Vulnerabilites related to siemens - scalance_wum766-1_6ghz
Vulnerability from fkie_nvd
Published
2021-05-11 20:15
Modified
2024-11-21 05:15
Summary
The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn't require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary can abuse this to inject arbitrary network packets.
References
cve@mitre.orghttp://www.openwall.com/lists/oss-security/2021/05/11/12Mailing List, Third Party Advisory
cve@mitre.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdfThird Party Advisory
cve@mitre.orghttps://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.mdThird Party Advisory
cve@mitre.orghttps://lists.debian.org/debian-lts-announce/2021/06/msg00019.htmlMailing List, Third Party Advisory
cve@mitre.orghttps://lists.debian.org/debian-lts-announce/2021/06/msg00020.htmlMailing List, Third Party Advisory
cve@mitre.orghttps://lists.debian.org/debian-lts-announce/2023/04/msg00002.html
cve@mitre.orghttps://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWuThird Party Advisory
cve@mitre.orghttps://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63Third Party Advisory
cve@mitre.orghttps://www.fragattacks.comExploit, Third Party Advisory
cve@mitre.orghttps://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00473.htmlThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/05/11/12Mailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdfThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.mdThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2021/06/msg00019.htmlMailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2021/06/msg00020.htmlMailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2023/04/msg00002.html
af854a3a-2127-422b-91ae-364da2661108https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWuThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.fragattacks.comExploit, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00473.htmlThird Party Advisory
Impacted products
Vendor Product Version
ieee ieee_802.11 *
linux mac80211 -
microsoft windows_10 -
microsoft windows_10 20h2
microsoft windows_10 1607
microsoft windows_10 1803
microsoft windows_10 1809
microsoft windows_10 1909
microsoft windows_10 2004
microsoft windows_7 -
microsoft windows_8.1 -
microsoft windows_rt_8.1 -
microsoft windows_server_2008 -
microsoft windows_server_2008 r2
microsoft windows_server_2012 -
microsoft windows_server_2012 -
microsoft windows_server_2016 -
microsoft windows_server_2016 2004
microsoft windows_server_2019 -
debian debian_linux 9.0
siemens scalance_w1748-1_firmware -
siemens scalance_w1748-1 -
siemens scalance_w1750d_firmware -
siemens scalance_w1750d -
siemens scalance_w1788-1_firmware -
siemens scalance_w1788-1 -
siemens scalance_w1788-2_firmware -
siemens scalance_w1788-2 -
siemens scalance_w1788-2_firmware -
siemens scalance_w1788-2 -
siemens scalance_w1788-2ia_firmware -
siemens scalance_w1788-2ia -
siemens scalance_w721-1_firmware -
siemens scalance_w721-1 -
siemens scalance_w722-1_firmware -
siemens scalance_w722-1 -
siemens scalance_w734-1_firmware -
siemens scalance_w734-1 -
siemens scalance_w738-1_firmware -
siemens scalance_w738-1 -
siemens scalance_w748-1_firmware -
siemens scalance_w748-1 -
siemens scalance_w748-1_firmware -
siemens scalance_w748-1 -
siemens scalance_w761-1_firmware -
siemens scalance_w761-1 -
siemens scalance_w774-1_firmware -
siemens scalance_w774-1 -
siemens scalance_w774-1_firmware -
siemens scalance_w774-1 -
siemens scalance_w778-1_firmware -
siemens scalance_w778-1 -
siemens scalance_w778-1_firmware -
siemens scalance_w778-1 -
siemens scalance_w786-1_firmware -
siemens scalance_w786-1 -
siemens scalance_w786-2_firmware -
siemens scalance_w786-2 -
siemens scalance_w786-2_firmware -
siemens scalance_w786-2 -
siemens scalance_w786-2ia_firmware -
siemens scalance_w786-2ia -
siemens scalance_w788-1_firmware -
siemens scalance_w788-1 -
siemens scalance_w788-1_firmware -
siemens scalance_w788-1 -
siemens scalance_w788-2_firmware -
siemens scalance_w788-2 -
siemens scalance_w788-2_firmware -
siemens scalance_w788-2 -
siemens scalance_w788-2_firmware -
siemens scalance_w788-2 -
siemens scalance_wam763-1_firmware -
siemens scalance_wam763-1 -
siemens scalance_wam766-1_firmware -
siemens scalance_wam766-1 -
siemens scalance_wam766-1_firmware -
siemens scalance_wam766-1 -
siemens scalance_wam766-1_6ghz_firmware -
siemens scalance_wam766-1_6ghz -
siemens scalance_wam766-1_6ghz_firmware -
siemens scalance_wam766-1_6ghz -
siemens scalance_wum763-1_firmware -
siemens scalance_wum763-1 -
siemens scalance_wum766-1_firmware -
siemens scalance_wum766-1 -
siemens scalance_wum766-1_6ghz_firmware -
siemens scalance_wum766-1_6ghz -
arista c-100_firmware -
arista c-100 -
arista c-110_firmware -
arista c-110 -
arista c-120_firmware -
arista c-120 -
arista c-130_firmware -
arista c-130 -
arista c-200_firmware -
arista c-200 -
arista c-230_firmware -
arista c-230 -
arista c-235_firmware -
arista c-235 -
arista c-250_firmware -
arista c-250 -
arista c-260_firmware -
arista c-260 -
arista c-65_firmware -
arista c-65 -
arista c-75_firmware -
arista c-75 -
arista o-105_firmware -
arista o-105 -
arista o-90_firmware -
arista o-90 -
arista w-118_firmware -
arista w-118 -
arista w-68_firmware -
arista w-68 -
cisco 1100_firmware -
cisco 1100 -
cisco 1100-4p_firmware -
cisco 1100-4p -
cisco 1100-8p_firmware -
cisco 1100-8p -
cisco 1101-4p_firmware -
cisco 1101-4p -
cisco 1109-2p_firmware -
cisco 1109-2p -
cisco 1109-4p_firmware -
cisco 1109-4p -
cisco aironet_1532_firmware -
cisco aironet_1532 -
cisco aironet_1542d_firmware -
cisco aironet_1542d -
cisco aironet_1542i_firmware -
cisco aironet_1542i -
cisco aironet_1800_firmware -
cisco aironet_1800 -
cisco aironet_1800i_firmware -
cisco aironet_1800i -
cisco aironet_1810_firmware -
cisco aironet_1810 -
cisco aironet_1810w_firmware -
cisco aironet_1810w -
cisco aironet_1815_firmware -
cisco aironet_1815 -
cisco aironet_1815i_firmware -
cisco aironet_1815i -
cisco aironet_1832_firmware -
cisco aironet_1832 -
cisco aironet_1842_firmware -
cisco aironet_1842 -
cisco aironet_1852_firmware -
cisco aironet_1852 -
cisco aironet_ap803_firmware -
cisco aironet_ap803 -
cisco aironet_iw3702_firmware -
cisco aironet_iw3702 -
cisco catalyst_9105_firmware -
cisco catalyst_9105 -
cisco catalyst_9105axi_firmware -
cisco catalyst_9105axi -
cisco catalyst_9105axw_firmware -
cisco catalyst_9105axw -
cisco catalyst_9115_firmware -
cisco catalyst_9115 -
cisco catalyst_9115_ap_firmware -
cisco catalyst_9115_ap -
cisco catalyst_9115axe_firmware -
cisco catalyst_9115axe -
cisco catalyst_9115axi_firmware -
cisco catalyst_9115axi -
cisco catalyst_9117_firmware -
cisco catalyst_9117 -
cisco catalyst_9117_ap_firmware -
cisco catalyst_9117_ap -
cisco catalyst_9117axi_firmware -
cisco catalyst_9117axi -
cisco catalyst_9120_firmware -
cisco catalyst_9120 -
cisco catalyst_9120_ap_firmware -
cisco catalyst_9120_ap -
cisco catalyst_9120axe_firmware -
cisco catalyst_9120axe -
cisco catalyst_9120axi_firmware -
cisco catalyst_9120axi -
cisco catalyst_9120axp_firmware -
cisco catalyst_9120axp -
cisco catalyst_9124_firmware -
cisco catalyst_9124 -
cisco catalyst_9124axd_firmware -
cisco catalyst_9124axd -
cisco catalyst_9124axi_firmware -
cisco catalyst_9124axi -
cisco catalyst_9130_firmware -
cisco catalyst_9130 -
cisco catalyst_9130_ap_firmware -
cisco catalyst_9130_ap -
cisco catalyst_9130axe_firmware -
cisco catalyst_9130axe -
cisco catalyst_9130axi_firmware -
cisco catalyst_9130axi -
cisco ip_phone_6861_firmware -
cisco ip_phone_6861 -
cisco ip_phone_8821_firmware -
cisco ip_phone_8821 -
cisco ip_phone_8832_firmware -
cisco ip_phone_8832 -
cisco ip_phone_8861_firmware -
cisco ip_phone_8861 -
cisco ip_phone_8865_firmware -
cisco ip_phone_8865 -
cisco ir829-2lte-ea-ak9_firmware -
cisco ir829-2lte-ea-ak9 -
cisco ir829-2lte-ea-bk9_firmware -
cisco ir829-2lte-ea-bk9 -
cisco ir829-2lte-ea-ek9_firmware -
cisco ir829-2lte-ea-ek9 -
cisco ir829gw-lte-ga-ck9_firmware -
cisco ir829gw-lte-ga-ck9 -
cisco ir829gw-lte-ga-ek9_firmware -
cisco ir829gw-lte-ga-ek9 -
cisco ir829gw-lte-ga-sk9_firmware -
cisco ir829gw-lte-ga-sk9 -
cisco ir829gw-lte-ga-zk9_firmware -
cisco ir829gw-lte-ga-zk9 -
cisco ir829gw-lte-na-ak9_firmware -
cisco ir829gw-lte-na-ak9 -
cisco ir829gw-lte-vz-ak9_firmware -
cisco ir829gw-lte-vz-ak9 -
cisco meraki_gr10_firmware -
cisco meraki_gr10 -
cisco meraki_gr60_firmware -
cisco meraki_gr60 -
cisco meraki_mr12_firmware -
cisco meraki_mr12 -
cisco meraki_mr20_firmware -
cisco meraki_mr20 -
cisco meraki_mr26_firmware -
cisco meraki_mr26 -
cisco meraki_mr30h_firmware -
cisco meraki_mr30h -
cisco meraki_mr32_firmware -
cisco meraki_mr32 -
cisco meraki_mr33_firmware -
cisco meraki_mr33 -
cisco meraki_mr34_firmware -
cisco meraki_mr34 -
cisco meraki_mr36_firmware -
cisco meraki_mr36 -
cisco meraki_mr42_firmware -
cisco meraki_mr42 -
cisco meraki_mr42e_firmware -
cisco meraki_mr42e -
cisco meraki_mr44_firmware -
cisco meraki_mr44 -
cisco meraki_mr45_firmware -
cisco meraki_mr45 -
cisco meraki_mr46_firmware -
cisco meraki_mr46 -
cisco meraki_mr46e_firmware -
cisco meraki_mr46e -
cisco meraki_mr52_firmware -
cisco meraki_mr52 -
cisco meraki_mr53_firmware -
cisco meraki_mr53 -
cisco meraki_mr53e_firmware -
cisco meraki_mr53e -
cisco meraki_mr55_firmware -
cisco meraki_mr55 -
cisco meraki_mr56_firmware -
cisco meraki_mr56 -
cisco meraki_mr62_firmware -
cisco meraki_mr62 -
cisco meraki_mr66_firmware -
cisco meraki_mr66 -
cisco meraki_mr70_firmware -
cisco meraki_mr70 -
cisco meraki_mr72_firmware -
cisco meraki_mr72 -
cisco meraki_mr74_firmware -
cisco meraki_mr74 -
cisco meraki_mr76_firmware -
cisco meraki_mr76 -
cisco meraki_mr84_firmware -
cisco meraki_mr84 -
cisco meraki_mr86_firmware -
cisco meraki_mr86 -
cisco meraki_mx64w_firmware -
cisco meraki_mx64w -
cisco meraki_mx65w_firmware -
cisco meraki_mx65w -
cisco meraki_mx67cw_firmware -
cisco meraki_mx67cw -
cisco meraki_mx67w_firmware -
cisco meraki_mx67w -
cisco meraki_mx68cw_firmware -
cisco meraki_mx68cw -
cisco meraki_mx68w_firmware -
cisco meraki_mx68w -
cisco meraki_z3_firmware -
cisco meraki_z3 -
cisco meraki_z3c_firmware -
cisco meraki_z3c -
cisco webex_board_55_firmware -
cisco webex_board_55 -
cisco webex_board_55s_firmware -
cisco webex_board_55s -
cisco webex_board_70_firmware -
cisco webex_board_70 -
cisco webex_board_70s_firmware -
cisco webex_board_70s -
cisco webex_board_85s_firmware -
cisco webex_board_85s -
cisco webex_dx70_firmware -
cisco webex_dx70 -
cisco webex_dx80_firmware -
cisco webex_dx80 -
cisco webex_room_55_firmware -
cisco webex_room_55 -
cisco webex_room_55_dual_firmware -
cisco webex_room_55_dual -
cisco webex_room_70_firmware -
cisco webex_room_70 -
cisco webex_room_70_dual_firmware -
cisco webex_room_70_dual -
cisco webex_room_70_dual_g2_firmware -
cisco webex_room_70_dual_g2 -
cisco webex_room_70_single_firmware -
cisco webex_room_70_single -
cisco webex_room_70_single_g2_firmware -
cisco webex_room_70_single_g2 -
cisco webex_room_kit_firmware -
cisco webex_room_kit -
cisco webex_room_kit_mini_firmware -
cisco webex_room_kit_mini -
intel ac_8260_firmware -
intel ac_8260 -
intel ac_8265_firmware -
intel ac_8265 -
intel ac_9260_firmware -
intel ac_9260 -
intel ac_9560_firmware -
intel ac_9560 -
intel killer_ac_1550_firmware -
intel killer_ac_1550 -
intel killer_wi-fi_6_ax1650_firmware -
intel killer_wi-fi_6_ax1650 -
intel killer_wi-fi_6e_ax1675_firmware -
intel killer_wi-fi_6e_ax1675 -
intel proset_ac_3165_firmware -
intel proset_ac_3165 -
intel proset_ac_3168_firmware -
intel proset_ac_3168 -
intel proset_ac_8260_firmware -
intel proset_ac_8260 -
intel proset_ac_8265_firmware -
intel proset_ac_8265 -
intel proset_ac_9260_firmware -
intel proset_ac_9260 -
intel proset_ac_9461_firmware -
intel proset_ac_9461 -
intel proset_ac_9462_firmware -
intel proset_ac_9462 -
intel proset_ac_9560_firmware -
intel proset_ac_9560 -
intel proset_wi-fi_6_ax200_firmware -
intel proset_wi-fi_6_ax200 -
intel proset_wi-fi_6_ax201_firmware -
intel proset_wi-fi_6_ax201 -
intel proset_wi-fi_6e_ax210_firmware -
intel proset_wi-fi_6e_ax210 -
intel proset_wireless_7265_\(rev_d\)_firmware -
intel proset_wireless_7265_\(rev_d\) -
intel wi-fi_6_ax200_firmware -
intel wi-fi_6_ax200 -
intel wi-fi_6_ax201_firmware -
intel wi-fi_6_ax201 -
linux linux_kernel *
linux linux_kernel *
linux linux_kernel *
linux linux_kernel *
linux linux_kernel *
linux linux_kernel *
linux linux_kernel *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ieee:ieee_802.11:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA94FAA4-9BBF-402D-8B33-20A5E8AAFC5D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:linux:mac80211:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "20B7EA3B-CCBA-4483-9BDD-DC8ED8689A22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_10:20h2:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E2C378B-1507-4C81-82F6-9F599616845A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_10:1607:*:*:*:*:*:*:*",
              "matchCriteriaId": "E01A4CCA-4C43-46E0-90E6-3E4DBFBACD64",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_10:1803:*:*:*:*:*:*:*",
              "matchCriteriaId": "7CB85C75-4D35-480E-843D-60579EC75FCB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_10:1809:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B8F3DD2-A145-4AF1-8545-CC42892DA3D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_10:1909:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9273B95-20ED-4547-B0A8-95AD15B30372",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_10:2004:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAE74AF3-C559-4645-A6C0-25C3D647AAC8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_7:-:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "C2B1C231-DE19-4B8F-A4AA-5B3A65276E46",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_8.1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E93068DB-549B-45AB-8E5C-00EB5D8B5CF8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_rt_8.1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6CE5198-C498-4672-AF4C-77AB4BE06C5C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_server_2008:-:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "5F422A8C-2C4E-42C8-B420-E0728037E15C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_server_2008:r2:sp1:*:*:*:*:x64:*",
              "matchCriteriaId": "AF07A81D-12E5-4B1D-BFF9-C8D08C32FF4F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_server_2012:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7DF96F8-BA6A-4780-9CA3-F719B3F81074",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_server_2012:-:r2:*:*:*:*:*:*",
              "matchCriteriaId": "5F2558DF-2D1F-46BA-ABF1-08522D33268E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_server_2016:2004:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B60D940-80C7-49F0-8F4E-3F99AC15FA82",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1748-1_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "68C08ECE-4D09-4E57-920B-B8E94E81603A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1748-1:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "83B4B8A7-6CAE-43F7-8DCF-0129392E41A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1750d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D412FC9-835A-4FAB-81B0-4FFB8F48ACA3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1750d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FBC30055-239F-4BB1-B2D1-E5E35F0D8911",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-1_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "F5154A83-2499-4756-9150-8BFD9ACEF583",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-1:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "7CC235C6-63B1-4085-B9AA-47EFB17A144D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2_firmware:-:*:*:*:*:*:eec_m12:*",
              "matchCriteriaId": "8396EACC-A0FA-4A4A-8411-8D9ED40B7F28",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2:-:*:*:*:*:*:eec_m12:*",
              "matchCriteriaId": "54C41A49-87FA-4C98-8321-2808712B2F68",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "F8ED25D1-973F-481A-8550-16508F73D2D2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "35918620-E4C5-4E46-A5A9-63009333667A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2ia_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "27440732-54F0-40DF-9896-88D60ABC568A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2ia:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "FC39A276-532B-428A-83BA-141B626281A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w721-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "93103556-6C4A-4D35-91D1-5CDCDC740655",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w721-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "5DEFC044-1D95-4386-AABB-ADE1099E3F85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w722-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "42759A0F-70C6-41DB-9DF9-2BC05685F678",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w722-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "95662406-0D7D-45B2-95F5-582FA275AC89",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w734-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "A0E9FB66-F577-4744-B51F-3BD25293109F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w734-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "079DA749-0B94-4CCF-A3B1-7669DA213B52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w738-1_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "05D1BC5E-C26E-4E3D-B0DF-014C7DE16F4A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w738-1:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "D96A05C3-1549-47DD-BADA-7872246EBDA0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w748-1_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "2E7375AB-BE32-4879-BB54-CF5EDAB98188",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w748-1:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "0E9E26B8-1539-4E21-AEAA-45095F79382A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w748-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "8BD6E779-AFE3-48C3-95B7-E7BED14BAE0B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w748-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "5AA05DFB-5C02-4822-8D32-406C11ABFFC2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w761-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "0F01F2C2-E968-45EE-BA91-39AEEFC0345C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w761-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "19C73CA1-2F92-4635-8D38-812D6D8ACD89",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_firmware:-:*:*:*:*:*:m12_eec:*",
              "matchCriteriaId": "EA17907A-388A-42E7-ACC6-2F59C72C93F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1:-:*:*:*:*:*:m12_eec:*",
              "matchCriteriaId": "A53A71EB-C346-42CD-AD58-F83F809D0CA9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "F801DE5A-781D-4DDA-9BD3-A9F3A4501D34",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "90E87633-CD6E-439B-9CE8-66A1E414F09D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w778-1_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "742D9262-4329-4F0A-B97E-5FC65786946F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w778-1:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "A04D6C4A-C7DB-4757-8C34-BE6EB7D1BC50",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w778-1_firmware:-:*:*:*:*:*:m12_eec:*",
              "matchCriteriaId": "FC14C45F-FDFB-4AAC-94EC-45860051379F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w778-1:-:*:*:*:*:*:m12_eec:*",
              "matchCriteriaId": "C01E79D8-5F48-4939-BFD6-B363A76769D7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "CEE50FA1-6616-402A-9D86-9725206612C6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "5B907930-CA5C-4160-A3D1-8ACB559C9143",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "9331282F-B426-40DC-869E-F6F7DFE959A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "CAE6D7C0-9AA7-4EE7-B5A9-987BC549442E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2_firmware:-:*:*:*:*:*:sfp:*",
              "matchCriteriaId": "C67D4B91-66EB-490E-B43D-A7E159CC543B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2:-:*:*:*:*:*:sfp:*",
              "matchCriteriaId": "45A6A314-804B-47DC-B35E-804AD89588D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2ia_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "236FBB62-ADAF-4316-BE4A-0F3ACE9B94FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2ia:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "968D60A4-036A-4792-BE8E-88F8B26444DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-1_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "754B93BA-0451-4C09-A124-284A62189D53",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-1:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "85293635-DD43-4651-8605-4F27F228AA91",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "826FB2F4-45B5-4360-B577-11F75A1B67A2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "F3417E19-D7FC-487D-B316-B826DB3CB712",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-2_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "4B7AFF23-828B-4BB4-8A00-0E5C852C95C2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-2:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "9A9E77DB-7B9D-40D0-8947-DFB1B2B7522C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-2_firmware:-:*:*:*:*:*:m12_eec:*",
              "matchCriteriaId": "B66B6DB7-E48C-4758-915E-E4096CC5D68E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-2:-:*:*:*:*:*:m12_eec:*",
              "matchCriteriaId": "69C3A33C-85E1-4157-81F7-39FA271CF8ED",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-2_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "E65FB9EC-A750-44C9-B251-5D8697C29EC2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-2:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "64BD7639-6E6B-4ED7-8AB9-393BC48F10F5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam763-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7948D988-3ED9-49BE-B820-15728DA93D21",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam763-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AAE316D-6BA6-4C3F-9EE1-E23E4CB6FD19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B465A44-EC90-41C6-BD9B-59D3B7E49540",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA96B540-439B-4A1A-9D7D-C45AEFBC7BE6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_firmware:-:*:*:*:*:*:eec:*",
              "matchCriteriaId": "3684DA7E-E49F-42A6-9DA2-FEF6DEDBE9B8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1:-:*:*:*:*:*:eec:*",
              "matchCriteriaId": "43A34072-F6CC-4843-9FEF-E0ECA96BBAEA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_6ghz_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5690A7D8-2B9F-4DBB-84A8-82B1A7C822B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1_6ghz:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA329302-48FE-43FB-A15D-C3BEFB5AE868",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_6ghz_firmware:-:*:*:*:*:*:eec:*",
              "matchCriteriaId": "AA44AF5A-1AAD-4C68-8771-E14BA8ABFBA6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1_6ghz:-:*:*:*:*:*:eec:*",
              "matchCriteriaId": "37055F7B-2F2A-4B80-AC34-CAB0568BC692",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum763-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "534CF2AE-2149-4599-AC43-13EE8048B3EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum763-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C501445F-BDF6-4A0A-85FD-E6BFBF0A3C6F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum766-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E95E358-45E9-40EC-B3A3-D65C4BA42CE7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum766-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EB15599-F795-4D24-A4A6-CD826F6A7A13",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum766-1_6ghz_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "441DF280-FC8C-481F-BDB9-7D757CF5BB72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum766-1_6ghz:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF8A9161-738C-4730-8EC9-6A5C5FDE279D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-100_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "11CE6C04-4994-463F-A456-1D47F2BD793A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "132AD177-3F7F-4CD7-9BD5-EE5A24CE671C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-110_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA7E7D8A-CC58-47F6-9F3F-BE74F1CF27E8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-110:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4E82587-A7A1-4057-896A-F30B9DF7C831",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-120_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89F2DFE1-6E7B-42CC-9814-90F426D14490",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE3EC767-2ECA-44E4-AA03-9E2673A2B2F3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-130_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8197BD27-2AD7-434C-8F64-24B3D6D6E188",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81C15C55-207E-4030-AC2A-B2E3791D92B0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-200_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB011F08-5526-4D49-8100-A874CD265FB5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F81C550-CE6F-4E68-A088-5EC0CEF40600",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-230_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1C3DCD8-9AD7-411B-95DC-B989EEC3E035",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-230:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29B18F4E-4968-493A-BC90-5D8D7F619F39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-235_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AAA44BE-54CE-498B-83EF-D21DF2A57A5E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-235:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "54878C0D-8842-490F-B556-76AF47A65891",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-250_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2A71084-E505-4648-9B5C-C0305DCE91AF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-250:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE97F0AD-8658-476A-8E22-DA67A5FD9F73",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-260_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "60A09137-CF46-420E-9792-BB6E46C5C415",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-260:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A006A8BD-D56E-40C2-ADD2-C11759153808",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-65_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C890ABE-5D64-4D7F-A67B-BC026649E0B3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-65:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B617EA3-E69E-43CA-99D4-86A408C55C90",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-75_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD2A3CCF-E8B5-4E7F-BCE7-DB70E8E72B4B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-75:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EE26D5A-486B-48F3-9C1C-4EE3FD8F0234",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:o-105_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF499EE6-0047-42C0-8360-6A2B3DF51B1B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:o-105:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A31FF47-55EE-451B-ABDD-CE82E8EFBC98",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:o-90_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B9860B5-6CC7-4F29-9514-A469AF6B28F1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:o-90:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "41F9E4B2-63FC-4F53-9C12-7478B7B6AD48",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:w-118_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C9D810C-AA04-4748-80EB-3FB5DE507F89",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:w-118:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BEE861E-2604-42BD-ABAA-DA729F4EBDBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:w-68_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C1EF830-C210-48DB-A3F8-FC706AC5F3C7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:w-68:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F03BB48-C89A-41F6-99DE-12FF95DCD9F2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:1100_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F7999A6-03FE-4C38-9C46-B3221E7B3815",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:1100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC042678-29AA-44F7-BBF0-1D752D25687D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:1100-4p_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81634E2A-FAD5-4B1C-A93E-545870615343",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:1100-4p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA8D5057-138A-42C4-BA35-8077A0A60068",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:1100-8p_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECAB3869-E15B-4ED4-A98C-75DE0DBA8F3F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:1100-8p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED555B12-41F4-4D62-B519-22601FB7AF8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:1101-4p_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "57F5F016-52B5-4A4C-9EE0-B478A98CEC9A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:1101-4p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21B10158-5235-483E-BACD-C407609EA6BE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:1109-2p_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B17C8544-CB4E-407B-BE52-4D42D81BF1BA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:1109-2p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8964F9BA-6E6C-44BF-9A8C-93D081B6678C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:1109-4p_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA214FF2-358E-4291-B803-58A9AC14ABEC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:1109-4p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "51251FE1-67D2-4903-B7D3-E0C727B9A93C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1532_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31FB34B4-235B-4C92-8E9C-DD04136C745F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1532:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CCECB59-4EA8-4FD4-81CB-329EBF7C080C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1542d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2051CA5B-967D-4830-87EB-1756559C1FED",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1542d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5DB7510-2741-464A-8FC9-8419985E330F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1542i_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C72EC048-B84B-4744-BC04-BA8612C79D04",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1542i:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3AE916B2-CAAD-4508-A47E-A7D4D88B077A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1800_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "54BDAFC3-940F-40C4-896E-99B6DABA9E3F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "02F4C00A-D1E2-4B21-A14E-F30B4B818493",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1800i_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9FC7CCB-52D2-4B4D-82AA-759C80E17018",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1800i:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC836B4D-A489-4300-B0A2-EF0B6E01E623",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1810_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB94F02B-C71A-4EAE-B931-30CFA52A890C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1810:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36F923CF-D4EB-48F8-821D-8BB3A69ABB62",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1810w_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF011423-521A-41C4-A403-FF82C2C14874",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1810w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D613A17-FFA9-4FF0-9C2A-AF8ACD59B765",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1815_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E076DDF4-6817-4CFD-B4A3-243D8D755DE3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1815:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8BF9DDB-884D-47B5-A295-8BFA5207C412",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1815i_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "205E19BF-078D-475D-A9F0-4A1604A2D554",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1815i:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "207DC80E-499C-4CA3-8A88-F027DBC64CCF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1832_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72A15C8E-73D8-480D-B5C9-E72E8D4695D0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1832:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "751469E2-91A8-48F1-81A8-AEBF1420EECE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1842_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFAEDA4F-C728-4D60-8661-90429A264E40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1842:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18035D1A-C8D9-4055-A5CA-541711DBA71A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1852_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "883C24F0-99B3-42E0-AC27-6B4B3D4F5FA2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1852:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "80871D9C-43D5-4507-AC36-CDD7CC4A7C86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_ap803_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40F38C35-EFC2-4CF9-AD88-FADC42F0649D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_ap803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5062B18F-F28C-4975-A5A3-45C0EC03F448",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_iw3702_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "338A22C8-5617-45C8-AB3E-