VAR-202201-1882
Vulnerability from variot - Updated: 2024-02-13 22:59Dell EMC AppSync versions 3.9 to 4.3 contain an Improper Restriction of Excessive Authentication Attempts Vulnerability that can be exploited from UI and CLI. An adjacent unauthenticated attacker could potentially exploit this vulnerability, leading to password brute-forcing. Account takeover is possible if weak passwords are used by users. (DoS) It may be in a state. DELL EMC AppSync is a replication data management software of Dell (DELL). Provides a simple, SLA-driven, self-service way to protect, restore and clone critical Microsoft and Oracle applications and VMware environments
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202201-1882",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "emc appsync",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "4.4.0.0"
},
{
"model": "dell emc appsync",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "3.9 to 4.3"
},
{
"model": "dell emc appsync",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-003867"
},
{
"db": "NVD",
"id": "CVE-2022-22553"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:dell:emc_appsync:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.4.0.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-22553"
}
]
},
"cve": "CVE-2022-22553",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2022-22553",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-411180",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "security_alert@emc.com",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-22553",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-22553",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2022-22553",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202201-2176",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-411180",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2022-22553",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-411180"
},
{
"db": "VULMON",
"id": "CVE-2022-22553"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-003867"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-2176"
},
{
"db": "NVD",
"id": "CVE-2022-22553"
},
{
"db": "NVD",
"id": "CVE-2022-22553"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell EMC AppSync versions 3.9 to 4.3 contain an Improper Restriction of Excessive Authentication Attempts Vulnerability that can be exploited from UI and CLI. An adjacent unauthenticated attacker could potentially exploit this vulnerability, leading to password brute-forcing. Account takeover is possible if weak passwords are used by users. (DoS) It may be in a state. DELL EMC AppSync is a replication data management software of Dell (DELL). Provides a simple, SLA-driven, self-service way to protect, restore and clone critical Microsoft and Oracle applications and VMware environments",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-22553"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-003867"
},
{
"db": "VULHUB",
"id": "VHN-411180"
},
{
"db": "VULMON",
"id": "CVE-2022-22553"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-22553",
"trust": 3.4
},
{
"db": "JVNDB",
"id": "JVNDB-2022-003867",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202201-2176",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2022-06707",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-411180",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2022-22553",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-411180"
},
{
"db": "VULMON",
"id": "CVE-2022-22553"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-003867"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-2176"
},
{
"db": "NVD",
"id": "CVE-2022-22553"
}
]
},
"id": "VAR-202201-1882",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-411180"
}
],
"trust": 0.01
},
"last_update_date": "2024-02-13T22:59:41.459000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "DSA-2022-003",
"trust": 0.8,
"url": "https://www.dell.com/support/kbdoc/ja-jp/000195377/dsa-2022-003-dell-emc-appsync-security-update-for-multiple-vulnerabilities"
},
{
"title": "DELL EMC AppSync Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=183801"
},
{
"title": "CVE-2022-XXXX",
"trust": 0.1,
"url": "https://github.com/alphabugx/cve-2022-23305 "
},
{
"title": "CVE-2022-XXXX",
"trust": 0.1,
"url": "https://github.com/alphabugx/cve-2022-rce "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-22553"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-003867"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-2176"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-307",
"trust": 1.1
},
{
"problemtype": "Inappropriate limitation of excessive authentication attempts (CWE-307) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-411180"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-003867"
},
{
"db": "NVD",
"id": "CVE-2022-22553"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://www.dell.com/support/kbdoc/000195377"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-22553"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/307.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://github.com/alphabugx/cve-2022-23305"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-411180"
},
{
"db": "VULMON",
"id": "CVE-2022-22553"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-003867"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-2176"
},
{
"db": "NVD",
"id": "CVE-2022-22553"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-411180"
},
{
"db": "VULMON",
"id": "CVE-2022-22553"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-003867"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-2176"
},
{
"db": "NVD",
"id": "CVE-2022-22553"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-01-21T00:00:00",
"db": "VULHUB",
"id": "VHN-411180"
},
{
"date": "2022-01-21T00:00:00",
"db": "VULMON",
"id": "CVE-2022-22553"
},
{
"date": "2023-03-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-003867"
},
{
"date": "2022-01-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202201-2176"
},
{
"date": "2022-01-21T21:15:09.223000",
"db": "NVD",
"id": "CVE-2022-22553"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-01-27T00:00:00",
"db": "VULHUB",
"id": "VHN-411180"
},
{
"date": "2022-01-27T00:00:00",
"db": "VULMON",
"id": "CVE-2022-22553"
},
{
"date": "2023-03-10T01:50:00",
"db": "JVNDB",
"id": "JVNDB-2022-003867"
},
{
"date": "2022-03-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202201-2176"
},
{
"date": "2022-01-27T15:07:07.777000",
"db": "NVD",
"id": "CVE-2022-22553"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202201-2176"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u00a0EMC\u00a0AppSync\u00a0 Vulnerability in improperly limiting excessive authentication attempts in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-003867"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202201-2176"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.