var-202308-3144
Vulnerability from variot

Netgear EX6200 v1.0.3.94 was discovered to contain a buffer overflow via the wla_temp_ssid parameter at acosNvramConfig_set. of netgear EX6200 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. NETGEAR EX6200 is a wireless network signal extender from NETGEAR. The vulnerability originates from the fact that the wla_temp_ssid parameter in acosNvramConfig_set fails to correctly verify the length of the input data. Remote attackers can use this vulnerability to execute arbitrary code on the system or cause denial of service attack

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3144",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ex6200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "1.0.3.94"
      },
      {
        "model": "ex6200",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": "ex6200  firmware  1.0.3.94"
      },
      {
        "model": "ex6200",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "ex6200",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "ex6200",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "netgear",
        "version": "v1.0.3.94"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-64070"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021106"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38926"
      }
    ]
  },
  "cve": "CVE-2023-38926",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2023-64070",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2023-38926",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-38926",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-38926",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-38926",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-64070",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-64070"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021106"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38926"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Netgear EX6200 v1.0.3.94 was discovered to contain a buffer overflow via the wla_temp_ssid parameter at acosNvramConfig_set. of netgear EX6200 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. NETGEAR EX6200 is a wireless network signal extender from NETGEAR. The vulnerability originates from the fact that the wla_temp_ssid parameter in acosNvramConfig_set fails to correctly verify the length of the input data. Remote attackers can use this vulnerability to execute arbitrary code on the system or cause denial of service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-38926"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021106"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-64070"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-38926",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021106",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-64070",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-64070"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021106"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38926"
      }
    ]
  },
  "id": "VAR-202308-3144",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-64070"
      }
    ],
    "trust": 1.02142168
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-64070"
      }
    ]
  },
  "last_update_date": "2024-08-14T15:26:26.773000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for NETGEAR EX6200 Buffer Overflow Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/452016"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-64070"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021106"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38926"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/firmrec/iot-vulns/blob/main/netgear/nvram_ssid/readme.md"
      },
      {
        "trust": 1.8,
        "url": "https://www.netgear.com/about/security/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38926"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-64070"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021106"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38926"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-64070"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021106"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-38926"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-08-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-64070"
      },
      {
        "date": "2024-01-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-021106"
      },
      {
        "date": "2023-08-07T19:15:10.707000",
        "db": "NVD",
        "id": "CVE-2023-38926"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-08-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-64070"
      },
      {
        "date": "2024-01-18T06:49:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-021106"
      },
      {
        "date": "2023-08-09T18:04:22.037000",
        "db": "NVD",
        "id": "CVE-2023-38926"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "of netgear \u00a0EX6200\u00a0 Classic buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-021106"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.