var-202112-2392
Vulnerability from variot

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects GS108Tv2 before 5.4.2.36, GS110TPP before 7.0.7.2, GS110TPv2 before 5.4.2.36., GS110TPv3 before 7.0.7.2, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS752TPP before 6.0.8.2, GS752TPv2 before 6.0.8.2, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects GS108Tv2 prior to 5.4.2.36, GS110TPP prior to 7.0.7.2, GS110TPv2 prior to 5.4.2.36., GS110TPv3 prior to 7.0.7.2, GS308T prior to 1.0.3.2, GS310TP prior to 1.0.3.2, GS724TPP prior to 2.0.6.3, GS724TPv2 prior to 2.0.6.3, GS728TPPv2 prior to 6.0.8.2, GS728TPv2 prior to 6.0.8.2, GS752TPP prior to 6.0.8.2, GS752TPv2 prior to 6.0.8.2, MS510TXM prior to 1.0.4.2, and MS510TXUP prior to 1.0.4.2

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2392",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ms510txm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "1.0.4.2"
      },
      {
        "model": "gs724tpp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "2.0.6.3"
      },
      {
        "model": "gs110tpp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "7.0.7.2"
      },
      {
        "model": "gs110tpv3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "7.0.7.2"
      },
      {
        "model": "gs752tpp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "6.0.8.2"
      },
      {
        "model": "gs728tppv2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "6.0.8.2"
      },
      {
        "model": "gs752tpv2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "6.0.8.2"
      },
      {
        "model": "gs728tpv2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "6.0.8.2"
      },
      {
        "model": "gs724tpv2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "2.0.6.3"
      },
      {
        "model": "gs308t",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "1.0.3.2"
      },
      {
        "model": "ms510txup",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "1.0.4.2"
      },
      {
        "model": "gs108tv2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "5.4.2.36"
      },
      {
        "model": "gs110tpv2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "5.4.2.36"
      },
      {
        "model": "gs310tp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "1.0.3.2"
      },
      {
        "model": "gs310tp",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "gs308t",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "gs728tppv2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "gs110tpv2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "gs110tpv3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "gs724tpv2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "gs110tpp",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "gs728tpv2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "gs724tpp",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "gs108tv2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017572"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45556"
      }
    ]
  },
  "cve": "CVE-2021-45556",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CVE-2021-45556",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2021-45556",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "author": "cve@mitre.org",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.0,
            "id": "CVE-2021-45556",
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:C/C:L/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-45556",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-45556",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "cve@mitre.org",
            "id": "CVE-2021-45556",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-45556",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202112-2372",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017572"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2372"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45556"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45556"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects GS108Tv2 before 5.4.2.36, GS110TPP before 7.0.7.2, GS110TPv2 before 5.4.2.36., GS110TPv3 before 7.0.7.2, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS752TPP before 6.0.8.2, GS752TPv2 before 6.0.8.2, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects GS108Tv2 prior to 5.4.2.36, GS110TPP prior to 7.0.7.2, GS110TPv2 prior to 5.4.2.36., GS110TPv3 prior to 7.0.7.2, GS308T prior to 1.0.3.2, GS310TP prior to 1.0.3.2, GS724TPP prior to 2.0.6.3, GS724TPv2 prior to 2.0.6.3, GS728TPPv2 prior to 6.0.8.2, GS728TPv2 prior to 6.0.8.2, GS752TPP prior to 6.0.8.2, GS752TPv2 prior to 6.0.8.2, MS510TXM prior to 1.0.4.2, and MS510TXUP prior to 1.0.4.2",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-45556"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017572"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-45556"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-45556",
        "trust": 3.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017572",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2372",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-45556",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-45556"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017572"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2372"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45556"
      }
    ]
  },
  "id": "VAR-202112-2392",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.6424417246153845
  },
  "last_update_date": "2024-11-23T22:44:06.919000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Smart\u00a0Managed\u00a0Pro\u00a0Switches,\u00a0PSV-2021-0175",
        "trust": 0.8,
        "url": "https://kb.netgear.com/000064534/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Smart-Managed-Pro-Switches-PSV-2021-0175"
      },
      {
        "title": "Netgear NETGEAR Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176664"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017572"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2372"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-77",
        "trust": 1.0
      },
      {
        "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017572"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45556"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://kb.netgear.com/000064534/security-advisory-for-post-authentication-command-injection-on-some-smart-managed-pro-switches-psv-2021-0175"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45556"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-45556"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017572"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2372"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45556"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2021-45556"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017572"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2372"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45556"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-12-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-45556"
      },
      {
        "date": "2023-01-27T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-017572"
      },
      {
        "date": "2021-12-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202112-2372"
      },
      {
        "date": "2021-12-26T01:15:15.660000",
        "db": "NVD",
        "id": "CVE-2021-45556"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-12-27T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-45556"
      },
      {
        "date": "2023-01-27T01:39:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-017572"
      },
      {
        "date": "2022-01-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202112-2372"
      },
      {
        "date": "2024-11-21T06:32:30.637000",
        "db": "NVD",
        "id": "CVE-2021-45556"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2372"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017572"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2372"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.