Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    8 vulnerabilities by General Industrial Controls

    CVE-2025-62765 (GCVE-0-2025-62765)

    Vulnerability from cvelistv5 – Published: 2025-11-14 23:27 – Updated: 2025-11-17 16:54
    VLAI
    Title
    General Industrial Controls Lynx+ Gateway Cleartext Transmission of Sensitive Information
    Summary
    General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow an attacker to observe network traffic to obtain sensitive information, including plaintext credentials.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    General Industrial Controls Lynx+ Gateway Affected: Version R08
    Affected: Version V03
    Affected: Version V05
    Affected: Version V18
    Create a notification for this product.
    Credits
    Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-62765",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-17T16:54:52.076509Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-17T16:54:56.898Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Lynx+ Gateway",
              "vendor": "General Industrial Controls",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version R08"
                },
                {
                  "status": "affected",
                  "version": "Version V03"
                },
                {
                  "status": "affected",
                  "version": "Version V05"
                },
                {
                  "status": "affected",
                  "version": "Version V18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is vulnerable to a cleartext transmission vulnerability that could allow\n an attacker to observe network traffic to obtain sensitive information,\n including plaintext credentials."
                }
              ],
              "value": "General Industrial Controls Lynx+ Gateway\u00a0is vulnerable to a cleartext transmission vulnerability that could allow\n an attacker to observe network traffic to obtain sensitive information,\n including plaintext credentials."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-14T23:27:55.174Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
            }
          ],
          "source": {
            "advisory": "ICSA-25-317-08",
            "discovery": "EXTERNAL"
          },
          "title": "General Industrial Controls Lynx+ Gateway Cleartext Transmission of Sensitive Information",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-62765",
        "datePublished": "2025-11-14T23:27:55.174Z",
        "dateReserved": "2025-11-06T20:44:49.374Z",
        "dateUpdated": "2025-11-17T16:54:56.898Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-59780 (GCVE-0-2025-59780)

    Vulnerability from cvelistv5 – Published: 2025-11-14 23:26 – Updated: 2025-11-17 16:54
    VLAI
    Title
    General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function
    Summary
    General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which could allow an attacker to send GET requests to obtain sensitive device information.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    General Industrial Controls Lynx+ Gateway Affected: Version R08
    Affected: Version V03
    Affected: Version V05
    Affected: Version V18
    Create a notification for this product.
    Credits
    Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-59780",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-17T16:53:36.856914Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-17T16:54:08.683Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Lynx+ Gateway",
              "vendor": "General Industrial Controls",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version R08"
                },
                {
                  "status": "affected",
                  "version": "Version V03"
                },
                {
                  "status": "affected",
                  "version": "Version V05"
                },
                {
                  "status": "affected",
                  "version": "Version V18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is missing critical authentication in the embedded web server which \ncould allow an attacker to send GET requests to obtain sensitive device \ninformation."
                }
              ],
              "value": "General Industrial Controls Lynx+ Gateway\u00a0is missing critical authentication in the embedded web server which \ncould allow an attacker to send GET requests to obtain sensitive device \ninformation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-14T23:26:35.691Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
            }
          ],
          "source": {
            "advisory": "ICSA-25-317-08",
            "discovery": "EXTERNAL"
          },
          "title": "General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-59780",
        "datePublished": "2025-11-14T23:26:35.691Z",
        "dateReserved": "2025-11-06T20:44:49.360Z",
        "dateUpdated": "2025-11-17T16:54:08.683Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-58083 (GCVE-0-2025-58083)

    Vulnerability from cvelistv5 – Published: 2025-11-14 23:24 – Updated: 2025-11-17 14:35
    VLAI
    Title
    General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function
    Summary
    General Industrial Controls Lynx+ Gateway  is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    General Industrial Controls Lynx+ Gateway Affected: Version R08
    Affected: Version V03
    Affected: Version V05
    Affected: Version V18
    Create a notification for this product.
    Credits
    Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-58083",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-17T14:34:42.570290Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-17T14:35:13.251Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Lynx+ Gateway",
              "vendor": "General Industrial Controls",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version R08"
                },
                {
                  "status": "affected",
                  "version": "Version V03"
                },
                {
                  "status": "affected",
                  "version": "Version V05"
                },
                {
                  "status": "affected",
                  "version": "Version V18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;\n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device."
                }
              ],
              "value": "General Industrial Controls Lynx+ Gateway\u00a0\n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-14T23:24:54.274Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
            }
          ],
          "source": {
            "advisory": "ICSA-25-317-08",
            "discovery": "EXTERNAL"
          },
          "title": "General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-58083",
        "datePublished": "2025-11-14T23:24:54.274Z",
        "dateReserved": "2025-11-06T20:44:49.352Z",
        "dateUpdated": "2025-11-17T14:35:13.251Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-55034 (GCVE-0-2025-55034)

    Vulnerability from cvelistv5 – Published: 2025-11-14 23:22 – Updated: 2025-11-17 14:53
    VLAI
    Title
    General Industrial Controls Lynx+ Gateway Weak Password Requirements
    Summary
    General Industrial Controls Lynx+ Gateway is vulnerable to a weak password requirement vulnerability, which may allow an attacker to execute a brute-force attack resulting in unauthorized access and login.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    General Industrial Controls Lynx+ Gateway Affected: Version R08
    Affected: Version V03
    Affected: Version V05
    Affected: Version V18
    Create a notification for this product.
    Credits
    Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-55034",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-17T14:53:21.799019Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-17T14:53:32.111Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Lynx+ Gateway",
              "vendor": "General Industrial Controls",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version R08"
                },
                {
                  "status": "affected",
                  "version": "Version V03"
                },
                {
                  "status": "affected",
                  "version": "Version V05"
                },
                {
                  "status": "affected",
                  "version": "Version V18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is vulnerable to a weak password requirement vulnerability, which may \nallow an attacker to execute a brute-force attack resulting in \nunauthorized access and login."
                }
              ],
              "value": "General Industrial Controls Lynx+ Gateway\u00a0is vulnerable to a weak password requirement vulnerability, which may \nallow an attacker to execute a brute-force attack resulting in \nunauthorized access and login."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-521",
                  "description": "CWE-521",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-14T23:22:29.031Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
            }
          ],
          "source": {
            "advisory": "ICSA-25-317-08",
            "discovery": "EXTERNAL"
          },
          "title": "General Industrial Controls Lynx+ Gateway Weak Password Requirements",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-55034",
        "datePublished": "2025-11-14T23:22:29.031Z",
        "dateReserved": "2025-11-06T20:44:49.330Z",
        "dateUpdated": "2025-11-17T14:53:32.111Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-62765 (GCVE-0-2025-62765)

    Vulnerability from nvd – Published: 2025-11-14 23:27 – Updated: 2025-11-17 16:54
    VLAI
    Title
    General Industrial Controls Lynx+ Gateway Cleartext Transmission of Sensitive Information
    Summary
    General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow an attacker to observe network traffic to obtain sensitive information, including plaintext credentials.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    General Industrial Controls Lynx+ Gateway Affected: Version R08
    Affected: Version V03
    Affected: Version V05
    Affected: Version V18
    Create a notification for this product.
    Credits
    Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-62765",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-17T16:54:52.076509Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-17T16:54:56.898Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Lynx+ Gateway",
              "vendor": "General Industrial Controls",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version R08"
                },
                {
                  "status": "affected",
                  "version": "Version V03"
                },
                {
                  "status": "affected",
                  "version": "Version V05"
                },
                {
                  "status": "affected",
                  "version": "Version V18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is vulnerable to a cleartext transmission vulnerability that could allow\n an attacker to observe network traffic to obtain sensitive information,\n including plaintext credentials."
                }
              ],
              "value": "General Industrial Controls Lynx+ Gateway\u00a0is vulnerable to a cleartext transmission vulnerability that could allow\n an attacker to observe network traffic to obtain sensitive information,\n including plaintext credentials."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-14T23:27:55.174Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
            }
          ],
          "source": {
            "advisory": "ICSA-25-317-08",
            "discovery": "EXTERNAL"
          },
          "title": "General Industrial Controls Lynx+ Gateway Cleartext Transmission of Sensitive Information",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-62765",
        "datePublished": "2025-11-14T23:27:55.174Z",
        "dateReserved": "2025-11-06T20:44:49.374Z",
        "dateUpdated": "2025-11-17T16:54:56.898Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-59780 (GCVE-0-2025-59780)

    Vulnerability from nvd – Published: 2025-11-14 23:26 – Updated: 2025-11-17 16:54
    VLAI
    Title
    General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function
    Summary
    General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which could allow an attacker to send GET requests to obtain sensitive device information.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    General Industrial Controls Lynx+ Gateway Affected: Version R08
    Affected: Version V03
    Affected: Version V05
    Affected: Version V18
    Create a notification for this product.
    Credits
    Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-59780",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-17T16:53:36.856914Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-17T16:54:08.683Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Lynx+ Gateway",
              "vendor": "General Industrial Controls",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version R08"
                },
                {
                  "status": "affected",
                  "version": "Version V03"
                },
                {
                  "status": "affected",
                  "version": "Version V05"
                },
                {
                  "status": "affected",
                  "version": "Version V18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is missing critical authentication in the embedded web server which \ncould allow an attacker to send GET requests to obtain sensitive device \ninformation."
                }
              ],
              "value": "General Industrial Controls Lynx+ Gateway\u00a0is missing critical authentication in the embedded web server which \ncould allow an attacker to send GET requests to obtain sensitive device \ninformation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-14T23:26:35.691Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
            }
          ],
          "source": {
            "advisory": "ICSA-25-317-08",
            "discovery": "EXTERNAL"
          },
          "title": "General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-59780",
        "datePublished": "2025-11-14T23:26:35.691Z",
        "dateReserved": "2025-11-06T20:44:49.360Z",
        "dateUpdated": "2025-11-17T16:54:08.683Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-58083 (GCVE-0-2025-58083)

    Vulnerability from nvd – Published: 2025-11-14 23:24 – Updated: 2025-11-17 14:35
    VLAI
    Title
    General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function
    Summary
    General Industrial Controls Lynx+ Gateway  is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    General Industrial Controls Lynx+ Gateway Affected: Version R08
    Affected: Version V03
    Affected: Version V05
    Affected: Version V18
    Create a notification for this product.
    Credits
    Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-58083",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-17T14:34:42.570290Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-17T14:35:13.251Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Lynx+ Gateway",
              "vendor": "General Industrial Controls",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version R08"
                },
                {
                  "status": "affected",
                  "version": "Version V03"
                },
                {
                  "status": "affected",
                  "version": "Version V05"
                },
                {
                  "status": "affected",
                  "version": "Version V18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;\n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device."
                }
              ],
              "value": "General Industrial Controls Lynx+ Gateway\u00a0\n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:H/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-14T23:24:54.274Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
            }
          ],
          "source": {
            "advisory": "ICSA-25-317-08",
            "discovery": "EXTERNAL"
          },
          "title": "General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-58083",
        "datePublished": "2025-11-14T23:24:54.274Z",
        "dateReserved": "2025-11-06T20:44:49.352Z",
        "dateUpdated": "2025-11-17T14:35:13.251Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-55034 (GCVE-0-2025-55034)

    Vulnerability from nvd – Published: 2025-11-14 23:22 – Updated: 2025-11-17 14:53
    VLAI
    Title
    General Industrial Controls Lynx+ Gateway Weak Password Requirements
    Summary
    General Industrial Controls Lynx+ Gateway is vulnerable to a weak password requirement vulnerability, which may allow an attacker to execute a brute-force attack resulting in unauthorized access and login.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    General Industrial Controls Lynx+ Gateway Affected: Version R08
    Affected: Version V03
    Affected: Version V05
    Affected: Version V18
    Create a notification for this product.
    Credits
    Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-55034",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-11-17T14:53:21.799019Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-11-17T14:53:32.111Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Lynx+ Gateway",
              "vendor": "General Industrial Controls",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version R08"
                },
                {
                  "status": "affected",
                  "version": "Version V03"
                },
                {
                  "status": "affected",
                  "version": "Version V05"
                },
                {
                  "status": "affected",
                  "version": "Version V18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is vulnerable to a weak password requirement vulnerability, which may \nallow an attacker to execute a brute-force attack resulting in \nunauthorized access and login."
                }
              ],
              "value": "General Industrial Controls Lynx+ Gateway\u00a0is vulnerable to a weak password requirement vulnerability, which may \nallow an attacker to execute a brute-force attack resulting in \nunauthorized access and login."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-521",
                  "description": "CWE-521",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-11-14T23:22:29.031Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
            }
          ],
          "source": {
            "advisory": "ICSA-25-317-08",
            "discovery": "EXTERNAL"
          },
          "title": "General Industrial Controls Lynx+ Gateway Weak Password Requirements",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-55034",
        "datePublished": "2025-11-14T23:22:29.031Z",
        "dateReserved": "2025-11-06T20:44:49.330Z",
        "dateUpdated": "2025-11-17T14:53:32.111Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }