eQ-3 Homematic CCU2 and CCU3 obtain session IDs without login. This allows a Denial of Service and is a starting point for other attacks. Affected versions for CCU2: 2.35.16, 2.41.5, 2.41.8, 2.41.9, 2.45.6, 2.45.7, 2.47.10, 2.47.12, 2.47.15. Affected versions for CCU3: 3.41.11, 3.43.16, 3.45.5, 3.45.7, 3.47.10, 3.47.15. eQ-3 Homematic CCU2 and CCU3 Contains a resource exhaustion vulnerability.Tampering with information and disrupting service operations (DoS) There is a possibility of being put into a state. Both eQ-3 Homematic CCU3 and eQ-3 Homematic CCU2 are central control units of a smart home system produced by German eQ-3 company. A resource management error vulnerability exists in the eQ-3 Homematic CCU2 and eQ-3 Homematic CCU3. The following products and versions are affected: eQ-3 Homematic CCU2 Version 2.35.16, Version 2.41.5, Version 2.41.8, Version 2.41.9, Version 2.45.6, Version 2.45.7, Version 2.47.10, Version 2.47.12 Version, version 2.47.15; eQ-3 Homematic CCU3 version 3.41.11, version 3.43.16, version 3.45.5, version 3.45.7, version 3.47.10, version 3.47.15
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201908-0257", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "homematic ccu3", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "3.41.11" }, { "model": "homematic ccu2", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "2.41.8" }, { "model": "homematic ccu2", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "2.45.6" }, { "model": "homematic ccu3", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "3.47.15" }, { "model": "homematic ccu2", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "2.41.5" }, { "model": "homematic ccu3", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "3.45.5" }, { "model": "homematic ccu3", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "3.43.16" }, { "model": "homematic ccu2", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "2.41.9" }, { "model": "homematic ccu2", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "2.45.7" }, { "model": "homematic ccu2", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "2.47.15" }, { "model": "homematic ccu2", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "2.35.16" }, { "model": "homematic ccu2", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "2.47.12" }, { "model": "homematic ccu2", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "2.47.10" }, { "model": "homematic ccu3", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "3.47.10" }, { "model": "homematic ccu3", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": "3.45.7" }, { "model": "homematic ccu2", "scope": "eq", "trust": 1.0, "vendor": "eq 3", "version": null }, { "model": "ccu2", "scope": null, "trust": 0.8, "vendor": "eq 3", "version": null }, { "model": "ccu3", "scope": null, "trust": 0.8, "vendor": "eq 3", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-008361" }, { "db": "NVD", "id": "CVE-2019-9583" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:eq-3:ccu2_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:eq-3:ccu3_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-008361" } ] }, "cve": "CVE-2019-9583", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2019-9583", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-161018", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2019-9583", "impactScore": 4.2, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.2, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2019-9583", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-9583", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2019-9583", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-201908-1078", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-161018", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-161018" }, { "db": "JVNDB", "id": "JVNDB-2019-008361" }, { "db": "CNNVD", "id": "CNNVD-201908-1078" }, { "db": "NVD", "id": "CVE-2019-9583" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "eQ-3 Homematic CCU2 and CCU3 obtain session IDs without login. This allows a Denial of Service and is a starting point for other attacks. Affected versions for CCU2: 2.35.16, 2.41.5, 2.41.8, 2.41.9, 2.45.6, 2.45.7, 2.47.10, 2.47.12, 2.47.15. Affected versions for CCU3: 3.41.11, 3.43.16, 3.45.5, 3.45.7, 3.47.10, 3.47.15. eQ-3 Homematic CCU2 and CCU3 Contains a resource exhaustion vulnerability.Tampering with information and disrupting service operations (DoS) There is a possibility of being put into a state. Both eQ-3 Homematic CCU3 and eQ-3 Homematic CCU2 are central control units of a smart home system produced by German eQ-3 company. A resource management error vulnerability exists in the eQ-3 Homematic CCU2 and eQ-3 Homematic CCU3. The following products and versions are affected: eQ-3 Homematic CCU2 Version 2.35.16, Version 2.41.5, Version 2.41.8, Version 2.41.9, Version 2.45.6, Version 2.45.7, Version 2.47.10, Version 2.47.12 Version, version 2.47.15; eQ-3 Homematic CCU3 version 3.41.11, version 3.43.16, version 3.45.5, version 3.45.7, version 3.47.10, version 3.47.15", "sources": [ { "db": "NVD", "id": "CVE-2019-9583" }, { "db": "JVNDB", "id": "JVNDB-2019-008361" }, { "db": "VULHUB", "id": "VHN-161018" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-9583", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2019-008361", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201908-1078", "trust": 0.7 }, { "db": "VULHUB", "id": "VHN-161018", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-161018" }, { "db": "JVNDB", "id": "JVNDB-2019-008361" }, { "db": "CNNVD", "id": "CNNVD-201908-1078" }, { "db": "NVD", "id": "CVE-2019-9583" } ] }, "id": "VAR-201908-0257", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-161018" } ], "trust": 0.6119048 }, "last_update_date": "2024-11-23T22:41:26.578000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top Page", "trust": 0.8, "url": "https://www.eq-3.com/" }, { "title": "eQ-3 Homematic CCU2 and CCU3 Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=96749" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-008361" }, { "db": "CNNVD", "id": "CNNVD-201908-1078" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-161018" }, { "db": "JVNDB", "id": "JVNDB-2019-008361" }, { "db": "NVD", "id": "CVE-2019-9583" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/psytester/psytester.github.io/blob/master/_posts/hacking_and_pentests/cves/2019-03-27-cve-2019-9583.md" }, { "trust": 1.7, "url": "https://psytester.github.io/cve-2019-9583/" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-9583" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-9583" } ], "sources": [ { "db": "VULHUB", "id": "VHN-161018" }, { "db": "JVNDB", "id": "JVNDB-2019-008361" }, { "db": "CNNVD", "id": "CNNVD-201908-1078" }, { "db": "NVD", "id": "CVE-2019-9583" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-161018" }, { "db": "JVNDB", "id": "JVNDB-2019-008361" }, { "db": "CNNVD", "id": "CNNVD-201908-1078" }, { "db": "NVD", "id": "CVE-2019-9583" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-08-14T00:00:00", "db": "VULHUB", "id": "VHN-161018" }, { "date": "2019-08-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-008361" }, { "date": "2019-08-14T00:00:00", "db": "CNNVD", "id": "CNNVD-201908-1078" }, { "date": "2019-08-14T20:15:11.790000", "db": "NVD", "id": "CVE-2019-9583" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-04-10T00:00:00", "db": "VULHUB", "id": "VHN-161018" }, { "date": "2019-08-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-008361" }, { "date": "2019-08-28T00:00:00", "db": "CNNVD", "id": "CNNVD-201908-1078" }, { "date": "2024-11-21T04:51:54.180000", "db": "NVD", "id": "CVE-2019-9583" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201908-1078" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "eQ-3 Homematic CCU2 and CCU3 Vulnerable to resource exhaustion", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-008361" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "resource management error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201908-1078" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.