded password to the patients\u0027 database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all\u00a0drEryk Gabinet installations.This issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-37",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "YES",
                "Recovery": "USER",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "RED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "CONCENTRATED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:H/SA:H/AU:Y/R:U/V:C/RE:M/U:Red",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "MODERATE"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-259",
                  "description": "CWE-259 Use of Hard-coded Password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-10-03T09:02:57.709Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://dreryk.pl/produkty/gabinet/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Hardcoded password in drEryk Gabinet",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2024-3699",
        "datePublished": "2024-06-10T11:18:16.709Z",
        "dateReserved": "2024-04-12T08:51:41.949Z",
        "dateUpdated": "2025-10-03T09:02:57.709Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }