Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    12 vulnerabilities found for netmodule_router_software by netmodule

    CVE-2023-46306 (GCVE-0-2023-46306)

    Vulnerability from nvd – Published: 2023-10-22 00:00 – Updated: 2024-09-12 18:22
    VLAI
    Summary
    The web administration interface in NetModule Router Software (NRSW) 4.6 before 4.6.0.106 and 4.8 before 4.8.0.101 executes an OS command constructed with unsanitized user input: shell metacharacters in the /admin/gnssAutoAlign.php device_id parameter. This occurs because another thread can be started before the trap that triggers the cleanup function. A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges. NOTE: this is different from CVE-2023-0861 and CVE-2023-0862, which were fixed in version 4.6.0.105.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    netmodule netmodule_router_software Affected: 4.6.0.0 , < 4.6.0.106 (custom)
        cpe:2.3:a:netmodule:netmodule_router_software:4.6.0.0:*:*:*:*:*:*:*
    Create a notification for this product.
    netmodule netmodule_router_software Affected: 4.8 , < 4.8.0.101 (custom)
        cpe:2.3:a:netmodule:netmodule_router_software:4.8:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:45:40.734Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://share.netmodule.com/public/system-software/4.8/4.8.0.101/NRSW-RN-4.8.0.101.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://share.netmodule.com/public/system-software/4.6/4.6.0.106/NRSW-RN-4.6.0.106.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://pentest.blog/advisory-netmodule-router-software-race-condition-leads-to-remote-code-execution/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:netmodule:netmodule_router_software:4.6.0.0:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "netmodule_router_software",
                "vendor": "netmodule",
                "versions": [
                  {
                    "lessThan": "4.6.0.106",
                    "status": "affected",
                    "version": "4.6.0.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:netmodule:netmodule_router_software:4.8:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "netmodule_router_software",
                "vendor": "netmodule",
                "versions": [
                  {
                    "lessThan": "4.8.0.101",
                    "status": "affected",
                    "version": "4.8",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46306",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-12T18:17:05.575956Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-12T18:22:55.873Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The web administration interface in NetModule Router Software (NRSW) 4.6 before 4.6.0.106 and 4.8 before 4.8.0.101 executes an OS command constructed with unsanitized user input: shell metacharacters in the /admin/gnssAutoAlign.php device_id parameter. This occurs because another thread can be started before the trap that triggers the cleanup function. A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges. NOTE: this is different from CVE-2023-0861 and CVE-2023-0862, which were fixed in version 4.6.0.105."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-22T20:07:16.731Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://share.netmodule.com/public/system-software/4.8/4.8.0.101/NRSW-RN-4.8.0.101.pdf"
            },
            {
              "url": "https://share.netmodule.com/public/system-software/4.6/4.6.0.106/NRSW-RN-4.6.0.106.pdf"
            },
            {
              "url": "https://pentest.blog/advisory-netmodule-router-software-race-condition-leads-to-remote-code-execution/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-46306",
        "datePublished": "2023-10-22T00:00:00.000Z",
        "dateReserved": "2023-10-22T00:00:00.000Z",
        "dateUpdated": "2024-09-12T18:22:55.873Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-0862 (GCVE-0-2023-0862)

    Vulnerability from nvd – Published: 2023-02-16 09:07 – Updated: 2025-03-18 14:50
    VLAI
    Title
    Path Traversal in NetModule NSRW
    Summary
    The NetModule NSRW web administration interface is vulnerable to path traversals, which could lead to arbitrary file uploads and deletion. By uploading malicious files to the web root directory, authenticated users could gain remote command execution with elevated privileges. This issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    Impacted products
    Vendor Product Version
    NetModule NSRW Affected: 4.3.0.0 , < 4.3.0.119 (4.3.0.119)
    Affected: 4.4.0.0 , < 4.4.0.118 (4.4.0.118)
    Affected: 4.6.0.0 , < 4.6.0.105 (4.6.0.105)
    Affected: 4.7.0.0 , < 4.7.0.103 (4.7.0.103)
    Create a notification for this product.
    Date Public
    2023-02-16 09:00
    Credits
    Quentin Kaiser from ONEKEY Research Labs
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:24:34.659Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://share.netmodule.com/public/system-software/4.7/4.7.0.103/NRSW-RN-4.7.0.103.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://onekey.com/blog/security-advisory-netmodule-multiple-vulnerabilities/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-0862",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-18T14:50:33.476944Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-18T14:50:42.840Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "web administration interface"
              ],
              "product": "NSRW",
              "vendor": "NetModule",
              "versions": [
                {
                  "lessThan": "4.3.0.119",
                  "status": "affected",
                  "version": "4.3.0.0",
                  "versionType": "4.3.0.119"
                },
                {
                  "lessThan": "4.4.0.118",
                  "status": "affected",
                  "version": "4.4.0.0",
                  "versionType": "4.4.0.118"
                },
                {
                  "lessThan": "4.6.0.105",
                  "status": "affected",
                  "version": "4.6.0.0",
                  "versionType": "4.6.0.105"
                },
                {
                  "lessThan": "4.7.0.103",
                  "status": "affected",
                  "version": "4.7.0.0",
                  "versionType": "4.7.0.103"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Quentin Kaiser from ONEKEY Research Labs"
            }
          ],
          "datePublic": "2023-02-16T09:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The NetModule NSRW web administration interface is vulnerable to path traversals, which could lead to arbitrary file uploads and deletion. By uploading malicious files to the web root directory, authenticated users could gain remote command execution with elevated privileges.\u003cbr\u003e\u003cbr\u003eThis issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.\u003cbr\u003e"
                }
              ],
              "value": "The NetModule NSRW web administration interface is vulnerable to path traversals, which could lead to arbitrary file uploads and deletion. By uploading malicious files to the web root directory, authenticated users could gain remote command execution with elevated privileges.\n\nThis issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-21T08:24:22.762Z",
            "orgId": "2d533b80-6e4a-4e20-93e2-171235122846",
            "shortName": "ONEKEY"
          },
          "references": [
            {
              "url": "https://share.netmodule.com/public/system-software/4.7/4.7.0.103/NRSW-RN-4.7.0.103.pdf"
            },
            {
              "url": "https://onekey.com/blog/security-advisory-netmodule-multiple-vulnerabilities/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Path Traversal in NetModule NSRW",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2d533b80-6e4a-4e20-93e2-171235122846",
        "assignerShortName": "ONEKEY",
        "cveId": "CVE-2023-0862",
        "datePublished": "2023-02-16T09:07:09.930Z",
        "dateReserved": "2023-02-16T09:01:36.192Z",
        "dateUpdated": "2025-03-18T14:50:42.840Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-0861 (GCVE-0-2023-0861)

