Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

4 vulnerabilities by General Industrial Controls

CVE-2025-62765 (GCVE-0-2025-62765)

Vulnerability from cvelistv5 – Published: 2025-11-14 23:27 – Updated: 2025-11-17 16:54
VLAI
Title
General Industrial Controls Lynx+ Gateway Cleartext Transmission of Sensitive Information
Summary
General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow an attacker to observe network traffic to obtain sensitive information, including plaintext credentials.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
General Industrial Controls Lynx+ Gateway Affected: Version R08
Affected: Version V03
Affected: Version V05
Affected: Version V18
Create a notification for this product.
Credits
Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-62765",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T16:54:52.076509Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T16:54:56.898Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Lynx+ Gateway",
          "vendor": "General Industrial Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Version R08"
            },
            {
              "status": "affected",
              "version": "Version V03"
            },
            {
              "status": "affected",
              "version": "Version V05"
            },
            {
              "status": "affected",
              "version": "Version V18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is vulnerable to a cleartext transmission vulnerability that could allow\n an attacker to observe network traffic to obtain sensitive information,\n including plaintext credentials."
            }
          ],
          "value": "General Industrial Controls Lynx+ Gateway\u00a0is vulnerable to a cleartext transmission vulnerability that could allow\n an attacker to observe network traffic to obtain sensitive information,\n including plaintext credentials."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T23:27:55.174Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
        }
      ],
      "source": {
        "advisory": "ICSA-25-317-08",
        "discovery": "EXTERNAL"
      },
      "title": "General Industrial Controls Lynx+ Gateway Cleartext Transmission of Sensitive Information",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-62765",
    "datePublished": "2025-11-14T23:27:55.174Z",
    "dateReserved": "2025-11-06T20:44:49.374Z",
    "dateUpdated": "2025-11-17T16:54:56.898Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-59780 (GCVE-0-2025-59780)

Vulnerability from cvelistv5 – Published: 2025-11-14 23:26 – Updated: 2025-11-17 16:54
VLAI
Title
General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function
Summary
General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which could allow an attacker to send GET requests to obtain sensitive device information.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
General Industrial Controls Lynx+ Gateway Affected: Version R08
Affected: Version V03
Affected: Version V05
Affected: Version V18
Create a notification for this product.
Credits
Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-59780",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T16:53:36.856914Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T16:54:08.683Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Lynx+ Gateway",
          "vendor": "General Industrial Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Version R08"
            },
            {
              "status": "affected",
              "version": "Version V03"
            },
            {
              "status": "affected",
              "version": "Version V05"
            },
            {
              "status": "affected",
              "version": "Version V18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is missing critical authentication in the embedded web server which \ncould allow an attacker to send GET requests to obtain sensitive device \ninformation."
            }
          ],
          "value": "General Industrial Controls Lynx+ Gateway\u00a0is missing critical authentication in the embedded web server which \ncould allow an attacker to send GET requests to obtain sensitive device \ninformation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T23:26:35.691Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
        }
      ],
      "source": {
        "advisory": "ICSA-25-317-08",
        "discovery": "EXTERNAL"
      },
      "title": "General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-59780",
    "datePublished": "2025-11-14T23:26:35.691Z",
    "dateReserved": "2025-11-06T20:44:49.360Z",
    "dateUpdated": "2025-11-17T16:54:08.683Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-58083 (GCVE-0-2025-58083)

Vulnerability from cvelistv5 – Published: 2025-11-14 23:24 – Updated: 2025-11-17 14:35
VLAI
Title
General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function
Summary
General Industrial Controls Lynx+ Gateway  is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
General Industrial Controls Lynx+ Gateway Affected: Version R08
Affected: Version V03
Affected: Version V05
Affected: Version V18
Create a notification for this product.
Credits
Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-58083",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T14:34:42.570290Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T14:35:13.251Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Lynx+ Gateway",
          "vendor": "General Industrial Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Version R08"
            },
            {
              "status": "affected",
              "version": "Version V03"
            },
            {
              "status": "affected",
              "version": "Version V05"
            },
            {
              "status": "affected",
              "version": "Version V18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;\n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device."
            }
          ],
          "value": "General Industrial Controls Lynx+ Gateway\u00a0\n is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.2,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:H/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T23:24:54.274Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
        }
      ],
      "source": {
        "advisory": "ICSA-25-317-08",
        "discovery": "EXTERNAL"
      },
      "title": "General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-58083",
    "datePublished": "2025-11-14T23:24:54.274Z",
    "dateReserved": "2025-11-06T20:44:49.352Z",
    "dateUpdated": "2025-11-17T14:35:13.251Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-55034 (GCVE-0-2025-55034)

Vulnerability from cvelistv5 – Published: 2025-11-14 23:22 – Updated: 2025-11-17 14:53
VLAI
Title
General Industrial Controls Lynx+ Gateway Weak Password Requirements
Summary
General Industrial Controls Lynx+ Gateway is vulnerable to a weak password requirement vulnerability, which may allow an attacker to execute a brute-force attack resulting in unauthorized access and login.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
General Industrial Controls Lynx+ Gateway Affected: Version R08
Affected: Version V03
Affected: Version V05
Affected: Version V18
Create a notification for this product.
Credits
Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-55034",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T14:53:21.799019Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T14:53:32.111Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Lynx+ Gateway",
          "vendor": "General Industrial Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Version R08"
            },
            {
              "status": "affected",
              "version": "Version V03"
            },
            {
              "status": "affected",
              "version": "Version V05"
            },
            {
              "status": "affected",
              "version": "Version V18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls Lynx+ Gateway\u0026nbsp;is vulnerable to a weak password requirement vulnerability, which may \nallow an attacker to execute a brute-force attack resulting in \nunauthorized access and login."
            }
          ],
          "value": "General Industrial Controls Lynx+ Gateway\u00a0is vulnerable to a weak password requirement vulnerability, which may \nallow an attacker to execute a brute-force attack resulting in \nunauthorized access and login."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-521",
              "description": "CWE-521",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T23:22:29.031Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
        }
      ],
      "source": {
        "advisory": "ICSA-25-317-08",
        "discovery": "EXTERNAL"
      },
      "title": "General Industrial Controls Lynx+ Gateway Weak Password Requirements",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to \u003ca target=\"_blank\" rel=\"nofollow\"\u003eGIC\u003c/a\u003e for more information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "General Industrial Controls (GIC) did not respond to CISA\u0027s attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-55034",
    "datePublished": "2025-11-14T23:22:29.031Z",
    "dateReserved": "2025-11-06T20:44:49.330Z",
    "dateUpdated": "2025-11-17T14:53:32.111Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}