Common Weakness Enumeration

CWE-269

Discouraged

Improper Privilege Management

Abstraction: Class · Status: Draft

The product does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.

5558 vulnerabilities reference this CWE, most recent first.

CVE-2017-20063 (GCVE-0-2017-20063)

Vulnerability from cvelistv5 – Published: 2022-06-20 04:50 – Updated: 2025-04-15 14:19
VLAI
Title
Elefant CMS File Upload drop privileges management
Summary
A vulnerability was found in Elefant CMS 1.3.12-RC. It has been classified as critical. Affected is an unknown function of the file /filemanager/upload/drop of the component File Upload. The manipulation leads to improper privilege management. It is possible to launch the attack remotely. Upgrading to version 1.3.13 is able to address this issue. It is recommended to upgrade the affected component.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
Elefant CMS Affected: 1.3.12-RC
Create a notification for this product.
Credits
Tim Coen
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T21:45:25.419Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2017/Feb/39"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.97260"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-20063",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T17:10:29.626891Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T14:19:12.837Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CMS",
          "vendor": "Elefant",
          "versions": [
            {
              "status": "affected",
              "version": "1.3.12-RC"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Tim Coen"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Elefant CMS 1.3.12-RC. It has been classified as critical. Affected is an unknown function of the file /filemanager/upload/drop of the component File Upload. The manipulation leads to improper privilege management. It is possible to launch the attack remotely. Upgrading to version 1.3.13 is able to address this issue. It is recommended to upgrade the affected component."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-20T04:50:34.000Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2017/Feb/39"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://vuldb.com/?id.97260"
        }
      ],
      "title": "Elefant CMS File Upload drop privileges management",
      "x_generator": "vuldb.com",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cna@vuldb.com",
          "ID": "CVE-2017-20063",
          "REQUESTER": "cna@vuldb.com",
          "STATE": "PUBLIC",
          "TITLE": "Elefant CMS File Upload drop privileges management"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CMS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.3.12-RC"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Elefant"
              }
            ]
          }
        },
        "credit": "Tim Coen",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was found in Elefant CMS 1.3.12-RC. It has been classified as critical. Affected is an unknown function of the file /filemanager/upload/drop of the component File Upload. The manipulation leads to improper privilege management. It is possible to launch the attack remotely. Upgrading to version 1.3.13 is able to address this issue. It is recommended to upgrade the affected component."
            }
          ]
        },
        "generator": "vuldb.com",
        "impact": {
          "cvss": {
            "baseScore": "6.3",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://seclists.org/fulldisclosure/2017/Feb/39",
              "refsource": "MISC",
              "url": "http://seclists.org/fulldisclosure/2017/Feb/39"
            },
            {
              "name": "https://vuldb.com/?id.97260",
              "refsource": "MISC",
              "url": "https://vuldb.com/?id.97260"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2017-20063",
    "datePublished": "2022-06-20T04:50:34.000Z",
    "dateReserved": "2022-06-18T00:00:00.000Z",
    "dateUpdated": "2025-04-15T14:19:12.837Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-20038 (GCVE-0-2017-20038)

Vulnerability from cvelistv5 – Published: 2022-06-11 10:00 – Updated: 2025-04-15 14:27
VLAI
Title
SICUNET Access Controller card_scan_decoder.php privileges management
Summary
A vulnerability was found in SICUNET Access Controller 0.32-05z and classified as critical. Affected by this issue is some unknown functionality of the file card_scan_decoder.php. The manipulation of the argument No/door leads to privilege escalation. The attack may be launched remotely.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
SICUNET Access Controller Affected: 0.32-05z
Create a notification for this product.
Credits
Andrew Griffiths
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T21:45:25.198Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2017/Mar/25"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.98906"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-20038",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T17:13:26.147370Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T14:27:05.409Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Controller",
          "vendor": "SICUNET",
          "versions": [
            {
              "status": "affected",
              "version": "0.32-05z"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Andrew Griffiths"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in SICUNET Access Controller 0.32-05z and classified as critical. Affected by this issue is some unknown functionality of the file card_scan_decoder.php. The manipulation of the argument No/door leads to privilege escalation. The attack may be launched remotely."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-11T10:00:23.000Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2017/Mar/25"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://vuldb.com/?id.98906"
        }
      ],
      "title": "SICUNET Access Controller card_scan_decoder.php privileges management",
      "x_generator": "vuldb.com",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cna@vuldb.com",
          "ID": "CVE-2017-20038",
          "REQUESTER": "cna@vuldb.com",
          "STATE": "PUBLIC",
          "TITLE": "SICUNET Access Controller card_scan_decoder.php privileges management"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "0.32-05z"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "SICUNET"
              }
            ]
          }
        },
        "credit": "Andrew Griffiths",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was found in SICUNET Access Controller 0.32-05z and classified as critical. Affected by this issue is some unknown functionality of the file card_scan_decoder.php. The manipulation of the argument No/door leads to privilege escalation. The attack may be launched remotely."
            }
          ]
        },
        "generator": "vuldb.com",
        "impact": {
          "cvss": {
            "baseScore": "6.3",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://seclists.org/fulldisclosure/2017/Mar/25",
              "refsource": "MISC",
              "url": "http://seclists.org/fulldisclosure/2017/Mar/25"
            },
            {
              "name": "https://vuldb.com/?id.98906",
              "refsource": "MISC",
              "url": "https://vuldb.com/?id.98906"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2017-20038",
    "datePublished": "2022-06-11T10:00:23.000Z",
    "dateReserved": "2022-06-05T00:00:00.000Z",
    "dateUpdated": "2025-04-15T14:27:05.409Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-20037 (GCVE-0-2017-20037)

Vulnerability from cvelistv5 – Published: 2022-06-11 10:00 – Updated: 2025-04-15 14:27
VLAI
Title
SICUNET Access Controller privileges management
Summary
A vulnerability has been found in SICUNET Access Controller 0.32-05z and classified as critical. Affected by this vulnerability is an unknown functionality. The manipulation of the argument c leads to privilege escalation. The attack can be launched remotely.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
SICUNET Access Controller Affected: 0.32-05z
Create a notification for this product.
Credits
Andrew Griffiths
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T21:45:24.596Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2017/Mar/25"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.98905"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-20037",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T17:13:29.159071Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T14:27:16.117Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Controller",
          "vendor": "SICUNET",
          "versions": [
            {
              "status": "affected",
              "version": "0.32-05z"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Andrew Griffiths"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in SICUNET Access Controller 0.32-05z and classified as critical. Affected by this vulnerability is an unknown functionality. The manipulation of the argument c leads to privilege escalation. The attack can be launched remotely."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-11T10:00:21.000Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2017/Mar/25"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://vuldb.com/?id.98905"
        }
      ],
      "title": "SICUNET Access Controller privileges management",
      "x_generator": "vuldb.com",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cna@vuldb.com",
          "ID": "CVE-2017-20037",
          "REQUESTER": "cna@vuldb.com",
          "STATE": "PUBLIC",
          "TITLE": "SICUNET Access Controller privileges management"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "0.32-05z"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "SICUNET"
              }
            ]
          }
        },
        "credit": "Andrew Griffiths",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been found in SICUNET Access Controller 0.32-05z and classified as critical. Affected by this vulnerability is an unknown functionality. The manipulation of the argument c leads to privilege escalation. The attack can be launched remotely."
            }
          ]
        },
        "generator": "vuldb.com",
        "impact": {
          "cvss": {
            "baseScore": "6.3",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://seclists.org/fulldisclosure/2017/Mar/25",
              "refsource": "MISC",
              "url": "http://seclists.org/fulldisclosure/2017/Mar/25"
            },
            {
              "name": "https://vuldb.com/?id.98905",
              "refsource": "MISC",
              "url": "https://vuldb.com/?id.98905"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2017-20037",
    "datePublished": "2022-06-11T10:00:21.000Z",
    "dateReserved": "2022-06-05T00:00:00.000Z",
    "dateUpdated": "2025-04-15T14:27:16.117Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-20028 (GCVE-0-2017-20028)

Vulnerability from cvelistv5 – Published: 2022-06-09 22:36 – Updated: 2025-04-15 14:28
VLAI
Title
HumHub privileges management
Summary
A vulnerability was found in HumHub 0.20.1/1.0.0-beta.3. It has been classified as critical. This affects an unknown part. The manipulation leads to privilege escalation. It is possible to initiate the attack remotely. Upgrading to version 1.0.0 is able to address this issue. It is recommended to upgrade the affected component.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
unspecified HumHub Affected: 0.20.1
Affected: 1.0.0-beta.3
Create a notification for this product.
Credits
Tim Coen
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T21:45:24.570Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2017/Mar/48"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.98925"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-20028",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T17:13:32.357442Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T14:28:51.461Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HumHub",
          "vendor": "unspecified",
          "versions": [
            {
              "status": "affected",
              "version": "0.20.1"
            },
            {
              "status": "affected",
              "version": "1.0.0-beta.3"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Tim Coen"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in HumHub 0.20.1/1.0.0-beta.3. It has been classified as critical. This affects an unknown part. The manipulation leads to privilege escalation. It is possible to initiate the attack remotely. Upgrading to version 1.0.0 is able to address this issue. It is recommended to upgrade the affected component."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-09T22:36:05.000Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2017/Mar/48"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://vuldb.com/?id.98925"
        }
      ],
      "title": "HumHub privileges management",
      "x_generator": "vuldb.com",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cna@vuldb.com",
          "ID": "CVE-2017-20028",
          "REQUESTER": "cna@vuldb.com",
          "STATE": "PUBLIC",
          "TITLE": "HumHub privileges management"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HumHub",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "0.20.1"
                          },
                          {
                            "version_value": "1.0.0-beta.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": ""
              }
            ]
          }
        },
        "credit": "Tim Coen",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was found in HumHub 0.20.1/1.0.0-beta.3. It has been classified as critical. This affects an unknown part. The manipulation leads to privilege escalation. It is possible to initiate the attack remotely. Upgrading to version 1.0.0 is able to address this issue. It is recommended to upgrade the affected component."
            }
          ]
        },
        "generator": "vuldb.com",
        "impact": {
          "cvss": {
            "baseScore": "5.6",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://seclists.org/fulldisclosure/2017/Mar/48",
              "refsource": "MISC",
              "url": "http://seclists.org/fulldisclosure/2017/Mar/48"
            },
            {
              "name": "https://vuldb.com/?id.98925",
              "refsource": "MISC",
              "url": "https://vuldb.com/?id.98925"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2017-20028",
    "datePublished": "2022-06-09T22:36:05.000Z",
    "dateReserved": "2022-06-05T00:00:00.000Z",
    "dateUpdated": "2025-04-15T14:28:51.461Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-20025 (GCVE-0-2017-20025)

Vulnerability from cvelistv5 – Published: 2022-06-09 22:36 – Updated: 2025-04-15 14:29
VLAI
Title
Solare Solar-Log Flash Memory privileges management
Summary
A vulnerability was found in Solare Solar-Log 2.8.4-56/3.5.2-85. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component Flash Memory. The manipulation leads to privilege escalation. The attack can be launched remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component.
SSVC
Exploitation: poc Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
Solare Solar-Log Affected: 2.8.4-56
Affected: 3.5.2-85
Create a notification for this product.
Credits
T. Weber
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T21:45:24.591Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2017/Mar/58"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.98935"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-20025",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T16:56:22.988042Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T14:29:19.711Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Solar-Log",
          "vendor": "Solare",
          "versions": [
            {
              "status": "affected",
              "version": "2.8.4-56"
            },
            {
              "status": "affected",
              "version": "3.5.2-85"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "T. Weber"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Solare Solar-Log 2.8.4-56/3.5.2-85. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component Flash Memory. The manipulation leads to privilege escalation. The attack can be launched remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-09T22:36:00.000Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2017/Mar/58"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://vuldb.com/?id.98935"
        }
      ],
      "title": "Solare Solar-Log Flash Memory privileges management",
      "x_generator": "vuldb.com",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cna@vuldb.com",
          "ID": "CVE-2017-20025",
          "REQUESTER": "cna@vuldb.com",
          "STATE": "PUBLIC",
          "TITLE": "Solare Solar-Log Flash Memory privileges management"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Solar-Log",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2.8.4-56"
                          },
                          {
                            "version_value": "3.5.2-85"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Solare"
              }
            ]
          }
        },
        "credit": "T. Weber",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was found in Solare Solar-Log 2.8.4-56/3.5.2-85. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component Flash Memory. The manipulation leads to privilege escalation. The attack can be launched remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component."
            }
          ]
        },
        "generator": "vuldb.com",
        "impact": {
          "cvss": {
            "baseScore": "7.3",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://seclists.org/fulldisclosure/2017/Mar/58",
              "refsource": "MISC",
              "url": "http://seclists.org/fulldisclosure/2017/Mar/58"
            },
            {
              "name": "https://vuldb.com/?id.98935",
              "refsource": "MISC",
              "url": "https://vuldb.com/?id.98935"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2017-20025",
    "datePublished": "2022-06-09T22:36:00.000Z",
    "dateReserved": "2022-06-05T00:00:00.000Z",
    "dateUpdated": "2025-04-15T14:29:19.711Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-20023 (GCVE-0-2017-20023)

Vulnerability from cvelistv5 – Published: 2022-06-09 22:35 – Updated: 2025-04-15 14:29
VLAI
Title
Solare Solar-Log Network Config privileges management
Summary
A vulnerability was found in Solare Solar-Log 2.8.4-56/3.5.2-85 and classified as critical. This issue affects some unknown processing of the component Network Config. The manipulation leads to privilege escalation. The attack may be initiated remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
Solare Solar-Log Affected: 2.8.4-56
Affected: 3.5.2-85
Create a notification for this product.
Credits
T. Weber
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T21:45:24.624Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2017/Mar/58"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.98933"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-20023",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T17:12:31.199508Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T14:29:43.295Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Solar-Log",
          "vendor": "Solare",
          "versions": [
            {
              "status": "affected",
              "version": "2.8.4-56"
            },
            {
              "status": "affected",
              "version": "3.5.2-85"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "T. Weber"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Solare Solar-Log 2.8.4-56/3.5.2-85 and classified as critical. This issue affects some unknown processing of the component Network Config. The manipulation leads to privilege escalation. The attack may be initiated remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-09T22:35:57.000Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2017/Mar/58"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://vuldb.com/?id.98933"
        }
      ],
      "title": "Solare Solar-Log Network Config privileges management",
      "x_generator": "vuldb.com",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cna@vuldb.com",
          "ID": "CVE-2017-20023",
          "REQUESTER": "cna@vuldb.com",
          "STATE": "PUBLIC",
          "TITLE": "Solare Solar-Log Network Config privileges management"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Solar-Log",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2.8.4-56"
                          },
                          {
                            "version_value": "3.5.2-85"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Solare"
              }
            ]
          }
        },
        "credit": "T. Weber",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was found in Solare Solar-Log 2.8.4-56/3.5.2-85 and classified as critical. This issue affects some unknown processing of the component Network Config. The manipulation leads to privilege escalation. The attack may be initiated remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component."
            }
          ]
        },
        "generator": "vuldb.com",
        "impact": {
          "cvss": {
            "baseScore": "6.3",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://seclists.org/fulldisclosure/2017/Mar/58",
              "refsource": "MISC",
              "url": "http://seclists.org/fulldisclosure/2017/Mar/58"
            },
            {
              "name": "https://vuldb.com/?id.98933",
              "refsource": "MISC",
              "url": "https://vuldb.com/?id.98933"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2017-20023",
    "datePublished": "2022-06-09T22:35:57.000Z",
    "dateReserved": "2022-06-05T00:00:00.000Z",
    "dateUpdated": "2025-04-15T14:29:43.295Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-20021 (GCVE-0-2017-20021)