    Vulnerability from nvd – Published: 2023-02-16 08:58 – Updated: 2025-03-18 14:54
    VLAI
    Title
    Authenticated Command Injection in NetModule NSRW
    Summary
    NetModule NSRW web administration interface executes an OS command constructed with unsanitized user input. A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges. This issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    NetModule NSRW Affected: 4.3.0.0 , < 4.3.0.119 (4.3.0.119)
    Affected: 4.4.0.0 , < 4.4.0.118 (4.4.0.118)
    Affected: 4.6.0.0 , < 4.6.0.105 (4.6.0.105)
    Affected: 4.7.0.0 , < 4.7.0.103 (4.7.0.103)
    Create a notification for this product.
    Date Public
    2023-02-16 09:00
    Credits
    Quentin Kaiser from ONEKEY Research Labs
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:24:34.694Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://share.netmodule.com/public/system-software/4.7/4.7.0.103/NRSW-RN-4.7.0.103.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://onekey.com/blog/security-advisory-netmodule-multiple-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-0861",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-18T14:54:45.830831Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-18T14:54:51.639Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "web administration interface"
              ],
              "platforms": [
                "Linux"
              ],
              "product": "NSRW",
              "vendor": "NetModule",
              "versions": [
                {
                  "lessThan": "4.3.0.119",
                  "status": "affected",
                  "version": "4.3.0.0",
                  "versionType": "4.3.0.119"
                },
                {
                  "lessThan": "4.4.0.118",
                  "status": "affected",
                  "version": "4.4.0.0",
                  "versionType": "4.4.0.118"
                },
                {
                  "lessThan": "4.6.0.105",
                  "status": "affected",
                  "version": "4.6.0.0",
                  "versionType": "4.6.0.105"
                },
                {
                  "lessThan": "4.7.0.103",
                  "status": "affected",
                  "version": "4.7.0.0",
                  "versionType": "4.7.0.103"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Quentin Kaiser from ONEKEY Research Labs"
            }
          ],
          "datePublic": "2023-02-16T09:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "NetModule NSRW web administration interface executes an OS command constructed with unsanitized user input.\u0026nbsp;A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges.\u003cbr\u003e\u003cp\u003eThis issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.\u003c/p\u003e"
                }
              ],
              "value": "NetModule NSRW web administration interface executes an OS command constructed with unsanitized user input.\u00a0A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges.\nThis issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.\n\n"
            }
          ],
          "exploits": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Proof-of-concept."
                }
              ],
              "value": "Proof-of-concept."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-21T08:24:45.882Z",
            "orgId": "2d533b80-6e4a-4e20-93e2-171235122846",
            "shortName": "ONEKEY"
          },
          "references": [
            {
              "url": "https://share.netmodule.com/public/system-software/4.7/4.7.0.103/NRSW-RN-4.7.0.103.pdf"
            },
            {
              "url": "https://onekey.com/blog/security-advisory-netmodule-multiple-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Authenticated Command Injection in NetModule NSRW",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2d533b80-6e4a-4e20-93e2-171235122846",
        "assignerShortName": "ONEKEY",
        "cveId": "CVE-2023-0861",
        "datePublished": "2023-02-16T08:58:43.370Z",
        "dateReserved": "2023-02-16T08:48:31.394Z",
        "dateUpdated": "2025-03-18T14:54:51.639Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-39291 (GCVE-0-2021-39291)

    Vulnerability from nvd – Published: 2021-08-23 04:37 – Updated: 2024-08-04 02:06
    VLAI
    Summary
    Certain NetModule devices allow credentials via GET parameters to CLI-PHP. These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T02:06:40.940Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.netmodule.com"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://seclists.org/fulldisclosure/2021/Aug/22"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Certain NetModule devices allow credentials via GET parameters to CLI-PHP. These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-23T04:37:50.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.netmodule.com"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://seclists.org/fulldisclosure/2021/Aug/22"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-39291",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Certain NetModule devices allow credentials via GET parameters to CLI-PHP. These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.netmodule.com",
                  "refsource": "MISC",
                  "url": "https://www.netmodule.com"
                },
                {
                  "name": "https://seclists.org/fulldisclosure/2021/Aug/22",
                  "refsource": "MISC",
                  "url": "https://seclists.org/fulldisclosure/2021/Aug/22"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-39291",
        "datePublished": "2021-08-23T04:37:50.000Z",
        "dateReserved": "2021-08-18T00:00:00.000Z",
        "dateUpdated": "2024-08-04T02:06:40.940Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-39290 (GCVE-0-2021-39290)

    Vulnerability from nvd – Published: 2021-08-23 04:35 – Updated: 2024-08-04 02:06
    VLAI
    Summary
    Certain NetModule devices allow Limited Session Fixation via PHPSESSID. These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T02:06:41.375Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.netmodule.com"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://seclists.org/fulldisclosure/2021/Aug/22"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Certain NetModule devices allow Limited Session Fixation via PHPSESSID. These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-23T04:35:45.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.netmodule.com"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://seclists.org/fulldisclosure/2021/Aug/22"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-39290",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Certain NetModule devices allow Limited Session Fixation via PHPSESSID. These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.netmodule.com",
                  "refsource": "MISC",
                  "url": "https://www.netmodule.com"
                },
                {
                  "name": "https://seclists.org/fulldisclosure/2021/Aug/22",
                  "refsource": "MISC",
                  "url": "https://seclists.org/fulldisclosure/2021/Aug/22"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-39290",
        "datePublished": "2021-08-23T04:35:45.000Z",
        "dateReserved": "2021-08-18T00:00:00.000Z",
        "dateUpdated": "2024-08-04T02:06:41.375Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-39289 (GCVE-0-2021-39289)

    Vulnerability from nvd – Published: 2021-08-23 04:33 – Updated: 2024-08-04 02:06
    VLAI
    Summary
    Certain NetModule devices have Insecure Password Handling (cleartext or reversible encryption), These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    https://www.netmodule.com x_refsource_MISC
    http://seclists.org/fulldisclosure/2021/Aug/22 x_refsource_CONFIRM
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T02:06:41.380Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.netmodule.com"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2021/Aug/22"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Certain NetModule devices have Insecure Password Handling (cleartext or reversible encryption), These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-23T04:33:03.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.netmodule.com"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://seclists.org/fulldisclosure/2021/Aug/22"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-39289",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Certain NetModule devices have Insecure Password Handling (cleartext or reversible encryption), These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.netmodule.com",
                  "refsource": "MISC",
                  "url": "https://www.netmodule.com"
                },
                {
                  "name": "http://seclists.org/fulldisclosure/2021/Aug/22",
                  "refsource": "CONFIRM",
                  "url": "http://seclists.org/fulldisclosure/2021/Aug/22"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-39289",
        "datePublished": "2021-08-23T04:33:03.000Z",
        "dateReserved": "2021-08-18T00:00:00.000Z",
        "dateUpdated": "2024-08-04T02:06:41.380Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46306 (GCVE-0-2023-46306)

    Vulnerability from cvelistv5 – Published: 2023-10-22 00:00 – Updated: 2024-09-12 18:22
    VLAI
    Summary
    The web administration interface in NetModule Router Software (NRSW) 4.6 before 4.6.0.106 and 4.8 before 4.8.0.101 executes an OS command constructed with unsanitized user input: shell metacharacters in the /admin/gnssAutoAlign.php device_id parameter. This occurs because another thread can be started before the trap that triggers the cleanup function. A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges. NOTE: this is different from CVE-2023-0861 and CVE-2023-0862, which were fixed in version 4.6.0.105.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    netmodule netmodule_router_software Affected: 4.6.0.0 , < 4.6.0.106 (custom)
        cpe:2.3:a:netmodule:netmodule_router_software:4.6.0.0:*:*:*:*:*:*:*
    Create a notification for this product.
    netmodule netmodule_router_software Affected: 4.8 , < 4.8.0.101 (custom)
        cpe:2.3:a:netmodule:netmodule_router_software:4.8:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:45:40.734Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://share.netmodule.com/public/system-software/4.8/4.8.0.101/NRSW-RN-4.8.0.101.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://share.netmodule.com/public/system-software/4.6/4.6.0.106/NRSW-RN-4.6.0.106.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://pentest.blog/advisory-netmodule-router-software-race-condition-leads-to-remote-code-execution/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:netmodule:netmodule_router_software:4.6.0.0:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "netmodule_router_software",
                "vendor": "netmodule",
                "versions": [
                  {
                    "lessThan": "4.6.0.106",
                    "status": "affected",
                    "version": "4.6.0.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:netmodule:netmodule_router_software:4.8:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "netmodule_router_software",
                "vendor": "netmodule",
                "versions": [
                  {
                    "lessThan": "4.8.0.101",
                    "status": "affected",
                    "version": "4.8",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46306",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-12T18:17:05.575956Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-12T18:22:55.873Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The web administration interface in NetModule Router Software (NRSW) 4.6 before 4.6.0.106 and 4.8 before 4.8.0.101 executes an OS command constructed with unsanitized user input: shell metacharacters in the /admin/gnssAutoAlign.php device_id parameter. This occurs because another thread can be started before the trap that triggers the cleanup function. A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges. NOTE: this is different from CVE-2023-0861 and CVE-2023-0862, which were fixed in version 4.6.0.105."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-22T20:07:16.731Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://share.netmodule.com/public/system-software/4.8/4.8.0.101/NRSW-RN-4.8.0.101.pdf"
            },
            {
              "url": "https://share.netmodule.com/public/system-software/4.6/4.6.0.106/NRSW-RN-4.6.0.106.pdf"
            },
            {
              "url": "https://pentest.blog/advisory-netmodule-router-software-race-condition-leads-to-remote-code-execution/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-46306",
        "datePublished": "2023-10-22T00:00:00.000Z",
        "dateReserved": "2023-10-22T00:00:00.000Z",
        "dateUpdated": "2024-09-12T18:22:55.873Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-0862 (GCVE-0-2023-0862)

    Vulnerability from cvelistv5 – Published: 2023-02-16 09:07 – Updated: 2025-03-18 14:50
    VLAI
    Title
    Path Traversal in NetModule NSRW
    Summary
    The NetModule NSRW web administration interface is vulnerable to path traversals, which could lead to arbitrary file uploads and deletion. By uploading malicious files to the web root directory, authenticated users could gain remote command execution with elevated privileges. This issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    Impacted products
    Vendor Product Version
    NetModule NSRW Affected: 4.3.0.0 , < 4.3.0.119 (4.3.0.119)
    Affected: 4.4.0.0 , < 4.4.0.118 (4.4.0.118)
    Affected: 4.6.0.0 , < 4.6.0.105 (4.6.0.105)
    Affected: 4.7.0.0 , < 4.7.0.103 (4.7.0.103)
    Create a notification for this product.
    Date Public
    2023-02-16 09:00
    Credits
    Quentin Kaiser from ONEKEY Research Labs
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:24:34.659Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://share.netmodule.com/public/system-software/4.7/4.7.0.103/NRSW-RN-4.7.0.103.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://onekey.com/blog/security-advisory-netmodule-multiple-vulnerabilities/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-0862",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-18T14:50:33.476944Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-18T14:50:42.840Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "web administration interface"
              ],
              "product": "NSRW",
              "vendor": "NetModule",
              "versions": [
                {
                  "lessThan": "4.3.0.119",
                  "status": "affected",
                  "version": "4.3.0.0",
                  "versionType": "4.3.0.119"
                },
                {
                  "lessThan": "4.4.0.118",
                  "status": "affected",
                  "version": "4.4.0.0",
                  "versionType": "4.4.0.118"
                },
                {
                  "lessThan": "4.6.0.105",
                  "status": "affected",
                  "version": "4.6.0.0",
                  "versionType": "4.6.0.105"
                },
                {
                  "lessThan": "4.7.0.103",
                  "status": "affected",
                  "version": "4.7.0.0",
                  "versionType": "4.7.0.103"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Quentin Kaiser from ONEKEY Research Labs"
            }
          ],
          "datePublic": "2023-02-16T09:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The NetModule NSRW web administration interface is vulnerable to path traversals, which could lead to arbitrary file uploads and deletion. By uploading malicious files to the web root directory, authenticated users could gain remote command execution with elevated privileges.\u003cbr\u003e\u003cbr\u003eThis issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.\u003cbr\u003e"
                }
              ],
              "value": "The NetModule NSRW web administration interface is vulnerable to path traversals, which could lead to arbitrary file uploads and deletion. By uploading malicious files to the web root directory, authenticated users could gain remote command execution with elevated privileges.\n\nThis issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-21T08:24:22.762Z",
            "orgId": "2d533b80-6e4a-4e20-93e2-171235122846",
            "shortName": "ONEKEY"
          },
          "references": [
            {
              "url": "https://share.netmodule.com/public/system-software/4.7/4.7.0.103/NRSW-RN-4.7.0.103.pdf"
            },
            {
              "url": "https://onekey.com/blog/security-advisory-netmodule-multiple-vulnerabilities/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Path Traversal in NetModule NSRW",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2d533b80-6e4a-4e20-93e2-171235122846",
        "assignerShortName": "ONEKEY",
        "cveId": "CVE-2023-0862",
        "datePublished": "2023-02-16T09:07:09.930Z",
        "dateReserved": "2023-02-16T09:01:36.192Z",
        "dateUpdated": "2025-03-18T14:50:42.840Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-0861 (GCVE-0-2023-0861)

    Vulnerability from cvelistv5 – Published: 2023-02-16 08:58 – Updated: 2025-03-18 14:54
    VLAI
    Title
    Authenticated Command Injection in NetModule NSRW
    Summary
    NetModule NSRW web administration interface executes an OS command constructed with unsanitized user input. A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges. This issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    NetModule NSRW Affected: 4.3.0.0 , < 4.3.0.119 (4.3.0.119)
    Affected: 4.4.0.0 , < 4.4.0.118 (4.4.0.118)
    Affected: 4.6.0.0 , < 4.6.0.105 (4.6.0.105)
    Affected: 4.7.0.0 , < 4.7.0.103 (4.7.0.103)
    Create a notification for this product.
    Date Public
    2023-02-16 09:00
    Credits
    Quentin Kaiser from ONEKEY Research Labs
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:24:34.694Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://share.netmodule.com/public/system-software/4.7/4.7.0.103/NRSW-RN-4.7.0.103.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://onekey.com/blog/security-advisory-netmodule-multiple-vulnerabilities"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-0861",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-18T14:54:45.830831Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-18T14:54:51.639Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "web administration interface"
              ],
              "platforms": [
                "Linux"
              ],
              "product": "NSRW",
              "vendor": "NetModule",
              "versions": [
                {
                  "lessThan": "4.3.0.119",
                  "status": "affected",
                  "version": "4.3.0.0",
                  "versionType": "4.3.0.119"
                },
                {
                  "lessThan": "4.4.0.118",
                  "status": "affected",
                  "version": "4.4.0.0",
                  "versionType": "4.4.0.118"
                },
                {
                  "lessThan": "4.6.0.105",
                  "status": "affected",
                  "version": "4.6.0.0",
                  "versionType": "4.6.0.105"
                },
                {
                  "lessThan": "4.7.0.103",
                  "status": "affected",
                  "version": "4.7.0.0",
                  "versionType": "4.7.0.103"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Quentin Kaiser from ONEKEY Research Labs"
            }
          ],
          "datePublic": "2023-02-16T09:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "NetModule NSRW web administration interface executes an OS command constructed with unsanitized user input.\u0026nbsp;A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges.\u003cbr\u003e\u003cp\u003eThis issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.\u003c/p\u003e"
                }
              ],
              "value": "NetModule NSRW web administration interface executes an OS command constructed with unsanitized user input.\u00a0A successful exploit could allow an authenticated user to execute arbitrary commands with elevated privileges.\nThis issue affects NSRW: from 4.3.0.0 before 4.3.0.119, from 4.4.0.0 before 4.4.0.118, from 4.6.0.0 before 4.6.0.105, from 4.7.0.0 before 4.7.0.103.\n\n"
            }
          ],
          "exploits": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Proof-of-concept."
                }
              ],
              "value": "Proof-of-concept."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-248",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-248 Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-21T08:24:45.882Z",
            "orgId": "2d533b80-6e4a-4e20-93e2-171235122846",
            "shortName": "ONEKEY"
          },
          "references": [
            {
              "url": "https://share.netmodule.com/public/system-software/4.7/4.7.0.103/NRSW-RN-4.7.0.103.pdf"
            },
            {
              "url": "https://onekey.com/blog/security-advisory-netmodule-multiple-vulnerabilities"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Authenticated Command Injection in NetModule NSRW",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2d533b80-6e4a-4e20-93e2-171235122846",
        "assignerShortName": "ONEKEY",
        "cveId": "CVE-2023-0861",
        "datePublished": "2023-02-16T08:58:43.370Z",
        "dateReserved": "2023-02-16T08:48:31.394Z",
        "dateUpdated": "2025-03-18T14:54:51.639Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-39291 (GCVE-0-2021-39291)

    Vulnerability from cvelistv5 – Published: 2021-08-23 04:37 – Updated: 2024-08-04 02:06
    VLAI
    Summary
    Certain NetModule devices allow credentials via GET parameters to CLI-PHP. These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T02:06:40.940Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.netmodule.com"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://seclists.org/fulldisclosure/2021/Aug/22"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Certain NetModule devices allow credentials via GET parameters to CLI-PHP. These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-23T04:37:50.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.netmodule.com"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://seclists.org/fulldisclosure/2021/Aug/22"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-39291",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Certain NetModule devices allow credentials via GET parameters to CLI-PHP. These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.netmodule.com",
                  "refsource": "MISC",
                  "url": "https://www.netmodule.com"
                },
                {
                  "name": "https://seclists.org/fulldisclosure/2021/Aug/22",
                  "refsource": "MISC",
                  "url": "https://seclists.org/fulldisclosure/2021/Aug/22"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-39291",
        "datePublished": "2021-08-23T04:37:50.000Z",
        "dateReserved": "2021-08-18T00:00:00.000Z",
        "dateUpdated": "2024-08-04T02:06:40.940Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-39290 (GCVE-0-2021-39290)

    Vulnerability from cvelistv5 – Published: 2021-08-23 04:35 – Updated: 2024-08-04 02:06
    VLAI
    Summary
    Certain NetModule devices allow Limited Session Fixation via PHPSESSID. These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T02:06:41.375Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.netmodule.com"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://seclists.org/fulldisclosure/2021/Aug/22"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Certain NetModule devices allow Limited Session Fixation via PHPSESSID. These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-23T04:35:45.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.netmodule.com"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://seclists.org/fulldisclosure/2021/Aug/22"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-39290",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Certain NetModule devices allow Limited Session Fixation via PHPSESSID. These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.netmodule.com",
                  "refsource": "MISC",
                  "url": "https://www.netmodule.com"
                },
                {
                  "name": "https://seclists.org/fulldisclosure/2021/Aug/22",
                  "refsource": "MISC",
                  "url": "https://seclists.org/fulldisclosure/2021/Aug/22"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-39290",
        "datePublished": "2021-08-23T04:35:45.000Z",
        "dateReserved": "2021-08-18T00:00:00.000Z",
        "dateUpdated": "2024-08-04T02:06:41.375Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-39289 (GCVE-0-2021-39289)

    Vulnerability from cvelistv5 – Published: 2021-08-23 04:33 – Updated: 2024-08-04 02:06
    VLAI
    Summary
    Certain NetModule devices have Insecure Password Handling (cleartext or reversible encryption), These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    https://www.netmodule.com x_refsource_MISC
    http://seclists.org/fulldisclosure/2021/Aug/22 x_refsource_CONFIRM
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T02:06:41.380Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.netmodule.com"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2021/Aug/22"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Certain NetModule devices have Insecure Password Handling (cleartext or reversible encryption), These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-23T04:33:03.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.netmodule.com"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://seclists.org/fulldisclosure/2021/Aug/22"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-39289",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Certain NetModule devices have Insecure Password Handling (cleartext or reversible encryption), These models with firmware before 4.3.0.113, 4.4.0.111, and 4.5.0.105 are affected: NB800, NB1600, NB1601, NB1800, NB1810, NB2700, NB2710, NB2800, NB2810, NB3700, NB3701, NB3710, NB3711, NB3720, and NB3800."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.netmodule.com",
                  "refsource": "MISC",
                  "url": "https://www.netmodule.com"
                },
                {
                  "name": "http://seclists.org/fulldisclosure/2021/Aug/22",
                  "refsource": "CONFIRM",
                  "url": "http://seclists.org/fulldisclosure/2021/Aug/22"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-39289",
        "datePublished": "2021-08-23T04:33:03.000Z",
        "dateReserved": "2021-08-18T00:00:00.000Z",
        "dateUpdated": "2024-08-04T02:06:41.380Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }