var-202401-2215
Vulnerability from variot

TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pppoePass parameter in the setIpv6Cfg function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. This vulnerability is caused by the pppoePass parameter of the setIpv6Cfg method failing to correctly filter special characters, commands, etc. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202401-2215",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "a3300r",
            scope: "eq",
            trust: 1,
            vendor: "totolink",
            version: "17.0.0cu.557_b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: "a3300r  firmware  17.0.0cu.557 b20221024",
         },
         {
            model: "a3300r",
            scope: "eq",
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r",
            scope: null,
            trust: 0.8,
            vendor: "totolink",
            version: null,
         },
         {
            model: "a3300r v17.0.0cu.557 b20221024",
            scope: null,
            trust: 0.6,
            vendor: "totolink",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   cve: "CVE-2024-24327",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  accessComplexity: "LOW",
                  accessVector: "NETWORK",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "COMPLETE",
                  baseScore: 10,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 10,
                  id: "CNVD-2024-09295",
                  impactScore: 10,
                  integrityImpact: "COMPLETE",
                  severity: "HIGH",
                  trust: 0.6,
                  vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "NETWORK",
                  author: "nvd@nist.gov",
                  availabilityImpact: "HIGH",
                  baseScore: 9.8,
                  baseSeverity: "CRITICAL",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 3.9,
                  id: "CVE-2024-24327",
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "NONE",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               {
                  attackComplexity: "Low",
                  attackVector: "Network",
                  author: "NVD",
                  availabilityImpact: "High",
                  baseScore: 9.8,
                  baseSeverity: "Critical",
                  confidentialityImpact: "High",
                  exploitabilityScore: null,
                  id: "CVE-2024-24327",
                  impactScore: null,
                  integrityImpact: "High",
                  privilegesRequired: "None",
                  scope: "Unchanged",
                  trust: 0.8,
                  userInteraction: "None",
                  vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  version: "3.0",
               },
            ],
            severity: [
               {
                  author: "nvd@nist.gov",
                  id: "CVE-2024-24327",
                  trust: 1,
                  value: "CRITICAL",
               },
               {
                  author: "NVD",
                  id: "CVE-2024-24327",
                  trust: 0.8,
                  value: "Critical",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2024-09295",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the pppoePass parameter in the setIpv6Cfg function. TOTOLINK of a3300r The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK A3300R is a wireless router made by China Zeon Electronics (TOTOLINK) Company. This vulnerability is caused by the pppoePass parameter of the setIpv6Cfg method failing to correctly filter special characters, commands, etc. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution",
      sources: [
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
      ],
      trust: 2.16,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2024-24327",
            trust: 3.2,
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
            trust: 0.8,
         },
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   id: "VAR-202401-2215",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
      ],
      trust: 0.06,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "Network device",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
      ],
   },
   last_update_date: "2024-08-14T14:42:48.189000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "Patch for TOTOLINK A3300R setIpv6Cfg method command injection vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchInfo/show/526031",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-78",
            trust: 1,
         },
         {
            problemtype: "OS Command injection (CWE-78) [NVD evaluation ]",
            trust: 0.8,
         },
      ],
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 2.4,
            url: "https://github.com/funny-mud-peee/iot-vuls/blob/main/totolink%20a3300r/7/totolink%20a3300r%20setipv6cfg.md",
         },
         {
            trust: 0.8,
            url: "https://nvd.nist.gov/vuln/detail/cve-2024-24327",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-08T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            date: "2024-02-07T00:00:00",
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            date: "2024-01-30T15:15:09.430000",
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2024-02-21T00:00:00",
            db: "CNVD",
            id: "CNVD-2024-09295",
         },
         {
            date: "2024-02-07T06:48:00",
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
         {
            date: "2024-02-01T04:49:22.830000",
            db: "NVD",
            id: "CVE-2024-24327",
         },
      ],
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "TOTOLINK  of  a3300r  in the firmware  OS  Command injection vulnerability",
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2024-002120",
         },
      ],
      trust: 0.8,
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.