5E45341DFE60",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_iw3702:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6214A82C-54A6-48FC-9714-742704BEF1D3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9105_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68410865-70F5-4578-99E4-827DBE0207B1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9105:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F3CCCFE-88CC-4F7B-8958-79CA62516EA9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9105axi_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FF827E8-02BE-42C0-A0CE-B649601847E4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9105axi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "19F93DF4-67DB-4B30-AC22-60C67DF32DB2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9105axw_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C9309C6-EC43-4EB9-BD7A-CBCC581AA58C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9105axw:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "59C77B06-3C22-4092-AAAB-DB099A0B16A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9115_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EEB7E5B-AE32-455A-A351-368FB78E5276",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9115:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4081C532-3B10-4FBF-BB22-5BA17BC6FCF8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9115_ap_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EE86352-EEDB-4890-87B8-025EA970219B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9115_ap:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "56A3430C-9AF7-4604-AD95-FCF2989E9EB0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9115axe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C3DCF4E-081A-4375-A4A0-AAAD8F024114",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9115axe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE4C56A6-E843-498A-A17B-D3D1B01E70E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9115axi_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B69CC2B-CD3A-4BEF-8FF1-9925E460B049",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9115axi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F050F416-44C3-474C-9002-321A33F288D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9117_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "06C11A3E-E431-4923-AEBA-25E3247F19C3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9117:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FCE2220-E2E6-4A17-9F0A-2C927FAB4AA5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9117_ap_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E48E571-AE00-47E2-BABC-849A63DBDCF4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9117_ap:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4AE36E2-E7E9-4E49-8BFF-615DACFC65C1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9117axi_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9A46503-A8BD-4F95-BAB0-2DE5D689DD4F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9117axi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A699C5C-CD03-4263-952F-5074B470F20E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9120_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1EA2B34D-533C-4316-AD59-EA2FCF10B9F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A47C2D6F-8F90-4D74-AFE1-EAE954021F46",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9120_ap_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A8A6B51-5192-4B98-9D94-682290890074",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9120_ap:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C04889F8-3C2A-41AA-9DC9-5A4A4BBE60E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9120axe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D07AB0E3-151D-4D80-A482-41E7A27AE068",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9120axe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "46D41CFE-784B-40EE-9431-8097428E5892",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9120axi_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A99728C-9E6B-4249-BAAA-C080109EFC4A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9120axi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D148A27-85B6-4883-96B5-343C8D32F23B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9120axp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C73A651-932E-43CA-B40F-2F75510AEE36",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9120axp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "735CA950-672C-4787-8910-48AD07868FDE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9124_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A71D9CA-91DF-48DD-AE3D-DED883666A75",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9124:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C11EF240-7599-4138-B7A7-17E4479F5B83",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9124axd_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF43EC0A-AC28-408A-8375-11CE249217A1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9124axd:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E987C945-4D6D-4BE5-B6F0-784B7E821D11",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9124axi_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABA19FD7-047B-43AA-9237-807AAA2E9F7D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9124axi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B434C6D7-F583-4D2B-9275-38A5EC4ECC30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9130_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "19D85A86-1D8B-4006-8BF7-4593B1D7EB70",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1C8E35A-5A9B-4D56-A753-937D5CFB5B19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9130_ap_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "166D74EA-8820-4C78-B43B-FCBC9779FCB7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9130_ap:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "248A3FFC-C33C-4336-A37C-67B6046556E5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9130axe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67C380AE-C888-4AED-80D2-B9AF5EB9EC85",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9130axe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EC1F736-6240-4FA2-9FEC-D8798C9D287C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9130axi_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AA48001-7F56-4155-B70D-5DC41D73DB38",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9130axi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "169E5354-07EA-4639-AB4B-20D2B9DE784C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ip_phone_6861_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD79F5E4-AA2D-40EB-9E59-2FEB4FD49ECD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ip_phone_6861:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C05A7CA6-AD58-45D7-AF32-129E22855D8E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ip_phone_8821_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A138C033-0F4D-41F8-B0FF-CDE9261DA7D9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ip_phone_8821:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36C99E0B-0383-4CB3-B325-EC0F3D57D39D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ip_phone_8832_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2CDAD5D-3702-42EE-AE5A-A08842870EEA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ip_phone_8832:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5EA5C6B-243B-419A-9C60-1CDBD039C1D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ip_phone_8861_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CC9DD95-DC0E-4A47-A0EB-32D551B323CD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ip_phone_8861:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "090EE553-01D5-45F0-87A4-E1167F46EB77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ip_phone_8865_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAAAB671-8EBF-4D9C-9AA5-E3C306CDB931",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ip_phone_8865:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB99B9AB-64B5-4989-9579-A1BB5D2D87EF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829-2lte-ea-ak9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB907B21-237D-4629-964C-408B5AD590E6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829-2lte-ea-ak9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB62C534-29F8-48CA-9D45-42C49CE68577",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829-2lte-ea-bk9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2F956BF-E845-43FF-87A8-EA62DDFB1228",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829-2lte-ea-bk9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B670C5A3-4E19-428F-87D0-C2B12EE2CB92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829-2lte-ea-ek9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4541452E-32E8-451B-B8F3-1118ECCBAE50",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829-2lte-ea-ek9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BF5C3D3-833D-405B-8E1E-ED3BC29CD5E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829gw-lte-ga-ck9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5C512E9-F7A6-492E-BE4B-93858E34CCD9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829gw-lte-ga-ck9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8D39174-298E-4C06-A289-B0C4585B2E99",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829gw-lte-ga-ek9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6041298-45A9-41CB-A644-55D5DC40B5D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829gw-lte-ga-ek9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB259DDC-AB98-405E-A369-49A3B89F48F5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829gw-lte-ga-sk9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A1385AA-FACE-4150-93E8-610A73F90CCB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829gw-lte-ga-sk9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "99B57D05-6702-4026-9E36-0CBEC6BE8001",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829gw-lte-ga-zk9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "715401BE-1E29-4260-9D10-245C6246BE94",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829gw-lte-ga-zk9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC62F7A8-9D57-4703-A7DF-451C2CA75919",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829gw-lte-na-ak9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC762476-57D4-40E8-BE70-2F6861F31EF7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829gw-lte-na-ak9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78F497A3-8153-4524-9E8D-2CFDCF2ADCDE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829gw-lte-vz-ak9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "795A3C41-753D-4590-B71F-37E9DD7DD5D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829gw-lte-vz-ak9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61BD4298-A8D5-4D7C-A9D9-694606042C12",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_gr10_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E9F6455-59CC-4A3B-AFDD-60B5DD1E9ECF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_gr10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5EF406E2-A24B-4D94-B4F7-2186B1D82462",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_gr60_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC624300-4EBB-44B9-9D90-F411368FE60A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_gr60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "33B44092-CC37-4683-920D-8F84C60CCCEF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9005D484-CEF5-4B8D-86B0-6CB5860A157E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03F4DBFC-42FC-44FD-9EDF-4C0C92053E4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr20_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE66B0F4-1211-40A4-BDB3-D8F6C74678AF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B1207B-C065-483D-8AB3-6B9CEC4D3C7C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr26_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "06205774-F85A-42F8-B599-1A529BBFA68B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr26:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "60D19311-A114-455C-9011-004446C80E27",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr30h_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C922D55-E2DC-4970-A381-30F95CEB038B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr30h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "602DA0AF-86EB-4A01-BDE3-43596DEC746A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr32_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B2718D7-1D20-40D5-9E43-7AE1AA7AFCCF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr32:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E011F146-3AB9-446D-ACFD-FE5B021735D3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr33_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFB4CE7A-6FC1-4171-A743-CD8BB14C9864",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr33:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12E670DC-C4D2-4277-A4DD-222D60A7CDB1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr34_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7449719-1071-41B8-BDE9-81ACFBEE5D0F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr34:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "814ADA42-72A9-48D6-B524-5F5BD76F3059",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr36_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25616833-BCF6-4611-A9AB-248F761C5603",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr36:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A66108F-5CED-4D41-8EE9-9479090B31DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr42_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "92DD4610-420C-459B-9B05-85600EF466D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr42:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18E7D194-AA15-43CD-9019-7B286F528773",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr42e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78B15252-5725-4B7B-8DBE-10251EB9C212",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr42e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FB4754D-3B94-42AA-A150-6BDFF42B3270",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr44_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63217CCA-1926-46AD-956E-702A94420D91",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr44:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07E495B6-CA7A-4F58-99A2-550F83E1E020",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B9BC8A2-451A-4BDE-B073-FF39DD9E5D90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4F47740-D0F3-478B-AFC3-51EB3AED34A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr46_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7DC56150-D025-40A9-B350-8E95B62D236C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr46:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27E9718F-E50B-412F-86D7-DA6F39056006",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr46e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914C5C0C-EACD-4A4C-83B2-26AA4EF283D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr46e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6B83072-84F6-43A4-9CC1-32924AFCC737",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr52_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1F09491-2234-4C86-A80C-445B48A9FE78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr52:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5634D1AB-B64D-44D0-A431-FE52E879B4BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr53_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8998B44-D926-46F9-AF3F-02EEF99680A5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr53:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "920CF4B6-9424-48DA-9622-FB0C0510E52F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr53e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "746D2300-CA9A-4C09-9A2B-FCC9DAEC74EC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr53e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EC322AE-6731-41F3-9C59-8CF9622D997A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr55_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "79419F89-0F01-4FD7-9102-ABFAFF3F2424",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr55:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0036877-C975-4AC7-B933-E5BC5E300B44",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr56_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC64210E-A2F8-42DC-AB94-2547A51F63C5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr56:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E37474E5-76DE-4326-A5A8-D8900A8A2F62",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr62_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "089164E3-B852-43BA-8C2C-FEE1C267C58C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr62:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F8F3095-F280-44B0-8BC6-50221247ACE1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr66_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27DA3F64-514B-4DB7-A6B0-6A303F296DC7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr66:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBB99337-4422-46AB-9B79-A96CE207AC28",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr70_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD532656-21FE-4F82-846E-C8CB752B87F1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr70:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37D7E013-920A-4C32-98C1-FBD7C450DD88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr72_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E80D395-C853-41A3-8438-BF880C799A01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr72:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68086DA9-AD50-41DC-B8B5-D9BB0512C6B6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr74_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D8181BA-846A-4D83-9DB9-B915B9EFFD7C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr74:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "366ABABA-D9C5-4D46-9516-7262AA32D4CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr76_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B02C40A8-0294-4C3D-8AC9-8D56AF1D2B4E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr76:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D071FC26-097A-432B-8900-DA02D3116D29",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr84_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D4901FE-B1AE-4CAB-9D91-139737B6E832",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr84:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9543B910-A999-4CEF-B06A-3F1A46784BF0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr86_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC06358C-6F27-4A27-8553-CF138D4214CC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A57AA24E-09E0-4EB6-9580-A68267767119",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mx64w_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "15CD8683-DFB3-45E3-B6E2-92AFD846B0BA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mx64w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1038F5F-020D-41FD-9C3D-F2685F1EA916",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mx65w_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "01AD96C5-1620-4339-94E7-343E1ADAAC4C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mx65w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69A23113-F7E1-4587-A4FF-A4AAB446A69D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mx67cw_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F910935-E534-462D-8045-71C58BDD7285",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mx67cw:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E85585DA-C918-445B-9B44-B2B1A982A1F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mx67w_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B2F5CB3-1AE0-4905-A28B-090FDA56622E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mx67w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2529662-8A54-4DFC-80E7-922CF22DE2F3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mx68cw_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39884334-73AF-4E98-B05A-20FFF82B5DF1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mx68cw:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18E682AA-05AD-483F-915F-A2B2C98233B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mx68w_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85EF67F0-973F-4FD1-8077-CE68D2AB1149",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mx68w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03F9C184-3811-4A26-846D-54ECE7CF939F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_z3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "04CF5026-CC39-48FF-A8F0-8E31A425343E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_z3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB81CFD0-9558-47AB-96E4-CB21C1AA9159",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_z3c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F97974E-3C2B-49DB-A0FA-B5FEE7C98B18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_z3c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6646F004-E0E0-4316-A022-2793C28FBCCC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_board_55_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A0EF95-7CC5-4EE2-A5D8-803195F63F49",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_board_55:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6554B9F-CD89-49B4-B55A-510B1C881C4F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_board_55s_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68546316-D08D-4E0B-BDDE-BF6320B730EB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_board_55s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D0EC6FF-44F6-4033-BDAF-A396C2635D3F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_board_70_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85FDA9FB-BB79-4A60-B825-D68B3719BFE3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_board_70:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A85B502B-2F55-4CA5-9AAA-0CD5BBA45EB7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_board_70s_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5565DF04-82F3-40C7-8E82-44A0DA72398B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_board_70s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "15073B83-81ED-4E98-8521-1320F8120C3F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_board_85s_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CA125CA-2BF9-4F22-8F8B-DC2E09A19E51",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_board_85s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31842684-B05D-4E17-9229-EC6993E78612",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_dx70_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69224767-0E2B-4A85-A7F1-77C6B41668DE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_dx70:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5EEB693F-64A4-46CC-B7AB-8BC0AA84F9E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_dx80_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "53BE3D06-730E-44E2-B3B0-ED29AB5D1BF1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_dx80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C17B385C-68D5-4FF5-AE40-6EDA46E3ACB7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_55_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "90095155-ABC0-43C9-896A-55A797EC2055",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_55:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A983D4D-9E04-45CE-BE3C-9FCD0018837F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_55_dual_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E5ABF29-B908-4A43-B3CC-9145721727A9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_55_dual:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A36CB8A-C74F-46B4-BFCE-523488D33B93",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_70_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA1BD59F-078D-45D2-AC39-C479A4C6E7CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_70:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD45F341-FAD8-4B10-B28C-8697E51C6B61",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_70_dual_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB5631A8-0201-432E-9912-B99D44D757DB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_70_dual:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BB2955F-2C82-4668-8C0B-412BEFE0E09E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_70_dual_g2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A16E007C-A310-474D-8174-EC98FEDDCE76",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_70_dual_g2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40E028E3-2DEB-4015-9BB0-97413DE60A47",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_70_single_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CCE92390-9835-4556-A439-5A6FE108A9AB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_70_single:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B47AE71-CF1B-402B-BB60-645A856A632D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_70_single_g2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BEB8DBF7-428A-42D4-8D52-8FF1329D3A56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_70_single_g2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C05259D-1F6C-440C-BCF4-A87BCC2EEA81",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_kit_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3610C3BC-6994-443F-BD27-0D11293C4079",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_kit:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AD5AD81-0976-483E-AA31-6D53A63A8D90",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_kit_mini_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31D7CC29-6916-4A75-86DE-0BC4FBA3A639",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_kit_mini:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D320D1AC-EAA7-45FD-B932-FC9554934BC1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:ac_8260_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "28B0DBF3-63BB-40EF-9D46-E32D074D73DA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:ac_8260:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5A8F30C-6BB7-4CC6-ADBE-1859DAF66C58",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:ac_8265_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E5ADC21-F308-4CAA-8E98-4E7FDC7EDAAC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:ac_8265:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C08E2F3E-C4B5-4227-A88D-C50E209A12CF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:ac_9260_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2915178-6BB6-45EE-A19D-EDB5B78F2BE2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:ac_9260:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C2795E42-D044-4D48-BCB2-61CC1A3471B1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:ac_9560_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7154EAF0-2E61-4813-B443-C4556137EB4D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:ac_9560:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D382D4A1-C8FD-4B47-B2C4-145232EC8AC5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:killer_ac_1550_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7262E71-08D0-4F5E-8445-1FA0E2243340",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:killer_ac_1550:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA05D5D2-F6C1-4FBB-B334-73F30F108562",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:killer_wi-fi_6_ax1650_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD2249BC-F119-471D-9D71-4690A65A1020",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:killer_wi-fi_6_ax1650:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E239C04-1D6B-4305-9340-BFEC3E54E19A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:killer_wi-fi_6e_ax1675_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CA43945-7F16-4A50-9E25-D91EE4A270F1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:killer_wi-fi_6e_ax1675:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35F09C95-25BD-440A-AD79-8510E54F8DD9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_3165_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "662CE728-C754-465B-A4AC-E63D5115EFC4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_3165:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C527CEB1-3D59-4ACD-B67F-B3919AFCE54C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_3168_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "160C541B-2617-4199-914D-ECE3A0791397",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_3168:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA1FA4A0-728B-4DB1-BA3C-CA80ECBA8624",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_8260_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9C7F70F-207C-4D8C-8C3E-08C7772810F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_8260:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7638C7-6F12-4C10-8B6D-5F866950CA05",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_8265_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA4C0E13-8027-4375-AA26-764DAD7E3C9B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_8265:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CDDDE40-5D30-49AF-91C0-9A4FA7741201",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_9260_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30A4744B-DA96-4614-AA99-9198A6D4C442",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_9260:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09145915-AFD1-4D5D-8178-8571C43A0BA5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_9461_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63756272-F713-4249-91C2-F29A382C63A6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_9461:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1950BF4-323D-4A25-A645-3ED60ED6F3AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_9462_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EFDF863-4FB2-4D21-8744-A82A7C0EAA76",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_9462:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "28157739-A073-4B01-B308-470841344A2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_9560_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "42D55365-A759-4F72-B85D-5C13710F2AF6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_9560:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "52B5EF48-BA3E-470C-9C68-12CEF8EFF045",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_wi-fi_6_ax200_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8531052-3602-4309-93A9-CA7020EF95F4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_wi-fi_6_ax200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB9FC918-AC9F-4C15-8404-1C2E8DC506A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_wi-fi_6_ax201_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB831D03-30CD-4218-9E69-13FC12115805",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_wi-fi_6_ax201:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5A7944D-2BB4-47A9-A2F5-AB68A9FC8C70",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_wi-fi_6e_ax210_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "049297F7-84C0-4AD0-8806-AA41AC02CEAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_wi-fi_6e_ax210:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77EADB2D-F10B-40A9-A938-A89EE0FEFF60",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_wireless_7265_\\(rev_d\\)_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2C67C7D-DA10-47A7-8407-5624981DFBE8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_wireless_7265_\\(rev_d\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BFF8901-DEFF-4D08-8692-571682DE8582",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:wi-fi_6_ax200_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55FD8273-3968-4A85-A4FF-00CCE3B89C25",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:wi-fi_6_ax200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D653F9C-5B2E-400F-8F50-BFE466F08F0E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:wi-fi_6_ax201_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2DF0C27-886C-48F8-83DA-85BE0F239DD3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:wi-fi_6_ax201:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0433774-9479-4A01-B697-1379AEA223C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "52BB9046-E47D-480A-93D2-DB0F76574E02",
              "versionEndExcluding": "4.4.271",
              "versionStartIncluding": "4.4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C01BF34A-CD21-4B2F-9877-C89B8202B09A",
              "versionEndExcluding": "4.9.271",
              "versionStartIncluding": "4.9.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "970E3D3C-8829-4599-95A7-AC63136CE48E",
              "versionEndExcluding": "4.14.235",
              "versionStartIncluding": "4.14",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC7D3563-5878-403A-9BB7-6C44E6FE10A0",
              "versionEndExcluding": "4.19.193",
              "versionStartIncluding": "4.19",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "01D49B11-5E8A-427F-B9BE-8A5174DEDD65",
              "versionEndExcluding": "5.4.124",
              "versionStartIncluding": "5.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B39B1E70-2AF7-4482-9ADF-45A1C04A4BC3",
              "versionEndExcluding": "5.10.42",
              "versionStartIncluding": "5.10",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B1CFA77-6B5E-430C-AC49-3B3508F2D903",
              "versionEndExcluding": "5.12.9",
              "versionStartIncluding": "5.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn\u0027t require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary can abuse this to inject arbitrary network packets."
    },
    {
      "lang": "es",
      "value": "El est\u00e1ndar 802.11 que sustenta a Wi-Fi Protected Access (WPA, WPA2, y WPA3) y Wired Equivalent Privacy (WEP) no requiere que el flag A-MSDU en el campo de encabezado QoS de texto plano est\u00e9 autenticada. Contra dispositivos que admiten la recepci\u00f3n de tramas A-MSDU que no son SSP (que es obligatorio como parte de 802.11n), un adversario puede abusar de esto para inyectar paquetes de red arbitrarios"
    }
  ],
  "id": "CVE-2020-24588",
  "lastModified": "2024-11-21T05:15:05.740",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 2.9,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 5.5,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "baseSeverity": "LOW",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-11T20:15:08.613",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/05/11/12"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2021/06/msg00019.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2021/06/msg00020.html"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://lists.debian.org/debian-lts-announce/2023/04/msg00002.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.fragattacks.com"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00473.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/05/11/12"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2021/06/msg00019.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2021/06/msg00020.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://lists.debian.org/debian-lts-announce/2023/04/msg00002.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://www.fragattacks.com"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00473.html"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-327"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-12-13 16:15
Modified
2025-01-14 11:15
Summary
Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data.
Impacted products
Vendor Product Version
siemens ruggedcom_rm1224_lte\(4g\)_eu_firmware *
siemens ruggedcom_rm1224_lte\(4g\)_eu -
siemens ruggedcom_rm1224_lte\(4g\)_nam_firmware *
siemens ruggedcom_rm1224_lte\(4g\)_nam -
siemens scalance_m804pb_firmware *
siemens scalance_m804pb -
siemens scalance_m812-1_adsl-router_firmware *
siemens scalance_m812-1_adsl-router -
siemens scalance_m816-1_adsl-router_firmware *
siemens scalance_m816-1_adsl-router -
siemens scalance_m826-2_shdsl-router_firmware *
siemens scalance_m826-2_shdsl-router -
siemens scalance_m874-2_firmware *
siemens scalance_m874-2 -
siemens scalance_m874-3_firmware *
siemens scalance_m874-3 -
siemens scalance_m876-3_firmware *
siemens scalance_m876-3 -
siemens scalance_m876-4_firmware *
siemens scalance_m876-4 -
siemens scalance_mum853-1_firmware *
siemens scalance_mum853-1 -
siemens scalance_mum856-1_firmware *
siemens scalance_mum856-1 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_s615_eec_firmware *
siemens scalance_s615_eec -
siemens scalance_sc622-2c_firmware *
siemens scalance_sc622-2c -
siemens scalance_sc626-2c_firmware *
siemens scalance_sc626-2c -
siemens scalance_sc632-2c_firmware *
siemens scalance_sc632-2c -
siemens scalance_sc636-2c_firmware *
siemens scalance_sc636-2c -
siemens scalance_sc642-2c_firmware *
siemens scalance_sc642-2c -
siemens scalance_sc646-2c_firmware *
siemens scalance_sc646-2c -
siemens scalance_w721-1_rj45_firmware *
siemens scalance_w721-1_rj45 -
siemens scalance_w722-1_rj45_firmware *
siemens scalance_w722-1_rj45 -
siemens scalance_w734-1_rj45_firmware *
siemens scalance_w734-1_rj45 -
siemens scalance_w738-1_m12_firmware *
siemens scalance_w738-1_m12 -
siemens scalance_w748-1_m12_firmware *
siemens scalance_w748-1_m12 -
siemens scalance_w761-1_rj45_firmware -
siemens scalance_w761-1_rj45 -
siemens scalance_w774-1_m12_eec_firmware -
siemens scalance_w774-1_m12_eec -
siemens scalance_w774-1_m12_rj45_firmware -
siemens scalance_w774-1_m12_rj45 -
siemens scalance_w774-1_rj45_firmware -
siemens scalance_w774-1_rj45 -
siemens scalance_w778-1_m12_firmware -
siemens scalance_w778-1_m12 -
siemens scalance_w778-1_m12_eec_firmware -
siemens scalance_w778-1_m12_eec -
siemens scalance_w786-1_rj45_firmware -
siemens scalance_w786-1_rj45 -
siemens scalance_w786-2_rj45_firmware -
siemens scalance_w786-2_rj45 -
siemens scalance_w786-2_sfp_firmware -
siemens scalance_w786-2_sfp -
siemens scalance_w786-2ia_rj45_firmware -
siemens scalance_w786-2ia_rj45 -
siemens scalance_w788-1_m12_firmware -
siemens scalance_w788-1_m12 -
siemens scalance_w788-1_rj45_firmware -
siemens scalance_w788-1_rj45 -
siemens scalance_w788-2_m12_firmware -
siemens scalance_w788-2_m12 -
siemens scalance_w788-2_m12_eec_firmware -
siemens scalance_w788-2_m12_eec -
siemens scalance_w1748-1_m12_firmware -
siemens scalance_w1748-1_m12 -
siemens scalance_w1788-1_m12_firmware -
siemens scalance_w1788-1_m12 -
siemens scalance_w1788-2_eec_m12_firmware -
siemens scalance_w1788-2_eec_m12 -
siemens scalance_w1788-2_m12_firmware -
siemens scalance_w1788-2_m12 -
siemens scalance_w1788-2ia_m12_firmware -
siemens scalance_w1788-2ia_m12 -
siemens scalance_wam763-1_firmware -
siemens scalance_wam763-1 -
siemens scalance_wam766-1_firmware -
siemens scalance_wam766-1 -
siemens scalance_wam766-1_6ghz_firmware -
siemens scalance_wam766-1_6ghz -
siemens scalance_wam766-1_ecc_firmware -
siemens scalance_wam766-1_ecc -
siemens scalance_wum763-1_firmware -
siemens scalance_wum763-1 -
siemens scalance_wum766-1_firmware -
siemens scalance_wum766-1 -
siemens scalance_wum766-1_6ghz_firmware -
siemens scalance_wum766-1_6ghz -
siemens scalance_xb205-3_firmware -
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware -
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware -
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware -
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware -
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware -
siemens scalance_xb216 -
siemens scalance_xc206-2_firmware -
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe_firmware -
siemens scalance_xc206-2g_poe -
siemens scalance_xc206-2g_poe_eec_firmware -
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_firmware -
siemens scalance_xc206-2sfp -
siemens scalance_xc206-2sfp_eec_firmware -
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware -
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_eec_firmware -
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware -
siemens scalance_xc208 -
siemens scalance_xc208_eec_firmware -
siemens scalance_xc208_eec -
siemens scalance_xc208_poe_firmware -
siemens scalance_xc208_poe -
siemens scalance_xc216_firmware -
siemens scalance_xc216 -
siemens scalance_xc216-3g_poe_firmware -
siemens scalance_xc216-3g_poe -
siemens scalance_xc216-4c_firmware -
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware -
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_eec_firmware -
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware -
siemens scalance_xc216eec -
siemens scalance_xc224_firmware -
siemens scalance_xc224 -
siemens scalance_xc224-4c_g_firmware -
siemens scalance_xc224-4c_g -
siemens scalance_xc224-4c_g_eec_firmware -
siemens scalance_xc224-4c_g_eec -
siemens scalance_xf204_firmware -
siemens scalance_xf204 -
siemens scalance_xf204_dna_firmware -
siemens scalance_xf204_dna -
siemens scalance_xf204-2ba_firmware -
siemens scalance_xf204-2ba -
siemens scalance_xf204-2bca_dna_firmware -
siemens scalance_xf204-2bca_dna -
siemens scalance_xm408-4c_firmware -
siemens scalance_xm408-4c -
siemens scalance_xm408-8c_firmware -
siemens scalance_xm408-8c -
siemens scalance_xm416-4c_firmware -
siemens scalance_xm416-4c -
siemens scalance_xp208_firmware -
siemens scalance_xp208 -
siemens scalance_xp208eec_firmware -
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware -
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware -
siemens scalance_xp216 -
siemens scalance_xp216eec_firmware -
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware -
siemens scalance_xp216poe_eec -
siemens scalance_xr324wg_firmware -
siemens scalance_xr324wg -
siemens scalance_xr326-2c_firmware -
siemens scalance_xr326-2c -
siemens scalance_xr326-2c_poe_firmware -
siemens scalance_xr326-2c_poe -
siemens scalance_xr328-4c_wg_firmware -
siemens scalance_xr328-4c_wg -
siemens scalance_xr524-8c_firmware -
siemens scalance_xr524-8c -
siemens scalance_xr526-8c_firmware -
siemens scalance_xr526-8c -
siemens scalance_xr528-6m_firmware -
siemens scalance_xr528-6m -
siemens scalance_xr552-12m_firmware -
siemens scalance_xr552-12m -
siemens siplus_net_scalance_xc206-2_firmware -
siemens siplus_net_scalance_xc206-2 -
siemens siplus_net_scalance_xc206-2sfp_firmware -
siemens siplus_net_scalance_xc206-2sfp -
siemens siplus_net_scalance_xc208_firmware -
siemens siplus_net_scalance_xc208 -
siemens siplus_net_scalance_xc216-4c_firmware -
siemens siplus_net_scalance_xc216-4c -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\(4g\\)_eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DFAA9A1-FE88-4F1C-92F3-2D4DCE3CC67E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rm1224_lte\\(4g\\)_eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03D8CF59-D9D4-4C50-A6E6-D6B5BDB31AEC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\(4g\\)_nam_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6ADBD53E-B345-4557-B595-23A17E56705D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rm1224_lte\\(4g\\)_nam:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "400ACE99-AF15-4C20-9A6D-F8584DA5C7CE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m804pb_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21328784-AF25-4714-B533-7BEF16986E19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6EBA42A-93FF-4883-8626-EF78D38374D3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m812-1_adsl-router_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "63CB925E-301E-4ABA-A8D5-8089A7F2874D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m812-1_adsl-router:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "451B1162-CCDE-4658-86B7-DF98468B2721",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m816-1_adsl-router_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FDD3DB2-8ACC-4039-A134-458771460501",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m816-1_adsl-router:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "80BE81AD-F440-4009-A33F-DBE957C3CDD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m826-2_shdsl-router_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "22188289-5FC8-418D-9077-B42F05A2468F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m826-2_shdsl-router:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39951670-CF88-460C-B1D5-6DCFBC7F573D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m874-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A3C8086-4B67-4609-A239-8A606CBC5285",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m874-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C933ED27-2206-4734-8EB8-6A6431D1FBF1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m874-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C186B14-DCBF-43CD-BE7D-2ED72EF6E3C3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m874-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3258DC7-0461-4C65-8292-85C9965EA83D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m876-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEDC7F0A-7AD7-464E-83E2-B433EF076C0C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m876-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD221BA9-3448-49E4-B3A3-D88B939785AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m876-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA2495A6-4AE8-4FD6-8B86-378DD542C59B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m876-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "94E4CCE9-71F7-4960-B7DE-5298EFB7C619",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_mum853-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F71C564-F2D8-4141-A009-C73144973491",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_mum853-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F56875A-B2B3-471F-ADAC-574C55E1D86A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_mum856-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B363B81A-2F6D-4720-83A1-44604125B8CE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_mum856-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "17BEBCAB-D640-4F6D-9579-4A54C76D80F8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EF65A06-2222-47D2-83B5-4C61E6D8731E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "065E9A4C-2F3B-4C13-976C-E8DF4630580F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA5D94EA-C407-446F-B98F-F647ACBBA010",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5984E86-2A83-4927-80E1-62FC75E72C48",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc622-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50FEE5FA-B141-4E5F-8673-363089262530",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc626-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F3AAA53-4DC8-49B7-B77C-DC6759652461",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc626-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EAC3EE40-4398-4337-B40E-8AACDF225BBF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8020D902-3489-4898-A676-C262B0DB4653",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc632-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A79836B-5EC1-40AF-8A57-9657EF6758E5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FDFD39B-1E20-4735-833B-9A89B171C560",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc636-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCB9BD17-7F1F-42E9-831F-EB907F9BC214",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5ADD89C-22C7-45CA-AE2D-1BF63CE6CF97",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc642-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10C7D54A-27B4-4195-8131-DD5380472A75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "656082A8-8160-4A1A-967B-F7CC27A218D5",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc646-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E54AF1E6-0E52-447C-8946-18716D30EBE2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w721-1_rj45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64D0557E-2677-496D-ADC6-A43164499217",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w721-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DABF73D6-D438-4417-A626-A73E84CA7355",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w722-1_rj45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BDC42FA-2A49-4494-A678-DCAA363E41B7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w722-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBB3AC0B-8A73-420D-A5BE-B5FB105BD289",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w734-1_rj45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A20C962-DC09-4B5A-873F-4CEAA00C41BA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w734-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50B58BD7-3B5E-458E-BEB7-EFDC0336454A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w738-1_m12_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD191B35-A96B-4C62-8BBD-F997C658D5D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w738-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8600D53-1137-40C0-9D6E-A9BC87B3697B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w748-1_m12_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "97BE6180-2176-40B2-B73B-8E988728A459",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w748-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F67ECC31-7B5A-4716-B9CF-B3A2AB7D3809",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w761-1_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B763B9EF-C23C-4724-8F7B-54EA8295BF8B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w761-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37A6BD90-9E5B-4828-8B05-E7D18C2D7694",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_m12_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5BAD55E-A127-49CF-A34A-B86A09BB6781",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1_m12_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7F9461B-4089-48E6-AA46-72D53BFC1A2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_m12_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E6DB76A-1F8C-40A7-AD9E-7448FB864529",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1_m12_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B13194C7-B3C0-486B-9BB0-7380271AC51C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FDE9C73-A7AF-4994-8D5C-F49B22F65454",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C775EE0-4F09-40DB-83B4-010A4DA395A2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w778-1_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "412B05DB-DA86-488E-9818-BEA7358DA7E1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w778-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE028852-E293-41D4-8EA9-E7F4C187F383",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w778-1_m12_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12D1DBB7-76E7-4D73-A07A-700A6B44E27F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w778-1_m12_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F5D048A-D906-4AC2-B897-086916DB928C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-1_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F0C250C-5A86-4117-85DD-A86BC3CDBD49",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "96137F44-A487-4A37-BF35-0466F6B947EC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7670B731-0044-4D39-ACE9-4A8C70D481B8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "64140D18-45F0-4745-B204-D1904ECB7F2E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2_sfp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "504C7CBD-FD95-46B6-9AF2-FF9282C2C2F2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2_sfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "301FEDD1-21C9-42B4-ADAF-E97F7387F5E2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2ia_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2BC32A8-3617-48DB-BC07-C683F55B94CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2ia_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8598E40-4F23-47A6-B4B7-EEF168E0B528",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-1_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9B7DADC-7877-4668-B4E9-45B7A8CCB06A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49D960F5-A0D0-4410-A4FD-F0435B3DE3F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-1_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C90F8DD9-064C-4ECE-9A9D-9F1C0274B410",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4706F058-B8C7-4A23-9C12-10D2CC0C3319",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-2_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3093E54-0D81-40E1-92F0-B15F4B03B97C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-2_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C095E360-53A0-4A9A-AD28-841CAE9B4862",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-2_m12_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FFC245C-6185-4477-B1CB-0AF9AFE7B6D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-2_m12_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E7B6FFF-7562-47DD-AEE0-36C119A178AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1748-1_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B4646E-7506-4A23-8833-2503192AD197",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1748-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2353650-D295-4A89-9CF2-50984BE0DD19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-1_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9804602-E66C-4E83-9995-D392ECBE1ABD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "408600B8-762D-43C9-A259-7163FA9DB788",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2_eec_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35B4452A-63DA-43ED-A987-FCD0F28D8F49",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2_eec_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8AE6F9AD-37DB-4067-8BB4-10CDD3AA8E23",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "70FF8CDC-EB85-4CE6-B2C7-ED138F9B9785",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8AA449C-52AE-4286-8BD2-C1A54A1AC64E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2ia_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "985AF207-0160-44FE-985D-0FA3A9248E87",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2ia_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9491822-56EE-4065-B199-040BEE283ED0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam763-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7948D988-3ED9-49BE-B820-15728DA93D21",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam763-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AAE316D-6BA6-4C3F-9EE1-E23E4CB6FD19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B465A44-EC90-41C6-BD9B-59D3B7E49540",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA96B540-439B-4A1A-9D7D-C45AEFBC7BE6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_6ghz_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5690A7D8-2B9F-4DBB-84A8-82B1A7C822B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1_6ghz:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA329302-48FE-43FB-A15D-C3BEFB5AE868",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_ecc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "88B6E0DF-40E8-404A-97D4-24C249CB9947",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1_ecc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "87BF5178-0503-43DB-97C7-0C7852636FD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum763-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "534CF2AE-2149-4599-AC43-13EE8048B3EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum763-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C501445F-BDF6-4A0A-85FD-E6BFBF0A3C6F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum766-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E95E358-45E9-40EC-B3A3-D65C4BA42CE7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum766-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EB15599-F795-4D24-A4A6-CD826F6A7A13",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum766-1_6ghz_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "441DF280-FC8C-481F-BDB9-7D757CF5BB72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum766-1_6ghz:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF8A9161-738C-4730-8EC9-6A5C5FDE279D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "741BF248-4BDF-4D25-8A0F-3584B8529051",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9F9F101-6042-4D11-98CE-16A996023B38",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "126369BE-5503-4F85-8652-AC03F2EE6D14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18DC9125-FC41-4BAB-9638-C42DEF40235B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb208_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D8B4FF5-6C20-41F5-A551-272B5FD84A26",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD92140A-AC7A-463D-99DC-E744A7192532",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B3F6874-3972-435C-89FB-66C9E2729699",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb216_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB116F11-7866-4E74-9037-549462578EA5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D83AF5-9770-43A9-91AE-15EB97A1ACCC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6091005D-A614-4304-94FE-2122D9BF5E00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D32A16B-7D10-4CC8-8E2D-B7B92FBE1E57",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "641699CC-03A4-4DF0-8B1F-EEB658C02E71",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A7D7D3-709A-4872-AC80-FC8EC4915A30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "804E37AB-9EE4-4931-A874-4FBD427252D1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C6E4046-3278-4FDF-84AF-B285905AFF17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC286693-55D6-4949-8164-262EB6C022C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "51F537D2-489A-420F-8167-C527E2ED506A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC7B235D-0141-46E5-9057-2203555AE58A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4AD0884E-98F8-4A67-BD85-AF92674B314C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED2CF432-441D-4707-8E4C-43AC51DF9422",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14FE1E7A-1E4A-4B11-983E-DC39859EAFF0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C54CBCC9-F19D-4993-9D32-8C8778B00E29",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208_poe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C84F8238-18F5-4027-8727-5D999BB1650E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CD4E4B5-7F1E-4005-ACEF-7BD13623EBF9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCEBB0C5-16B2-4B3E-818F-E503A72D785B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-3g_poe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07910A99-B456-4E99-955F-4B08D100E3A2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-3g_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00518DEB-EE44-45AD-AA53-0BBEAF6D3996",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB57F678-CC82-4DF5-9A04-1C85D1B7F521",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25CA5DE7-8645-4DFA-8C2A-C23405FEBAAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78645734-50C1-4331-9FC4-AC8A8679B6AF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "163DDB2C-19D7-4A13-86D5-1258E3F66C3D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "323CEAEA-8122-43A5-BB87-97C7133FF510",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5196C590-7B02-4A9B-BDAC-0770E26498E1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BE498F8-A9D8-4A92-90CE-21BA30234947",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "333852F5-7EF8-41B8-A58D-CE8F00D525A1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4710338E-9449-4AF3-9C91-E7AF9549CA69",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9615F05-CD89-4CCB-B1FB-A76D067BCB15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29A2F221-42ED-4DC3-8D61-89D3545737FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE918926-B0F2-40E9-9453-6F0857543CF1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE51B288-0592-4360-BB83-27675DA261FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F1AE867-67B4-4871-BF56-88017533A737",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204_dna_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81A70627-A17F-4C66-B154-D1D585EFB08B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204_dna:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "70D62F13-AD59-435E-851A-87A0A6E2FA3B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55E6E20A-865B-4FC6-9727-5CB27707177A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EB2D91E-3DB2-4B89-8911-5323B2F0513F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2bca_dna_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE62F317-6D74-4FAA-A12E-BFB229AD4AEC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2bca_dna:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65F65152-F42B-4EDC-90A9-171023690CDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E69D335F-FBC9-4567-B68D-F616F761A609",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AA81823-013F-4990-B62D-86C404F04BCB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D36EF679-0355-4CEA-A247-EA266FEA0843",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7096DBA5-95BB-44D7-B7CA-B1845C87F70E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3850AC0-AC32-480D-B1BB-DE2E1E5A57E4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9102A41-5812-4014-BC07-E571E815ED49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E5FD7D0-770C-4D8E-AAC7-F0F752C57A45",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A75B5F6-B974-463C-BDB7-970982085EE7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B313A4C-D3E7-4964-BA51-3401546B36C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA9F6F24-B1C5-4808-A481-13B1312D01F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6E888EA-73A7-42B8-A617-621CF192F2A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "05515A80-76E4-44D5-B78E-33B07D505451",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4154797A-208E-426F-817A-050B4B96128B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12512EC4-FB7D-420F-9A8A-547562BE1B49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F9FCBCD-5546-4EAB-874A-64B3925287AC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324wg_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50D00EA1-F24F-42C4-9A6B-48E1A572588B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E767C461-8FA6-4700-98CB-734AFD309140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr326-2c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1EBDED3-F7E0-4DC3-A477-1DD76106BBB8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr326-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1CFB380-CE6A-45FF-AF85-F145494D696B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr326-2c_poe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "11593BD9-68E1-4860-A987-73366C06872D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr326-2c_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "91A86897-0140-476D-BBD2-410E08279B70",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5495FD4E-3A57-4C49-99EA-6085DF1D1DBB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5B7DEDC-66BD-4701-BBDD-16273263ADC9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D8E2D30-DDA9-4C2E-A06A-428A42AEF849",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31168EC3-8073-4DB0-8E92-5E0A2780887F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49EA2944-E702-4BF4-B6AD-BF6A737EA866",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4B71459-24D4-4351-BF66-2BB246FF279E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A806691-3F4B-46AA-9718-2F6BF0FD3D7A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_xc206-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C763CFC2-4001-4200-B975-FF1B26F157CE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_xc206-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3296F8-1159-4A4F-B106-43216C55737D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_xc206-2sfp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF228885-3028-4525-A320-CE62818567CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "66C7B087-CAE4-42BC-AAA3-99976870539F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_xc208_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BB380B7-A3BF-4D5C-9113-FC07E3C807DB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_xc208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AC043E2-1DAB-4CF2-B024-88BC6B6B0C89",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_xc216-4c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C35A45E9-BDC8-496A-9E00-6726A99434E0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_xc216-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D52CD11-7965-4864-88BB-76CD31977266",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data."
    },
    {
      "lang": "es",
      "value": "Los dispositivos afectados no verifican correctamente el tama\u00f1o del bloque TFTP. Esto podr\u00eda permitir que un atacante autenticado lea desde un b\u00fafer no inicializado que potencialmente contenga datos previamente asignados."
    }
  ],
  "id": "CVE-2022-46143",
  "lastModified": "2025-01-14T11:15:11.840",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 2.7,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 1.4,
        "source": "productcert@siemens.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 2.7,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 5.1,
          "baseSeverity": "MEDIUM",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "HIGH",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "NONE",
          "vulnerableSystemConfidentiality": "LOW",
          "vulnerableSystemIntegrity": "NONE"
        },
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-12-13T16:15:25.137",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1284"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1284"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-12-13 16:15
Modified
2025-01-14 11:15
Summary
Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords.
Impacted products
Vendor Product Version
siemens ruggedcom_rm1224_lte\(4g\)_eu_firmware *
siemens ruggedcom_rm1224_lte\(4g\)_eu -
siemens ruggedcom_rm1224_lte\(4g\)_nam_firmware *
siemens ruggedcom_rm1224_lte\(4g\)_nam -
siemens scalance_m804pb_firmware *
siemens scalance_m804pb -
siemens scalance_m812-1_adsl-router_firmware *
siemens scalance_m812-1_adsl-router -
siemens scalance_m816-1_adsl-router_firmware *
siemens scalance_m816-1_adsl-router -
siemens scalance_m826-2_shdsl-router_firmware *
siemens scalance_m826-2_shdsl-router -
siemens scalance_m874-2_firmware *
siemens scalance_m874-2 -
siemens scalance_m874-3_firmware *
siemens scalance_m874-3 -
siemens scalance_m876-3_firmware *
siemens scalance_m876-3 -
siemens scalance_m876-4_firmware *
siemens scalance_m876-4 -
siemens scalance_mum853-1_firmware *
siemens scalance_mum853-1 -
siemens scalance_mum856-1_firmware *
siemens scalance_mum856-1 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_s615_eec_firmware *
siemens scalance_s615_eec -
siemens scalance_sc622-2c_firmware *
siemens scalance_sc622-2c -
siemens scalance_sc626-2c_firmware *
siemens scalance_sc626-2c -
siemens scalance_sc632-2c_firmware *
siemens scalance_sc632-2c -
siemens scalance_sc636-2c_firmware *
siemens scalance_sc636-2c -
siemens scalance_sc642-2c_firmware *
siemens scalance_sc642-2c -
siemens scalance_sc646-2c_firmware *
siemens scalance_sc646-2c -
siemens scalance_w721-1_rj45_firmware *
siemens scalance_w721-1_rj45 -
siemens scalance_w722-1_rj45_firmware *
siemens scalance_w722-1_rj45 -
siemens scalance_w734-1_rj45_firmware *
siemens scalance_w734-1_rj45 -
siemens scalance_w738-1_m12_firmware *
siemens scalance_w738-1_m12 -
siemens scalance_w748-1_m12_firmware *
siemens scalance_w748-1_m12 -
siemens scalance_w761-1_rj45_firmware -
siemens scalance_w761-1_rj45 -
siemens scalance_w774-1_m12_eec_firmware -
siemens scalance_w774-1_m12_eec -
siemens scalance_w774-1_m12_rj45_firmware -
siemens scalance_w774-1_m12_rj45 -
siemens scalance_w774-1_rj45_firmware -
siemens scalance_w774-1_rj45 -
siemens scalance_w778-1_m12_firmware -
siemens scalance_w778-1_m12 -
siemens scalance_w778-1_m12_eec_firmware -
siemens scalance_w778-1_m12_eec -
siemens scalance_w786-1_rj45_firmware -
siemens scalance_w786-1_rj45 -
siemens scalance_w786-2_rj45_firmware -
siemens scalance_w786-2_rj45 -
siemens scalance_w786-2_sfp_firmware -
siemens scalance_w786-2_sfp -
siemens scalance_w786-2ia_rj45_firmware -
siemens scalance_w786-2ia_rj45 -
siemens scalance_w788-1_m12_firmware -
siemens scalance_w788-1_m12 -
siemens scalance_w788-1_rj45_firmware -
siemens scalance_w788-1_rj45 -
siemens scalance_w788-2_m12_firmware -
siemens scalance_w788-2_m12 -
siemens scalance_w788-2_m12_eec_firmware -
siemens scalance_w788-2_m12_eec -
siemens scalance_w1748-1_m12_firmware -
siemens scalance_w1748-1_m12 -
siemens scalance_w1788-1_m12_firmware -
siemens scalance_w1788-1_m12 -
siemens scalance_w1788-2_eec_m12_firmware -
siemens scalance_w1788-2_eec_m12 -
siemens scalance_w1788-2_m12_firmware -
siemens scalance_w1788-2_m12 -
siemens scalance_w1788-2ia_m12_firmware -
siemens scalance_w1788-2ia_m12 -
siemens scalance_wam763-1_firmware -
siemens scalance_wam763-1 -
siemens scalance_wam766-1_firmware -
siemens scalance_wam766-1 -
siemens scalance_wam766-1_6ghz_firmware -
siemens scalance_wam766-1_6ghz -
siemens scalance_wam766-1_ecc_firmware -
siemens scalance_wam766-1_ecc -
siemens scalance_wum763-1_firmware -
siemens scalance_wum763-1 -
siemens scalance_wum766-1_firmware -
siemens scalance_wum766-1 -
siemens scalance_wum766-1_6ghz_firmware -
siemens scalance_wum766-1_6ghz -
siemens scalance_xb205-3_firmware -
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware -
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware -
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware -
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware -
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware -
siemens scalance_xb216 -
siemens scalance_xc206-2_firmware -
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe_firmware -
siemens scalance_xc206-2g_poe -
siemens scalance_xc206-2g_poe_eec_firmware -
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_firmware -
siemens scalance_xc206-2sfp -
siemens scalance_xc206-2sfp_eec_firmware -
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware -
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_eec_firmware -
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware -
siemens scalance_xc208 -
siemens scalance_xc208_eec_firmware -
siemens scalance_xc208_eec -
siemens scalance_xc208_poe_firmware -
siemens scalance_xc208_poe -
siemens scalance_xc216_firmware -
siemens scalance_xc216 -
siemens scalance_xc216-3g_poe_firmware -
siemens scalance_xc216-3g_poe -
siemens scalance_xc216-4c_firmware -
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware -
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_eec_firmware -
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware -
siemens scalance_xc216eec -
siemens scalance_xc224_firmware -
siemens scalance_xc224 -
siemens scalance_xc224-4c_g_firmware -
siemens scalance_xc224-4c_g -
siemens scalance_xc224-4c_g_eec_firmware -
siemens scalance_xc224-4c_g_eec -
siemens scalance_xf204_firmware -
siemens scalance_xf204 -
siemens scalance_xf204_dna_firmware -
siemens scalance_xf204_dna -
siemens scalance_xf204-2ba_firmware -
siemens scalance_xf204-2ba -
siemens scalance_xf204-2bca_dna_firmware -
siemens scalance_xf204-2bca_dna -
siemens scalance_xm408-4c_firmware -
siemens scalance_xm408-4c -
siemens scalance_xm408-8c_firmware -
siemens scalance_xm408-8c -
siemens scalance_xm416-4c_firmware -
siemens scalance_xm416-4c -
siemens scalance_xp208_firmware -
siemens scalance_xp208 -
siemens scalance_xp208eec_firmware -
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware -
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware -
siemens scalance_xp216 -
siemens scalance_xp216eec_firmware -
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware -
siemens scalance_xp216poe_eec -
siemens scalance_xr324wg_firmware -
siemens scalance_xr324wg -
siemens scalance_xr326-2c_firmware -
siemens scalance_xr326-2c -
siemens scalance_xr326-2c_poe_firmware -
siemens scalance_xr326-2c_poe -
siemens scalance_xr328-4c_wg_firmware -
siemens scalance_xr328-4c_wg -
siemens scalance_xr524-8c_firmware -
siemens scalance_xr524-8c -
siemens scalance_xr526-8c_firmware -
siemens scalance_xr526-8c -
siemens scalance_xr528-6m_firmware -
siemens scalance_xr528-6m -
siemens scalance_xr552-12m_firmware -
siemens scalance_xr552-12m -
siemens siplus_net_scalance_xc206-2_firmware -
siemens siplus_net_scalance_xc206-2 -
siemens siplus_net_scalance_xc206-2sfp_firmware -
siemens siplus_net_scalance_xc206-2sfp -
siemens siplus_net_scalance_xc208_firmware -
siemens siplus_net_scalance_xc208 -
siemens siplus_net_scalance_xc216-4c_firmware -
siemens siplus_net_scalance_xc216-4c -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\(4g\\)_eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DFAA9A1-FE88-4F1C-92F3-2D4DCE3CC67E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rm1224_lte\\(4g\\)_eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03D8CF59-D9D4-4C50-A6E6-D6B5BDB31AEC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\(4g\\)_nam_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6ADBD53E-B345-4557-B595-23A17E56705D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rm1224_lte\\(4g\\)_nam:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "400ACE99-AF15-4C20-9A6D-F8584DA5C7CE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m804pb_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21328784-AF25-4714-B533-7BEF16986E19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6EBA42A-93FF-4883-8626-EF78D38374D3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m812-1_adsl-router_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "63CB925E-301E-4ABA-A8D5-8089A7F2874D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m812-1_adsl-router:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "451B1162-CCDE-4658-86B7-DF98468B2721",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m816-1_adsl-router_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FDD3DB2-8ACC-4039-A134-458771460501",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m816-1_adsl-router:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "80BE81AD-F440-4009-A33F-DBE957C3CDD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m826-2_shdsl-router_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "22188289-5FC8-418D-9077-B42F05A2468F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m826-2_shdsl-router:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39951670-CF88-460C-B1D5-6DCFBC7F573D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m874-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A3C8086-4B67-4609-A239-8A606CBC5285",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m874-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C933ED27-2206-4734-8EB8-6A6431D1FBF1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m874-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C186B14-DCBF-43CD-BE7D-2ED72EF6E3C3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m874-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3258DC7-0461-4C65-8292-85C9965EA83D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m876-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEDC7F0A-7AD7-464E-83E2-B433EF076C0C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m876-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD221BA9-3448-49E4-B3A3-D88B939785AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m876-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA2495A6-4AE8-4FD6-8B86-378DD542C59B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m876-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "94E4CCE9-71F7-4960-B7DE-5298EFB7C619",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_mum853-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F71C564-F2D8-4141-A009-C73144973491",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_mum853-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F56875A-B2B3-471F-ADAC-574C55E1D86A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_mum856-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B363B81A-2F6D-4720-83A1-44604125B8CE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_mum856-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "17BEBCAB-D640-4F6D-9579-4A54C76D80F8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EF65A06-2222-47D2-83B5-4C61E6D8731E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "065E9A4C-2F3B-4C13-976C-E8DF4630580F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA5D94EA-C407-446F-B98F-F647ACBBA010",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5984E86-2A83-4927-80E1-62FC75E72C48",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc622-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50FEE5FA-B141-4E5F-8673-363089262530",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc626-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F3AAA53-4DC8-49B7-B77C-DC6759652461",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc626-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EAC3EE40-4398-4337-B40E-8AACDF225BBF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8020D902-3489-4898-A676-C262B0DB4653",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc632-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A79836B-5EC1-40AF-8A57-9657EF6758E5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FDFD39B-1E20-4735-833B-9A89B171C560",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc636-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCB9BD17-7F1F-42E9-831F-EB907F9BC214",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5ADD89C-22C7-45CA-AE2D-1BF63CE6CF97",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc642-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10C7D54A-27B4-4195-8131-DD5380472A75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "656082A8-8160-4A1A-967B-F7CC27A218D5",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc646-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E54AF1E6-0E52-447C-8946-18716D30EBE2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w721-1_rj45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64D0557E-2677-496D-ADC6-A43164499217",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w721-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DABF73D6-D438-4417-A626-A73E84CA7355",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w722-1_rj45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BDC42FA-2A49-4494-A678-DCAA363E41B7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w722-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBB3AC0B-8A73-420D-A5BE-B5FB105BD289",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w734-1_rj45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A20C962-DC09-4B5A-873F-4CEAA00C41BA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w734-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50B58BD7-3B5E-458E-BEB7-EFDC0336454A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w738-1_m12_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD191B35-A96B-4C62-8BBD-F997C658D5D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w738-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8600D53-1137-40C0-9D6E-A9BC87B3697B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w748-1_m12_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "97BE6180-2176-40B2-B73B-8E988728A459",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w748-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F67ECC31-7B5A-4716-B9CF-B3A2AB7D3809",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w761-1_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B763B9EF-C23C-4724-8F7B-54EA8295BF8B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w761-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37A6BD90-9E5B-4828-8B05-E7D18C2D7694",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_m12_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5BAD55E-A127-49CF-A34A-B86A09BB6781",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1_m12_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7F9461B-4089-48E6-AA46-72D53BFC1A2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_m12_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E6DB76A-1F8C-40A7-AD9E-7448FB864529",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1_m12_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B13194C7-B3C0-486B-9BB0-7380271AC51C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FDE9C73-A7AF-4994-8D5C-F49B22F65454",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C775EE0-4F09-40DB-83B4-010A4DA395A2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w778-1_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "412B05DB-DA86-488E-9818-BEA7358DA7E1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w778-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE028852-E293-41D4-8EA9-E7F4C187F383",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w778-1_m12_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12D1DBB7-76E7-4D73-A07A-700A6B44E27F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w778-1_m12_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F5D048A-D906-4AC2-B897-086916DB928C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-1_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F0C250C-5A86-4117-85DD-A86BC3CDBD49",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "96137F44-A487-4A37-BF35-0466F6B947EC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7670B731-0044-4D39-ACE9-4A8C70D481B8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "64140D18-45F0-4745-B204-D1904ECB7F2E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2_sfp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "504C7CBD-FD95-46B6-9AF2-FF9282C2C2F2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2_sfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "301FEDD1-21C9-42B4-ADAF-E97F7387F5E2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2ia_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2BC32A8-3617-48DB-BC07-C683F55B94CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2ia_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8598E40-4F23-47A6-B4B7-EEF168E0B528",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-1_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9B7DADC-7877-4668-B4E9-45B7A8CCB06A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49D960F5-A0D0-4410-A4FD-F0435B3DE3F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-1_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C90F8DD9-064C-4ECE-9A9D-9F1C0274B410",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4706F058-B8C7-4A23-9C12-10D2CC0C3319",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-2_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3093E54-0D81-40E1-92F0-B15F4B03B97C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-2_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C095E360-53A0-4A9A-AD28-841CAE9B4862",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-2_m12_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FFC245C-6185-4477-B1CB-0AF9AFE7B6D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-2_m12_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E7B6FFF-7562-47DD-AEE0-36C119A178AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1748-1_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B4646E-7506-4A23-8833-2503192AD197",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1748-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2353650-D295-4A89-9CF2-50984BE0DD19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-1_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9804602-E66C-4E83-9995-D392ECBE1ABD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "408600B8-762D-43C9-A259-7163FA9DB788",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2_eec_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35B4452A-63DA-43ED-A987-FCD0F28D8F49",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2_eec_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8AE6F9AD-37DB-4067-8BB4-10CDD3AA8E23",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "70FF8CDC-EB85-4CE6-B2C7-ED138F9B9785",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8AA449C-52AE-4286-8BD2-C1A54A1AC64E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2ia_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "985AF207-0160-44FE-985D-0FA3A9248E87",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2ia_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9491822-56EE-4065-B199-040BEE283ED0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam763-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7948D988-3ED9-49BE-B820-15728DA93D21",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam763-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AAE316D-6BA6-4C3F-9EE1-E23E4CB6FD19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B465A44-EC90-41C6-BD9B-59D3B7E49540",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA96B540-439B-4A1A-9D7D-C45AEFBC7BE6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_6ghz_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5690A7D8-2B9F-4DBB-84A8-82B1A7C822B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1_6ghz:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA329302-48FE-43FB-A15D-C3BEFB5AE868",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_ecc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "88B6E0DF-40E8-404A-97D4-24C249CB9947",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1_ecc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "87BF5178-0503-43DB-97C7-0C7852636FD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum763-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "534CF2AE-2149-4599-AC43-13EE8048B3EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum763-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C501445F-BDF6-4A0A-85FD-E6BFBF0A3C6F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum766-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E95E358-45E9-40EC-B3A3-D65C4BA42CE7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum766-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EB15599-F795-4D24-A4A6-CD826F6A7A13",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum766-1_6ghz_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "441DF280-FC8C-481F-BDB9-7D757CF5BB72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum766-1_6ghz:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF8A9161-738C-4730-8EC9-6A5C5FDE279D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "741BF248-4BDF-4D25-8A0F-3584B8529051",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9F9F101-6042-4D11-98CE-16A996023B38",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "126369BE-5503-4F85-8652-AC03F2EE6D14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18DC9125-FC41-4BAB-9638-C42DEF40235B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb208_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D8B4FF5-6C20-41F5-A551-272B5FD84A26",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD92140A-AC7A-463D-99DC-E744A7192532",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B3F6874-3972-435C-89FB-66C9E2729699",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb216_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB116F11-7866-4E74-9037-549462578EA5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D83AF5-9770-43A9-91AE-15EB97A1ACCC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6091005D-A614-4304-94FE-2122D9BF5E00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D32A16B-7D10-4CC8-8E2D-B7B92FBE1E57",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "641699CC-03A4-4DF0-8B1F-EEB658C02E71",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A7D7D3-709A-4872-AC80-FC8EC4915A30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "804E37AB-9EE4-4931-A874-4FBD427252D1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C6E4046-3278-4FDF-84AF-B285905AFF17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC286693-55D6-4949-8164-262EB6C022C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "51F537D2-489A-420F-8167-C527E2ED506A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC7B235D-0141-46E5-9057-2203555AE58A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4AD0884E-98F8-4A67-BD85-AF92674B314C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED2CF432-441D-4707-8E4C-43AC51DF9422",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14FE1E7A-1E4A-4B11-983E-DC39859EAFF0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C54CBCC9-F19D-4993-9D32-8C8778B00E29",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208_poe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C84F8238-18F5-4027-8727-5D999BB1650E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CD4E4B5-7F1E-4005-ACEF-7BD13623EBF9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCEBB0C5-16B2-4B3E-818F-E503A72D785B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-3g_poe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07910A99-B456-4E99-955F-4B08D100E3A2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-3g_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00518DEB-EE44-45AD-AA53-0BBEAF6D3996",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB57F678-CC82-4DF5-9A04-1C85D1B7F521",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25CA5DE7-8645-4DFA-8C2A-C23405FEBAAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78645734-50C1-4331-9FC4-AC8A8679B6AF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "163DDB2C-19D7-4A13-86D5-1258E3F66C3D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "323CEAEA-8122-43A5-BB87-97C7133FF510",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5196C590-7B02-4A9B-BDAC-0770E26498E1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BE498F8-A9D8-4A92-90CE-21BA30234947",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "333852F5-7EF8-41B8-A58D-CE8F00D525A1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4710338E-9449-4AF3-9C91-E7AF9549CA69",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9615F05-CD89-4CCB-B1FB-A76D067BCB15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29A2F221-42ED-4DC3-8D61-89D3545737FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE918926-B0F2-40E9-9453-6F0857543CF1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE51B288-0592-4360-BB83-27675DA261FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F1AE867-67B4-4871-BF56-88017533A737",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204_dna_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81A70627-A17F-4C66-B154-D1D585EFB08B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204_dna:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "70D62F13-AD59-435E-851A-87A0A6E2FA3B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55E6E20A-865B-4FC6-9727-5CB27707177A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EB2D91E-3DB2-4B89-8911-5323B2F0513F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2bca_dna_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE62F317-6D74-4FAA-A12E-BFB229AD4AEC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2bca_dna:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65F65152-F42B-4EDC-90A9-171023690CDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E69D335F-FBC9-4567-B68D-F616F761A609",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AA81823-013F-4990-B62D-86C404F04BCB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D36EF679-0355-4CEA-A247-EA266FEA0843",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7096DBA5-95BB-44D7-B7CA-B1845C87F70E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3850AC0-AC32-480D-B1BB-DE2E1E5A57E4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9102A41-5812-4014-BC07-E571E815ED49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E5FD7D0-770C-4D8E-AAC7-F0F752C57A45",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A75B5F6-B974-463C-BDB7-970982085EE7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B313A4C-D3E7-4964-BA51-3401546B36C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA9F6F24-B1C5-4808-A481-13B1312D01F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6E888EA-73A7-42B8-A617-621CF192F2A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "05515A80-76E4-44D5-B78E-33B07D505451",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4154797A-208E-426F-817A-050B4B96128B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12512EC4-FB7D-420F-9A8A-547562BE1B49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F9FCBCD-5546-4EAB-874A-64B3925287AC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324wg_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50D00EA1-F24F-42C4-9A6B-48E1A572588B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E767C461-8FA6-4700-98CB-734AFD309140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr326-2c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1EBDED3-F7E0-4DC3-A477-1DD76106BBB8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr326-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1CFB380-CE6A-45FF-AF85-F145494D696B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr326-2c_poe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "11593BD9-68E1-4860-A987-73366C06872D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr326-2c_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "91A86897-0140-476D-BBD2-410E08279B70",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5495FD4E-3A57-4C49-99EA-6085DF1D1DBB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5B7DEDC-66BD-4701-BBDD-16273263ADC9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D8E2D30-DDA9-4C2E-A06A-428A42AEF849",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31168EC3-8073-4DB0-8E92-5E0A2780887F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49EA2944-E702-4BF4-B6AD-BF6A737EA866",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4B71459-24D4-4351-BF66-2BB246FF279E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A806691-3F4B-46AA-9718-2F6BF0FD3D7A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_xc206-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C763CFC2-4001-4200-B975-FF1B26F157CE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_xc206-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3296F8-1159-4A4F-B106-43216C55737D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_xc206-2sfp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF228885-3028-4525-A320-CE62818567CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "66C7B087-CAE4-42BC-AAA3-99976870539F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_xc208_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BB380B7-A3BF-4D5C-9113-FC07E3C807DB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_xc208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AC043E2-1DAB-4CF2-B024-88BC6B6B0C89",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_xc216-4c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C35A45E9-BDC8-496A-9E00-6726A99434E0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_xc216-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D52CD11-7965-4864-88BB-76CD31977266",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords."
    },
    {
      "lang": "es",
      "value": "Los dispositivos afectados almacenan las contrase\u00f1as de usuario de CLI cifradas en la memoria flash. Los atacantes con acceso f\u00edsico al dispositivo podr\u00edan recuperar el archivo y descifrar las contrase\u00f1as de usuario de la CLI."
    }
  ],
  "id": "CVE-2022-46142",
  "lastModified": "2025-01-14T11:15:11.407",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "PHYSICAL",
          "availabilityImpact": "LOW",
          "baseScore": 5.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 4.7,
        "source": "productcert@siemens.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "PHYSICAL",
          "availabilityImpact": "NONE",
          "baseScore": 4.6,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "PHYSICAL",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 5.2,
          "baseSeverity": "MEDIUM",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "LOW",
          "vulnerableSystemConfidentiality": "HIGH",
          "vulnerableSystemIntegrity": "LOW"
        },
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-12-13T16:15:25.067",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-257"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-11 20:15
Modified
2024-11-21 05:19
Summary
An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration.
Impacted products
Vendor Product Version
alfa awus036h_firmware 6.1316.1209
alfa awus036h -
siemens scalance_w1748-1_firmware -
siemens scalance_w1748-1 -
siemens scalance_w1750d_firmware -
siemens scalance_w1750d -
siemens scalance_w1788-1_firmware -
siemens scalance_w1788-1 -
siemens scalance_w1788-2_firmware -
siemens scalance_w1788-2 -
siemens scalance_w1788-2_firmware -
siemens scalance_w1788-2 -
siemens scalance_w1788-2ia_firmware -
siemens scalance_w1788-2ia -
siemens scalance_w721-1_firmware -
siemens scalance_w721-1 -
siemens scalance_w722-1_firmware -
siemens scalance_w722-1 -
siemens scalance_w734-1_firmware -
siemens scalance_w734-1 -
siemens scalance_w738-1_firmware -
siemens scalance_w738-1 -
siemens scalance_w748-1_firmware -
siemens scalance_w748-1 -
siemens scalance_w748-1_firmware -
siemens scalance_w748-1 -
siemens scalance_w761-1_firmware -
siemens scalance_w761-1 -
siemens scalance_w774-1_firmware -
siemens scalance_w774-1 -
siemens scalance_w774-1_firmware -
siemens scalance_w774-1 -
siemens scalance_w778-1_firmware -
siemens scalance_w778-1 -
siemens scalance_w778-1_firmware -
siemens scalance_w778-1 -
siemens scalance_w786-1_firmware -
siemens scalance_w786-1 -
siemens scalance_w786-2_firmware -
siemens scalance_w786-2 -
siemens scalance_w786-2_firmware -
siemens scalance_w786-2 -
siemens scalance_w786-2ia_firmware -
siemens scalance_w786-2ia -
siemens scalance_w788-1_firmware -
siemens scalance_w788-1 -
siemens scalance_w788-1_firmware -
siemens scalance_w788-1 -
siemens scalance_w788-2_firmware -
siemens scalance_w788-2 -
siemens scalance_w788-2_firmware -
siemens scalance_w788-2 -
siemens scalance_w788-2_firmware -
siemens scalance_w788-2 -
siemens scalance_wam763-1_firmware -
siemens scalance_wam763-1 -
siemens scalance_wam766-1_firmware -
siemens scalance_wam766-1 -
siemens scalance_wam766-1_firmware -
siemens scalance_wam766-1 -
siemens scalance_wam766-1_6ghz_firmware -
siemens scalance_wam766-1_6ghz -
siemens scalance_wam766-1_6ghz_firmware -
siemens scalance_wam766-1_6ghz -
siemens scalance_wum763-1_firmware -
siemens scalance_wum763-1 -
siemens scalance_wum766-1_firmware -
siemens scalance_wum766-1 -
siemens scalance_wum766-1_6ghz_firmware -
siemens scalance_wum766-1_6ghz -
arista c-100_firmware -
arista c-100 -
arista c-110_firmware -
arista c-110 -
arista c-120_firmware -
arista c-120 -
arista c-130_firmware -
arista c-130 -
arista c-200_firmware -
arista c-200 -
arista c-230_firmware -
arista c-230 -
arista c-235_firmware -
arista c-235 -
arista c-250_firmware -
arista c-250 -
arista c-260_firmware -
arista c-260 -
arista c-65_firmware -
arista c-65 -
arista c-75_firmware -
arista c-75 -
arista o-105_firmware -
arista o-105 -
arista o-90_firmware -
arista o-90 -
arista w-118_firmware -
arista w-118 -
arista w-68_firmware -
arista w-68 -
cisco 1100_firmware -
cisco 1100 -
cisco 1100-4p_firmware -
cisco 1100-4p -
cisco 1100-8p_firmware -
cisco 1100-8p -
cisco 1101-4p_firmware -
cisco 1101-4p -
cisco 1109-2p_firmware -
cisco 1109-2p -
cisco 1109-4p_firmware -
cisco 1109-4p -
cisco aironet_1532_firmware -
cisco aironet_1532 -
cisco aironet_1542d_firmware -
cisco aironet_1542d -
cisco aironet_1542i_firmware -
cisco aironet_1542i -
cisco aironet_1552_firmware -
cisco aironet_1552 -
cisco aironet_1552h_firmware -
cisco aironet_1552h -
cisco aironet_1560_firmware -
cisco aironet_1560 -
cisco aironet_1562d_firmware -
cisco aironet_1562d -
cisco aironet_1562e_firmware -
cisco aironet_1562e -
cisco aironet_1562i_firmware -
cisco aironet_1562i -
cisco aironet_1572_firmware -
cisco aironet_1572 -
cisco aironet_1702_firmware -
cisco aironet_1702 -
cisco aironet_1800_firmware -
cisco aironet_1800 -
cisco aironet_1800i_firmware -
cisco aironet_1800i -
cisco aironet_1810_firmware -
cisco aironet_1810 -
cisco aironet_1810w_firmware -
cisco aironet_1810w -
cisco aironet_1815_firmware -
cisco aironet_1815 -
cisco aironet_1815i_firmware -
cisco aironet_1815i -
cisco aironet_1832_firmware -
cisco aironet_1832 -
cisco aironet_1842_firmware -
cisco aironet_1842 -
cisco aironet_1852_firmware -
cisco aironet_1852 -
cisco aironet_2702_firmware -
cisco aironet_2702 -
cisco aironet_2800_firmware -
cisco aironet_2800 -
cisco aironet_2800e_firmware -
cisco aironet_2800e -
cisco aironet_2800i_firmware -
cisco aironet_2800i -
cisco aironet_3702_firmware -
cisco aironet_3702 -
cisco aironet_3800_firmware -
cisco aironet_3800 -
cisco aironet_3800e_firmware -
cisco aironet_3800e -
cisco aironet_3800i_firmware -
cisco aironet_3800i -
cisco aironet_3800p_firmware -
cisco aironet_3800p -
cisco aironet_4800_firmware -
cisco aironet_4800 -
cisco aironet_ap803_firmware -
cisco aironet_ap803 -
cisco aironet_iw3702_firmware -
cisco aironet_iw3702 -
cisco catalyst_9105_firmware -
cisco catalyst_9105 -
cisco catalyst_9105axi_firmware -
cisco catalyst_9105axi -
cisco catalyst_9105axw_firmware -
cisco catalyst_9105axw -
cisco catalyst_9115_firmware -
cisco catalyst_9115 -
cisco catalyst_9115_ap_firmware -
cisco catalyst_9115_ap -
cisco catalyst_9115axe_firmware -
cisco catalyst_9115axe -
cisco catalyst_9115axi_firmware -
cisco catalyst_9115axi -
cisco catalyst_9117_firmware -
cisco catalyst_9117 -
cisco catalyst_9117_ap_firmware -
cisco catalyst_9117_ap -
cisco catalyst_9117axi_firmware -
cisco catalyst_9117axi -
cisco catalyst_9120_firmware -
cisco catalyst_9120 -
cisco catalyst_9120_ap_firmware -
cisco catalyst_9120_ap -
cisco catalyst_9120axe_firmware -
cisco catalyst_9120axe -
cisco catalyst_9120axi_firmware -
cisco catalyst_9120axi -
cisco catalyst_9120axp_firmware -
cisco catalyst_9120axp -
cisco catalyst_9124_firmware -
cisco catalyst_9124 -
cisco catalyst_9124axd_firmware -
cisco catalyst_9124axd -
cisco catalyst_9124axi_firmware -
cisco catalyst_9124axi -
cisco catalyst_9130_firmware -
cisco catalyst_9130 -
cisco catalyst_9130_ap_firmware -
cisco catalyst_9130_ap -
cisco catalyst_9130axe_firmware -
cisco catalyst_9130axe -
cisco catalyst_9130axi_firmware -
cisco catalyst_9130axi -
cisco catalyst_iw6300_firmware -
cisco catalyst_iw6300 -
cisco catalyst_iw6300_ac_firmware -
cisco catalyst_iw6300_ac -
cisco catalyst_iw6300_dc_firmware -
cisco catalyst_iw6300_dc -
cisco catalyst_iw6300_dcw_firmware -
cisco catalyst_iw6300_dcw -
cisco esw-6300-con-x-k9_firmware -
cisco esw-6300-con-x-k9 -
cisco esw6300_firmware -
cisco esw6300 -
cisco ip_phone_6861_firmware -
cisco ip_phone_6861 -
cisco ip_phone_8821_firmware -
cisco ip_phone_8821 -
cisco ip_phone_8832_firmware -
cisco ip_phone_8832 -
cisco ip_phone_8861_firmware -
cisco ip_phone_8861 -
cisco ip_phone_8865_firmware -
cisco ip_phone_8865 -
cisco ir829-2lte-ea-ak9_firmware -
cisco ir829-2lte-ea-ak9 -
cisco ir829-2lte-ea-bk9_firmware -
cisco ir829-2lte-ea-bk9 -
cisco ir829-2lte-ea-ek9_firmware -
cisco ir829-2lte-ea-ek9 -
cisco ir829gw-lte-ga-ck9_firmware -
cisco ir829gw-lte-ga-ck9 -
cisco ir829gw-lte-ga-ek9_firmware -
cisco ir829gw-lte-ga-ek9 -
cisco ir829gw-lte-ga-sk9_firmware -
cisco ir829gw-lte-ga-sk9 -
cisco ir829gw-lte-ga-zk9_firmware -
cisco ir829gw-lte-ga-zk9 -
cisco ir829gw-lte-na-ak9_firmware -
cisco ir829gw-lte-na-ak9 -
cisco ir829gw-lte-vz-ak9_firmware -
cisco ir829gw-lte-vz-ak9 -
cisco meraki_gr10_firmware -
cisco meraki_gr10 -
cisco meraki_gr60_firmware -
cisco meraki_gr60 -
cisco meraki_mr12_firmware -
cisco meraki_mr12 -
cisco meraki_mr20_firmware -
cisco meraki_mr20 -
cisco meraki_mr26_firmware -
cisco meraki_mr26 -
cisco meraki_mr30h_firmware -
cisco meraki_mr30h -
cisco meraki_mr32_firmware -
cisco meraki_mr32 -
cisco meraki_mr33_firmware -
cisco meraki_mr33 -
cisco meraki_mr34_firmware -
cisco meraki_mr34 -
cisco meraki_mr36_firmware -
cisco meraki_mr36 -
cisco meraki_mr42_firmware -
cisco meraki_mr42 -
cisco meraki_mr42e_firmware -
cisco meraki_mr42e -
cisco meraki_mr44_firmware -
cisco meraki_mr44 -
cisco meraki_mr45_firmware -
cisco meraki_mr45 -
cisco meraki_mr46_firmware -
cisco meraki_mr46 -
cisco meraki_mr46e_firmware -
cisco meraki_mr46e -
cisco meraki_mr52_firmware -
cisco meraki_mr52 -
cisco meraki_mr53_firmware -
cisco meraki_mr53 -
cisco meraki_mr53e_firmware -
cisco meraki_mr53e -
cisco meraki_mr55_firmware -
cisco meraki_mr55 -
cisco meraki_mr56_firmware -
cisco meraki_mr56 -
cisco meraki_mr62_firmware -
cisco meraki_mr62 -
cisco meraki_mr66_firmware -
cisco meraki_mr66 -
cisco meraki_mr70_firmware -
cisco meraki_mr70 -
cisco meraki_mr72_firmware -
cisco meraki_mr72 -
cisco meraki_mr74_firmware -
cisco meraki_mr74 -
cisco meraki_mr76_firmware -
cisco meraki_mr76 -
cisco meraki_mr84_firmware -
cisco meraki_mr84 -
cisco meraki_mr86_firmware -
cisco meraki_mr86 -
cisco meraki_mx64w_firmware -
cisco meraki_mx64w -
cisco meraki_mx65w_firmware -
cisco meraki_mx65w -
cisco meraki_mx67cw_firmware -
cisco meraki_mx67cw -
cisco meraki_mx67w_firmware -
cisco meraki_mx67w -
cisco meraki_mx68cw_firmware -
cisco meraki_mx68cw -
cisco meraki_mx68w_firmware -
cisco meraki_mx68w -
cisco meraki_z3_firmware -
cisco meraki_z3 -
cisco meraki_z3c_firmware -
cisco meraki_z3c -
cisco webex_board_55_firmware -
cisco webex_board_55 -
cisco webex_board_55s_firmware -
cisco webex_board_55s -
cisco webex_board_70_firmware -
cisco webex_board_70 -
cisco webex_board_70s_firmware -
cisco webex_board_70s -
cisco webex_board_85s_firmware -
cisco webex_board_85s -
cisco webex_dx70_firmware -
cisco webex_dx70 -
cisco webex_dx80_firmware -
cisco webex_dx80 -
cisco webex_room_55_firmware -
cisco webex_room_55 -
cisco webex_room_55_dual_firmware -
cisco webex_room_55_dual -
cisco webex_room_70_firmware -
cisco webex_room_70 -
cisco webex_room_70_dual_firmware -
cisco webex_room_70_dual -
cisco webex_room_70_dual_g2_firmware -
cisco webex_room_70_dual_g2 -
cisco webex_room_70_single_firmware -
cisco webex_room_70_single -
cisco webex_room_70_single_g2_firmware -
cisco webex_room_70_single_g2 -
cisco webex_room_kit_firmware -
cisco webex_room_kit -
cisco webex_room_kit_mini_firmware -
cisco webex_room_kit_mini -
intel ac_8260_firmware -
intel ac_8260 -
intel ac_8265_firmware -
intel ac_8265 -
intel ac_9260_firmware -
intel ac_9260 -
intel ac_9560_firmware -
intel ac_9560 -
intel killer_ac_1550_firmware -
intel killer_ac_1550 -
intel killer_wi-fi_6_ax1650_firmware -
intel killer_wi-fi_6_ax1650 -
intel killer_wi-fi_6e_ax1675_firmware -
intel killer_wi-fi_6e_ax1675 -
intel proset_ac_3165_firmware -
intel proset_ac_3165 -
intel proset_ac_3168_firmware -
intel proset_ac_3168 -
intel proset_ac_8260_firmware -
intel proset_ac_8260 -
intel proset_ac_8265_firmware -
intel proset_ac_8265 -
intel proset_ac_9260_firmware -
intel proset_ac_9260 -
intel proset_ac_9461_firmware -
intel proset_ac_9461 -
intel proset_ac_9462_firmware -
intel proset_ac_9462 -
intel proset_ac_9560_firmware -
intel proset_ac_9560 -
intel proset_wi-fi_6_ax200_firmware -
intel proset_wi-fi_6_ax200 -
intel proset_wi-fi_6_ax201_firmware -
intel proset_wi-fi_6_ax201 -
intel proset_wi-fi_6e_ax210_firmware -
intel proset_wi-fi_6e_ax210 -
intel proset_wireless_7265_\(rev_d\)_firmware -
intel proset_wireless_7265_\(rev_d\) -
intel wi-fi_6_ax200_firmware -
intel wi-fi_6_ax200 -
intel wi-fi_6_ax201_firmware -
intel wi-fi_6_ax201 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:alfa:awus036h_firmware:6.1316.1209:*:*:*:*:windows_10:*:*",
              "matchCriteriaId": "8A9FCD5B-54DD-4EF7-AB08-56EDE3B35E7B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:alfa:awus036h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF0F9200-8AFD-4100-AF39-49476298C0E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1748-1_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "68C08ECE-4D09-4E57-920B-B8E94E81603A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1748-1:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "83B4B8A7-6CAE-43F7-8DCF-0129392E41A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1750d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D412FC9-835A-4FAB-81B0-4FFB8F48ACA3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1750d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FBC30055-239F-4BB1-B2D1-E5E35F0D8911",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-1_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "F5154A83-2499-4756-9150-8BFD9ACEF583",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-1:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "7CC235C6-63B1-4085-B9AA-47EFB17A144D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2_firmware:-:*:*:*:*:*:eec_m12:*",
              "matchCriteriaId": "8396EACC-A0FA-4A4A-8411-8D9ED40B7F28",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2:-:*:*:*:*:*:eec_m12:*",
              "matchCriteriaId": "54C41A49-87FA-4C98-8321-2808712B2F68",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "F8ED25D1-973F-481A-8550-16508F73D2D2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "35918620-E4C5-4E46-A5A9-63009333667A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2ia_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "27440732-54F0-40DF-9896-88D60ABC568A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2ia:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "FC39A276-532B-428A-83BA-141B626281A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w721-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "93103556-6C4A-4D35-91D1-5CDCDC740655",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w721-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "5DEFC044-1D95-4386-AABB-ADE1099E3F85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w722-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "42759A0F-70C6-41DB-9DF9-2BC05685F678",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w722-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "95662406-0D7D-45B2-95F5-582FA275AC89",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w734-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "A0E9FB66-F577-4744-B51F-3BD25293109F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w734-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "079DA749-0B94-4CCF-A3B1-7669DA213B52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w738-1_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "05D1BC5E-C26E-4E3D-B0DF-014C7DE16F4A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w738-1:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "D96A05C3-1549-47DD-BADA-7872246EBDA0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w748-1_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "2E7375AB-BE32-4879-BB54-CF5EDAB98188",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w748-1:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "0E9E26B8-1539-4E21-AEAA-45095F79382A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w748-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "8BD6E779-AFE3-48C3-95B7-E7BED14BAE0B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w748-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "5AA05DFB-5C02-4822-8D32-406C11ABFFC2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w761-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "0F01F2C2-E968-45EE-BA91-39AEEFC0345C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w761-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "19C73CA1-2F92-4635-8D38-812D6D8ACD89",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_firmware:-:*:*:*:*:*:m12_eec:*",
              "matchCriteriaId": "EA17907A-388A-42E7-ACC6-2F59C72C93F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1:-:*:*:*:*:*:m12_eec:*",
              "matchCriteriaId": "A53A71EB-C346-42CD-AD58-F83F809D0CA9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "F801DE5A-781D-4DDA-9BD3-A9F3A4501D34",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "90E87633-CD6E-439B-9CE8-66A1E414F09D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w778-1_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "742D9262-4329-4F0A-B97E-5FC65786946F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w778-1:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "A04D6C4A-C7DB-4757-8C34-BE6EB7D1BC50",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w778-1_firmware:-:*:*:*:*:*:m12_eec:*",
              "matchCriteriaId": "FC14C45F-FDFB-4AAC-94EC-45860051379F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w778-1:-:*:*:*:*:*:m12_eec:*",
              "matchCriteriaId": "C01E79D8-5F48-4939-BFD6-B363A76769D7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "CEE50FA1-6616-402A-9D86-9725206612C6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "5B907930-CA5C-4160-A3D1-8ACB559C9143",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "9331282F-B426-40DC-869E-F6F7DFE959A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "CAE6D7C0-9AA7-4EE7-B5A9-987BC549442E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2_firmware:-:*:*:*:*:*:sfp:*",
              "matchCriteriaId": "C67D4B91-66EB-490E-B43D-A7E159CC543B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2:-:*:*:*:*:*:sfp:*",
              "matchCriteriaId": "45A6A314-804B-47DC-B35E-804AD89588D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2ia_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "236FBB62-ADAF-4316-BE4A-0F3ACE9B94FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2ia:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "968D60A4-036A-4792-BE8E-88F8B26444DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-1_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "754B93BA-0451-4C09-A124-284A62189D53",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-1:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "85293635-DD43-4651-8605-4F27F228AA91",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-1_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "826FB2F4-45B5-4360-B577-11F75A1B67A2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-1:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "F3417E19-D7FC-487D-B316-B826DB3CB712",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-2_firmware:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "4B7AFF23-828B-4BB4-8A00-0E5C852C95C2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-2:-:*:*:*:*:*:m12:*",
              "matchCriteriaId": "9A9E77DB-7B9D-40D0-8947-DFB1B2B7522C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-2_firmware:-:*:*:*:*:*:m12_eec:*",
              "matchCriteriaId": "B66B6DB7-E48C-4758-915E-E4096CC5D68E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-2:-:*:*:*:*:*:m12_eec:*",
              "matchCriteriaId": "69C3A33C-85E1-4157-81F7-39FA271CF8ED",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-2_firmware:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "E65FB9EC-A750-44C9-B251-5D8697C29EC2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-2:-:*:*:*:*:*:rj45:*",
              "matchCriteriaId": "64BD7639-6E6B-4ED7-8AB9-393BC48F10F5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam763-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7948D988-3ED9-49BE-B820-15728DA93D21",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam763-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AAE316D-6BA6-4C3F-9EE1-E23E4CB6FD19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B465A44-EC90-41C6-BD9B-59D3B7E49540",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA96B540-439B-4A1A-9D7D-C45AEFBC7BE6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_firmware:-:*:*:*:*:*:eec:*",
              "matchCriteriaId": "3684DA7E-E49F-42A6-9DA2-FEF6DEDBE9B8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1:-:*:*:*:*:*:eec:*",
              "matchCriteriaId": "43A34072-F6CC-4843-9FEF-E0ECA96BBAEA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_6ghz_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5690A7D8-2B9F-4DBB-84A8-82B1A7C822B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1_6ghz:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA329302-48FE-43FB-A15D-C3BEFB5AE868",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_6ghz_firmware:-:*:*:*:*:*:eec:*",
              "matchCriteriaId": "AA44AF5A-1AAD-4C68-8771-E14BA8ABFBA6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1_6ghz:-:*:*:*:*:*:eec:*",
              "matchCriteriaId": "37055F7B-2F2A-4B80-AC34-CAB0568BC692",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum763-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "534CF2AE-2149-4599-AC43-13EE8048B3EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum763-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C501445F-BDF6-4A0A-85FD-E6BFBF0A3C6F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum766-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E95E358-45E9-40EC-B3A3-D65C4BA42CE7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum766-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EB15599-F795-4D24-A4A6-CD826F6A7A13",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum766-1_6ghz_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "441DF280-FC8C-481F-BDB9-7D757CF5BB72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum766-1_6ghz:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF8A9161-738C-4730-8EC9-6A5C5FDE279D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-100_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "11CE6C04-4994-463F-A456-1D47F2BD793A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "132AD177-3F7F-4CD7-9BD5-EE5A24CE671C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-110_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA7E7D8A-CC58-47F6-9F3F-BE74F1CF27E8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-110:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4E82587-A7A1-4057-896A-F30B9DF7C831",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-120_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89F2DFE1-6E7B-42CC-9814-90F426D14490",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE3EC767-2ECA-44E4-AA03-9E2673A2B2F3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-130_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8197BD27-2AD7-434C-8F64-24B3D6D6E188",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81C15C55-207E-4030-AC2A-B2E3791D92B0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-200_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB011F08-5526-4D49-8100-A874CD265FB5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F81C550-CE6F-4E68-A088-5EC0CEF40600",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-230_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1C3DCD8-9AD7-411B-95DC-B989EEC3E035",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-230:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29B18F4E-4968-493A-BC90-5D8D7F619F39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-235_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AAA44BE-54CE-498B-83EF-D21DF2A57A5E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-235:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "54878C0D-8842-490F-B556-76AF47A65891",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-250_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2A71084-E505-4648-9B5C-C0305DCE91AF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-250:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE97F0AD-8658-476A-8E22-DA67A5FD9F73",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-260_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "60A09137-CF46-420E-9792-BB6E46C5C415",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-260:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A006A8BD-D56E-40C2-ADD2-C11759153808",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-65_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C890ABE-5D64-4D7F-A67B-BC026649E0B3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-65:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B617EA3-E69E-43CA-99D4-86A408C55C90",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:c-75_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD2A3CCF-E8B5-4E7F-BCE7-DB70E8E72B4B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:c-75:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EE26D5A-486B-48F3-9C1C-4EE3FD8F0234",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:o-105_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF499EE6-0047-42C0-8360-6A2B3DF51B1B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:o-105:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A31FF47-55EE-451B-ABDD-CE82E8EFBC98",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:o-90_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B9860B5-6CC7-4F29-9514-A469AF6B28F1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:o-90:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "41F9E4B2-63FC-4F53-9C12-7478B7B6AD48",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:w-118_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C9D810C-AA04-4748-80EB-3FB5DE507F89",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:w-118:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BEE861E-2604-42BD-ABAA-DA729F4EBDBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:arista:w-68_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C1EF830-C210-48DB-A3F8-FC706AC5F3C7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arista:w-68:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F03BB48-C89A-41F6-99DE-12FF95DCD9F2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:1100_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F7999A6-03FE-4C38-9C46-B3221E7B3815",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:1100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC042678-29AA-44F7-BBF0-1D752D25687D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:1100-4p_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81634E2A-FAD5-4B1C-A93E-545870615343",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:1100-4p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA8D5057-138A-42C4-BA35-8077A0A60068",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:1100-8p_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECAB3869-E15B-4ED4-A98C-75DE0DBA8F3F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:1100-8p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED555B12-41F4-4D62-B519-22601FB7AF8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:1101-4p_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "57F5F016-52B5-4A4C-9EE0-B478A98CEC9A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:1101-4p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21B10158-5235-483E-BACD-C407609EA6BE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:1109-2p_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B17C8544-CB4E-407B-BE52-4D42D81BF1BA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:1109-2p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8964F9BA-6E6C-44BF-9A8C-93D081B6678C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:1109-4p_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA214FF2-358E-4291-B803-58A9AC14ABEC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:1109-4p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "51251FE1-67D2-4903-B7D3-E0C727B9A93C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1532_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31FB34B4-235B-4C92-8E9C-DD04136C745F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1532:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CCECB59-4EA8-4FD4-81CB-329EBF7C080C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1542d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2051CA5B-967D-4830-87EB-1756559C1FED",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1542d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5DB7510-2741-464A-8FC9-8419985E330F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1542i_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C72EC048-B84B-4744-BC04-BA8612C79D04",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1542i:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3AE916B2-CAAD-4508-A47E-A7D4D88B077A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1552_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB5DD78C-B89C-44AF-B153-033FEDE22CF8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1552:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B54636F7-8061-49A1-923B-F976491593CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1552h_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D795375C-E17C-4E05-8C88-F080C22652B2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1552h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9BA6C6D9-9980-4EE7-9A7D-02D5D34DE878",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1560_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA6EF369-8D83-4F5D-BDBE-99E89AD84810",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1560:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8191FD87-4E55-4F38-8DB0-7E6772AD075B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1562d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10BD5327-F3F8-4D0A-B6DC-2F11DF2E6866",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1562d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D717945-EE41-4D0F-86EF-90826EBE9C3E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1562e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "893D104F-6711-46F9-804C-4B57562166E7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1562e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "99EAEA92-6589-4DFB-BC4B-8CBA425452D9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1562i_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E4AABCC2-D2A5-4A89-9DF9-6F80EB871CC9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1562i:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D27AB201-342D-4517-9E05-6088598F4695",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1572_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "53106CD6-749D-4781-B28E-E075E61D1196",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1572:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1FA8DA7-0D47-4C37-B96A-EBE004B0B23B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1702_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C25445A6-4B1E-4F77-804D-FFD9507B022A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1702:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "729FDD5F-C378-4DF1-B6CB-A1F62FD4550D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1800_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "54BDAFC3-940F-40C4-896E-99B6DABA9E3F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "02F4C00A-D1E2-4B21-A14E-F30B4B818493",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1800i_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9FC7CCB-52D2-4B4D-82AA-759C80E17018",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1800i:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC836B4D-A489-4300-B0A2-EF0B6E01E623",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1810_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB94F02B-C71A-4EAE-B931-30CFA52A890C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1810:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36F923CF-D4EB-48F8-821D-8BB3A69ABB62",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1810w_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF011423-521A-41C4-A403-FF82C2C14874",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1810w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D613A17-FFA9-4FF0-9C2A-AF8ACD59B765",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1815_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E076DDF4-6817-4CFD-B4A3-243D8D755DE3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1815:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8BF9DDB-884D-47B5-A295-8BFA5207C412",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1815i_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "205E19BF-078D-475D-A9F0-4A1604A2D554",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1815i:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "207DC80E-499C-4CA3-8A88-F027DBC64CCF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1832_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72A15C8E-73D8-480D-B5C9-E72E8D4695D0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1832:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "751469E2-91A8-48F1-81A8-AEBF1420EECE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1842_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFAEDA4F-C728-4D60-8661-90429A264E40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1842:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18035D1A-C8D9-4055-A5CA-541711DBA71A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_1852_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "883C24F0-99B3-42E0-AC27-6B4B3D4F5FA2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_1852:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "80871D9C-43D5-4507-AC36-CDD7CC4A7C86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_2702_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8CC13255-92FB-4585-B6EF-E4D94EB6158D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_2702:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1917B7F4-17DD-4734-A856-ED7CE9AF8DA7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_2800_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAD27F3F-961F-4F44-AD2D-CF9EAD04E2B5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_2800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C28A6B0-10FF-4C6D-8527-2313E163C98E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_2800e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A796152-A567-4B7A-8202-94858CD95119",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_2800e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "098A82FF-95F7-416A-BADD-C57CE81ACD32",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_2800i_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED80079E-2744-4325-86DA-EA3647B45179",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_2800i:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD1D5813-9223-4B3F-9DE2-F3EF854FC927",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_3702_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B836136-CCD2-49AC-9871-1C3B6255EDA7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_3702:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F72DB8D-9A3F-436A-AE5D-AC8941ED527E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_3800_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFFE3575-DDAF-433E-8D77-4CCADADC99B9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_3800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7636F7E2-E386-4F8C-A0C5-F510D8E21DA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_3800e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FD51123-ECF1-4042-AE1C-724FF4C51F43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_3800e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10D7583E-2B61-40F1-B9A6-701DA08F8CDF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_3800i_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34C47517-5F78-4D3C-818E-6DBFD1B56592",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_3800i:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "945DDBE7-6233-416B-9BEE-7029F047E298",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_3800p_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F103B67B-89C9-465D-AF2E-3D24A8F5465D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_3800p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0ED89428-750C-4C26-B2A1-E3D63F8B3F44",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_4800_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5618CE7C-DF82-4849-AC79-A00B747883BE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_4800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4D8A4CB-5B80-4332-BCBC-DA18AD94D215",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_ap803_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40F38C35-EFC2-4CF9-AD88-FADC42F0649D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_ap803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5062B18F-F28C-4975-A5A3-45C0EC03F448",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:aironet_iw3702_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "338A22C8-5617-45C8-AB3E-5E45341DFE60",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:aironet_iw3702:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6214A82C-54A6-48FC-9714-742704BEF1D3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9105_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68410865-70F5-4578-99E4-827DBE0207B1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9105:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F3CCCFE-88CC-4F7B-8958-79CA62516EA9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9105axi_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FF827E8-02BE-42C0-A0CE-B649601847E4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9105axi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "19F93DF4-67DB-4B30-AC22-60C67DF32DB2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9105axw_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C9309C6-EC43-4EB9-BD7A-CBCC581AA58C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9105axw:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "59C77B06-3C22-4092-AAAB-DB099A0B16A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9115_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EEB7E5B-AE32-455A-A351-368FB78E5276",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9115:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4081C532-3B10-4FBF-BB22-5BA17BC6FCF8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9115_ap_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EE86352-EEDB-4890-87B8-025EA970219B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9115_ap:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "56A3430C-9AF7-4604-AD95-FCF2989E9EB0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9115axe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C3DCF4E-081A-4375-A4A0-AAAD8F024114",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9115axe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE4C56A6-E843-498A-A17B-D3D1B01E70E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9115axi_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B69CC2B-CD3A-4BEF-8FF1-9925E460B049",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9115axi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F050F416-44C3-474C-9002-321A33F288D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9117_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "06C11A3E-E431-4923-AEBA-25E3247F19C3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9117:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FCE2220-E2E6-4A17-9F0A-2C927FAB4AA5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9117_ap_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E48E571-AE00-47E2-BABC-849A63DBDCF4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9117_ap:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4AE36E2-E7E9-4E49-8BFF-615DACFC65C1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9117axi_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9A46503-A8BD-4F95-BAB0-2DE5D689DD4F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9117axi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A699C5C-CD03-4263-952F-5074B470F20E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9120_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1EA2B34D-533C-4316-AD59-EA2FCF10B9F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A47C2D6F-8F90-4D74-AFE1-EAE954021F46",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9120_ap_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A8A6B51-5192-4B98-9D94-682290890074",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9120_ap:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C04889F8-3C2A-41AA-9DC9-5A4A4BBE60E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9120axe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D07AB0E3-151D-4D80-A482-41E7A27AE068",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9120axe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "46D41CFE-784B-40EE-9431-8097428E5892",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9120axi_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A99728C-9E6B-4249-BAAA-C080109EFC4A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9120axi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D148A27-85B6-4883-96B5-343C8D32F23B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9120axp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C73A651-932E-43CA-B40F-2F75510AEE36",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9120axp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "735CA950-672C-4787-8910-48AD07868FDE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9124_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A71D9CA-91DF-48DD-AE3D-DED883666A75",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9124:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C11EF240-7599-4138-B7A7-17E4479F5B83",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9124axd_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF43EC0A-AC28-408A-8375-11CE249217A1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9124axd:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E987C945-4D6D-4BE5-B6F0-784B7E821D11",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9124axi_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABA19FD7-047B-43AA-9237-807AAA2E9F7D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9124axi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B434C6D7-F583-4D2B-9275-38A5EC4ECC30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9130_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "19D85A86-1D8B-4006-8BF7-4593B1D7EB70",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1C8E35A-5A9B-4D56-A753-937D5CFB5B19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9130_ap_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "166D74EA-8820-4C78-B43B-FCBC9779FCB7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9130_ap:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "248A3FFC-C33C-4336-A37C-67B6046556E5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9130axe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67C380AE-C888-4AED-80D2-B9AF5EB9EC85",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9130axe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EC1F736-6240-4FA2-9FEC-D8798C9D287C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_9130axi_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AA48001-7F56-4155-B70D-5DC41D73DB38",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_9130axi:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "169E5354-07EA-4639-AB4B-20D2B9DE784C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_iw6300_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB09D94E-A6B2-496D-87A3-53CB9872FA69",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_iw6300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C559D6F7-B432-4A2A-BE0E-9697CC412C70",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_iw6300_ac_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE4AFA1C-5A9E-4DF4-B9C7-66EF918548C5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_iw6300_ac:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "23153AA4-B169-4421-BFF8-873205FC9C21",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_iw6300_dc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE3E846C-359B-4EF1-AD68-DE612C5697F4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_iw6300_dc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67DC3B71-B64D-4C49-B089-B274FA34ECB6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:catalyst_iw6300_dcw_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4CFE9F2D-407B-49CE-BB6C-80DC941A9371",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:catalyst_iw6300_dcw:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F857465-314F-4124-9835-8A269486D654",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:esw-6300-con-x-k9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "90A743E4-1302-4DAB-9300-65D8F468C8F2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:esw-6300-con-x-k9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED3625BC-9003-4E07-B4EA-EB44CADDD6B4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:esw6300_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3EBAC6D-93DB-4380-8B6E-61555A9C8A3C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:esw6300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09051BC5-CFE7-43EF-975D-BF77724E8776",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ip_phone_6861_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD79F5E4-AA2D-40EB-9E59-2FEB4FD49ECD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ip_phone_6861:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C05A7CA6-AD58-45D7-AF32-129E22855D8E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ip_phone_8821_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A138C033-0F4D-41F8-B0FF-CDE9261DA7D9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ip_phone_8821:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36C99E0B-0383-4CB3-B325-EC0F3D57D39D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ip_phone_8832_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2CDAD5D-3702-42EE-AE5A-A08842870EEA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ip_phone_8832:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5EA5C6B-243B-419A-9C60-1CDBD039C1D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ip_phone_8861_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CC9DD95-DC0E-4A47-A0EB-32D551B323CD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ip_phone_8861:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "090EE553-01D5-45F0-87A4-E1167F46EB77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ip_phone_8865_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAAAB671-8EBF-4D9C-9AA5-E3C306CDB931",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ip_phone_8865:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB99B9AB-64B5-4989-9579-A1BB5D2D87EF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829-2lte-ea-ak9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB907B21-237D-4629-964C-408B5AD590E6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829-2lte-ea-ak9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB62C534-29F8-48CA-9D45-42C49CE68577",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829-2lte-ea-bk9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2F956BF-E845-43FF-87A8-EA62DDFB1228",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829-2lte-ea-bk9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B670C5A3-4E19-428F-87D0-C2B12EE2CB92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829-2lte-ea-ek9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4541452E-32E8-451B-B8F3-1118ECCBAE50",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829-2lte-ea-ek9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BF5C3D3-833D-405B-8E1E-ED3BC29CD5E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829gw-lte-ga-ck9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5C512E9-F7A6-492E-BE4B-93858E34CCD9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829gw-lte-ga-ck9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8D39174-298E-4C06-A289-B0C4585B2E99",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829gw-lte-ga-ek9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6041298-45A9-41CB-A644-55D5DC40B5D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829gw-lte-ga-ek9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB259DDC-AB98-405E-A369-49A3B89F48F5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829gw-lte-ga-sk9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A1385AA-FACE-4150-93E8-610A73F90CCB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829gw-lte-ga-sk9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "99B57D05-6702-4026-9E36-0CBEC6BE8001",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829gw-lte-ga-zk9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "715401BE-1E29-4260-9D10-245C6246BE94",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829gw-lte-ga-zk9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC62F7A8-9D57-4703-A7DF-451C2CA75919",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829gw-lte-na-ak9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC762476-57D4-40E8-BE70-2F6861F31EF7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829gw-lte-na-ak9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78F497A3-8153-4524-9E8D-2CFDCF2ADCDE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:ir829gw-lte-vz-ak9_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "795A3C41-753D-4590-B71F-37E9DD7DD5D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:ir829gw-lte-vz-ak9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61BD4298-A8D5-4D7C-A9D9-694606042C12",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_gr10_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E9F6455-59CC-4A3B-AFDD-60B5DD1E9ECF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_gr10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5EF406E2-A24B-4D94-B4F7-2186B1D82462",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_gr60_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC624300-4EBB-44B9-9D90-F411368FE60A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_gr60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "33B44092-CC37-4683-920D-8F84C60CCCEF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9005D484-CEF5-4B8D-86B0-6CB5860A157E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03F4DBFC-42FC-44FD-9EDF-4C0C92053E4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr20_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE66B0F4-1211-40A4-BDB3-D8F6C74678AF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B1207B-C065-483D-8AB3-6B9CEC4D3C7C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr26_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "06205774-F85A-42F8-B599-1A529BBFA68B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr26:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "60D19311-A114-455C-9011-004446C80E27",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr30h_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C922D55-E2DC-4970-A381-30F95CEB038B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr30h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "602DA0AF-86EB-4A01-BDE3-43596DEC746A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr32_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B2718D7-1D20-40D5-9E43-7AE1AA7AFCCF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr32:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E011F146-3AB9-446D-ACFD-FE5B021735D3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr33_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFB4CE7A-6FC1-4171-A743-CD8BB14C9864",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr33:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12E670DC-C4D2-4277-A4DD-222D60A7CDB1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr34_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7449719-1071-41B8-BDE9-81ACFBEE5D0F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr34:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "814ADA42-72A9-48D6-B524-5F5BD76F3059",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr36_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25616833-BCF6-4611-A9AB-248F761C5603",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr36:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A66108F-5CED-4D41-8EE9-9479090B31DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr42_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "92DD4610-420C-459B-9B05-85600EF466D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr42:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18E7D194-AA15-43CD-9019-7B286F528773",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr42e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78B15252-5725-4B7B-8DBE-10251EB9C212",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr42e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FB4754D-3B94-42AA-A150-6BDFF42B3270",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr44_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63217CCA-1926-46AD-956E-702A94420D91",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr44:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07E495B6-CA7A-4F58-99A2-550F83E1E020",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B9BC8A2-451A-4BDE-B073-FF39DD9E5D90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4F47740-D0F3-478B-AFC3-51EB3AED34A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr46_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7DC56150-D025-40A9-B350-8E95B62D236C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr46:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27E9718F-E50B-412F-86D7-DA6F39056006",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr46e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914C5C0C-EACD-4A4C-83B2-26AA4EF283D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr46e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6B83072-84F6-43A4-9CC1-32924AFCC737",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr52_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1F09491-2234-4C86-A80C-445B48A9FE78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr52:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5634D1AB-B64D-44D0-A431-FE52E879B4BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr53_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8998B44-D926-46F9-AF3F-02EEF99680A5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr53:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "920CF4B6-9424-48DA-9622-FB0C0510E52F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr53e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "746D2300-CA9A-4C09-9A2B-FCC9DAEC74EC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr53e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EC322AE-6731-41F3-9C59-8CF9622D997A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr55_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "79419F89-0F01-4FD7-9102-ABFAFF3F2424",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr55:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0036877-C975-4AC7-B933-E5BC5E300B44",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr56_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC64210E-A2F8-42DC-AB94-2547A51F63C5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr56:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E37474E5-76DE-4326-A5A8-D8900A8A2F62",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr62_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "089164E3-B852-43BA-8C2C-FEE1C267C58C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr62:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F8F3095-F280-44B0-8BC6-50221247ACE1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr66_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27DA3F64-514B-4DB7-A6B0-6A303F296DC7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr66:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBB99337-4422-46AB-9B79-A96CE207AC28",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr70_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD532656-21FE-4F82-846E-C8CB752B87F1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr70:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37D7E013-920A-4C32-98C1-FBD7C450DD88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr72_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E80D395-C853-41A3-8438-BF880C799A01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr72:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68086DA9-AD50-41DC-B8B5-D9BB0512C6B6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr74_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D8181BA-846A-4D83-9DB9-B915B9EFFD7C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr74:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "366ABABA-D9C5-4D46-9516-7262AA32D4CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr76_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B02C40A8-0294-4C3D-8AC9-8D56AF1D2B4E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr76:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D071FC26-097A-432B-8900-DA02D3116D29",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr84_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D4901FE-B1AE-4CAB-9D91-139737B6E832",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr84:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9543B910-A999-4CEF-B06A-3F1A46784BF0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mr86_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC06358C-6F27-4A27-8553-CF138D4214CC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mr86:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A57AA24E-09E0-4EB6-9580-A68267767119",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mx64w_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "15CD8683-DFB3-45E3-B6E2-92AFD846B0BA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mx64w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1038F5F-020D-41FD-9C3D-F2685F1EA916",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mx65w_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "01AD96C5-1620-4339-94E7-343E1ADAAC4C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mx65w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69A23113-F7E1-4587-A4FF-A4AAB446A69D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mx67cw_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F910935-E534-462D-8045-71C58BDD7285",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mx67cw:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E85585DA-C918-445B-9B44-B2B1A982A1F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mx67w_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B2F5CB3-1AE0-4905-A28B-090FDA56622E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mx67w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2529662-8A54-4DFC-80E7-922CF22DE2F3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mx68cw_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39884334-73AF-4E98-B05A-20FFF82B5DF1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mx68cw:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18E682AA-05AD-483F-915F-A2B2C98233B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_mx68w_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85EF67F0-973F-4FD1-8077-CE68D2AB1149",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_mx68w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03F9C184-3811-4A26-846D-54ECE7CF939F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_z3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "04CF5026-CC39-48FF-A8F0-8E31A425343E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_z3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB81CFD0-9558-47AB-96E4-CB21C1AA9159",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:meraki_z3c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F97974E-3C2B-49DB-A0FA-B5FEE7C98B18",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:meraki_z3c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6646F004-E0E0-4316-A022-2793C28FBCCC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_board_55_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A0EF95-7CC5-4EE2-A5D8-803195F63F49",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_board_55:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6554B9F-CD89-49B4-B55A-510B1C881C4F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_board_55s_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68546316-D08D-4E0B-BDDE-BF6320B730EB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_board_55s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D0EC6FF-44F6-4033-BDAF-A396C2635D3F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_board_70_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85FDA9FB-BB79-4A60-B825-D68B3719BFE3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_board_70:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A85B502B-2F55-4CA5-9AAA-0CD5BBA45EB7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_board_70s_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5565DF04-82F3-40C7-8E82-44A0DA72398B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_board_70s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "15073B83-81ED-4E98-8521-1320F8120C3F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_board_85s_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CA125CA-2BF9-4F22-8F8B-DC2E09A19E51",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_board_85s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31842684-B05D-4E17-9229-EC6993E78612",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_dx70_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69224767-0E2B-4A85-A7F1-77C6B41668DE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_dx70:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5EEB693F-64A4-46CC-B7AB-8BC0AA84F9E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_dx80_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "53BE3D06-730E-44E2-B3B0-ED29AB5D1BF1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_dx80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C17B385C-68D5-4FF5-AE40-6EDA46E3ACB7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_55_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "90095155-ABC0-43C9-896A-55A797EC2055",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_55:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A983D4D-9E04-45CE-BE3C-9FCD0018837F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_55_dual_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E5ABF29-B908-4A43-B3CC-9145721727A9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_55_dual:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A36CB8A-C74F-46B4-BFCE-523488D33B93",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_70_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA1BD59F-078D-45D2-AC39-C479A4C6E7CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_70:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD45F341-FAD8-4B10-B28C-8697E51C6B61",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_70_dual_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB5631A8-0201-432E-9912-B99D44D757DB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_70_dual:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BB2955F-2C82-4668-8C0B-412BEFE0E09E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_70_dual_g2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A16E007C-A310-474D-8174-EC98FEDDCE76",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_70_dual_g2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