var-202004-1467
Vulnerability from variot
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R8300 before 1.0.2.106 and R8500 before 1.0.2.106. NETGEAR R8300 and R8500 A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R8500 and NETGEAR R8300 are both wireless routers of NETGEAR. This vulnerability stems from network systems or products performing operations on memory without properly verifying the data boundary, which leads to other associated memory locations. This affects R8300 prior to 1.0.2.106 and R8500 prior to 1.0.2.106
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202004-1467", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r8500", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.106" }, { "model": "r8300", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.106" }, { "model": "r8300", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.2.106" }, { "model": "r8500", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.2.106" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-28007" }, { "db": "JVNDB", "id": "JVNDB-2017-015005" }, { "db": "NVD", "id": "CVE-2017-18707" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:netgear:r8300_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:netgear:r8500_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-015005" } ] }, "cve": "CVE-2017-18707", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2017-18707", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.1, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2017-015005", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CNVD-2020-28007", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2017-18707", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2017-18707", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2017-015005", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2017-18707", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2017-18707", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2017-015005", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2020-28007", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202004-2096", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2017-18707", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-28007" }, { "db": "VULMON", "id": "CVE-2017-18707" }, { "db": "JVNDB", "id": "JVNDB-2017-015005" }, { "db": "CNNVD", "id": "CNNVD-202004-2096" }, { "db": "NVD", "id": "CVE-2017-18707" }, { "db": "NVD", "id": "CVE-2017-18707" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R8300 before 1.0.2.106 and R8500 before 1.0.2.106. NETGEAR R8300 and R8500 A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R8500 and NETGEAR R8300 are both wireless routers of NETGEAR. This vulnerability stems from network systems or products performing operations on memory without properly verifying the data boundary, which leads to other associated memory locations. This affects R8300 prior to 1.0.2.106 and R8500 prior to 1.0.2.106", "sources": [ { "db": "NVD", "id": "CVE-2017-18707" }, { "db": "JVNDB", "id": "JVNDB-2017-015005" }, { "db": "CNVD", "id": "CNVD-2020-28007" }, { "db": "VULMON", "id": "CVE-2017-18707" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2017-18707", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2017-015005", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-28007", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202004-2096", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2017-18707", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-28007" }, { "db": "VULMON", "id": "CVE-2017-18707" }, { "db": "JVNDB", "id": "JVNDB-2017-015005" }, { "db": "CNNVD", "id": "CNNVD-202004-2096" }, { "db": "NVD", "id": "CVE-2017-18707" } ] }, "id": "VAR-202004-1467", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-28007" } ], "trust": 1.09248156 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-28007" } ] }, "last_update_date": "2024-11-23T23:01:24.349000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Post-Authentication Buffer Overflow on Some Routers, PSV-2017-0316", "trust": 0.8, "url": "https://kb.netgear.com/000053158/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-PSV-2017-0316" }, { "title": "Patch for NETGEAR R8500 and R8300 buffer overflow vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/217307" }, { "title": "NETGEAR R8500 and R8300 Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=117019" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-28007" }, { "db": "JVNDB", "id": "JVNDB-2017-015005" }, { "db": "CNNVD", "id": "CNNVD-202004-2096" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-015005" }, { "db": "NVD", "id": "CVE-2017-18707" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-18707" }, { "trust": 1.7, "url": "https://kb.netgear.com/000053158/security-advisory-for-post-authentication-buffer-overflow-on-some-routers-psv-2017-0316" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-18707" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/120.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-28007" }, { "db": "VULMON", "id": "CVE-2017-18707" }, { "db": "JVNDB", "id": "JVNDB-2017-015005" }, { "db": "CNNVD", "id": "CNNVD-202004-2096" }, { "db": "NVD", "id": "CVE-2017-18707" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-28007" }, { "db": "VULMON", "id": "CVE-2017-18707" }, { "db": "JVNDB", "id": "JVNDB-2017-015005" }, { "db": "CNNVD", "id": "CNNVD-202004-2096" }, { "db": "NVD", "id": "CVE-2017-18707" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-05-13T00:00:00", "db": "CNVD", "id": "CNVD-2020-28007" }, { "date": "2020-04-24T00:00:00", "db": "VULMON", "id": "CVE-2017-18707" }, { "date": "2020-06-03T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-015005" }, { "date": "2020-04-24T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-2096" }, { "date": "2020-04-24T14:15:12.547000", "db": "NVD", "id": "CVE-2017-18707" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-05-13T00:00:00", "db": "CNVD", "id": "CNVD-2020-28007" }, { "date": "2020-05-01T00:00:00", "db": "VULMON", "id": "CVE-2017-18707" }, { "date": "2020-06-03T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-015005" }, { "date": "2020-05-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-2096" }, { "date": "2024-11-21T03:20:42.980000", "db": "NVD", "id": "CVE-2017-18707" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-2096" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "NETGEAR R8300 and R8500 Classic buffer overflow vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-015005" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-2096" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.