CWE-312
AllowedCleartext Storage of Sensitive Information
Abstraction: Base · Status: Draft
The product stores sensitive information in cleartext within a resource that might be accessible to another control sphere.
1100 vulnerabilities reference this CWE, most recent first.
CVE-2024-25023 (GCVE-0-2024-25023)
Vulnerability from cvelistv5 – Published: 2024-07-09 23:58 – Updated: 2024-09-21 09:52- CWE-312 - Cleartext Storage of Sensitive Information
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7159768 | vendor-advisory |
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entry |
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | QRadar Suite Software |
Affected:
1.10.12.0 , ≤ 1.10.22.0
(semver)
cpe:2.3:a:ibm:qradar_suite:1.10.12.0:*:*:*:*:*:*:* cpe:2.3:a:ibm:qradar_suite:1.10.22.0:*:*:*:*:*:*:* cpe:2.3:a:ibm:cloud_pak_for_security:1.10.0.0:*:*:*:*:*:*:* cpe:2.3:a:ibm:cloud_pak_for_security:1.10.11.0:*:*:*:*:*:*:* |
|
| IBM | Cloud Pak for Security |
Affected:
1.10.0.0 , ≤ 1.10.11.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25023",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-10T13:56:56.684468Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-11T16:32:55.525Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:36:21.530Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.ibm.com/support/pages/node/7159768"
},
{
"tags": [
"vdb-entry",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/281429"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:ibm:qradar_suite:1.10.12.0:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:qradar_suite:1.10.22.0:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:cloud_pak_for_security:1.10.0.0:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:cloud_pak_for_security:1.10.11.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "QRadar Suite Software",
"vendor": "IBM",
"versions": [
{
"lessThanOrEqual": "1.10.22.0",
"status": "affected",
"version": "1.10.12.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Cloud Pak for Security",
"vendor": "IBM",
"versions": [
{
"lessThanOrEqual": "1.10.11.0",
"status": "affected",
"version": "1.10.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "IBM Cloud Pak for Security 1.10.0.0 through 1.10.11.0 and IBM QRadar Suite Software 1.10.12.0 through 1.10.22.0 stores potentially sensitive information in log files that could be read by a local user. IBM X-Force ID: 281429."
}
],
"value": "IBM Cloud Pak for Security 1.10.0.0 through 1.10.11.0 and IBM QRadar Suite Software 1.10.12.0 through 1.10.22.0 stores potentially sensitive information in log files that could be read by a local user. IBM X-Force ID: 281429."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-21T09:52:56.459Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ibm.com/support/pages/node/7159768"
},
{
"tags": [
"vdb-entry"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/281429"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM QRadar Suite Software information disclosure",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2024-25023",
"datePublished": "2024-07-09T23:58:12.459Z",
"dateReserved": "2024-02-03T14:49:11.962Z",
"dateUpdated": "2024-09-21T09:52:56.459Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-23942 (GCVE-0-2024-23942)
Vulnerability from cvelistv5 – Published: 2025-03-18 11:03 – Updated: 2025-08-20 06:11- CWE-312 - Cleartext Storage of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbCONNECT24 |
Affected:
0 , < 2.16.2
(semver)
|
|
| MB connect line | mbNET |
Affected:
0 , < 8.2.0
(semver)
|
|
| MB connect line | mbNET.rokey |
Affected:
0 , < 8.2.0
(semver)
|
|
| MB connect line | mymbCONNECT24 |
Affected:
0 , < 2.16.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-23942",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-18T13:14:54.987012Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T13:15:06.774Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbCONNECT24",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.16.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "8.2.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET.rokey",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "8.2.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mymbCONNECT24",
"vendor": "MB connect line",
"versions": [
{
"lessThan": "2.16.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A local user may find a configuration file on the client workstation with unencrypted sensitive data. This allows an attacker to impersonate the device or prevent the device from accessing the cloud portal which leads to a DoS.\u003cbr\u003e"
}
],
"value": "A local user may find a configuration file on the client workstation with unencrypted sensitive data. This allows an attacker to impersonate the device or prevent the device from accessing the cloud portal which leads to a DoS."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-20T06:11:05.971Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-010"
}
],
"source": {
"advisory": "VDE-2024-010",
"defect": [
"CERT@VDE#64614"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line: Configuration File on the client workstation is not encrypted",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-23942",
"datePublished": "2025-03-18T11:03:35.116Z",
"dateReserved": "2024-01-24T08:35:23.199Z",
"dateUpdated": "2025-08-20T06:11:05.971Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-13843 (GCVE-0-2024-13843)
Vulnerability from cvelistv5 – Published: 2025-02-11 15:26 – Updated: 2025-02-11 16:00- CWE-312 - Cleartext Storage of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Ivanti | Connect Secure |
Unaffected:
22.7R2.6
(custom)
|
|
| Ivanti | Policy Secure |
Unaffected:
22.7R1.3
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-13843",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-11T16:00:38.375074Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T16:00:53.016Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "Connect Secure",
"vendor": "Ivanti",
"versions": [
{
"status": "unaffected",
"version": "22.7R2.6",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "Policy Secure",
"vendor": "Ivanti",
"versions": [
{
"status": "unaffected",
"version": "22.7R1.3",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCleartext storage of information in Ivanti Connect Secure before version 22.7R2.6 and Ivanti Policy Secure before version 22.7R1.3 allows a local authenticated attacker with admin privileges to read sensitive data.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
}
],
"value": "Cleartext storage of information in Ivanti Connect Secure before version 22.7R2.6 and Ivanti Policy Secure before version 22.7R1.3 allows a local authenticated attacker with admin privileges to read sensitive data."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37 Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T15:26:32.029Z",
"orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
"shortName": "ivanti"
},
"references": [
{
"url": "https://forums.ivanti.com/s/article/February-Security-Advisory-Ivanti-Connect-Secure-ICS-Ivanti-Policy-Secure-IPS-and-Ivanti-Secure-Access-Client-ISAC-Multiple-CVEs"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
"assignerShortName": "ivanti",
"cveId": "CVE-2024-13843",
"datePublished": "2025-02-11T15:26:32.029Z",
"dateReserved": "2025-02-06T17:13:09.182Z",
"dateUpdated": "2025-02-11T16:00:53.016Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-12094 (GCVE-0-2024-12094)
Vulnerability from cvelistv5 – Published: 2024-12-05 12:27 – Updated: 2025-04-15 09:16- CWE-312 - Cleartext Storage of Sensitive Information
| URL | Tags |
|---|---|
| https://www.cert-in.org.in/s2cMainServlet?pageid=… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Mogify Infotech | Tinxy Android app |
Affected:
<663000
|
|
| Mogify Infotech | Tinxy iOS app |
Affected:
<6.7.0
|
|
| mogify_infotech | tinxy_mobile_app |
Affected:
0 , < 663000
(custom)
cpe:2.3:a:mogify_infotech:tinxy_mobile_app:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mogify_infotech:tinxy_mobile_app:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "tinxy_mobile_app",
"vendor": "mogify_infotech",
"versions": [
{
"lessThan": "663000",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-12094",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-05T17:02:52.592390Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-05T17:08:43.062Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Tinxy Android app",
"vendor": "Mogify Infotech",
"versions": [
{
"status": "affected",
"version": "\u003c663000"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Tinxy iOS app",
"vendor": "Mogify Infotech",
"versions": [
{
"status": "affected",
"version": "\u003c6.7.0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported by Shravan Singh from Mumbai, India in Android app and Harshil Soni (Bitbreacher) in iOS app."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in the Tinxy mobile app due to storage of logged-in user information in plaintext on the device database. An attacker with physical access to the rooted device could exploit this vulnerability by accessing its database leading to unauthorized access of user information such as username, email address and mobile number.\u003cbr\u003eNote:\u003cbr\u003eTo exploit this vulnerability, the device must be rooted/jailbroken.\u003cbr\u003e"
}
],
"value": "This vulnerability exists in the Tinxy mobile app due to storage of logged-in user information in plaintext on the device database. An attacker with physical access to the rooted device could exploit this vulnerability by accessing its database leading to unauthorized access of user information such as username, email address and mobile number.\nNote:\nTo exploit this vulnerability, the device must be rooted/jailbroken."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37: Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "PHYSICAL",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312: Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T09:16:24.183Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2024-0355"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade Tinxy Andriod app to version 663000 and iOS app to version 6.7.0\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://play.google.com/store/apps/details?id=com.tinxy\"\u003ehttps://play.google.com/store/apps/details?id=com.tinxy\u003cbr\u003ehttps://apps.apple.com/in/app/tinxy/id1387370719\u003c/a\u003e\u003cbr\u003e"
}
],
"value": "Upgrade Tinxy Andriod app to version 663000 and iOS app to version 6.7.0\n https://play.google.com/store/apps/details?id=com.tinxy\nhttps://apps.apple.com/in/app/tinxy/id1387370719 https://play.google.com/store/apps/details"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Information Disclosure Vulnerability in Tinxy",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2024-12094",
"datePublished": "2024-12-05T12:27:41.540Z",
"dateReserved": "2024-12-03T11:39:35.089Z",
"dateUpdated": "2025-04-15T09:16:24.183Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-12079 (GCVE-0-2024-12079)
Vulnerability from cvelistv5 – Published: 2025-01-23 16:39 – Updated: 2025-02-12 17:12- CWE-312 - Cleartext Storage of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| ECOVACS | Unspecified robots |
Affected:
*
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-12079",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-23T16:54:04.223721Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T17:12:21.831Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Unspecified robots",
"vendor": "ECOVACS",
"versions": [
{
"status": "affected",
"version": "*"
}
]
}
],
"datePublic": "2023-12-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ECOVACS robot lawnmowers store the anti-theft PIN in cleartext on the device filesystem. An attacker can steal a lawnmower, read the PIN, and reset the anti-theft mechanism."
}
],
"metrics": [
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE"
}
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-23T16:39:06.903Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"name": "url",
"url": "https://dontvacuum.me/talks/37c3-2023/37c3-vacuuming-and-mowing.pdf"
}
],
"title": "ECOVACS lawnmowers cleartext storage of anti-theft PIN"
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2024-12079",
"datePublished": "2025-01-23T16:39:06.903Z",
"dateReserved": "2024-12-03T00:26:02.380Z",
"dateUpdated": "2025-02-12T17:12:21.831Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10523 (GCVE-0-2024-10523)
Vulnerability from cvelistv5 – Published: 2024-11-04 12:00 – Updated: 2024-11-04 15:06- CWE-312 - Cleartext Storage of Sensitive Information
| URL | Tags |
|---|---|
| https://www.cert-in.org.in/s2cMainServlet?pageid=… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link | TP-Link Tapo H100 IoT Smart Hub |
Affected:
<1.5.22
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10523",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-04T15:06:32.900301Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-04T15:06:40.613Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TP-Link Tapo H100 IoT Smart Hub",
"vendor": "TP-Link",
"versions": [
{
"status": "affected",
"version": "\u003c1.5.22"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported by Shravan Singh from Mumbai, India"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in TP-Link IoT Smart Hub due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the Wi-Fi credentials stored on the vulnerable device.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "This vulnerability exists in TP-Link IoT Smart Hub due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the Wi-Fi credentials stored on the vulnerable device."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37 Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "PHYSICAL",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:P/AC:H/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312: Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-04T12:00:05.802Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2024-0331"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade TP-Link Tapo H100 IoT Smart Hub to firmware version 1.5.22\u003cbr\u003e"
}
],
"value": "Upgrade TP-Link Tapo H100 IoT Smart Hub to firmware version 1.5.22"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Information Disclosure Vulnerability in TP-Link IoT Smart Hub",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2024-10523",
"datePublished": "2024-11-04T12:00:05.802Z",
"dateReserved": "2024-10-30T08:19:24.786Z",
"dateUpdated": "2024-11-04T15:06:40.613Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10404 (GCVE-0-2024-10404)
Vulnerability from cvelistv5 – Published: 2025-02-14 03:13 – Updated: 2025-02-14 15:46- CWE-312 - Cleartext Storage of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Brocade | Brocade SANnav |
Affected:
before 2.3.1b
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10404",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-14T15:36:40.906498Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-14T15:46:28.704Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "Brocade SANnav",
"vendor": "Brocade",
"versions": [
{
"status": "affected",
"version": "before 2.3.1b"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CalInvocationHandler in Brocade \nSANnav before 2.3.1b logs sensitive information in clear text. The \nvulnerability could allow an authenticated, local attacker to view \nBrocade Fabric OS switch sensitive information in clear text. An \nattacker with administrative privileges could retrieve sensitive \ninformation including passwords; SNMP responses that contain AuthSecret \nand PrivSecret after collecting a \u201csupportsave\u201d or getting access to an \nalready collected \u201csupportsave\u201d. NOTE: this issue exists because of an incomplete fix for CVE-2024-29952\n\n\u003cp\u003e\u003c/p\u003e"
}
],
"value": "CalInvocationHandler in Brocade \nSANnav before 2.3.1b logs sensitive information in clear text. The \nvulnerability could allow an authenticated, local attacker to view \nBrocade Fabric OS switch sensitive information in clear text. An \nattacker with administrative privileges could retrieve sensitive \ninformation including passwords; SNMP responses that contain AuthSecret \nand PrivSecret after collecting a \u201csupportsave\u201d or getting access to an \nalready collected \u201csupportsave\u201d. NOTE: this issue exists because of an incomplete fix for CVE-2024-29952"
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37 Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-14T03:13:19.662Z",
"orgId": "87b297d7-335e-4844-9551-11b97995a791",
"shortName": "brocade"
},
"references": [
{
"url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/25403"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Clear text password seen in switch-asset-collectors-mw in Brocade SANnav supportsave",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
"assignerShortName": "brocade",
"cveId": "CVE-2024-10404",
"datePublished": "2025-02-14T03:13:19.662Z",
"dateReserved": "2024-10-25T23:28:04.199Z",
"dateUpdated": "2025-02-14T15:46:28.704Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-9991 (GCVE-0-2024-9991)
Vulnerability from cvelistv5 – Published: 2024-10-25 12:27 – Updated: 2024-10-25 18:48- CWE-312 - Cleartext Storage of Sensitive Information
| URL | Tags |
|---|---|
| https://www.cert-in.org.in/s2cMainServlet?pageid=… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips Lighting (Signify Innovations India) | Philips Smart Wi-Fi LED Batten 24-Watt |
Affected:
<1.33.1
|
|
| Philips Lighting (Signify Innovations India) | Philips Smart Wi-Fi LED T Beamer 20-Watt |
Affected:
<1.33.1
|
|
| Philips Lighting (Signify Innovations India) | Philips Smart Bulb 9,10,12-Watt |
Affected:
<1.33.1
|
|
| Philips Lighting (Signify Innovations India) | Philips Smart T-Bulb 10,12-Watt |
Affected:
<1.33.1
|
|
| signify_innovations_india | phillips_smart_wi-fi_led_batten_24-watt_firmware |
Affected:
0 , < 1.33.1
(custom)
cpe:2.3:o:signify_innovations_india:phillips_smart_wi-fi_led_batten_24-watt_firmware:*:*:*:*:*:*:*:* |
|
| signify_innovations_india | phillips_smart_t-bulb_12-watt_firmware |
Affected:
0 , < 1.33.1
(custom)
cpe:2.3:o:signify_innovations_india:phillips_smart_t-bulb_12-watt_firmware:*:*:*:*:*:*:*:* |
|
| signify_innovations_india | phillips_smart_t-bulb_10-watt_firmware |
Affected:
0 , < 1.33.1
(custom)
cpe:2.3:o:signify_innovations_india:phillips_smart_t-bulb_10-watt_firmware:*:*:*:*:*:*:*:* |
|
| signify_innovations_india | phillips_smart_bulb_9-watt_firmware |
Affected:
0 , < 1.33.1
(custom)
cpe:2.3:o:signify_innovations_india:phillips_smart_bulb_9-watt_firmware:*:*:*:*:*:*:*:* |
|
| signify_innovations_india | phillips_smart_bulb_10-watt_firmware |
Affected:
0 , < 1.33.1
(custom)
cpe:2.3:o:signify_innovations_india:phillips_smart_bulb_10-watt_firmware:*:*:*:*:*:*:*:* |
|
| signify_innovations_india | phillips_smart_bulb_12-watt_firmware |
Affected:
0 , < 1.33.1
(custom)
cpe:2.3:o:signify_innovations_india:phillips_smart_bulb_12-watt_firmware:*:*:*:*:*:*:*:* |
|
| signify_innovations_india | phillips_smart_wi-fi_led_t_beamer_20-watt_firmware |
Affected:
0 , < 1.33.1
(custom)
cpe:2.3:o:signify_innovations_india:phillips_smart_wi-fi_led_t_beamer_20-watt_firmware:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:signify_innovations_india:phillips_smart_wi-fi_led_batten_24-watt_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "phillips_smart_wi-fi_led_batten_24-watt_firmware",
"vendor": "signify_innovations_india",
"versions": [
{
"lessThan": "1.33.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:signify_innovations_india:phillips_smart_t-bulb_12-watt_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "phillips_smart_t-bulb_12-watt_firmware",
"vendor": "signify_innovations_india",
"versions": [
{
"lessThan": "1.33.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:signify_innovations_india:phillips_smart_t-bulb_10-watt_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "phillips_smart_t-bulb_10-watt_firmware",
"vendor": "signify_innovations_india",
"versions": [
{
"lessThan": "1.33.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:signify_innovations_india:phillips_smart_bulb_9-watt_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "phillips_smart_bulb_9-watt_firmware",
"vendor": "signify_innovations_india",
"versions": [
{
"lessThan": "1.33.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:signify_innovations_india:phillips_smart_bulb_10-watt_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "phillips_smart_bulb_10-watt_firmware",
"vendor": "signify_innovations_india",
"versions": [
{
"lessThan": "1.33.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:signify_innovations_india:phillips_smart_bulb_12-watt_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "phillips_smart_bulb_12-watt_firmware",
"vendor": "signify_innovations_india",
"versions": [
{
"lessThan": "1.33.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:signify_innovations_india:phillips_smart_wi-fi_led_t_beamer_20-watt_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "phillips_smart_wi-fi_led_t_beamer_20-watt_firmware",
"vendor": "signify_innovations_india",
"versions": [
{
"lessThan": "1.33.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-9991",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-25T15:06:42.607006Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-25T18:48:23.746Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Philips Smart Wi-Fi LED Batten 24-Watt",
"vendor": "Philips Lighting (Signify Innovations India)",
"versions": [
{
"status": "affected",
"version": "\u003c1.33.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Philips Smart Wi-Fi LED T Beamer 20-Watt",
"vendor": "Philips Lighting (Signify Innovations India)",
"versions": [
{
"status": "affected",
"version": "\u003c1.33.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Philips Smart Bulb 9,10,12-Watt",
"vendor": "Philips Lighting (Signify Innovations India)",
"versions": [
{
"status": "affected",
"version": "\u003c1.33.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Philips Smart T-Bulb 10,12-Watt",
"vendor": "Philips Lighting (Signify Innovations India)",
"versions": [
{
"status": "affected",
"version": "\u003c1.33.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported by Shravan Singh, Amey Chavekar. Vishal Giri and Dr. Faruk Kazi from CoE- CNDS Lab, VJTI Mumbai, India"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in Philips lighting devices due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext Wi-Fi credentials stored on the vulnerable device.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow an attacker to gain unauthorized access to the Wi-Fi network to which vulnerable device is connected."
}
],
"value": "This vulnerability exists in Philips lighting devices due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext Wi-Fi credentials stored on the vulnerable device.\n\nSuccessful exploitation of this vulnerability could allow an attacker to gain unauthorized access to the Wi-Fi network to which vulnerable device is connected."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37 Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "PHYSICAL",
"baseScore": 7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312: Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-25T12:27:44.531Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2024-0329"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade Philips Smart Wi-Fi LED Batten 24-Watt, LED T Beamer 20-Watt, Smart Bulb 9,10,12-Watt and Smart T-Bulb 10,12-Watt to version 1.33.1\u003cbr\u003e"
}
],
"value": "Upgrade Philips Smart Wi-Fi LED Batten 24-Watt, LED T Beamer 20-Watt, Smart Bulb 9,10,12-Watt and Smart T-Bulb 10,12-Watt to version 1.33.1"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Cleartext Storage of Sensitive Information Vulnerability in Philips Lighting Devices",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2024-9991",
"datePublished": "2024-10-25T12:27:44.531Z",
"dateReserved": "2024-10-15T11:49:30.141Z",
"dateUpdated": "2024-10-25T18:48:23.746Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-9432 (GCVE-0-2024-9432)
Vulnerability from cvelistv5 – Published: 2026-01-30 18:31 – Updated: 2026-01-30 19:29- CWE-312 - Cleartext Storage of Sensitive Information
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-9432",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-30T19:29:45.564285Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-30T19:29:53.064Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Vertica",
"vendor": "OpenText\u2122",
"versions": [
{
"status": "affected",
"version": "23.x",
"versionType": "custom"
},
{
"status": "affected",
"version": "24.x"
},
{
"status": "affected",
"version": "25.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Davide Brian Di Campi, TIM Security Red Team Research"
},
{
"lang": "en",
"type": "finder",
"value": "Massimiliano Brolli, TIM Security Red Team Research"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cleartext Storage of Sensitive Information vulnerability in OpenText\u2122 Vertica allows Retrieve Embedded Sensitive Data.\u0026nbsp;\u0026nbsp;\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe vulnerability could read Vertica agent plaintext apikey.\u003c/span\u003e\u003cp\u003eThis issue affects Vertica versions: 23.X, 24.X, 25.X.\u0026nbsp;\u0026nbsp;\u003c/p\u003e"
}
],
"value": "Cleartext Storage of Sensitive Information vulnerability in OpenText\u2122 Vertica allows Retrieve Embedded Sensitive Data.\u00a0\u00a0\n\nThe vulnerability could read Vertica agent plaintext apikey.This issue affects Vertica versions: 23.X, 24.X, 25.X."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37 Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "GREEN",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:H/UI:N/VC:L/VI:N/VA:H/SC:L/SI:N/SA:H/AU:Y/R:U/RE:L/U:Green",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "LOW"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-30T18:31:31.448Z",
"orgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"shortName": "OpenText"
},
"references": [
{
"url": "https://portal.microfocus.com/s/article/KM000044937?language=en_US"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://portal.microfocus.com/s/article/KM000044937?language=en_US\"\u003ehttps://portal.microfocus.com/s/article/KM000044937?language=en_US\u003c/a\u003e\u003cbr\u003e"
}
],
"value": "https://portal.microfocus.com/s/article/KM000044937?language=en_US"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Cleartext Storage of Sensitive Information vulnerability has been discovered in OpenText\u2122 Vertica.",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f81092c5-7f14-476d-80dc-24857f90be84",
"assignerShortName": "OpenText",
"cveId": "CVE-2024-9432",
"datePublished": "2026-01-30T18:31:31.448Z",
"dateReserved": "2024-10-02T15:18:41.223Z",
"dateUpdated": "2026-01-30T19:29:53.064Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-8689 (GCVE-0-2024-8689)
Vulnerability from cvelistv5 – Published: 2024-09-11 16:42 – Updated: 2024-09-11 18:24- CWE-312 - Cleartext Storage of Sensitive Information
| Vendor | Product | Version | |
|---|---|---|---|
| Palo Alto Networks | ActiveMQ Content Pack |
Affected:
1.1.0 , < 1.1.15
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8689",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T18:23:33.866342Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T18:24:17.891Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ActiveMQ Content Pack",
"vendor": "Palo Alto Networks",
"versions": [
{
"changes": [
{
"at": "1.1.15",
"status": "unaffected"
}
],
"lessThan": "1.1.15",
"status": "affected",
"version": "1.1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Marcel Maeder of Swisscom (Schweiz) AG"
}
],
"datePublic": "2024-09-11T16:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A problem with the ActiveMQ integration for both Cortex XSOAR and Cortex XSIAM can result in the cleartext exposure of the configured ActiveMQ credentials in log bundles."
}
],
"value": "A problem with the ActiveMQ integration for both Cortex XSOAR and Cortex XSIAM can result in the cleartext exposure of the configured ActiveMQ credentials in log bundles."
}
],
"exploits": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Palo Alto Networks is not aware of any malicious exploitation of this issue.\u003cbr\u003e"
}
],
"value": "Palo Alto Networks is not aware of any malicious exploitation of this issue."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37 Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "AUTOMATIC",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "AMBER",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/AU:N/R:A/V:D/RE:M/U:Amber",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T16:42:16.113Z",
"orgId": "d6c1279f-00f6-4ef7-9217-f89ffe703ec0",
"shortName": "palo_alto"
},
"references": [
{
"url": "https://security.paloaltonetworks.com/CVE-2024-8689"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This issue is fixed in ActiveMQ Content Pack 1.1.15 and all later versions. You can download the content pack from \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cortex.marketplace.pan.dev/marketplace/details/ActiveMQ/\"\u003ehttps://cortex.marketplace.pan.dev/marketplace/details/ActiveMQ/\u003c/a\u003e.\u003cbr\u003e\u003cbr\u003eYou should use new ActiveMQ credentials for ActiveMQ integration only after you upgrade it to a fixed version. You should also revoke the previously existing credentials to prevent the misuse of exposed credentials.\u003cbr\u003e"
}
],
"value": "This issue is fixed in ActiveMQ Content Pack 1.1.15 and all later versions. You can download the content pack from https://cortex.marketplace.pan.dev/marketplace/details/ActiveMQ/ .\n\nYou should use new ActiveMQ credentials for ActiveMQ integration only after you upgrade it to a fixed version. You should also revoke the previously existing credentials to prevent the misuse of exposed credentials."
}
],
"source": {
"defect": [
"CRTX-105751"
],
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2024-09-11T16:00:00.000Z",
"value": "Initial publication"
}
],
"title": "ActiveMQ Content Pack: Cleartext Exposure of Credentials",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "d6c1279f-00f6-4ef7-9217-f89ffe703ec0",
"assignerShortName": "palo_alto",
"cveId": "CVE-2024-8689",
"datePublished": "2024-09-11T16:42:16.113Z",
"dateReserved": "2024-09-11T08:21:14.668Z",
"dateUpdated": "2024-09-11T18:24:17.891Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to encrypt the data at rest. [REF-1297] [REF-1299] [REF-1301]
Mitigation
In some systems/environments such as cloud, the use of "double encryption" (at both the software and hardware layer) might be required, and the developer might be solely responsible for both layers, instead of shared responsibility with the administrator of the broader system/environment.
CAPEC-37: Retrieve Embedded Sensitive Data
An attacker examines a target system to find sensitive data that has been embedded within it. This information can reveal confidential contents, such as account numbers or individual keys/credentials that can be used as an intermediate step in a larger attack.