40E028E3-2DEB-4015-9BB0-97413DE60A47",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_70_single_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CCE92390-9835-4556-A439-5A6FE108A9AB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_70_single:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B47AE71-CF1B-402B-BB60-645A856A632D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_70_single_g2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BEB8DBF7-428A-42D4-8D52-8FF1329D3A56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_70_single_g2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C05259D-1F6C-440C-BCF4-A87BCC2EEA81",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_kit_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3610C3BC-6994-443F-BD27-0D11293C4079",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_kit:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AD5AD81-0976-483E-AA31-6D53A63A8D90",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:cisco:webex_room_kit_mini_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31D7CC29-6916-4A75-86DE-0BC4FBA3A639",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:cisco:webex_room_kit_mini:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D320D1AC-EAA7-45FD-B932-FC9554934BC1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:ac_8260_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "28B0DBF3-63BB-40EF-9D46-E32D074D73DA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:ac_8260:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5A8F30C-6BB7-4CC6-ADBE-1859DAF66C58",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:ac_8265_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E5ADC21-F308-4CAA-8E98-4E7FDC7EDAAC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:ac_8265:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C08E2F3E-C4B5-4227-A88D-C50E209A12CF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:ac_9260_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2915178-6BB6-45EE-A19D-EDB5B78F2BE2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:ac_9260:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C2795E42-D044-4D48-BCB2-61CC1A3471B1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:ac_9560_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7154EAF0-2E61-4813-B443-C4556137EB4D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:ac_9560:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D382D4A1-C8FD-4B47-B2C4-145232EC8AC5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:killer_ac_1550_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7262E71-08D0-4F5E-8445-1FA0E2243340",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:killer_ac_1550:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA05D5D2-F6C1-4FBB-B334-73F30F108562",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:killer_wi-fi_6_ax1650_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD2249BC-F119-471D-9D71-4690A65A1020",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:killer_wi-fi_6_ax1650:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E239C04-1D6B-4305-9340-BFEC3E54E19A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:killer_wi-fi_6e_ax1675_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CA43945-7F16-4A50-9E25-D91EE4A270F1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:killer_wi-fi_6e_ax1675:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35F09C95-25BD-440A-AD79-8510E54F8DD9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_3165_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "662CE728-C754-465B-A4AC-E63D5115EFC4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_3165:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C527CEB1-3D59-4ACD-B67F-B3919AFCE54C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_3168_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "160C541B-2617-4199-914D-ECE3A0791397",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_3168:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA1FA4A0-728B-4DB1-BA3C-CA80ECBA8624",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_8260_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9C7F70F-207C-4D8C-8C3E-08C7772810F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_8260:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7638C7-6F12-4C10-8B6D-5F866950CA05",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_8265_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA4C0E13-8027-4375-AA26-764DAD7E3C9B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_8265:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CDDDE40-5D30-49AF-91C0-9A4FA7741201",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_9260_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30A4744B-DA96-4614-AA99-9198A6D4C442",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_9260:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09145915-AFD1-4D5D-8178-8571C43A0BA5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_9461_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63756272-F713-4249-91C2-F29A382C63A6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_9461:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1950BF4-323D-4A25-A645-3ED60ED6F3AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_9462_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EFDF863-4FB2-4D21-8744-A82A7C0EAA76",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_9462:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "28157739-A073-4B01-B308-470841344A2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_ac_9560_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "42D55365-A759-4F72-B85D-5C13710F2AF6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_ac_9560:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "52B5EF48-BA3E-470C-9C68-12CEF8EFF045",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_wi-fi_6_ax200_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8531052-3602-4309-93A9-CA7020EF95F4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_wi-fi_6_ax200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB9FC918-AC9F-4C15-8404-1C2E8DC506A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_wi-fi_6_ax201_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB831D03-30CD-4218-9E69-13FC12115805",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_wi-fi_6_ax201:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5A7944D-2BB4-47A9-A2F5-AB68A9FC8C70",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_wi-fi_6e_ax210_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "049297F7-84C0-4AD0-8806-AA41AC02CEAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_wi-fi_6e_ax210:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77EADB2D-F10B-40A9-A938-A89EE0FEFF60",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:proset_wireless_7265_\\(rev_d\\)_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2C67C7D-DA10-47A7-8407-5624981DFBE8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:proset_wireless_7265_\\(rev_d\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BFF8901-DEFF-4D08-8692-571682DE8582",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:wi-fi_6_ax200_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55FD8273-3968-4A85-A4FF-00CCE3B89C25",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:wi-fi_6_ax200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D653F9C-5B2E-400F-8F50-BFE466F08F0E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:intel:wi-fi_6_ax201_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2DF0C27-886C-48F8-83DA-85BE0F239DD3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:intel:wi-fi_6_ax201:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0433774-9479-4A01-B697-1379AEA223C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 un problema en el controlador ALFA de Windows 10 versi\u00f3n 6.1316.1209 para AWUS036H. Las implementaciones WEP, WPA, WPA2 y WPA3 aceptan tramas de texto plano en una red Wi-Fi protegida. Un adversario puede abusar de esto para inyectar tramas de datos arbitrarias independientes de la configuraci\u00f3n de la red"
    }
  ],
  "id": "CVE-2020-26140",
  "lastModified": "2024-11-21T05:19:20.550",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 3.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-11T20:15:08.687",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/05/11/12"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.fragattacks.com"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/05/11/12"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.fragattacks.com"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-327"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-12-13 16:15
Modified
2025-01-14 11:15
Summary
Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system.
Impacted products
Vendor Product Version
siemens ruggedcom_rm1224_lte\(4g\)_eu_firmware *
siemens ruggedcom_rm1224_lte\(4g\)_eu -
siemens ruggedcom_rm1224_lte\(4g\)_nam_firmware *
siemens ruggedcom_rm1224_lte\(4g\)_nam -
siemens scalance_m804pb_firmware *
siemens scalance_m804pb -
siemens scalance_m812-1_adsl-router_firmware *
siemens scalance_m812-1_adsl-router -
siemens scalance_m816-1_adsl-router_firmware *
siemens scalance_m816-1_adsl-router -
siemens scalance_m826-2_shdsl-router_firmware *
siemens scalance_m826-2_shdsl-router -
siemens scalance_m874-2_firmware *
siemens scalance_m874-2 -
siemens scalance_m874-3_firmware *
siemens scalance_m874-3 -
siemens scalance_m876-3_firmware *
siemens scalance_m876-3 -
siemens scalance_m876-4_firmware *
siemens scalance_m876-4 -
siemens scalance_mum853-1_firmware *
siemens scalance_mum853-1 -
siemens scalance_mum856-1_firmware *
siemens scalance_mum856-1 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_s615_eec_firmware *
siemens scalance_s615_eec -
siemens scalance_sc622-2c_firmware *
siemens scalance_sc622-2c -
siemens scalance_sc626-2c_firmware *
siemens scalance_sc626-2c -
siemens scalance_sc632-2c_firmware *
siemens scalance_sc632-2c -
siemens scalance_sc636-2c_firmware *
siemens scalance_sc636-2c -
siemens scalance_sc642-2c_firmware *
siemens scalance_sc642-2c -
siemens scalance_sc646-2c_firmware *
siemens scalance_sc646-2c -
siemens scalance_w721-1_rj45_firmware *
siemens scalance_w721-1_rj45 -
siemens scalance_w722-1_rj45_firmware *
siemens scalance_w722-1_rj45 -
siemens scalance_w734-1_rj45_firmware *
siemens scalance_w734-1_rj45 -
siemens scalance_w738-1_m12_firmware *
siemens scalance_w738-1_m12 -
siemens scalance_w748-1_m12_firmware *
siemens scalance_w748-1_m12 -
siemens scalance_w761-1_rj45_firmware -
siemens scalance_w761-1_rj45 -
siemens scalance_w774-1_m12_eec_firmware -
siemens scalance_w774-1_m12_eec -
siemens scalance_w774-1_m12_rj45_firmware -
siemens scalance_w774-1_m12_rj45 -
siemens scalance_w774-1_rj45_firmware -
siemens scalance_w774-1_rj45 -
siemens scalance_w778-1_m12_firmware -
siemens scalance_w778-1_m12 -
siemens scalance_w778-1_m12_eec_firmware -
siemens scalance_w778-1_m12_eec -
siemens scalance_w786-1_rj45_firmware -
siemens scalance_w786-1_rj45 -
siemens scalance_w786-2_rj45_firmware -
siemens scalance_w786-2_rj45 -
siemens scalance_w786-2_sfp_firmware -
siemens scalance_w786-2_sfp -
siemens scalance_w786-2ia_rj45_firmware -
siemens scalance_w786-2ia_rj45 -
siemens scalance_w788-1_m12_firmware -
siemens scalance_w788-1_m12 -
siemens scalance_w788-1_rj45_firmware -
siemens scalance_w788-1_rj45 -
siemens scalance_w788-2_m12_firmware -
siemens scalance_w788-2_m12 -
siemens scalance_w788-2_m12_eec_firmware -
siemens scalance_w788-2_m12_eec -
siemens scalance_w1748-1_m12_firmware -
siemens scalance_w1748-1_m12 -
siemens scalance_w1788-1_m12_firmware -
siemens scalance_w1788-1_m12 -
siemens scalance_w1788-2_eec_m12_firmware -
siemens scalance_w1788-2_eec_m12 -
siemens scalance_w1788-2_m12_firmware -
siemens scalance_w1788-2_m12 -
siemens scalance_w1788-2ia_m12_firmware -
siemens scalance_w1788-2ia_m12 -
siemens scalance_wam763-1_firmware -
siemens scalance_wam763-1 -
siemens scalance_wam766-1_firmware -
siemens scalance_wam766-1 -
siemens scalance_wam766-1_6ghz_firmware -
siemens scalance_wam766-1_6ghz -
siemens scalance_wam766-1_ecc_firmware -
siemens scalance_wam766-1_ecc -
siemens scalance_wum763-1_firmware -
siemens scalance_wum763-1 -
siemens scalance_wum766-1_firmware -
siemens scalance_wum766-1 -
siemens scalance_wum766-1_6ghz_firmware -
siemens scalance_wum766-1_6ghz -
siemens scalance_xb205-3_firmware -
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware -
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware -
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware -
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware -
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware -
siemens scalance_xb216 -
siemens scalance_xc206-2_firmware -
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe_firmware -
siemens scalance_xc206-2g_poe -
siemens scalance_xc206-2g_poe_eec_firmware -
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_firmware -
siemens scalance_xc206-2sfp -
siemens scalance_xc206-2sfp_eec_firmware -
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware -
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_eec_firmware -
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware -
siemens scalance_xc208 -
siemens scalance_xc208_eec_firmware -
siemens scalance_xc208_eec -
siemens scalance_xc208_poe_firmware -
siemens scalance_xc208_poe -
siemens scalance_xc216_firmware -
siemens scalance_xc216 -
siemens scalance_xc216-3g_poe_firmware -
siemens scalance_xc216-3g_poe -
siemens scalance_xc216-4c_firmware -
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware -
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_eec_firmware -
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware -
siemens scalance_xc216eec -
siemens scalance_xc224_firmware -
siemens scalance_xc224 -
siemens scalance_xc224-4c_g_firmware -
siemens scalance_xc224-4c_g -
siemens scalance_xc224-4c_g_eec_firmware -
siemens scalance_xc224-4c_g_eec -
siemens scalance_xf204_firmware -
siemens scalance_xf204 -
siemens scalance_xf204_dna_firmware -
siemens scalance_xf204_dna -
siemens scalance_xf204-2ba_firmware -
siemens scalance_xf204-2ba -
siemens scalance_xf204-2bca_dna_firmware -
siemens scalance_xf204-2bca_dna -
siemens scalance_xm408-4c_firmware -
siemens scalance_xm408-4c -
siemens scalance_xm408-8c_firmware -
siemens scalance_xm408-8c -
siemens scalance_xm416-4c_firmware -
siemens scalance_xm416-4c -
siemens scalance_xp208_firmware -
siemens scalance_xp208 -
siemens scalance_xp208eec_firmware -
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware -
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware -
siemens scalance_xp216 -
siemens scalance_xp216eec_firmware -
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware -
siemens scalance_xp216poe_eec -
siemens scalance_xr324wg_firmware -
siemens scalance_xr324wg -
siemens scalance_xr326-2c_firmware -
siemens scalance_xr326-2c -
siemens scalance_xr326-2c_poe_firmware -
siemens scalance_xr326-2c_poe -
siemens scalance_xr328-4c_wg_firmware -
siemens scalance_xr328-4c_wg -
siemens scalance_xr524-8c_firmware -
siemens scalance_xr524-8c -
siemens scalance_xr526-8c_firmware -
siemens scalance_xr526-8c -
siemens scalance_xr528-6m_firmware -
siemens scalance_xr528-6m -
siemens scalance_xr552-12m_firmware -
siemens scalance_xr552-12m -
siemens siplus_net_scalance_xc206-2_firmware -
siemens siplus_net_scalance_xc206-2 -
siemens siplus_net_scalance_xc206-2sfp_firmware -
siemens siplus_net_scalance_xc206-2sfp -
siemens siplus_net_scalance_xc208_firmware -
siemens siplus_net_scalance_xc208 -
siemens siplus_net_scalance_xc216-4c_firmware -
siemens siplus_net_scalance_xc216-4c -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\(4g\\)_eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DFAA9A1-FE88-4F1C-92F3-2D4DCE3CC67E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rm1224_lte\\(4g\\)_eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03D8CF59-D9D4-4C50-A6E6-D6B5BDB31AEC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\(4g\\)_nam_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6ADBD53E-B345-4557-B595-23A17E56705D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rm1224_lte\\(4g\\)_nam:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "400ACE99-AF15-4C20-9A6D-F8584DA5C7CE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m804pb_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21328784-AF25-4714-B533-7BEF16986E19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6EBA42A-93FF-4883-8626-EF78D38374D3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m812-1_adsl-router_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "63CB925E-301E-4ABA-A8D5-8089A7F2874D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m812-1_adsl-router:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "451B1162-CCDE-4658-86B7-DF98468B2721",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m816-1_adsl-router_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FDD3DB2-8ACC-4039-A134-458771460501",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m816-1_adsl-router:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "80BE81AD-F440-4009-A33F-DBE957C3CDD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m826-2_shdsl-router_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "22188289-5FC8-418D-9077-B42F05A2468F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m826-2_shdsl-router:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39951670-CF88-460C-B1D5-6DCFBC7F573D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m874-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A3C8086-4B67-4609-A239-8A606CBC5285",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m874-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C933ED27-2206-4734-8EB8-6A6431D1FBF1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m874-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C186B14-DCBF-43CD-BE7D-2ED72EF6E3C3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m874-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3258DC7-0461-4C65-8292-85C9965EA83D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m876-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEDC7F0A-7AD7-464E-83E2-B433EF076C0C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m876-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD221BA9-3448-49E4-B3A3-D88B939785AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m876-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA2495A6-4AE8-4FD6-8B86-378DD542C59B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m876-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "94E4CCE9-71F7-4960-B7DE-5298EFB7C619",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_mum853-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F71C564-F2D8-4141-A009-C73144973491",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_mum853-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F56875A-B2B3-471F-ADAC-574C55E1D86A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_mum856-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B363B81A-2F6D-4720-83A1-44604125B8CE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_mum856-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "17BEBCAB-D640-4F6D-9579-4A54C76D80F8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EF65A06-2222-47D2-83B5-4C61E6D8731E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "065E9A4C-2F3B-4C13-976C-E8DF4630580F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA5D94EA-C407-446F-B98F-F647ACBBA010",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5984E86-2A83-4927-80E1-62FC75E72C48",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc622-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50FEE5FA-B141-4E5F-8673-363089262530",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc626-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F3AAA53-4DC8-49B7-B77C-DC6759652461",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc626-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EAC3EE40-4398-4337-B40E-8AACDF225BBF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8020D902-3489-4898-A676-C262B0DB4653",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc632-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A79836B-5EC1-40AF-8A57-9657EF6758E5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FDFD39B-1E20-4735-833B-9A89B171C560",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc636-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCB9BD17-7F1F-42E9-831F-EB907F9BC214",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C5ADD89C-22C7-45CA-AE2D-1BF63CE6CF97",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc642-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "10C7D54A-27B4-4195-8131-DD5380472A75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "656082A8-8160-4A1A-967B-F7CC27A218D5",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc646-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E54AF1E6-0E52-447C-8946-18716D30EBE2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w721-1_rj45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64D0557E-2677-496D-ADC6-A43164499217",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w721-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DABF73D6-D438-4417-A626-A73E84CA7355",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w722-1_rj45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BDC42FA-2A49-4494-A678-DCAA363E41B7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w722-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBB3AC0B-8A73-420D-A5BE-B5FB105BD289",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w734-1_rj45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A20C962-DC09-4B5A-873F-4CEAA00C41BA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w734-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50B58BD7-3B5E-458E-BEB7-EFDC0336454A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w738-1_m12_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD191B35-A96B-4C62-8BBD-F997C658D5D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w738-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8600D53-1137-40C0-9D6E-A9BC87B3697B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w748-1_m12_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "97BE6180-2176-40B2-B73B-8E988728A459",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w748-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F67ECC31-7B5A-4716-B9CF-B3A2AB7D3809",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w761-1_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B763B9EF-C23C-4724-8F7B-54EA8295BF8B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w761-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "37A6BD90-9E5B-4828-8B05-E7D18C2D7694",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_m12_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5BAD55E-A127-49CF-A34A-B86A09BB6781",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1_m12_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7F9461B-4089-48E6-AA46-72D53BFC1A2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_m12_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E6DB76A-1F8C-40A7-AD9E-7448FB864529",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1_m12_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B13194C7-B3C0-486B-9BB0-7380271AC51C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w774-1_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FDE9C73-A7AF-4994-8D5C-F49B22F65454",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w774-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C775EE0-4F09-40DB-83B4-010A4DA395A2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w778-1_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "412B05DB-DA86-488E-9818-BEA7358DA7E1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w778-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE028852-E293-41D4-8EA9-E7F4C187F383",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w778-1_m12_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12D1DBB7-76E7-4D73-A07A-700A6B44E27F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w778-1_m12_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F5D048A-D906-4AC2-B897-086916DB928C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-1_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F0C250C-5A86-4117-85DD-A86BC3CDBD49",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "96137F44-A487-4A37-BF35-0466F6B947EC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7670B731-0044-4D39-ACE9-4A8C70D481B8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "64140D18-45F0-4745-B204-D1904ECB7F2E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2_sfp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "504C7CBD-FD95-46B6-9AF2-FF9282C2C2F2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2_sfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "301FEDD1-21C9-42B4-ADAF-E97F7387F5E2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w786-2ia_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2BC32A8-3617-48DB-BC07-C683F55B94CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w786-2ia_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8598E40-4F23-47A6-B4B7-EEF168E0B528",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-1_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9B7DADC-7877-4668-B4E9-45B7A8CCB06A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49D960F5-A0D0-4410-A4FD-F0435B3DE3F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-1_rj45_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C90F8DD9-064C-4ECE-9A9D-9F1C0274B410",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-1_rj45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4706F058-B8C7-4A23-9C12-10D2CC0C3319",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-2_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3093E54-0D81-40E1-92F0-B15F4B03B97C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-2_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C095E360-53A0-4A9A-AD28-841CAE9B4862",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w788-2_m12_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FFC245C-6185-4477-B1CB-0AF9AFE7B6D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w788-2_m12_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E7B6FFF-7562-47DD-AEE0-36C119A178AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1748-1_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B4646E-7506-4A23-8833-2503192AD197",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1748-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2353650-D295-4A89-9CF2-50984BE0DD19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-1_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9804602-E66C-4E83-9995-D392ECBE1ABD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-1_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "408600B8-762D-43C9-A259-7163FA9DB788",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2_eec_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35B4452A-63DA-43ED-A987-FCD0F28D8F49",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2_eec_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8AE6F9AD-37DB-4067-8BB4-10CDD3AA8E23",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "70FF8CDC-EB85-4CE6-B2C7-ED138F9B9785",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8AA449C-52AE-4286-8BD2-C1A54A1AC64E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1788-2ia_m12_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "985AF207-0160-44FE-985D-0FA3A9248E87",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1788-2ia_m12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9491822-56EE-4065-B199-040BEE283ED0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam763-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7948D988-3ED9-49BE-B820-15728DA93D21",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam763-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AAE316D-6BA6-4C3F-9EE1-E23E4CB6FD19",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B465A44-EC90-41C6-BD9B-59D3B7E49540",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA96B540-439B-4A1A-9D7D-C45AEFBC7BE6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_6ghz_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5690A7D8-2B9F-4DBB-84A8-82B1A7C822B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1_6ghz:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA329302-48FE-43FB-A15D-C3BEFB5AE868",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wam766-1_ecc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "88B6E0DF-40E8-404A-97D4-24C249CB9947",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wam766-1_ecc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "87BF5178-0503-43DB-97C7-0C7852636FD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum763-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "534CF2AE-2149-4599-AC43-13EE8048B3EE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum763-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C501445F-BDF6-4A0A-85FD-E6BFBF0A3C6F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum766-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E95E358-45E9-40EC-B3A3-D65C4BA42CE7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum766-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EB15599-F795-4D24-A4A6-CD826F6A7A13",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_wum766-1_6ghz_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "441DF280-FC8C-481F-BDB9-7D757CF5BB72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_wum766-1_6ghz:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF8A9161-738C-4730-8EC9-6A5C5FDE279D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "741BF248-4BDF-4D25-8A0F-3584B8529051",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9F9F101-6042-4D11-98CE-16A996023B38",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "126369BE-5503-4F85-8652-AC03F2EE6D14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18DC9125-FC41-4BAB-9638-C42DEF40235B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb208_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D8B4FF5-6C20-41F5-A551-272B5FD84A26",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD92140A-AC7A-463D-99DC-E744A7192532",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B3F6874-3972-435C-89FB-66C9E2729699",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb216_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB116F11-7866-4E74-9037-549462578EA5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D83AF5-9770-43A9-91AE-15EB97A1ACCC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6091005D-A614-4304-94FE-2122D9BF5E00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D32A16B-7D10-4CC8-8E2D-B7B92FBE1E57",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "641699CC-03A4-4DF0-8B1F-EEB658C02E71",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A7D7D3-709A-4872-AC80-FC8EC4915A30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "804E37AB-9EE4-4931-A874-4FBD427252D1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C6E4046-3278-4FDF-84AF-B285905AFF17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC286693-55D6-4949-8164-262EB6C022C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "51F537D2-489A-420F-8167-C527E2ED506A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC7B235D-0141-46E5-9057-2203555AE58A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4AD0884E-98F8-4A67-BD85-AF92674B314C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED2CF432-441D-4707-8E4C-43AC51DF9422",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14FE1E7A-1E4A-4B11-983E-DC39859EAFF0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C54CBCC9-F19D-4993-9D32-8C8778B00E29",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc208_poe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C84F8238-18F5-4027-8727-5D999BB1650E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc208_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CD4E4B5-7F1E-4005-ACEF-7BD13623EBF9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCEBB0C5-16B2-4B3E-818F-E503A72D785B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-3g_poe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07910A99-B456-4E99-955F-4B08D100E3A2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-3g_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00518DEB-EE44-45AD-AA53-0BBEAF6D3996",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB57F678-CC82-4DF5-9A04-1C85D1B7F521",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25CA5DE7-8645-4DFA-8C2A-C23405FEBAAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78645734-50C1-4331-9FC4-AC8A8679B6AF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "163DDB2C-19D7-4A13-86D5-1258E3F66C3D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "323CEAEA-8122-43A5-BB87-97C7133FF510",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5196C590-7B02-4A9B-BDAC-0770E26498E1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BE498F8-A9D8-4A92-90CE-21BA30234947",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "333852F5-7EF8-41B8-A58D-CE8F00D525A1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4710338E-9449-4AF3-9C91-E7AF9549CA69",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9615F05-CD89-4CCB-B1FB-A76D067BCB15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29A2F221-42ED-4DC3-8D61-89D3545737FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE918926-B0F2-40E9-9453-6F0857543CF1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE51B288-0592-4360-BB83-27675DA261FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F1AE867-67B4-4871-BF56-88017533A737",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204_dna_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81A70627-A17F-4C66-B154-D1D585EFB08B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204_dna:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "70D62F13-AD59-435E-851A-87A0A6E2FA3B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55E6E20A-865B-4FC6-9727-5CB27707177A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EB2D91E-3DB2-4B89-8911-5323B2F0513F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf204-2bca_dna_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE62F317-6D74-4FAA-A12E-BFB229AD4AEC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf204-2bca_dna:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65F65152-F42B-4EDC-90A9-171023690CDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E69D335F-FBC9-4567-B68D-F616F761A609",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AA81823-013F-4990-B62D-86C404F04BCB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D36EF679-0355-4CEA-A247-EA266FEA0843",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7096DBA5-95BB-44D7-B7CA-B1845C87F70E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3850AC0-AC32-480D-B1BB-DE2E1E5A57E4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9102A41-5812-4014-BC07-E571E815ED49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E5FD7D0-770C-4D8E-AAC7-F0F752C57A45",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A75B5F6-B974-463C-BDB7-970982085EE7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B313A4C-D3E7-4964-BA51-3401546B36C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA9F6F24-B1C5-4808-A481-13B1312D01F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6E888EA-73A7-42B8-A617-621CF192F2A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "05515A80-76E4-44D5-B78E-33B07D505451",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4154797A-208E-426F-817A-050B4B96128B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12512EC4-FB7D-420F-9A8A-547562BE1B49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F9FCBCD-5546-4EAB-874A-64B3925287AC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr324wg_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50D00EA1-F24F-42C4-9A6B-48E1A572588B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E767C461-8FA6-4700-98CB-734AFD309140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr326-2c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1EBDED3-F7E0-4DC3-A477-1DD76106BBB8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr326-2c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1CFB380-CE6A-45FF-AF85-F145494D696B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr326-2c_poe_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "11593BD9-68E1-4860-A987-73366C06872D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr326-2c_poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "91A86897-0140-476D-BBD2-410E08279B70",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5495FD4E-3A57-4C49-99EA-6085DF1D1DBB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5B7DEDC-66BD-4701-BBDD-16273263ADC9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D8E2D30-DDA9-4C2E-A06A-428A42AEF849",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31168EC3-8073-4DB0-8E92-5E0A2780887F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49EA2944-E702-4BF4-B6AD-BF6A737EA866",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12m_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C4B71459-24D4-4351-BF66-2BB246FF279E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A806691-3F4B-46AA-9718-2F6BF0FD3D7A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_xc206-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C763CFC2-4001-4200-B975-FF1B26F157CE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_xc206-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3296F8-1159-4A4F-B106-43216C55737D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_xc206-2sfp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF228885-3028-4525-A320-CE62818567CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "66C7B087-CAE4-42BC-AAA3-99976870539F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_xc208_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BB380B7-A3BF-4D5C-9113-FC07E3C807DB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_xc208:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AC043E2-1DAB-4CF2-B024-88BC6B6B0C89",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_net_scalance_xc216-4c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C35A45E9-BDC8-496A-9E00-6726A99434E0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_net_scalance_xc216-4c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D52CD11-7965-4864-88BB-76CD31977266",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system."
    },
    {
      "lang": "es",
      "value": "Los dispositivos afectados utilizan un esquema de cifrado d\u00e9bil para cifrar el archivo zip de depuraci\u00f3n. Esto podr\u00eda permitir a un atacante autenticado descifrar el contenido del archivo y recuperar informaci\u00f3n de depuraci\u00f3n sobre el sistema."
    }
  ],
  "id": "CVE-2022-46140",
  "lastModified": "2025-01-14T11:15:10.960",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "NONE",
          "vulnerableSystemConfidentiality": "HIGH",
          "vulnerableSystemIntegrity": "NONE"
        },
        "source": "productcert@siemens.com",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-12-13T16:15:25.007",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-327"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-327"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2022-46140
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2025-01-14 10:27
Summary
Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) EU Version: 0   < V7.2
Create a notification for this product.
   Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M804PB Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M826-2 SHDSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M874-2 Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M874-3 Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-3 Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-3 (ROK) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-4 Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-4 (EU) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-4 (NAM) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE MUM853-1 (EU) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (EU) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (RoW) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE S615 EEC LAN-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE S615 LAN-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE SC622-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC626-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC632-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC636-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC642-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC646-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1788-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1788-2 EEC M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1788-2 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1788-2IA M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 (USA) Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 (USA) Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC (USA) Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE WAM763-1 Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 (US) Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC (US) Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 (USA) Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE XB205-3 (SC, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB208 (E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB208 (PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB216 (E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB216 (PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2 (SC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2 (ST/BFOC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE (54 V DC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G (EIP def.) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G PoE Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G PoE (54 V DC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE (54 V DC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G (EIP Def.) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G (EIP Def.) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204 DNA Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204-2BA Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204-2BA DNA Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XM408-4C Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-4C (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-8C Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-8C (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM416-4C Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM416-4C (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XP208 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208 (Ethernet/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208PoE EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216 (Ethernet/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216POE EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG (without UL) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.6
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2 Version: 0   < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2SFP Version: 0   < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC208 Version: 0   < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC216-4C Version: 0   < V4.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:24:03.297Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T10:27:03.863Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-46140",
    "datePublished": "2022-12-13T00:00:00",
    "dateReserved": "2022-11-28T00:00:00",
    "dateUpdated": "2025-01-14T10:27:03.863Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-24588
Vulnerability from cvelistv5
Published
2021-05-11 00:00
Modified
2024-08-04 15:19
Severity ?
Summary
The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn't require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary can abuse this to inject arbitrary network packets.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:19:08.467Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00473.html"
          },
          {
            "name": "20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.fragattacks.com"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"
          },
          {
            "name": "[oss-security] 20210511 various 802.11 security issues - fragattacks.com",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2021/05/11/12"
          },
          {
            "name": "[debian-lts-announce] 20210623 [SECURITY] [DLA 2689-1] linux security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2021/06/msg00020.html"
          },
          {
            "name": "[debian-lts-announce] 20210623 [SECURITY] [DLA 2690-1] linux-4.19 security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2021/06/msg00019.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"
          },
          {
            "name": "[debian-lts-announce] 20230401 [SECURITY] [DLA 3380-1] firmware-nonfree LTS new upstream version (security updates and newer firmware for Linux 5.10)",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2023/04/msg00002.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn\u0027t require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary can abuse this to inject arbitrary network packets."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-01T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00473.html"
        },
        {
          "name": "20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"
        },
        {
          "url": "https://www.fragattacks.com"
        },
        {
          "url": "https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"
        },
        {
          "name": "[oss-security] 20210511 various 802.11 security issues - fragattacks.com",
          "tags": [
            "mailing-list"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/05/11/12"
        },
        {
          "name": "[debian-lts-announce] 20210623 [SECURITY] [DLA 2689-1] linux security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/06/msg00020.html"
        },
        {
          "name": "[debian-lts-announce] 20210623 [SECURITY] [DLA 2690-1] linux-4.19 security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/06/msg00019.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"
        },
        {
          "url": "https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"
        },
        {
          "name": "[debian-lts-announce] 20230401 [SECURITY] [DLA 3380-1] firmware-nonfree LTS new upstream version (security updates and newer firmware for Linux 5.10)",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2023/04/msg00002.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-24588",
    "datePublished": "2021-05-11T00:00:00",
    "dateReserved": "2020-08-21T00:00:00",
    "dateUpdated": "2024-08-04T15:19:08.467Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-26140
Vulnerability from cvelistv5
Published
2021-05-11 19:34
Modified
2024-08-04 15:49
Severity ?
Summary
An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:49:07.137Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.fragattacks.com"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"
          },
          {
            "name": "[oss-security] 20210511 various 802.11 security issues - fragattacks.com",
            "tags": [
              "mailing-list",
              "x_refsource_MLIST",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2021/05/11/12"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-10-28T14:11:58",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.fragattacks.com"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"
        },
        {
          "name": "[oss-security] 20210511 various 802.11 security issues - fragattacks.com",
          "tags": [
            "mailing-list",
            "x_refsource_MLIST"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/05/11/12"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-26140",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20210511 Multiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 2021",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-wifi-faf-22epcEWu"
            },
            {
              "name": "https://www.fragattacks.com",
              "refsource": "MISC",
              "url": "https://www.fragattacks.com"
            },
            {
              "name": "https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md",
              "refsource": "MISC",
              "url": "https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md"
            },
            {
              "name": "[oss-security] 20210511 various 802.11 security issues - fragattacks.com",
              "refsource": "MLIST",
              "url": "http://www.openwall.com/lists/oss-security/2021/05/11/12"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf"
            },
            {
              "name": "https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63",
              "refsource": "MISC",
              "url": "https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-26140",
    "datePublished": "2021-05-11T19:34:42",
    "dateReserved": "2020-09-29T00:00:00",
    "dateUpdated": "2024-08-04T15:49:07.137Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-46142
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2025-01-14 10:27
Summary
Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) EU Version: 0   < V7.2
Create a notification for this product.
   Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M804PB Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M826-2 SHDSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M874-2 Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M874-3 Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-3 Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-3 (ROK) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-4 Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-4 (EU) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-4 (NAM) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE MUM853-1 (EU) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (EU) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (RoW) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE S615 EEC LAN-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE S615 LAN-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE SC622-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC622-2C Version: V2.3   < V3.0
Create a notification for this product.
   Siemens SCALANCE SC626-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC626-2C Version: V2.3   < V3.0
Create a notification for this product.
   Siemens SCALANCE SC632-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC632-2C Version: V2.3   < V3.0
Create a notification for this product.
   Siemens SCALANCE SC636-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC636-2C Version: V2.3   < V3.0
Create a notification for this product.
   Siemens SCALANCE SC642-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC642-2C Version: V2.3   < V3.0
Create a notification for this product.
   Siemens SCALANCE SC646-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC646-2C Version: V2.3   < V3.0
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1788-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1788-2 EEC M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1788-2 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1788-2IA M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 (USA) Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 (USA) Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC (USA) Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE WAM763-1 Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 (US) Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC (US) Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 (USA) Version: 0   < V2.0.0
Create a notification for this product.
   Siemens SCALANCE XB205-3 (SC, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB208 (E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB208 (PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB216 (E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB216 (PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2 (SC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2 (ST/BFOC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE (54 V DC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G (EIP def.) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G PoE Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G PoE (54 V DC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE (54 V DC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G (EIP Def.) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G (EIP Def.) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204 DNA Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204-2BA Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204-2BA DNA Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XM408-4C Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-4C (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-8C Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-8C (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM416-4C Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM416-4C (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XP208 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208 (Ethernet/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208PoE EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216 (Ethernet/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216POE EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG (without UL) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.6
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2 Version: 0   < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2SFP Version: 0   < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC208 Version: 0   < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC216-4C Version: 0   < V4.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:24:03.321Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.2,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-257",
              "description": "CWE-257: Storing Passwords in a Recoverable Format",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T10:27:07.533Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-46142",
    "datePublished": "2022-12-13T00:00:00",
    "dateReserved": "2022-11-28T00:00:00",
    "dateUpdated": "2025-01-14T10:27:07.533Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-46143
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2025-01-14 10:27
Summary
Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) EU Version: 0   < V7.2
Create a notification for this product.
   Siemens RUGGEDCOM RM1224 LTE(4G) EU Version: 0   < V8.0
Create a notification for this product.
   Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: 0   < V7.2
Create a notification for this product.
   Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M804PB Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M804PB Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M826-2 SHDSL-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M826-2 SHDSL-Router Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M874-2 Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M874-2 Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M874-3 Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M874-3 Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M876-3 Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-3 Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M876-3 (ROK) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-3 (ROK) Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M876-4 Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-4 Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M876-4 (EU) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-4 (EU) Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE M876-4 (NAM) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE M876-4 (NAM) Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE MUM853-1 (EU) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE MUM853-1 (EU) Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (EU) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (EU) Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (RoW) Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (RoW) Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE S615 EEC LAN-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE S615 EEC LAN-Router Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE S615 LAN-Router Version: 0   < V7.2
Create a notification for this product.
   Siemens SCALANCE S615 LAN-Router Version: 0   < V8.0
Create a notification for this product.
   Siemens SCALANCE SC622-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC622-2C Version: V2.3   < V3.0
Create a notification for this product.
   Siemens SCALANCE SC626-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC626-2C Version: V2.3   < V3.0
Create a notification for this product.
   Siemens SCALANCE SC632-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC632-2C Version: V2.3   < V3.0
Create a notification for this product.
   Siemens SCALANCE SC636-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC636-2C Version: V2.3   < V3.0
Create a notification for this product.
   Siemens SCALANCE SC642-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC642-2C Version: V2.3   < V3.0
Create a notification for this product.
   Siemens SCALANCE SC646-2C Version: 0   < V2.3
Create a notification for this product.
   Siemens SCALANCE SC646-2C Version: V2.3   < V3.0
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1788-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1788-2 EEC M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1788-2 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W1788-2IA M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 (USA) Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 (USA) Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC (USA) Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: 0   < *
Create a notification for this product.
   Siemens SCALANCE WAB762-1 Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WAM763-1 Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WAM763-1 (ME) Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WAM763-1 (US) Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 (ME) Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 (US) Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC (ME) Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC (US) Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WUB762-1 Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WUB762-1 iFeatures Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 (US) Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 (US) Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 (ME) Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 (USA) Version: 0   < V3.0.0
Create a notification for this product.
   Siemens SCALANCE XB205-3 (SC, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB208 (E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB208 (PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB216 (E/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XB216 (PN) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2 (SC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2 (ST/BFOC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE (54 V DC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G (EIP def.) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G PoE Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G PoE (54 V DC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE (54 V DC) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G (EIP Def.) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G (EIP Def.) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204 DNA Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204-2BA Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204-2BA DNA Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XM408-4C Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-4C (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-8C Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-8C (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM416-4C Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XM416-4C (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XP208 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208 (Ethernet/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208PoE EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216 Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216 (Ethernet/IP) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216POE EEC Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG (without UL) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: 0   < V4.4
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: 0   < V6.6
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2 Version: 0   < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2SFP Version: 0   < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC208 Version: 0   < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC216-4C Version: 0   < V4.4
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:24:03.372Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W721-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W722-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W734-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W738-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W748-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W761-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W774-1 RJ45 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W778-1 M12 EEC (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2 SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W786-2IA RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-1 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 M12 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W788-2 RJ45",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUB762-1 iFeatures",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB205-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB208 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3 (ST, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB213-3LD (SC, PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (E/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB216 (PN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G (EIP def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC208G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-3G PoE (54 V DC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM408-8C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM416-4C (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216 (Ethernet/IP)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR326-2C PoE WG (without UL)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 24V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR528-6M (L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR552-12M (2HR2)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 2.7,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1284",
              "description": "CWE-1284: Improper Validation of Specified Quantity in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T10:27:11.064Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180704.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-180704.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-46143",
    "datePublished": "2022-12-13T00:00:00",
    "dateReserved": "2022-11-28T00:00:00",
    "dateUpdated": "2025-01-14T10:27:11.064Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}