var-202103-0895
Vulnerability from variot
This vulnerability allows remote attackers to disclose sensitive information and delete arbitrary files on affected installations of NETGEAR ProSAFE Network Management System 1.6.0.26. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the ConfigFileController class. When parsing the realName parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to disclose sensitive information or to create a denial-of-service condition on the system. Was ZDI-CAN-12125. NETGEAR ProSAFE Network Management System Contains a path traversal vulnerability. Zero Day Initiative To this vulnerability ZDI-CAN-12125 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Netgear NETGEAR is a router made by Netgear. A hardware device that connects two or more networks, acting as a gateway between the networks
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-0895", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "prosafe network management system", "scope": "eq", "trust": 1.0, "vendor": "netgear", "version": "1.6.0.26" }, { "model": "prosafe network management system", "scope": "eq", "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": "1.6.0.26" }, { "model": "prosafe network management system", "scope": "eq", "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "prosafe network management system", "scope": null, "trust": 0.7, "vendor": "netgear", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-358" }, { "db": "JVNDB", "id": "JVNDB-2021-004807" }, { "db": "NVD", "id": "CVE-2021-27275" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "rgod", "sources": [ { "db": "ZDI", "id": "ZDI-21-358" } ], "trust": 0.7 }, "cve": "CVE-2021-27275", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2021-27275", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "VHN-386508", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "zdi-disclosures@trendmicro.com", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-27275", "impactScore": 5.5, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-27275", "impactScore": 5.5, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-27275", "impactScore": 5.5, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "NONE", "vectorString": "AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-27275", "trust": 1.0, "value": "HIGH" }, { "author": "zdi-disclosures@trendmicro.com", "id": "CVE-2021-27275", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2021-27275", "trust": 0.8, "value": "High" }, { "author": "ZDI", "id": "CVE-2021-27275", "trust": 0.7, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202103-1564", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-386508", "trust": 0.1, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-27275", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-358" }, { "db": "VULHUB", "id": "VHN-386508" }, { "db": "VULMON", "id": "CVE-2021-27275" }, { "db": "JVNDB", "id": "JVNDB-2021-004807" }, { "db": "CNNVD", "id": "CNNVD-202103-1564" }, { "db": "NVD", "id": "CVE-2021-27275" }, { "db": "NVD", "id": "CVE-2021-27275" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "This vulnerability allows remote attackers to disclose sensitive information and delete arbitrary files on affected installations of NETGEAR ProSAFE Network Management System 1.6.0.26. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the ConfigFileController class. When parsing the realName parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to disclose sensitive information or to create a denial-of-service condition on the system. Was ZDI-CAN-12125. NETGEAR ProSAFE Network Management System Contains a path traversal vulnerability. Zero Day Initiative To this vulnerability ZDI-CAN-12125 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Netgear NETGEAR is a router made by Netgear. A hardware device that connects two or more networks, acting as a gateway between the networks", "sources": [ { "db": "NVD", "id": "CVE-2021-27275" }, { "db": "JVNDB", "id": "JVNDB-2021-004807" }, { "db": "ZDI", "id": "ZDI-21-358" }, { "db": "VULHUB", "id": "VHN-386508" }, { "db": "VULMON", "id": "CVE-2021-27275" } ], "trust": 2.43 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-27275", "trust": 3.3 }, { "db": "ZDI", "id": "ZDI-21-358", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-004807", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-12125", "trust": 0.7 }, { "db": "CNNVD", "id": "CNNVD-202103-1564", "trust": 0.7 }, { "db": "VULHUB", "id": "VHN-386508", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2021-27275", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-358" }, { "db": "VULHUB", "id": "VHN-386508" }, { "db": "VULMON", "id": "CVE-2021-27275" }, { "db": "JVNDB", "id": "JVNDB-2021-004807" }, { "db": "CNNVD", "id": "CNNVD-202103-1564" }, { "db": "NVD", "id": "CVE-2021-27275" } ] }, "id": "VAR-202103-0895", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-386508" } ], "trust": 0.01 }, "last_update_date": "2024-11-23T23:07:38.373000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "NETGEAR\u00a0Support\u00a0(Security\u00a0Advisory\u00a0for\u00a0Denial\u00a0of\u00a0Service\u00a0on\u00a0NMS300,\u00a0PSV-2020-0561)", "trust": 1.5, "url": "https://kb.netgear.com/000062687/Security-Advisory-for-Denial-of-Service-on-NMS300-PSV-2020-0561" }, { "title": "NETGEAR ProSAFE Network Management System Repair measures for path traversal vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145794" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-358" }, { "db": "JVNDB", "id": "JVNDB-2021-004807" }, { "db": "CNNVD", "id": "CNNVD-202103-1564" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-22", "trust": 1.1 }, { "problemtype": "Path traversal (CWE-22) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-386508" }, { "db": "JVNDB", "id": "JVNDB-2021-004807" }, { "db": "NVD", "id": "CVE-2021-27275" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.2, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-358/" }, { "trust": 2.5, "url": "https://kb.netgear.com/000062687/security-advisory-for-denial-of-service-on-nms300-psv-2020-0561" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27275" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/22.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/198891" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-358" }, { "db": "VULHUB", "id": "VHN-386508" }, { "db": "VULMON", "id": "CVE-2021-27275" }, { "db": "JVNDB", "id": "JVNDB-2021-004807" }, { "db": "CNNVD", "id": "CNNVD-202103-1564" }, { "db": "NVD", "id": "CVE-2021-27275" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "ZDI", "id": "ZDI-21-358" }, { "db": "VULHUB", "id": "VHN-386508" }, { "db": "VULMON", "id": "CVE-2021-27275" }, { "db": "JVNDB", "id": "JVNDB-2021-004807" }, { "db": "CNNVD", "id": "CNNVD-202103-1564" }, { "db": "NVD", "id": "CVE-2021-27275" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-26T00:00:00", "db": "ZDI", "id": "ZDI-21-358" }, { "date": "2021-03-29T00:00:00", "db": "VULHUB", "id": "VHN-386508" }, { "date": "2021-03-29T00:00:00", "db": "VULMON", "id": "CVE-2021-27275" }, { "date": "2021-11-30T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004807" }, { "date": "2021-03-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1564" }, { "date": "2021-03-29T21:15:13.267000", "db": "NVD", "id": "CVE-2021-27275" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-26T00:00:00", "db": "ZDI", "id": "ZDI-21-358" }, { "date": "2021-03-30T00:00:00", "db": "VULHUB", "id": "VHN-386508" }, { "date": "2021-03-30T00:00:00", "db": "VULMON", "id": "CVE-2021-27275" }, { "date": "2021-11-30T08:35:00", "db": "JVNDB", "id": "JVNDB-2021-004807" }, { "date": "2021-03-31T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1564" }, { "date": "2024-11-21T05:57:44.607000", "db": "NVD", "id": "CVE-2021-27275" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1564" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "NETGEAR\u00a0ProSAFE\u00a0Network\u00a0Management\u00a0System\u00a0 Traversal Vulnerability in Japan", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004807" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "path traversal", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1564" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.