Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    10 vulnerabilities by Pronetiqs

    CVE-2026-50044 (GCVE-0-2026-50044)

    Vulnerability from nvd – Published: 2026-07-23 22:03 – Updated: 2026-07-23 22:03
    VLAI
    Title
    Inadequate Encryption Strength in Panduit IntraVUE by Pronetiqs
    Summary
    Pronetiqs IntraVUE versions 3.2.1a14 and prior have an inadequate encryption strength vulnerability which could allow an attacker to steal admin credentials via weak hash or a pass-the-hash attack.
    CWE
    • CWE-326 - Inadequate Encryption Strength
    Assigner
    References
    Impacted products
    Vendor Product Version
    Pronetiqs Panduit Intravue Affected: 0 , ≤ 3.2.1a14 (custom)
    Create a notification for this product.
    Credits
    Phlebas of Lumintel reported this vulnerability to CISA
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Panduit Intravue",
              "vendor": "Pronetiqs",
              "versions": [
                {
                  "lessThanOrEqual": "3.2.1a14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Phlebas of Lumintel reported this vulnerability to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an inadequate encryption strength vulnerability which could allow an attacker to steal admin credentials via weak hash or a pass-the-hash attack."
                }
              ],
              "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an inadequate encryption strength vulnerability which could allow an attacker to steal admin credentials via weak hash or a pass-the-hash attack."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-326",
                  "description": "CWE-326 Inadequate Encryption Strength",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-23T22:03:25.523Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u0026nbsp;\nFor further questions, please contact Pronetiqs at info@pronetiqs.com.\u003cbr\u003e"
                }
              ],
              "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u00a0\nFor further questions, please contact Pronetiqs at info@pronetiqs.com."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Inadequate Encryption Strength in Panduit IntraVUE  by Pronetiqs",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-50044",
        "datePublished": "2026-07-23T22:03:25.523Z",
        "dateReserved": "2026-06-15T17:14:43.844Z",
        "dateUpdated": "2026-07-23T22:03:25.523Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44955 (GCVE-0-2026-44955)

    Vulnerability from nvd – Published: 2026-07-23 22:01 – Updated: 2026-07-23 22:05
    VLAI
    Title
    Exposure of Sensitive System Information to an Unauthorized Control Sphere in Panduit IntraVUE by Pronetiqs
    Summary
    Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could allow for asset discovery by unauthenticated users.
    CWE
    • CWE-497 - Exposure of sensitive system information to an unauthorized control sphere
    Assigner
    References
    Impacted products
    Vendor Product Version
    Pronetiqs Panduit Intravue Affected: 0 , ≤ 3.2.1a14 (custom)
    Create a notification for this product.
    Credits
    Phlebas of Lumintel reported this vulnerability to CISA
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Panduit Intravue",
              "vendor": "Pronetiqs",
              "versions": [
                {
                  "lessThanOrEqual": "3.2.1a14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Phlebas of Lumintel reported this vulnerability to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could allow for asset discovery by unauthenticated users."
                }
              ],
              "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could allow for asset discovery by unauthenticated users."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-497",
                  "description": "CWE-497 Exposure of sensitive system information to an unauthorized control sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-23T22:05:46.482Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u0026nbsp;\nFor further questions, please contact Pronetiqs at info@pronetiqs.com.\u003cbr\u003e"
                }
              ],
              "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u00a0\nFor further questions, please contact Pronetiqs at info@pronetiqs.com."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Exposure of Sensitive System Information to an Unauthorized Control Sphere in Panduit IntraVUE by Pronetiqs",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-44955",
        "datePublished": "2026-07-23T22:01:23.107Z",
        "dateReserved": "2026-06-15T17:14:43.840Z",
        "dateUpdated": "2026-07-23T22:05:46.482Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-42933 (GCVE-0-2026-42933)

    Vulnerability from nvd – Published: 2026-07-23 21:59 – Updated: 2026-07-23 22:06
    VLAI
    Title
    Unintended Proxy or Intermediary in Panduit IntraVUE by Pronetiqs
    Summary
    Pronetiqs IntraVUE versions 3.2.1a14 and prior have an unintended proxy or intermediary vulnerability which could allow an attacker to use an active proxy, which would bypass OT segmentation.
    CWE
    • CWE-441 - Unintended Proxy or Intermediary ('Confused Deputy')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Pronetiqs Panduit Intravue Affected: 0 , ≤ 3.2.1a14 (custom)
    Create a notification for this product.
    Credits
    Phlebas of Lumintel reported this vulnerability to CISA
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Panduit Intravue",
              "vendor": "Pronetiqs",
              "versions": [
                {
                  "lessThanOrEqual": "3.2.1a14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Phlebas of Lumintel reported this vulnerability to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an unintended proxy or intermediary vulnerability which could allow an attacker to use an active proxy, which would bypass OT segmentation."
                }
              ],
              "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an unintended proxy or intermediary vulnerability which could allow an attacker to use an active proxy, which would bypass OT segmentation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-441",
                  "description": "CWE-441 Unintended Proxy or Intermediary (\u0027Confused Deputy\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-23T22:06:21.795Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u0026nbsp;\nFor further questions, please contact Pronetiqs at info@pronetiqs.com.\u003cbr\u003e"
                }
              ],
              "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u00a0\nFor further questions, please contact Pronetiqs at info@pronetiqs.com."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unintended Proxy or Intermediary in Panduit IntraVUE by Pronetiqs",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-42933",
        "datePublished": "2026-07-23T21:59:50.055Z",
        "dateReserved": "2026-06-15T17:14:43.836Z",
        "dateUpdated": "2026-07-23T22:06:21.795Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-40430 (GCVE-0-2026-40430)

    Vulnerability from nvd – Published: 2026-07-23 21:58 – Updated: 2026-07-23 22:06
    VLAI
    Title
    Plaintext Storage of a Password in Panduit IntraVUE by Pronetiqs
    Summary
    Pronetiqs IntraVUE Versions 3.2.1a14 and prior have a plaintext storage of a password vulnerability that could expose cleartext credentials through the API.
    CWE
    • CWE-256 - Plaintext storage of a password
    Assigner
    References
    Impacted products
    Vendor Product Version
    Pronetiqs Panduit Intravue Affected: 0 , ≤ 3.2.1a14 (custom)
    Create a notification for this product.
    Credits
    Phlebas of Lumintel reported this vulnerability to CISA
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Panduit Intravue",
              "vendor": "Pronetiqs",
              "versions": [
                {
                  "lessThanOrEqual": "3.2.1a14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Phlebas of Lumintel reported this vulnerability to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs IntraVUE Versions 3.2.1a14 and prior have a plaintext storage of a password vulnerability that could expose cleartext credentials through the API."
                }
              ],
              "value": "Pronetiqs IntraVUE Versions 3.2.1a14 and prior have a plaintext storage of a password vulnerability that could expose cleartext credentials through the API."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-256",
                  "description": "CWE-256 Plaintext storage of a password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-23T22:06:51.349Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u0026nbsp;\nFor further questions, please contact Pronetiqs at info@pronetiqs.com.\u003cbr\u003e"
                }
              ],
              "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u00a0\nFor further questions, please contact Pronetiqs at info@pronetiqs.com."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Plaintext Storage of a Password in Panduit IntraVUE by Pronetiqs",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-40430",
        "datePublished": "2026-07-23T21:58:33.469Z",
        "dateReserved": "2026-06-15T17:14:43.830Z",
        "dateUpdated": "2026-07-23T22:06:51.349Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28698 (GCVE-0-2026-28698)

    Vulnerability from nvd – Published: 2026-07-23 22:04 – Updated: 2026-07-23 22:04
    VLAI
    Title
    Exposure of Sensitive System Information to an Unauthorized Control Sphere in Panduit IntraVUE by Pronetiqs
    Summary
    Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could expose the underlying host/share filesystem.
    CWE
    • CWE-497 - Exposure of sensitive system information to an unauthorized control sphere
    Assigner
    References
    Impacted products
    Vendor Product Version
    Pronetiqs Panduit Intravue Affected: 0 , ≤ 3.2.1a14 (custom)
    Create a notification for this product.
    Credits
    Phlebas of Lumintel reported this vulnerability to CISA
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Panduit Intravue",
              "vendor": "Pronetiqs",
              "versions": [
                {
                  "lessThanOrEqual": "3.2.1a14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Phlebas of Lumintel reported this vulnerability to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could expose the underlying host/share filesystem."
                }
              ],
              "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could expose the underlying host/share filesystem."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-497",
                  "description": "CWE-497 Exposure of sensitive system information to an unauthorized control sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-23T22:04:49.903Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u0026nbsp;\nFor further questions, please contact Pronetiqs at info@pronetiqs.com.\u003cbr\u003e"
                }
              ],
              "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u00a0\nFor further questions, please contact Pronetiqs at info@pronetiqs.com."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Exposure of Sensitive System Information to an Unauthorized Control Sphere in Panduit IntraVUE by Pronetiqs",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-28698",
        "datePublished": "2026-07-23T22:04:49.903Z",
        "dateReserved": "2026-06-15T17:14:43.847Z",
        "dateUpdated": "2026-07-23T22:04:49.903Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-28698 (GCVE-0-2026-28698)

    Vulnerability from cvelistv5 – Published: 2026-07-23 22:04 – Updated: 2026-07-23 22:04
    VLAI
    Title
    Exposure of Sensitive System Information to an Unauthorized Control Sphere in Panduit IntraVUE by Pronetiqs
    Summary
    Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could expose the underlying host/share filesystem.
    CWE
    • CWE-497 - Exposure of sensitive system information to an unauthorized control sphere
    Assigner
    References
    Impacted products
    Vendor Product Version
    Pronetiqs Panduit Intravue Affected: 0 , ≤ 3.2.1a14 (custom)
    Create a notification for this product.
    Credits
    Phlebas of Lumintel reported this vulnerability to CISA
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Panduit Intravue",
              "vendor": "Pronetiqs",
              "versions": [
                {
                  "lessThanOrEqual": "3.2.1a14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Phlebas of Lumintel reported this vulnerability to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could expose the underlying host/share filesystem."
                }
              ],
              "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could expose the underlying host/share filesystem."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-497",
                  "description": "CWE-497 Exposure of sensitive system information to an unauthorized control sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-23T22:04:49.903Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u0026nbsp;\nFor further questions, please contact Pronetiqs at info@pronetiqs.com.\u003cbr\u003e"
                }
              ],
              "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u00a0\nFor further questions, please contact Pronetiqs at info@pronetiqs.com."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Exposure of Sensitive System Information to an Unauthorized Control Sphere in Panduit IntraVUE by Pronetiqs",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-28698",
        "datePublished": "2026-07-23T22:04:49.903Z",
        "dateReserved": "2026-06-15T17:14:43.847Z",
        "dateUpdated": "2026-07-23T22:04:49.903Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-50044 (GCVE-0-2026-50044)

    Vulnerability from cvelistv5 – Published: 2026-07-23 22:03 – Updated: 2026-07-23 22:03
    VLAI
    Title
    Inadequate Encryption Strength in Panduit IntraVUE by Pronetiqs
    Summary
    Pronetiqs IntraVUE versions 3.2.1a14 and prior have an inadequate encryption strength vulnerability which could allow an attacker to steal admin credentials via weak hash or a pass-the-hash attack.
    CWE
    • CWE-326 - Inadequate Encryption Strength
    Assigner
    References
    Impacted products
    Vendor Product Version
    Pronetiqs Panduit Intravue Affected: 0 , ≤ 3.2.1a14 (custom)
    Create a notification for this product.
    Credits
    Phlebas of Lumintel reported this vulnerability to CISA
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Panduit Intravue",
              "vendor": "Pronetiqs",
              "versions": [
                {
                  "lessThanOrEqual": "3.2.1a14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Phlebas of Lumintel reported this vulnerability to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an inadequate encryption strength vulnerability which could allow an attacker to steal admin credentials via weak hash or a pass-the-hash attack."
                }
              ],
              "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an inadequate encryption strength vulnerability which could allow an attacker to steal admin credentials via weak hash or a pass-the-hash attack."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-326",
                  "description": "CWE-326 Inadequate Encryption Strength",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-23T22:03:25.523Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u0026nbsp;\nFor further questions, please contact Pronetiqs at info@pronetiqs.com.\u003cbr\u003e"
                }
              ],
              "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u00a0\nFor further questions, please contact Pronetiqs at info@pronetiqs.com."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Inadequate Encryption Strength in Panduit IntraVUE  by Pronetiqs",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-50044",
        "datePublished": "2026-07-23T22:03:25.523Z",
        "dateReserved": "2026-06-15T17:14:43.844Z",
        "dateUpdated": "2026-07-23T22:03:25.523Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-44955 (GCVE-0-2026-44955)

    Vulnerability from cvelistv5 – Published: 2026-07-23 22:01 – Updated: 2026-07-23 22:05
    VLAI
    Title
    Exposure of Sensitive System Information to an Unauthorized Control Sphere in Panduit IntraVUE by Pronetiqs
    Summary
    Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could allow for asset discovery by unauthenticated users.
    CWE
    • CWE-497 - Exposure of sensitive system information to an unauthorized control sphere
    Assigner
    References
    Impacted products
    Vendor Product Version
    Pronetiqs Panduit Intravue Affected: 0 , ≤ 3.2.1a14 (custom)
    Create a notification for this product.
    Credits
    Phlebas of Lumintel reported this vulnerability to CISA
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Panduit Intravue",
              "vendor": "Pronetiqs",
              "versions": [
                {
                  "lessThanOrEqual": "3.2.1a14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Phlebas of Lumintel reported this vulnerability to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could allow for asset discovery by unauthenticated users."
                }
              ],
              "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an exposure of sensitive system information to an unauthorized control sphere vulnerability which could allow for asset discovery by unauthenticated users."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-497",
                  "description": "CWE-497 Exposure of sensitive system information to an unauthorized control sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-23T22:05:46.482Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u0026nbsp;\nFor further questions, please contact Pronetiqs at info@pronetiqs.com.\u003cbr\u003e"
                }
              ],
              "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u00a0\nFor further questions, please contact Pronetiqs at info@pronetiqs.com."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Exposure of Sensitive System Information to an Unauthorized Control Sphere in Panduit IntraVUE by Pronetiqs",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-44955",
        "datePublished": "2026-07-23T22:01:23.107Z",
        "dateReserved": "2026-06-15T17:14:43.840Z",
        "dateUpdated": "2026-07-23T22:05:46.482Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-42933 (GCVE-0-2026-42933)

    Vulnerability from cvelistv5 – Published: 2026-07-23 21:59 – Updated: 2026-07-23 22:06
    VLAI
    Title
    Unintended Proxy or Intermediary in Panduit IntraVUE by Pronetiqs
    Summary
    Pronetiqs IntraVUE versions 3.2.1a14 and prior have an unintended proxy or intermediary vulnerability which could allow an attacker to use an active proxy, which would bypass OT segmentation.
    CWE
    • CWE-441 - Unintended Proxy or Intermediary ('Confused Deputy')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Pronetiqs Panduit Intravue Affected: 0 , ≤ 3.2.1a14 (custom)
    Create a notification for this product.
    Credits
    Phlebas of Lumintel reported this vulnerability to CISA
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Panduit Intravue",
              "vendor": "Pronetiqs",
              "versions": [
                {
                  "lessThanOrEqual": "3.2.1a14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Phlebas of Lumintel reported this vulnerability to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an unintended proxy or intermediary vulnerability which could allow an attacker to use an active proxy, which would bypass OT segmentation."
                }
              ],
              "value": "Pronetiqs IntraVUE versions 3.2.1a14 and prior have an unintended proxy or intermediary vulnerability which could allow an attacker to use an active proxy, which would bypass OT segmentation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-441",
                  "description": "CWE-441 Unintended Proxy or Intermediary (\u0027Confused Deputy\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-23T22:06:21.795Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u0026nbsp;\nFor further questions, please contact Pronetiqs at info@pronetiqs.com.\u003cbr\u003e"
                }
              ],
              "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u00a0\nFor further questions, please contact Pronetiqs at info@pronetiqs.com."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unintended Proxy or Intermediary in Panduit IntraVUE by Pronetiqs",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-42933",
        "datePublished": "2026-07-23T21:59:50.055Z",
        "dateReserved": "2026-06-15T17:14:43.836Z",
        "dateUpdated": "2026-07-23T22:06:21.795Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-40430 (GCVE-0-2026-40430)

    Vulnerability from cvelistv5 – Published: 2026-07-23 21:58 – Updated: 2026-07-23 22:06
    VLAI
    Title
    Plaintext Storage of a Password in Panduit IntraVUE by Pronetiqs
    Summary
    Pronetiqs IntraVUE Versions 3.2.1a14 and prior have a plaintext storage of a password vulnerability that could expose cleartext credentials through the API.
    CWE
    • CWE-256 - Plaintext storage of a password
    Assigner
    References
    Impacted products
    Vendor Product Version
    Pronetiqs Panduit Intravue Affected: 0 , ≤ 3.2.1a14 (custom)
    Create a notification for this product.
    Credits
    Phlebas of Lumintel reported this vulnerability to CISA
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Panduit Intravue",
              "vendor": "Pronetiqs",
              "versions": [
                {
                  "lessThanOrEqual": "3.2.1a14",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Phlebas of Lumintel reported this vulnerability to CISA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs IntraVUE Versions 3.2.1a14 and prior have a plaintext storage of a password vulnerability that could expose cleartext credentials through the API."
                }
              ],
              "value": "Pronetiqs IntraVUE Versions 3.2.1a14 and prior have a plaintext storage of a password vulnerability that could expose cleartext credentials through the API."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-256",
                  "description": "CWE-256 Plaintext storage of a password",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-07-23T22:06:51.349Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-04"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u0026nbsp;\nFor further questions, please contact Pronetiqs at info@pronetiqs.com.\u003cbr\u003e"
                }
              ],
              "value": "Pronetiqs advises users to update to the latest version of the IntraVUE software, version 3.2.1a16 or later.\u00a0\nFor further questions, please contact Pronetiqs at info@pronetiqs.com."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Plaintext Storage of a Password in Panduit IntraVUE by Pronetiqs",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-40430",
        "datePublished": "2026-07-23T21:58:33.469Z",
        "dateReserved": "2026-06-15T17:14:43.830Z",
        "dateUpdated": "2026-07-23T22:06:51.349Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }