GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration
Common Weakness Enumeration

CWE-312

Allowed

Cleartext Storage of Sensitive Information

Abstraction: Base · Status: Draft

The product stores sensitive information in cleartext within a resource that might be accessible to another control sphere.

1100 vulnerabilities reference this CWE, most recent first.

CVE-2021-38422 (GCVE-0-2021-38422)

Vulnerability from cvelistv5 – Published: 2021-11-03 19:05 – Updated: 2024-09-16 17:47
VLAI
Title
Delta Electronics DIALink
Summary
Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
References
Impacted products
Vendor Product Version
Delta Electronics DIALink Affected: All , ≤ 1.2.4.0 (custom)
Create a notification for this product.
Date Public
2021-10-21 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.224Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DIALink",
          "vendor": "Delta Electronics",
          "versions": [
            {
              "lessThanOrEqual": "1.2.4.0",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2021-10-21T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-03T19:05:10.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
        }
      ],
      "source": {
        "advisory": "ICSA-21-294-02",
        "discovery": "UNKNOWN"
      },
      "title": "Delta Electronics DIALink",
      "workarounds": [
        {
          "lang": "en",
          "value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2021-10-21T18:29:00.000Z",
          "ID": "CVE-2021-38422",
          "STATE": "PUBLIC",
          "TITLE": "Delta Electronics DIALink"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DIALink",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "1.2.4.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Delta Electronics"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Michael Heinzl reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attacker to have extensive access to the application directory and escalate privileges."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312 Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-294-02"
            }
          ]
        },
        "source": {
          "advisory": "ICSA-21-294-02",
          "discovery": "UNKNOWN"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Delta Electronics is aware of the vulnerabilities and is currently working on an update."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38422",
    "datePublished": "2021-11-03T19:05:10.286Z",
    "dateReserved": "2021-08-10T00:00:00.000Z",
    "dateUpdated": "2024-09-16T17:47:43.779Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36782 (GCVE-0-2021-36782)

Vulnerability from cvelistv5 – Published: 2022-09-07 08:20 – Updated: 2024-09-17 04:14
VLAI
Title
Rancher: Plaintext storage and exposure of credentials in Rancher API and cluster.management.cattle.io object
Summary
A Cleartext Storage of Sensitive Information vulnerability in SUSE Rancher allows authenticated Cluster Owners, Cluster Members, Project Owners, Project Members and User Base to use the Kubernetes API to retrieve plaintext version of sensitive data. This issue affects: SUSE Rancher Rancher versions prior to 2.5.16; Rancher versions prior to 2.6.7.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
References
Impacted products
Vendor Product Version
SUSE Rancher Affected: Rancher , < 2.5.16 (custom)
Create a notification for this product.
SUSE Rancher Affected: Rancher , < 2.6.7 (custom)
Create a notification for this product.
Date Public
2022-08-19 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:01:59.069Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.suse.com/show_bug.cgi?id=1193988"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/rancher/rancher/security/advisories/GHSA-g7j7-h4q8-8w2f"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rancher",
          "vendor": "SUSE",
          "versions": [
            {
              "lessThan": "2.5.16",
              "status": "affected",
              "version": "Rancher",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Rancher",
          "vendor": "SUSE",
          "versions": [
            {
              "lessThan": "2.6.7",
              "status": "affected",
              "version": "Rancher",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Florian Struck (from Continum AG) and Marco Stuurman (from Shock Media B.V.)"
        }
      ],
      "datePublic": "2022-08-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Cleartext Storage of Sensitive Information vulnerability in SUSE Rancher allows authenticated Cluster Owners, Cluster Members, Project Owners, Project Members and User Base to use the Kubernetes API to retrieve plaintext version of sensitive data. This issue affects: SUSE Rancher Rancher versions prior to 2.5.16; Rancher versions prior to 2.6.7."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-07T08:20:15.000Z",
        "orgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
        "shortName": "suse"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.suse.com/show_bug.cgi?id=1193988"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/rancher/rancher/security/advisories/GHSA-g7j7-h4q8-8w2f"
        }
      ],
      "source": {
        "advisory": "https://bugzilla.suse.com/show_bug.cgi?id=1193988",
        "defect": [
          "1193988"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Rancher: Plaintext storage and exposure of credentials in Rancher API and cluster.management.cattle.io object",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@suse.com",
          "DATE_PUBLIC": "2022-08-19T00:00:00.000Z",
          "ID": "CVE-2021-36782",
          "STATE": "PUBLIC",
          "TITLE": "Rancher: Plaintext storage and exposure of credentials in Rancher API and cluster.management.cattle.io object"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rancher",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Rancher",
                            "version_value": "2.5.16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Rancher",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Rancher",
                            "version_value": "2.6.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "SUSE"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Florian Struck (from Continum AG) and Marco Stuurman (from Shock Media B.V.)"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Cleartext Storage of Sensitive Information vulnerability in SUSE Rancher allows authenticated Cluster Owners, Cluster Members, Project Owners, Project Members and User Base to use the Kubernetes API to retrieve plaintext version of sensitive data. This issue affects: SUSE Rancher Rancher versions prior to 2.5.16; Rancher versions prior to 2.6.7."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312: Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.suse.com/show_bug.cgi?id=1193988",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.suse.com/show_bug.cgi?id=1193988"
            },
            {
              "name": "https://github.com/rancher/rancher/security/advisories/GHSA-g7j7-h4q8-8w2f",
              "refsource": "CONFIRM",
              "url": "https://github.com/rancher/rancher/security/advisories/GHSA-g7j7-h4q8-8w2f"
            }
          ]
        },
        "source": {
          "advisory": "https://bugzilla.suse.com/show_bug.cgi?id=1193988",
          "defect": [
            "1193988"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
    "assignerShortName": "suse",
    "cveId": "CVE-2021-36782",
    "datePublished": "2022-09-07T08:20:16.064Z",
    "dateReserved": "2021-07-19T00:00:00.000Z",
    "dateUpdated": "2024-09-17T04:14:05.504Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-35526 (GCVE-0-2021-35526)

Vulnerability from cvelistv5 – Published: 2021-09-08 15:10 – Updated: 2024-09-16 19:30
VLAI
Title
Storage of Sensitive Information Vulnerability in Hitachi ABB Power Grids System Data Manager – SDM600 Product
Summary
Backup file without encryption vulnerability is found in Hitachi ABB Power Grids System Data Manager – SDM600 allows attacker to gain access to sensitive information. This issue affects: Hitachi ABB Power Grids System Data Manager – SDM600 1.2 versions prior to FP2 HF6 (Build Nr. 1.2.14002.257).
CWE
  • cleartext storage
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
Date Public
2021-08-31 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:40:47.159Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?utm_campaign=\u0026utm_content=2021.08_5051_Cybersecurity%20Advisory%3A\u0026utm_medium=email\u0026utm_source=Eloqua\u0026DocumentID=9AKK107992A4700\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026elqTrackId=ba79ef3d8aec4a4fad6c0cbe06d33d6c\u0026elq=1bda419954724e908db108def16646a5\u0026elqaid=3638\u0026elqat=1\u0026elqCampaignId="
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-250-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "prior to Build Nr. 1.2.14002.257"
          ],
          "product": "System Data Manager \u2013 SDM600",
          "vendor": "Hitachi ABB Power Grids",
          "versions": [
            {
              "lessThan": "FP2 HF6",
              "status": "affected",
              "version": "1.2",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-08-31T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Backup file without encryption vulnerability is found in Hitachi ABB Power Grids System Data Manager \u2013 SDM600 allows attacker to gain access to sensitive information. This issue affects: Hitachi ABB Power Grids System Data Manager \u2013 SDM600 1.2 versions prior to FP2 HF6 (Build Nr. 1.2.14002.257)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "cleartext storage",
              "lang": "en",
              "type": "text"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-10-08T16:38:51.000Z",
        "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "shortName": "Hitachi Energy"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://search.abb.com/library/Download.aspx?utm_campaign=\u0026utm_content=2021.08_5051_Cybersecurity%20Advisory%3A\u0026utm_medium=email\u0026utm_source=Eloqua\u0026DocumentID=9AKK107992A4700\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026elqTrackId=ba79ef3d8aec4a4fad6c0cbe06d33d6c\u0026elq=1bda419954724e908db108def16646a5\u0026elqaid=3638\u0026elqat=1\u0026elqCampaignId="
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-250-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "The problem is remediated as of the following product version SDM600 version 1.2 FP2 HF6 (Build Nr. 1.2.14002.257). Hitachi ABB Power Grids recommends that customers apply the update at the earliest convenience. After successful upgrade it is recommended to move previously created vulnerable backups to secure place to avoid any nonauthorized access."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Storage of Sensitive Information Vulnerability in Hitachi ABB Power Grids System Data Manager \u2013 SDM600 Product",
      "workarounds": [
        {
          "lang": "en",
          "value": "It is recommended to implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources. Furthermore, recommended security practices as defined in SDM600 security deployment guideline and firewall configurations can help to protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.\n\nAdditional recommendation is to follow the hardening guidelines published by \u201cThe Center for Internet Security (CIS)\u201d https://www.cisecurity.org/about-us/ to protect the host Operating System."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@hitachi-powergrids.com",
          "DATE_PUBLIC": "2021-08-31T10:00:00.000Z",
          "ID": "CVE-2021-35526",
          "STATE": "PUBLIC",
          "TITLE": "Storage of Sensitive Information Vulnerability in Hitachi ABB Power Grids System Data Manager \u2013 SDM600 Product"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "System Data Manager \u2013 SDM600",
                      "version": {
                        "version_data": [
                          {
                            "platform": "prior to Build Nr. 1.2.14002.257",
                            "version_affected": "\u003c",
                            "version_name": "1.2",
                            "version_value": "FP2 HF6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hitachi ABB Power Grids"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Backup file without encryption vulnerability is found in Hitachi ABB Power Grids System Data Manager \u2013 SDM600 allows attacker to gain access to sensitive information. This issue affects: Hitachi ABB Power Grids System Data Manager \u2013 SDM600 1.2 versions prior to FP2 HF6 (Build Nr. 1.2.14002.257)."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "cleartext storage"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312 Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?utm_campaign=\u0026utm_content=2021.08_5051_Cybersecurity%20Advisory%3A\u0026utm_medium=email\u0026utm_source=Eloqua\u0026DocumentID=9AKK107992A4700\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026elqTrackId=ba79ef3d8aec4a4fad6c0cbe06d33d6c\u0026elq=1bda419954724e908db108def16646a5\u0026elqaid=3638\u0026elqat=1\u0026elqCampaignId=",
              "refsource": "CONFIRM",
              "url": "https://search.abb.com/library/Download.aspx?utm_campaign=\u0026utm_content=2021.08_5051_Cybersecurity%20Advisory%3A\u0026utm_medium=email\u0026utm_source=Eloqua\u0026DocumentID=9AKK107992A4700\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026elqTrackId=ba79ef3d8aec4a4fad6c0cbe06d33d6c\u0026elq=1bda419954724e908db108def16646a5\u0026elqaid=3638\u0026elqat=1\u0026elqCampaignId="
            },
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-250-02",
              "refsource": "CONFIRM",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-250-02"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "The problem is remediated as of the following product version SDM600 version 1.2 FP2 HF6 (Build Nr. 1.2.14002.257). Hitachi ABB Power Grids recommends that customers apply the update at the earliest convenience. After successful upgrade it is recommended to move previously created vulnerable backups to secure place to avoid any nonauthorized access."
          }
        ],
        "source": {
          "discovery": "INTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "It is recommended to implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources. Furthermore, recommended security practices as defined in SDM600 security deployment guideline and firewall configurations can help to protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.\n\nAdditional recommendation is to follow the hardening guidelines published by \u201cThe Center for Internet Security (CIS)\u201d https://www.cisecurity.org/about-us/ to protect the host Operating System."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
    "assignerShortName": "Hitachi Energy",
    "cveId": "CVE-2021-35526",
    "datePublished": "2021-09-08T15:10:08.403Z",
    "dateReserved": "2021-06-28T00:00:00.000Z",
    "dateUpdated": "2024-09-16T19:30:41.163Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-35036 (GCVE-0-2021-35036)

Vulnerability from cvelistv5 – Published: 2022-03-01 06:20 – Updated: 2024-08-04 00:33
VLAI
Summary
A cleartext storage of information vulnerability in the Zyxel VMG3625-T50B firmware version V5.50(ABTL.0)b2k could allow an authenticated attacker to obtain sensitive information from the configuration file.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
References
Impacted products
Vendor Product Version
Zyxel VMG3625-T50B firmware Affected: V5.50(ABTL.0)b2k
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:33:49.906Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.zyxel.com/global/en/support/security-advisories/zyxel-security-advisory-for-cleartext-storage-of-information-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VMG3625-T50B firmware",
          "vendor": "Zyxel",
          "versions": [
            {
              "status": "affected",
              "version": "V5.50(ABTL.0)b2k"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A cleartext storage of information vulnerability in the Zyxel VMG3625-T50B firmware version V5.50(ABTL.0)b2k could allow an authenticated attacker to obtain sensitive information from the configuration file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-27T13:19:55.000Z",
        "orgId": "96e50032-ad0d-4058-a115-4d2c13821f9f",
        "shortName": "Zyxel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.zyxel.com/global/en/support/security-advisories/zyxel-security-advisory-for-cleartext-storage-of-information-vulnerability"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@zyxel.com.tw",
          "ID": "CVE-2021-35036",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VMG3625-T50B firmware",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V5.50(ABTL.0)b2k"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Zyxel"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A cleartext storage of information vulnerability in the Zyxel VMG3625-T50B firmware version V5.50(ABTL.0)b2k could allow an authenticated attacker to obtain sensitive information from the configuration file."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": "6.5",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312: Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zyxel.com/global/en/support/security-advisories/zyxel-security-advisory-for-cleartext-storage-of-information-vulnerability",
              "refsource": "CONFIRM",
              "url": "https://www.zyxel.com/global/en/support/security-advisories/zyxel-security-advisory-for-cleartext-storage-of-information-vulnerability"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "96e50032-ad0d-4058-a115-4d2c13821f9f",
    "assignerShortName": "Zyxel",
    "cveId": "CVE-2021-35036",
    "datePublished": "2022-03-01T06:20:12.000Z",
    "dateReserved": "2021-06-17T00:00:00.000Z",
    "dateUpdated": "2024-08-04T00:33:49.906Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-35035 (GCVE-0-2021-35035)

Vulnerability from cvelistv5 – Published: 2021-12-29 12:45 – Updated: 2024-08-04 00:33
VLAI
Summary
A cleartext storage of sensitive information vulnerability in the Zyxel NBG6604 firmware could allow a remote, authenticated attacker to obtain sensitive information from the configuration file.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
References
Impacted products
Vendor Product Version
Zyxel NBG6604 series firmware Affected: 1.00(ABIR.8)C0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:33:49.910Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.zyxel.com/support/Zyxel_security_advisory_for_sensitive_information_vulnerabilities_of_NBG6604_home_router.shtml"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NBG6604 series firmware",
          "vendor": "Zyxel",
          "versions": [
            {
              "status": "affected",
              "version": "1.00(ABIR.8)C0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A cleartext storage of sensitive information vulnerability in the Zyxel NBG6604 firmware could allow a remote, authenticated attacker to obtain sensitive information from the configuration file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-29T12:45:38.000Z",
        "orgId": "96e50032-ad0d-4058-a115-4d2c13821f9f",
        "shortName": "Zyxel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.zyxel.com/support/Zyxel_security_advisory_for_sensitive_information_vulnerabilities_of_NBG6604_home_router.shtml"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@zyxel.com.tw",
          "ID": "CVE-2021-35035",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NBG6604 series firmware",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.00(ABIR.8)C0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Zyxel"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A cleartext storage of sensitive information vulnerability in the Zyxel NBG6604 firmware could allow a remote, authenticated attacker to obtain sensitive information from the configuration file."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": "4.9",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312: Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zyxel.com/support/Zyxel_security_advisory_for_sensitive_information_vulnerabilities_of_NBG6604_home_router.shtml",
              "refsource": "CONFIRM",
              "url": "https://www.zyxel.com/support/Zyxel_security_advisory_for_sensitive_information_vulnerabilities_of_NBG6604_home_router.shtml"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "96e50032-ad0d-4058-a115-4d2c13821f9f",
    "assignerShortName": "Zyxel",
    "cveId": "CVE-2021-35035",
    "datePublished": "2021-12-29T12:45:38.000Z",
    "dateReserved": "2021-06-17T00:00:00.000Z",
    "dateUpdated": "2024-08-04T00:33:49.910Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-33716 (GCVE-0-2021-33716)

Vulnerability from cvelistv5 – Published: 2021-09-14 10:47 – Updated: 2024-08-03 23:58
VLAI
Summary
A vulnerability has been identified in SIMATIC CP 1543-1 (incl. SIPLUS variants) (All versions < V3.0), SIMATIC CP 1545-1 (All versions < V1.1). An attacker with access to the subnet of the affected device could retrieve sensitive information stored in cleartext.
Severity
No CVSS data available.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:58:22.881Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-535997.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "product": "SIMATIC CP 1545-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1543-1 (incl. SIPLUS variants) (All versions \u003c V3.0), SIMATIC CP 1545-1 (All versions \u003c V1.1). An attacker with access to the subnet of the affected device could retrieve sensitive information stored in cleartext."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-14T09:21:22.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-535997.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-33716",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC CP 1545-1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V1.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC CP 1543-1 (incl. SIPLUS variants) (All versions \u003c V3.0), SIMATIC CP 1545-1 (All versions \u003c V1.1). An attacker with access to the subnet of the affected device could retrieve sensitive information stored in cleartext."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312: Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-535997.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-535997.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-33716",
    "datePublished": "2021-09-14T10:47:34.000Z",
    "dateReserved": "2021-05-28T00:00:00.000Z",
    "dateUpdated": "2024-08-03T23:58:22.881Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-29481 (GCVE-0-2021-29481)

Vulnerability from cvelistv5 – Published: 2021-06-29 18:20 – Updated: 2024-08-03 22:11
VLAI
Title
Client side sessions should not allow unencrypted storage
Summary
Ratpack is a toolkit for creating web applications. In versions prior to 1.9.0, the default configuration of client side sessions results in unencrypted, but signed, data being set as cookie values. This means that if something sensitive goes into the session, it could be read by something with access to the cookies. For this to be a vulnerability, some kind of sensitive data would need to be stored in the session and the session cookie would have to leak. For example, the cookies are not configured with httpOnly and an adjacent XSS vulnerability within the site allowed capture of the cookies. As of version 1.9.0, a securely randomly generated signing key is used. As a workaround, one may supply an encryption key, as per the documentation recommendation.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
References
Impacted products
Vendor Product Version
ratpack ratpack Affected: < 1.9.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:11:05.773Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/ratpack/ratpack/security/advisories/GHSA-phj8-4cq3-794g"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ratpack/ratpack/pull/1590"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ratpack",
          "vendor": "ratpack",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 1.9.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Ratpack is a toolkit for creating web applications. In versions prior to 1.9.0, the default configuration of client side sessions results in unencrypted, but signed, data being set as cookie values. This means that if something sensitive goes into the session, it could be read by something with access to the cookies. For this to be a vulnerability, some kind of sensitive data would need to be stored in the session and the session cookie would have to leak. For example, the cookies are not configured with httpOnly and an adjacent XSS vulnerability within the site allowed capture of the cookies. As of version 1.9.0, a securely randomly generated signing key is used. As a workaround, one may supply an encryption key, as per the documentation recommendation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-29T18:20:12.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/ratpack/ratpack/security/advisories/GHSA-phj8-4cq3-794g"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ratpack/ratpack/pull/1590"
        }
      ],
      "source": {
        "advisory": "GHSA-phj8-4cq3-794g",
        "discovery": "UNKNOWN"
      },
      "title": "Client side sessions should not allow unencrypted storage",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2021-29481",
          "STATE": "PUBLIC",
          "TITLE": "Client side sessions should not allow unencrypted storage"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ratpack",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c 1.9.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ratpack"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Ratpack is a toolkit for creating web applications. In versions prior to 1.9.0, the default configuration of client side sessions results in unencrypted, but signed, data being set as cookie values. This means that if something sensitive goes into the session, it could be read by something with access to the cookies. For this to be a vulnerability, some kind of sensitive data would need to be stored in the session and the session cookie would have to leak. For example, the cookies are not configured with httpOnly and an adjacent XSS vulnerability within the site allowed capture of the cookies. As of version 1.9.0, a securely randomly generated signing key is used. As a workaround, one may supply an encryption key, as per the documentation recommendation."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312: Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ratpack/ratpack/security/advisories/GHSA-phj8-4cq3-794g",
              "refsource": "CONFIRM",
              "url": "https://github.com/ratpack/ratpack/security/advisories/GHSA-phj8-4cq3-794g"
            },
            {
              "name": "https://github.com/ratpack/ratpack/pull/1590",
              "refsource": "MISC",
              "url": "https://github.com/ratpack/ratpack/pull/1590"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-phj8-4cq3-794g",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2021-29481",
    "datePublished": "2021-06-29T18:20:12.000Z",
    "dateReserved": "2021-03-30T00:00:00.000Z",
    "dateUpdated": "2024-08-03T22:11:05.773Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27487 (GCVE-0-2021-27487)

Vulnerability from cvelistv5 – Published: 2021-06-16 11:59 – Updated: 2024-08-03 21:26
VLAI
Summary
ZOLL Defibrillator Dashboard, v prior to 2.2, The affected products contain credentials stored in plaintext. This could allow an attacker to gain access to sensitive information.
Severity
No CVSS data available.
CWE
  • CWE-312 - CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312
References
Impacted products
Vendor Product Version
n/a ZOLL Defibrillator Dashboard Affected: All versions prior to 2.2
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T21:26:08.954Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-161-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ZOLL Defibrillator Dashboard",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to 2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "ZOLL Defibrillator Dashboard, v prior to 2.2, The affected products contain credentials stored in plaintext. This could allow an attacker to gain access to sensitive information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-16T11:59:46.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-161-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-27487",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ZOLL Defibrillator Dashboard",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to 2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "ZOLL Defibrillator Dashboard, v prior to 2.2, The affected products contain credentials stored in plaintext. This could allow an attacker to gain access to sensitive information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsma-21-161-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-161-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-27487",
    "datePublished": "2021-06-16T11:59:46.000Z",
    "dateReserved": "2021-02-19T00:00:00.000Z",
    "dateUpdated": "2024-08-03T21:26:08.954Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-23878 (GCVE-0-2021-23878)

Vulnerability from cvelistv5 – Published: 2021-02-10 09:10 – Updated: 2024-09-16 19:41
VLAI
Title
Clear text storage of sensitive Information in ENS
Summary
Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine
CWE
  • CWE-312 - Cleartext storage of sensitive information
References
Impacted products
Vendor Product Version
McAfee LLC Endpoint Security (ENS) for Windows Affected: 10.7.x , < 10.7.0 February 2021 (custom)
Create a notification for this product.
Date Public
2021-02-10 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.386Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Endpoint Security (ENS) for Windows",
          "vendor": "McAfee LLC",
          "versions": [
            {
              "lessThan": "10.7.0 February 2021",
              "status": "affected",
              "version": "10.7.x",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Lockheed Martin Red Team"
        }
      ],
      "datePublic": "2021-02-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext storage of sensitive information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-10T09:10:14.000Z",
        "orgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
        "shortName": "trellix"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Clear text storage of sensitive Information in ENS",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@mcafee.com",
          "DATE_PUBLIC": "2021-02-10T00:00:00.000Z",
          "ID": "CVE-2021-23878",
          "STATE": "PUBLIC",
          "TITLE": "Clear text storage of sensitive Information in ENS"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Endpoint Security (ENS) for Windows",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "10.7.x",
                            "version_value": "10.7.0 February 2021"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "McAfee LLC"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Lockheed Martin Red Team"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Clear text storage of sensitive Information in memory vulnerability in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows a local user to view ENS settings and credentials via accessing process memory after the ENS administrator has performed specific actions. To exploit this, the local user has to access the relevant memory location immediately after an ENS administrator has made a configuration change through the console on their machine"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312: Cleartext storage of sensitive information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345",
              "refsource": "CONFIRM",
              "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
    "assignerShortName": "trellix",
    "cveId": "CVE-2021-23878",
    "datePublished": "2021-02-10T09:10:14.580Z",
    "dateReserved": "2021-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-16T19:41:11.060Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-22929 (GCVE-0-2021-22929)

Vulnerability from cvelistv5 – Published: 2021-08-31 16:53 – Updated: 2024-08-03 18:58
VLAI
Summary
An information disclosure exists in Brave Browser Desktop prior to version 1.28.62, where logged warning messages that included timestamps of connections to V2 onion domains in tor.log.
Severity
No CVSS data available.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information (CWE-312)
References
URL Tags
https://hackerone.com/reports/1249056 x_refsource_MISC
Impacted products
Vendor Product Version
n/a https://github.com/brave/brave-core Affected: 1.28.62
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:58:25.657Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://hackerone.com/reports/1249056"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "https://github.com/brave/brave-core",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "1.28.62"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An information disclosure exists in Brave Browser Desktop prior to version 1.28.62, where logged warning messages that included timestamps of connections to V2 onion domains in tor.log."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "Cleartext Storage of Sensitive Information (CWE-312)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-31T16:53:26.000Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://hackerone.com/reports/1249056"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "support@hackerone.com",
          "ID": "CVE-2021-22929",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "https://github.com/brave/brave-core",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.28.62"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An information disclosure exists in Brave Browser Desktop prior to version 1.28.62, where logged warning messages that included timestamps of connections to V2 onion domains in tor.log."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cleartext Storage of Sensitive Information (CWE-312)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://hackerone.com/reports/1249056",
              "refsource": "MISC",
              "url": "https://hackerone.com/reports/1249056"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2021-22929",
    "datePublished": "2021-08-31T16:53:26.000Z",
    "dateReserved": "2021-01-06T00:00:00.000Z",
    "dateUpdated": "2024-08-03T18:58:25.657Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Implementation System Configuration Operation

When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to encrypt the data at rest. [REF-1297] [REF-1299] [REF-1301]

Mitigation
Implementation System Configuration Operation

In some systems/environments such as cloud, the use of "double encryption" (at both the software and hardware layer) might be required, and the developer might be solely responsible for both layers, instead of shared responsibility with the administrator of the broader system/environment.

CAPEC-37: Retrieve Embedded Sensitive Data

An attacker examines a target system to find sensitive data that has been embedded within it. This information can reveal confidential contents, such as account numbers or individual keys/credentials that can be used as an intermediate step in a larger attack.