Vulnerability from cvelistv5 – Published: 2022-06-09 22:35 – Updated: 2025-04-15 14:29
VLAI
Title
Solare Solar-Log File Upload privileges management
Summary
A vulnerability, which was classified as critical, was found in Solare Solar-Log 2.8.4-56/3.5.2-85. This affects an unknown part of the component File Upload. The manipulation leads to privilege escalation. It is possible to initiate the attack remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component.
SSVC
Exploitation: poc Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
Solare Solar-Log Affected: 2.8.4-56
Affected: 3.5.2-85
Create a notification for this product.
Credits
T. Weber
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T21:45:24.669Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2017/Mar/58"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.98931"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-20021",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T16:56:29.344061Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T14:29:58.849Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Solar-Log",
          "vendor": "Solare",
          "versions": [
            {
              "status": "affected",
              "version": "2.8.4-56"
            },
            {
              "status": "affected",
              "version": "3.5.2-85"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "T. Weber"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, was found in Solare Solar-Log 2.8.4-56/3.5.2-85. This affects an unknown part of the component File Upload. The manipulation leads to privilege escalation. It is possible to initiate the attack remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-09T22:35:54.000Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2017/Mar/58"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://vuldb.com/?id.98931"
        }
      ],
      "title": "Solare Solar-Log File Upload privileges management",
      "x_generator": "vuldb.com",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cna@vuldb.com",
          "ID": "CVE-2017-20021",
          "REQUESTER": "cna@vuldb.com",
          "STATE": "PUBLIC",
          "TITLE": "Solare Solar-Log File Upload privileges management"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Solar-Log",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2.8.4-56"
                          },
                          {
                            "version_value": "3.5.2-85"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Solare"
              }
            ]
          }
        },
        "credit": "T. Weber",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability, which was classified as critical, was found in Solare Solar-Log 2.8.4-56/3.5.2-85. This affects an unknown part of the component File Upload. The manipulation leads to privilege escalation. It is possible to initiate the attack remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component."
            }
          ]
        },
        "generator": "vuldb.com",
        "impact": {
          "cvss": {
            "baseScore": "6.5",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://seclists.org/fulldisclosure/2017/Mar/58",
              "refsource": "MISC",
              "url": "http://seclists.org/fulldisclosure/2017/Mar/58"
            },
            {
              "name": "https://vuldb.com/?id.98931",
              "refsource": "MISC",
              "url": "https://vuldb.com/?id.98931"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2017-20021",
    "datePublished": "2022-06-09T22:35:54.000Z",
    "dateReserved": "2022-06-05T00:00:00.000Z",
    "dateUpdated": "2025-04-15T14:29:58.849Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-12728 (GCVE-0-2017-12728)

Vulnerability from cvelistv5 – Published: 2017-10-04 07:00 – Updated: 2024-08-05 18:43
VLAI
Summary
An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the context of the current system services.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a SpiderControl SCADA Web Server Affected: SpiderControl SCADA Web Server
Date Public
2017-10-04 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T18:43:56.611Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01"
          },
          {
            "name": "100668",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100668"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SpiderControl SCADA Web Server",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "SpiderControl SCADA Web Server"
            }
          ]
        }
      ],
      "datePublic": "2017-10-04T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the context of the current system services."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-10-04T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01"
        },
        {
          "name": "100668",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100668"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-12728",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SpiderControl SCADA Web Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "SpiderControl SCADA Web Server"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the context of the current system services."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01"
            },
            {
              "name": "100668",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100668"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-12728",
    "datePublished": "2017-10-04T07:00:00.000Z",
    "dateReserved": "2017-08-09T00:00:00.000Z",
    "dateUpdated": "2024-08-05T18:43:56.611Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9940 (GCVE-0-2017-9940)

Vulnerability from cvelistv5 – Published: 2017-08-08 00:00 – Updated: 2024-08-05 17:25
VLAI
Summary
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with access to a low-privileged user account to read or write files on the file system of the SiPass integrated server over the network.
Severity
No CVSS data available.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
n/a SiPass integrated All versions before V2.70 Affected: SiPass integrated All versions before V2.70
Date Public
2017-08-07 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:25:00.497Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf"
          },
          {
            "name": "99578",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99578"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiPass integrated All versions before V2.70",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "SiPass integrated All versions before V2.70"
            }
          ]
        }
      ],
      "datePublic": "2017-08-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with access to a low-privileged user account to read or write files on the file system of the SiPass integrated server over the network."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269: Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-08T09:57:01.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf"
        },
        {
          "name": "99578",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99578"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2017-9940",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiPass integrated All versions before V2.70",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "SiPass integrated All versions before V2.70"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with access to a low-privileged user account to read or write files on the file system of the SiPass integrated server over the network."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269: Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf"
            },
            {
              "name": "99578",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99578"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-9940",
    "datePublished": "2017-08-08T00:00:00.000Z",
    "dateReserved": "2017-06-26T00:00:00.000Z",
    "dateUpdated": "2024-08-05T17:25:00.497Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7922 (GCVE-0-2017-7922)

Vulnerability from cvelistv5 – Published: 2017-06-21 19:00 – Updated: 2024-08-05 16:19
VLAI
Summary
An Improper Privilege Management issue was discovered in Cambium Networks ePMP. The privileges for SNMP community strings are not properly restricted, which may allow an attacker to gain access to sensitive information and possibly allow for configuration changes.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Cambium Networks ePMP Affected: Cambium Networks ePMP
Date Public
2017-06-21 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.327Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "99083",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99083"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-166-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cambium Networks ePMP",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Cambium Networks ePMP"
            }
          ]
        }
      ],
      "datePublic": "2017-06-21T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Privilege Management issue was discovered in Cambium Networks ePMP. The privileges for SNMP community strings are not properly restricted, which may allow an attacker to gain access to sensitive information and possibly allow for configuration changes."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-06-22T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "99083",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99083"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-166-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-7922",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cambium Networks ePMP",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Cambium Networks ePMP"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Privilege Management issue was discovered in Cambium Networks ePMP. The privileges for SNMP community strings are not properly restricted, which may allow an attacker to gain access to sensitive information and possibly allow for configuration changes."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "99083",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99083"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-166-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-166-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7922",
    "datePublished": "2017-06-21T19:00:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:19:29.327Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation MIT-1
Architecture and Design Operation

Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.

Mitigation MIT-48
Architecture and Design

Strategy: Separation of Privilege

Follow the principle of least privilege when assigning access rights to entities in a software system.

Mitigation MIT-49
Architecture and Design

Strategy: Separation of Privilege

Consider following the principle of separation of privilege. Require multiple conditions to be met before permitting access to a system resource.

CAPEC-122: Privilege Abuse

An adversary is able to exploit features of the target that should be reserved for privileged users or administrators but are exposed to use by lower or non-privileged accounts. Access to sensitive information and functionality must be controlled to ensure that only authorized users are able to access these resources.

CAPEC-233: Privilege Escalation

An adversary exploits a weakness enabling them to elevate their privilege and perform an action that they are not supposed to be authorized to perform.

CAPEC-58: Restful Privilege Elevation

An adversary identifies a Rest HTTP (Get, Put, Delete) style permission method allowing them to perform various malicious actions upon server data due to lack of access control mechanisms implemented within the application service accepting HTTP messages.