Search criteria

1 vulnerability by drEryk sp. z o.o.

CVE-2024-3699 (GCVE-0-2024-3699)

Vulnerability from cvelistv5 – Published: 2024-06-10 11:18 – Updated: 2025-10-03 09:02
VLAI?
Title
Hardcoded password in drEryk Gabinet
Summary
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all drEryk Gabinet installations.This issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0.
CWE
  • CWE-259 - Use of Hard-coded Password
Assigner
Impacted products
Vendor Product Version
drEryk sp. z o.o. drEryk Gabinet Affected: 7.0.0.0 , ≤ 9.17.0.0. (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:dreryk:gabinet:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gabinet",
            "vendor": "dreryk",
            "versions": [
              {
                "lessThanOrEqual": "9.17.0.0",
                "status": "affected",
                "version": "7.0.0.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-3699",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-10T17:04:15.430477Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-30T14:29:17.807Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:20:01.110Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/"
          },
          {
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/"
          },
          {
            "tags": [
              "product",
              "x_transferred"
            ],
            "url": "https://dreryk.pl/produkty/gabinet/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "drEryk Gabinet",
          "vendor": "drEryk sp. z o.o.",
          "versions": [
            {
              "lessThanOrEqual": "9.17.0.0.",
              "status": "affected",
              "version": "7.0.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2024-06-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Use of hard-coded password to the patients\u0027 database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all\u0026nbsp;drEryk Gabinet installations.\u003cp\u003eThis issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0.\u003c/p\u003e"
            }
          ],
          "value": "Use of hard-coded password to the patients\u0027 database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all\u00a0drEryk Gabinet installations.This issue affects drEryk Gabinet software versions from 7.0.0.0 through 9.17.0.0."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "USER",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "RED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "CONCENTRATED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:H/SA:H/AU:Y/R:U/V:C/RE:M/U:Red",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "MODERATE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "CWE-259 Use of Hard-coded Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-03T09:02:57.709Z",
        "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "shortName": "CERT-PL"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/en/posts/2024/06/CVE-2024-1228/"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://cert.pl/posts/2024/06/CVE-2024-1228/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://dreryk.pl/produkty/gabinet/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Hardcoded password in drEryk Gabinet",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
    "assignerShortName": "CERT-PL",
    "cveId": "CVE-2024-3699",
    "datePublished": "2024-06-10T11:18:16.709Z",
    "dateReserved": "2024-04-12T08:51:41.949Z",
    "dateUpdated": "2025-10-03T09:02:57.709Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}